Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 81
Filtrar
1.
Brachytherapy ; 2024 May 28.
Artículo en Inglés | MEDLINE | ID: mdl-38811275

RESUMEN

INTRODUCTION: Iodine-125 (I-125) seeds, commonly used in low-dose rate brachytherapy for ocular malignancies, are often discarded after a single use. This study examines the potential cost savings at an institution with high ocular melanoma referrals, by re-using I-125 seeds for eye-plaque brachytherapy. METHODS: In this single-institutional retrospective analysis, data was collected from I-125 seed orders from 8/2019 through 10/2022. Information including number of seeds ordered per lot, number of plaques built per lot, and number of seeds used per lot were collected. Cost per lot of seed was assumed to be the current cost from the most recent lot of 35 seeds. RESULTS: During the study, 72 I-125 seed lots were ordered bi-weekly, with a median of 35 seeds per lot (Range: 15-35). Each seed was used on average 2.26 times prior to being discarded. The average duration of each seed lot used was 62.2 days (Range: 21-126). Each seed lot contributed to the construction of an average of 8.4 eye plaques (Range: 2-20). With seed recycling, 2,475 seeds were used to construct 608 eye-plaques. Without re-using practice this would require 5,694 seeds. This resulted in a percentage cost savings of 56.5%, with a total seed cost reduction of $344,884, or $559 per eye-plaque on average. CONCLUSION: This is the first study to evaluate cost savings relative to re-using I-125 seeds for eye plaques. The data demonstrates how an institution can decrease costs associated with I-125 radiation seeds used for eye-plaque brachytherapy by re-using them.

2.
J Appl Clin Med Phys ; : e14395, 2024 May 14.
Artículo en Catalán | MEDLINE | ID: mdl-38742823

RESUMEN

PURPOSE: For the custom-built construction of eye plaques, the iodine (I-125) seeds of different source strengths are recycled in our eye plaque program. To return I-125 seeds to the correct lot, we developed a novel 3D-printed conical plaque QA holder for relative assay for eye plaques. MATERIALS AND METHODS: A universal 3D-printed conical plaque holder was designed to accommodate six plaque sizes and fit reproducibly in a well-type dose calibrator. A reproducibility test was used to compare the plaque placement consistency in the holder versus without the holder. Plaque assays were performed for assembled plaques both before implant and after explant. The explant reading was compared with the implant reading adjusted for decay, and the relative error was calculated. The plaque response fraction (PRF) is defined as the fraction of well chamber implant reading over the total seed strength for a plaque. The PRF was aggregated for each individual plaque to confirm the seed lot before implant. RESULTS: The reproducibility test showed the chamber reading's relative standard deviation of 0.40% with the QA holder compared to 0.68% without it. The batch relative assay was performed for 251 plaques. The absolute value of measurement deviation between explant and decay-corrected implant readings is 0.89% ± 0.86% (mean ± standard deviation). The PRFs for individual plaques range from 36.49% to 49.87%, with a maximum standard deviation of 2%. CONCLUSIONS: This novel 3D-printed QA holder provides reproducible setup for assaying assembled eye plaques in a well chamber. Batch relative assay can validate the seed batch used and plaque integrity during the implant without assaying individual seeds, saving valuable physicist time and radiation exposure from seed handling.

3.
Brachytherapy ; 22(6): 716-727, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37704540

RESUMEN

PURPOSE: The global cervical cancer burden is disproportionately high in low- and middle-income countries (LMICs), and outcomes can be governed by the accessibility of appropriate screening and treatment. High-dose-rate (HDR) brachytherapy plays a central role in cervical cancer treatment, improving local control and overall survival. The American Brachytherapy Society (ABS) and Indian Brachytherapy Society (IBS) collaborated to provide this succinct consensus statement guiding the establishment of brachytherapy programs for gynecological malignancies in resource-limited settings. METHODS AND MATERIALS: ABS and IBS members with expertise in brachytherapy formulated this consensus statement based on their collective clinical experience in LMICs with varying levels of resources. RESULTS: The ABS and IBS strongly encourage the establishment of HDR brachytherapy programs for the treatment of gynecological malignancies. With the consideration of resource variability in LMICs, we present 15 minimum component requirements for the establishment of such programs. Guidance on these components, including discussion of what is considered to be essential and what is considered to be optimal, is provided. CONCLUSIONS: This ABS/IBS consensus statement can guide the successful and safe establishment of HDR brachytherapy programs for gynecological malignancies in LMICs with varying levels of resources.


Asunto(s)
Braquiterapia , Neoplasias de los Genitales Femeninos , Neoplasias del Cuello Uterino , Femenino , Humanos , Estados Unidos , Braquiterapia/métodos , Neoplasias del Cuello Uterino/radioterapia , Neoplasias del Cuello Uterino/patología , Países en Desarrollo , Neoplasias de los Genitales Femeninos/radioterapia , Dosificación Radioterapéutica
4.
Brachytherapy ; 22(6): 697-708, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37690972

RESUMEN

α-particle targeted radionuclide therapy has shown promise for optimal cancer management, an exciting new era for brachytherapy. Alpha-emitting nuclides can have significant advantages over gamma- and beta-emitters due to their high linear energy transfer (LET). While their limited path length results in more specific tumor 0kill with less damage to surrounding normal tissues, their high LET can produce substantially more lethal double strand DNA breaks per radiation track than beta particles. Over the last decade, the physical and chemical attributes of Actinium-225 (225Ac) including its half-life, decay schemes, path length, and straightforward chelation ability has peaked interest for brachytherapy agent development. However, this has been met with challenges including source availability, accurate modeling for standardized dosimetry for brachytherapy treatment planning, and laboratory space allocation in the hospital setting for on-demand radiopharmaceuticals production. Current evidence suggests that a simple empirical approach based on 225Ac administered radioactivity may lead to inconsistent outcomes and toxicity. In this review article, we highlight the recent advances in 225Ac source production, dosimetry modeling, and current clinical studies.


Asunto(s)
Braquiterapia , Neoplasias , Humanos , Braquiterapia/métodos , Neoplasias/radioterapia , Radiofármacos/uso terapéutico , Actinio/uso terapéutico
5.
Med Phys ; 50(8): e946-e960, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37427750

RESUMEN

The introduction of model-based dose calculation algorithms (MBDCAs) in brachytherapy provides an opportunity for a more accurate dose calculation and opens the possibility for novel, innovative treatment modalities. The joint AAPM, ESTRO, and ABG Task Group 186 (TG-186) report provided guidance to early adopters. However, the commissioning aspect of these algorithms was described only in general terms with no quantitative goals. This report, from the Working Group on Model-Based Dose Calculation Algorithms in Brachytherapy, introduced a field-tested approach to MBDCA commissioning. It is based on a set of well-characterized test cases for which reference Monte Carlo (MC) and vendor-specific MBDCA dose distributions are available in a Digital Imaging and Communications in Medicine-Radiotherapy (DICOM-RT) format to the clinical users. The key elements of the TG-186 commissioning workflow are now described in detail, and quantitative goals are provided. This approach leverages the well-known Brachytherapy Source Registry jointly managed by the AAPM and the Imaging and Radiation Oncology Core (IROC) Houston Quality Assurance Center (with associated links at ESTRO) to provide open access to test cases as well as step-by-step user guides. While the current report is limited to the two most widely commercially available MBDCAs and only for 192 Ir-based afterloading brachytherapy at this time, this report establishes a general framework that can easily be extended to other brachytherapy MBDCAs and brachytherapy sources. The AAPM, ESTRO, ABG, and ABS recommend that clinical medical physicists implement the workflow presented in this report to validate both the basic and the advanced dose calculation features of their commercial MBDCAs. Recommendations are also given to vendors to integrate advanced analysis tools into their brachytherapy treatment planning system to facilitate extensive dose comparisons. The use of the test cases for research and educational purposes is further encouraged.


Asunto(s)
Braquiterapia , Braquiterapia/métodos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Informe de Investigación , Método de Montecarlo , Radiometría
6.
J Appl Clin Med Phys ; 24(11): e14090, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37464581

RESUMEN

PURPOSE: To evaluate the clinical feasibility of the Siemens Healthineers AI-Rad Companion Organs RT VA30A (Organs-RT) auto-contouring algorithm for organs at risk (OARs) of the pelvis, thorax, and head and neck (H&N). METHODS: Computed tomography (CT) datasets from 30 patients (10 pelvis, 10 thorax, and 10 H&N) were collected. Four sets of OARs were generated on each scan, one set by Organs-RT and the others by three experienced users independently. A physician (expert) then evaluated each contour by assigning a score from the following scale: 1-Must Redo, 2-Major Edits, 3-Minor Edits, 4-Clinically usable. Using the highest-scored OAR from the human users as a reference, the contours generated by Organs-RT were evaluated via Dice Similarity Coefficient (DSC), Hausdorff Distance (HDD), Mean Distance to Agreement (mDTA), Volume comparison, and visual inspection. Additionally, each human user recorded the time to delineate each structure set and time-saving efficiency was measured. RESULTS: The average DSC obtained for the pelvic OARs ranged between (0.81 ± 0.06)Rectum and (0.94 ± 0.03)Bladder . (0.75 ± 0.09)Esophagus to ( 0.96 ± 0.02 ) Rt . Lung ${( {0.96 \pm 0.02} )}_{{\mathrm{Rt}}.{\mathrm{\ Lung}}}$ for the thoracic OARs and (0.66 ± 0.07)Lips to (0.83 ± 0.04)Brainstem for the H&N. The average HDD in cm for the pelvis cohort ranged between (0.95 ± 0.35)Bladder to (3.62 ± 2.50)Rectum , (0.42 ± 0.06)SpinalCord to (2.09 ± 2.00)Esophagus for the thoracic set and ( 0.53 ± 0.22 ) Cerv _ SpinalCord ${( {0.53 \pm 0.22} )}_{{\mathrm{Cerv}}\_{\mathrm{SpinalCord}}}$ to (1.50 ± 0.50)Mandible for the H&N region. The time-saving efficiency was 67% for H&N, 83% for pelvis, and 84% for thorax. 72.5%, 82%, and 50% of the pelvis, thorax, and H&N OARs were scored as clinically usable by the expert, respectively. CONCLUSIONS: The highest agreement registered between OARs generated by Organs-RT and their respective references was for the bladder, heart, lungs, and femoral heads, with an overall DSC≥0.92. The poorest agreement was for the rectum, esophagus, and lips, with an overall DSC⩽0.81. Nonetheless, Organs-RT serves as a reliable auto-contouring tool by minimizing overall contouring time and increasing time-saving efficiency in radiotherapy treatment planning.


Asunto(s)
Aprendizaje Profundo , Humanos , Estudios de Factibilidad , Planificación de la Radioterapia Asistida por Computador/métodos , Algoritmos , Cuello , Órganos en Riesgo
7.
Med Phys ; 50(7): 4675-4687, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37194638

RESUMEN

PURPOSE: To provide the first clinical test case for commissioning of 192 Ir brachytherapy model-based dose calculation algorithms (MBDCAs) according to the AAPM TG-186 report workflow. ACQUISITION AND VALIDATION METHODS: A computational patient phantom model was generated from a clinical multi-catheter 192 Ir HDR breast brachytherapy case. Regions of interest (ROIs) were contoured and digitized on the patient CT images and the model was written to a series of DICOM CT images using MATLAB. The model was imported into two commercial treatment planning systems (TPSs) currently incorporating an MBDCA. Identical treatment plans were prepared using a generic 192 Ir HDR source and the TG-43-based algorithm of each TPS. This was followed by dose to medium in medium calculations using the MBDCA option of each TPS. Monte Carlo (MC) simulation was performed in the model using three different codes and information parsed from the treatment plan exported in DICOM radiation therapy (RT) format. Results were found to agree within statistical uncertainty and the dataset with the lowest uncertainty was assigned as the reference MC dose distribution. DATA FORMAT AND USAGE NOTES: The dataset is available online at http://irochouston.mdanderson.org/rpc/BrachySeeds/BrachySeeds/index.html,https://doi.org/10.52519/00005. Files include the treatment plan for each TPS in DICOM RT format, reference MC dose data in RT Dose format, as well as a guide for database users and all files necessary to repeat the MC simulations. POTENTIAL APPLICATIONS: The dataset facilitates the commissioning of brachytherapy MBDCAs using TPS embedded tools and establishes a methodology for the development of future clinical test cases. It is also useful to non-MBDCA adopters for intercomparing MBDCAs and exploring their benefits and limitations, as well as to brachytherapy researchers in need of a dosimetric and/or a DICOM RT information parsing benchmark. Limitations include specificity in terms of radionuclide, source model, clinical scenario, and MBDCA version used for its preparation.


Asunto(s)
Braquiterapia , Humanos , Dosificación Radioterapéutica , Braquiterapia/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Radiometría , Mama/diagnóstico por imagen , Método de Montecarlo
8.
Pract Radiat Oncol ; 13(1): 41-65, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36280107

RESUMEN

PURPOSE: With the results of several recently published clinical trials, this guideline informs on the use of adjuvant radiation therapy (RT) and systemic therapy in the treatment of endometrial cancer. Updated evidence-based recommendations provide indications for adjuvant RT and the associated techniques, the utilization and sequencing of adjuvant systemic therapies, and the effect of surgical staging techniques and molecular tumor profiling. METHODS: The American Society for Radiation Oncology convened a multidisciplinary task force to address 6 key questions that focused on the adjuvant management of patients with endometrial cancer. The key questions emphasized the (1) indications for adjuvant RT, (2) RT techniques, target volumes, dose fractionation, and treatment planning aims, (3) indications for systemic therapy, (4) sequencing of systemic therapy with RT, (5) effect of lymph node assessment on utilization of adjuvant therapy, and (6) effect of molecular tumor profiling on utilization of adjuvant therapy. Recommendations were based on a systematic literature review and created using a predefined consensus-building methodology and system for quality of evidence grading and strength of recommendation. RESULTS: The task force recommends RT (either vaginal brachytherapy or external beam RT) be given based on the patient's clinical-pathologic risk factors to reduce risk of vaginal and/or pelvic recurrence. When external beam RT is delivered, intensity modulated RT with daily image guided RT is recommended to reduce acute and late toxicity. Chemotherapy is recommended for patients with International Federation of Gynecology and Obstetrics (FIGO) stage I to II with high-risk histologies and those with FIGO stage III to IVA with any histology. When sequencing chemotherapy and RT, there is no prospective data to support an optimal sequence. Sentinel lymph node mapping is recommended over pelvic lymphadenectomy for surgical nodal staging. Data on sentinel lymph node pathologic ultrastaging status supports that patients with isolated tumor cells be treated as node negative and adjuvant therapy based on uterine risk factors and patients with micrometastases be treated as node positive. The available data on molecular characterization of endometrial cancer are compelling and should be increasingly considered when making recommendations for adjuvant therapy. CONCLUSIONS: These recommendations guide evidence-based best clinical practices on the use of adjuvant therapy for endometrial cancer.


Asunto(s)
Braquiterapia , Neoplasias Endometriales , Oncología por Radiación , Radioterapia de Intensidad Modulada , Femenino , Humanos , Estados Unidos , Neoplasias Endometriales/patología , Braquiterapia/métodos , Terapia Combinada , Estadificación de Neoplasias , Radioterapia Adyuvante/métodos
10.
Med Phys ; 49(8): e983-e1023, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35662032

RESUMEN

The task group (TG) on magnetic resonance imaging (MRI) implementation in high-dose-rate (HDR) brachytherapy (BT)-Considerations from simulation to treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR BT workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT-related TG reports, and new image-guided recommendations beyond CT-based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA, an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society.


Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Braquiterapia/métodos , Humanos , Imagen por Resonancia Magnética/métodos , Masculino , Próstata , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/radioterapia , Dosificación Radioterapéutica , Estados Unidos
11.
Brachytherapy ; 21(5): 569-591, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35599080

RESUMEN

PURPOSE: To develop a multidisciplinary consensus for high quality multidisciplinary implementation of brachytherapy using Yttrium-90 (90Y) microspheres transarterial radioembolization (90Y TARE) for primary and metastatic cancers in the liver. METHODS AND MATERIALS: Members of the American Brachytherapy Society (ABS) and colleagues with multidisciplinary expertise in liver tumor therapy formulated guidelines for 90Y TARE for unresectable primary liver malignancies and unresectable metastatic cancer to the liver. The consensus is provided on the most recent literature and clinical experience. RESULTS: The ABS strongly recommends the use of 90Y microsphere brachytherapy for the definitive/palliative treatment of unresectable liver cancer when recommended by the multidisciplinary team. A quality management program must be implemented at the start of 90Y TARE program development and follow-up data should be tracked for efficacy and toxicity. Patient-specific dosimetry optimized for treatment intent is recommended when conducting 90Y TARE. Implementation in patients on systemic therapy should account for factors that may enhance treatment related toxicity without delaying treatment inappropriately. Further management and salvage therapy options including retreatment with 90Y TARE should be carefully considered. CONCLUSIONS: ABS consensus for implementing a safe 90Y TARE program for liver cancer in the multidisciplinary setting is presented. It builds on previous guidelines to include recommendations for appropriate implementation based on current literature and practices in experienced centers. Practitioners and cooperative groups are encouraged to use this document as a guide to formulate their clinical practices and to adopt the most recent dose reporting policies that are critical for a unified outcome analysis of future effectiveness studies.


Asunto(s)
Braquiterapia , Carcinoma Hepatocelular , Embolización Terapéutica , Neoplasias Hepáticas , Braquiterapia/métodos , Carcinoma Hepatocelular/terapia , Embolización Terapéutica/métodos , Humanos , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundario , Microesferas , Estados Unidos , Radioisótopos de Itrio/uso terapéutico
12.
Brachytherapy ; 21(3): 362-368, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35249823

RESUMEN

PURPOSE: To evaluate the prevalence of burnout among brachytherapy specialists and to identify factors associated with burnout. METHODS AND MATERIALS: An anonymous, online, cross-sectional survey was administered to non-trainee physician members of the American Brachytherapy Society. Burnout was evaluated using the validated Maslach Burnout Inventory-Human Services Survey (MBI-HSS). Demographic and practice-specific questions were collected from respondents. Univariate and multivariable analysis of outcomes were performed using probabilistic index models. RESULTS: Overall, 51 of 400 physicians responded (13% response rate). Fifty-seven percent of respondents demonstrated at least one symptom of professional burnout. However, only 6% of respondents met strict criteria for high burnout. Analysis of the individual MBI-HSS subdomains demonstrated higher subscale scores for emotional exhaustion and depersonalization, but also higher scores for personal accomplishment. On multivariable analysis after adjusting for increased feelings of burnout due to the COVID-19 pandemic or total hours of work per week, younger age was associated with both increased subscale scores for emotional exhaustion (p = 0.026) and lower personal accomplishment (p = 0.010). Lastly, nearly half of all respondents (47%) reported increased feelings of burnout due to the COVID-19 pandemic. Respondents from academic facilities were significantly more likely to report increased burnout due to COVID-19 compared to those from non-academic facilities (odds ratio, 7.04; 95% CI 1.60-31.0; p = 0.010). CONCLUSIONS: Nearly 60% of brachytherapists demonstrated symptoms of professional burnout, which is higher than other radiation oncology groups (academic chairs, program directors, residents). Managing stressors related to workload, COVID and support for junior physicians are potential areas for improving feelings of burnout.


Asunto(s)
Braquiterapia , Agotamiento Profesional , COVID-19 , Médicos , Braquiterapia/métodos , Agotamiento Profesional/diagnóstico , Agotamiento Profesional/epidemiología , Agotamiento Profesional/psicología , Estudios Transversales , Humanos , Satisfacción en el Trabajo , Pandemias , Prevalencia , Encuestas y Cuestionarios , Estados Unidos/epidemiología
13.
Brachytherapy ; 21(1): 63-74, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34732290

RESUMEN

PURPOSE: Brachytherapy is an essential technique to deliver radiation therapy and is involved in the treatment of multiple disease sites as monotherapy or as an adjunct to external beam radiation therapy. With a growing focus on the cost and value of cancer treatments as well as new payment models, it is essential that standardized quality measures and metrics exist to allow for straightforward assessment of brachytherapy quality and for the development of clinically significant and relevant clinical data elements. We present the American Brachytherapy Society consensus statement on quality measures and metrics for brachytherapy as well as suggested clinical data elements. METHODS AND MATERIALS: Members of the American Brachytherapy Society with expertise in disease site specific brachytherapy created a consensus statement based on a literature review and clinical experience. RESULTS: Key quality measures (ex. workup, clinical indications), dosimetric metrics, and clinical data elements for brachytherapy were evaluated for each modality including breast cancer, cervical cancer, endometrial cancer, prostate cancer, keratinocyte carcinoma, soft tissue sarcoma, and uveal melanoma. CONCLUSIONS: This consensus statement provides standardized quality measures and dosimetric quality metrics as well as clinical data elements for each disease site to allow for standardized assessments of brachytherapy quality. Moving forward, a similar paradigm can be considered for external beam radiation therapy as well, providing comprehensive radiation therapy quality measures, metrics, and clinical data elements that can be incorporated into new payment models.


Asunto(s)
Braquiterapia , Oncología por Radiación , Neoplasias de la Úvea , Benchmarking , Braquiterapia/métodos , Humanos , Masculino , Indicadores de Calidad de la Atención de Salud , Estados Unidos
14.
JCO Oncol Pract ; 17(12): e1958-e1967, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34550749

RESUMEN

PURPOSE: Cervical cancer (CC) disproportionately affects minorities who have higher incidence and mortality rates. Standard of care for locally advanced CC involves a multimodality approach including brachytherapy (BT), which independently improves oncologic outcomes. Here, we examine the impact of insurance status and race on BT utilization with the SEER database. MATERIALS AND METHODS: In total, 7,266 patients with stage I-IV CC diagnosed from 2007 to 2015 were included. BT utilization, overall survival (OS), and disease-specific survival (DSS) were compared. RESULTS: Overall, 3,832 (52.7%) received combined external beam radiation therapy (EBRT) + BT, whereas 3,434 (47.3%) received EBRT alone. On multivariate logistic regression analysis, increasing age (OR, 0.98; 95% CI, 0.98 to 0.99; P < .001); Medicaid (OR, 0.80; 95% CI, 0.72 to 0.88; P < .001), uninsured (OR, 0.67; 95% CI, 0.56 to 0.80; P < .001), and unknown versus private insurance (OR, 0.61; 95% CI, 0.43 to 0.86; P < .001); Black (OR, 0.68; 95% CI, 0.60 to 0.77; P < .001) and unknown versus White race (OR, 0.30; 95% CI, 0.13 to 0.77; P = .047); and American Joint Committee on Cancer stage II (OR, 1.07; 95% CI, 0.93 to 1.24; P = .36), stage III (OR, 0.82; 95% CI, 0.71 to 0.94; P = .006), stage IV (OR, 0.30; 95% CI, 0.23 to 0.40; P < .001), and unknown stage versus stage I (OR, 0.36; 95% CI, 0.28 to 0.45; P < .001) were associated with decreased BT utilization. When comparing racial survival differences, the 5-year OS was 44.2% versus 50.9% (P < .0001) and the 5-year DSS was 55.6% versus 60.5% (P < .0001) for Black and White patients, respectively. Importantly, the racial survival disparities resolved when examining patients who received combined EBRT + BT, with the 5-year OS of 57.3% versus58.5% (P = .24) and the 5-year DSS of 66.3% versus 66.6% (P = .53) for Black and White patients, respectively. CONCLUSION: This work demonstrates notable inequities in BT utilization for CC that particularly affects patients of lower insurance status and Black race, which translates into inferior oncologic outcomes. Importantly, the use of BT was able to overcome racial survival differences, thus highlighting its essential value.


Asunto(s)
Braquiterapia , Neoplasias del Cuello Uterino , Femenino , Humanos , Estudios Retrospectivos , Factores Socioeconómicos , Estados Unidos/epidemiología , Neoplasias del Cuello Uterino/radioterapia
15.
Brachytherapy ; 20(6): 1071-1082, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34588143

RESUMEN

PURPOSE: This practice parameter aims to detail the processes, qualifications of personnel, patient selection, equipment, patient and personnel safety, documentation, and quality control and improvement necessary for an HDR brachytherapy program. METHODS AND MATERIALS: This practice parameter was revised collaboratively by the American College of Radiology (ACR), the American Brachytherapy Society (ABS), and the American Society for Radiation Oncology (ASTRO). RESULTS: Brachytherapy is a radiotherapeutic modality in which radionuclide or electronic sources are used to deliver a radiation dose at a distance of up to a few centimeters by surface, intracavitary, intraluminal, or interstitial application. Brachytherapy alone or combined with external beam radiotherapy plays an important role in the management and treatment of patients with cancer. High-dose-rate (HDR) brachytherapy uses radionuclides, such as iridium-192, at dose rates of ≥12 Gy/hr to a designated target point or volume, and it is an important treatment for a variety of malignant and benign conditions. Its use allows for application of high doses of radiation to defined target volumes with relative sparing of adjacent critical structures. CONCLUSIONS: HDR brachytherapy requires detailed attention to personnel, equipment, patient and personnel safety, and continuing staff education. Coordination between the radiation oncologist and treatment planning staff and effective quality assurance procedures are important components of successful HDR brachytherapy programs.


Asunto(s)
Braquiterapia , Neoplasias , Oncología por Radiación , Braquiterapia/métodos , Humanos , Radioisótopos , Dosificación Radioterapéutica , Sociedades Médicas
17.
Brachytherapy ; 20(6): 1114-1129, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34509378

RESUMEN

PURPOSE: The purpose of this guideline is to present evidence-based consensus recommendations for low dose rate (LDR) permanent seed brachytherapy for the primary treatment of prostate cancer. METHODS AND MATERIALS: The American Brachytherapy Society convened a task force for addressing key questions concerning ultrasound-based LDR prostate brachytherapy for the primary treatment of prostate cancer. A comprehensive literature search was conducted to identify prospective and multi-institutional retrospective studies involving LDR brachytherapy as monotherapy or boost in combination with external beam radiation therapy with or without adjuvant androgen deprivation therapy. Outcomes included disease control, toxicity, and quality of life. RESULTS: LDR prostate brachytherapy monotherapy is an appropriate treatment option for low risk and favorable intermediate risk disease. LDR brachytherapy boost in combination with external beam radiation therapy is appropriate for unfavorable intermediate risk and high-risk disease. Androgen deprivation therapy is recommended in unfavorable intermediate risk and high-risk disease. Acceptable radionuclides for LDR brachytherapy include iodine-125, palladium-103, and cesium-131. Although brachytherapy monotherapy is associated with increased urinary obstructive and irritative symptoms that peak within the first 3 months after treatment, the median time toward symptom resolution is approximately 1 year for iodine-125 and 6 months for palladium-103. Such symptoms can be mitigated with short-term use of alpha blockers. Combination therapy is associated with worse urinary, bowel, and sexual symptoms than monotherapy. A prostate specific antigen <= 0.2 ng/mL at 4 years after LDR brachytherapy may be considered a biochemical definition of cure. CONCLUSIONS: LDR brachytherapy is a convenient, effective, and well-tolerated treatment for prostate cancer.


Asunto(s)
Braquiterapia , Neoplasias de la Próstata , Antagonistas de Andrógenos , Braquiterapia/métodos , Consenso , Humanos , Masculino , Estudios Prospectivos , Antígeno Prostático Específico , Neoplasias de la Próstata/radioterapia , Calidad de Vida , Estudios Retrospectivos
18.
Brachytherapy ; 20(6): 1200-1218, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34303600

RESUMEN

PURPOSE: Growing data supports the role of radiation therapy in the treatment of soft tissue sarcoma (STS). Brachytherapy has been used for decades in the management of STS and can be utilized as monotherapy or as a boost to external beam radiation. We present updated guidelines from the American Brachytherapy Society regarding the utilization of brachytherapy in the management of STS. METHODS AND MATERIALS: Members of the American Brachytherapy Society with expertise in STS and STS brachytherapy created an updated clinical practice guideline including step-by-step details for performing STS brachytherapy based on a literature review and clinical experience. RESULTS: Brachytherapy monotherapy should be considered for lower-recurrence risk patients or after a local recurrence following previous external beam radiation; a brachytherapy boost can be considered in higher-risk patents meeting implant criteria. Multiple dose/fractionation regimens are available, with determination based on tumor location and treatment intent. Techniques to limit wound complications are based on the type of wound closure; wound complication can be mitigated with a delay in the start of brachytherapy with immediate wound closure or by utilizing a staged reconstruction technique, which allows an earlier treatment start with a delayed wound closure. CONCLUSIONS: These updated guidelines provide clinicians with data on indications for STS brachytherapy as well as guidelines on how to perform and deliver high quality STS brachytherapy safely with minimal toxicity.


Asunto(s)
Braquiterapia , Sarcoma , Neoplasias de los Tejidos Blandos , Braquiterapia/métodos , Consenso , Fraccionamiento de la Dosis de Radiación , Humanos , Sarcoma/radioterapia , Estados Unidos
19.
Int J Radiat Oncol Biol Phys ; 109(3): 834-835, 2021 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-33516444
20.
Brachytherapy ; 19(6): 787-793, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33132070

RESUMEN

PURPOSE: Education and training on prostate brachytherapy for radiation oncology and medical physics residents in the United States is inadequate, resulting in fewer competent radiation oncology personnel to perform implants, and is a factor in the subsequent decline of an important, potentially curative cancer treatment modality for patients with cancer. The American Brachytherapy Society (ABS) leadership has recognized the need to establish a sustainable medical simulation low-dose-rate (LDR) and high-dose-rate (HDR) brachytherapy workshop program that includes physician-physicist teams to rapidly translate knowledge to establish high-quality brachytherapy programs. METHODS: The ABS, in partnership with industry and academia, has held three radiation oncology team-based LDR/HDR workshops composed of physician-physicist teams in Chicago in 2017, in Houston in 2018, and in Denver in 2019. The predefined key metric of success is the number of attendees who returned to their respective institutions and were actively performing brachytherapy within 6 months of the prostate brachytherapy workshop. RESULTS: Of the 111 physician/physicist teams participating in the Chicago, Houston, and Denver prostate brachytherapy workshops, 87 (78%) were actively performing prostate brachytherapy (51 [59%] HDR and 65 [75%] LDR). CONCLUSIONS: The ABS prostate brachytherapy LDR/HDR simulation workshop has provided a successful education and training structure for medical simulation of the critical procedural steps in quality assurance to shorten the learning curve for delivering consistently high-quality brachytherapy implants for patients with prostate cancer. An ABS initiative, intended to bend the negative slope of the brachytherapy curve, is currently underway to train 300 new competent brachytherapy teams over the next 10 years.


Asunto(s)
Braquiterapia/normas , Educación Médica Continua/métodos , Neoplasias de la Próstata/radioterapia , Garantía de la Calidad de Atención de Salud , Oncología por Radiación/educación , Sociedades Médicas , Braquiterapia/métodos , Braquiterapia/estadística & datos numéricos , Competencia Clínica , Humanos , Masculino , Médicos , Dosificación Radioterapéutica , Entrenamiento Simulado , Estados Unidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...