Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Eur Radiol ; 33(11): 8122-8131, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37278853

RESUMEN

OBJECTIVE: To investigate the utility of ultrafast dynamic-contrast-enhanced (DCE) MRI in visualization and quantitative characterization of pregnancy-associated breast cancer (PABC) and its differentiation from background-parenchymal-enhancement (BPE) among lactating patients. MATERIALS AND METHODS: Twenty-nine lactating participants, including 10 PABC patients and 19 healthy controls, were scanned on 3-T MRI using a conventional DCE protocol interleaved with a golden-angle radial sparse parallel (GRASP) ultrafast sequence for the initial phase. The timing of the visualization of PABC lesions was compared to lactational BPE. Contrast-noise ratio (CNR) was compared between the ultrafast and conventional DCE sequences. The differences in each group's ultrafast-derived kinetic parameters including maximal slope (MS), time to enhancement (TTE), and area under the curve (AUC) were statistically examined using the Mann-Whitney test and receiver operator characteristic (ROC) curve analysis. RESULTS: On ultrafast MRI, breast cancer lesions enhanced earlier than BPE (p < 0.0001), enabling breast cancer visualization freed from lactation BPE. A higher CNR was found for ultrafast acquisitions vs. conventional DCE (p < 0.05). Significant differences in AUC, MS, and TTE values were found between the tumor and BPE (p < 0.05), with ROC-derived AUC of 0.86 ± 0.06, 0.82 ± 0.07, and 0.68 ± 0.08, respectively. The BPE grades of the lactating PABC patients were reduced as compared with the healthy lactating controls (p < 0.005). CONCLUSION: Ultrafast DCE MRI allows BPE-free visualization of lesions, improved tumor conspicuity, and kinetic quantification of breast cancer during lactation. Implementation of this method may assist in the utilization of breast MRI for lactating patients. CLINICAL RELEVANCE: The ultrafast sequence appears to be superior to conventional DCE MRI in the challenging evaluation of the lactating breast. Thus, supporting its possible utilization in the setting of high-risk screening during lactation and the diagnostic workup of PABC. KEY POINTS: • Differences in the enhancement slope of cancer relative to BPE allowed the optimal visualization of PABC lesions on mid-acquisitions of ultrafast DCE, in which the tumor enhanced prior to the background parenchyma. • The conspicuity of PABC lesions on top of the lactation-related BPE was increased using an ultrafast sequence as compared with conventional DCE MRI. • Ultrafast-derived maps provided further characterization and parametric contrast between PABC lesions and lactation-related BPE.


Asunto(s)
Neoplasias de la Mama , Lactancia , Femenino , Embarazo , Humanos , Neoplasias de la Mama/patología , Aumento de la Imagen/métodos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
2.
J Med Imaging Radiat Oncol ; 67(6): 587-594, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37036181

RESUMEN

INTRODUCTION: A pacemaker may affect the utility of a mammogram in several ways. The aim of this study is to summarize our institution's experience with mammograms among patients with a cardiac pacemaker, focusing on the diagnostic workup among patients with a newly diagnosed ipsilateral breast cancer. METHODS: A retrospective search of all mammography reports between January 2011 and April 2021 was conducted for identifying cases of patients with a pacemaker. Demographic and clinical characteristics as well as mammography-derived quality parameters and findings were categorized and statistically compared. RESULTS: The incidence of pacemaker concurrence in mammographic examination, although apparently slightly under-documented, accounted for 0.33% of cases. Population mean age was 71.7 years, and most patients (79%) had a left-sided pacemaker. The pacemaker was much more likely to be projected on the medio-lateral-oblique (96%) than on the cranio-caudal view (10%), on the axilla rather than the breast, and on the retro-pectoral rather than the pre-pectoral region (P < 0.001 for all). Compression force decreased by up to 23.0% (P < 0.001) and breast thickness increased by up to 9.5% (P < 0.001) for the ipsilateral vs. the contralateral side. Among 11 patients with newly diagnosed ipsilateral breast cancer, the pacemaker partially projected on the tumour region in two cases, and significantly obscured the tumour in another two. CONCLUSION: Although rare, the coexistence of a pacemaker in patients undergoing mammography is associated with reduced image quality due to suboptimal breast visualization and reduced compression, and as a result, this may eventually lead to decreased diagnostic efficacy.


Asunto(s)
Neoplasias de la Mama , Humanos , Anciano , Femenino , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/patología , Estudios Retrospectivos , Mamografía/métodos , Mama/patología
3.
Insights Imaging ; 13(1): 71, 2022 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-35397082

RESUMEN

The breast experiences substantial changes in morphology and function during pregnancy and lactation which affects its imaging properties and may reduce the visibility of a concurrent pathological process. The high incidence of benign gestational-related entities may further add complexity to the clinical and radiological evaluation of the breast during the period. Consequently, pregnancy-associated breast cancer (PABC) is often a delayed diagnosis and carries a poor prognosis. This state-of-the-art pictorial review illustrates how despite currently being underutilized, technical advances and new clinical evidence support the use of unenhanced breast MRI during pregnancy and both unenhanced and dynamic-contrast enhanced (DCE) during lactation, to serve as effective supplementary modalities in the diagnostic work-up of PABC.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...