Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Cancers (Basel) ; 15(22)2023 Nov 16.
Artículo en Inglés | MEDLINE | ID: mdl-38001697

RESUMEN

Assessment of regional lymph node status in breast cancer is of important staging and prognostic value. Even though formal histological examination is the currently accepted standard of care, optical imaging techniques have shown promising results in disease diagnosis. In the present article, we review six spectroscopic techniques and focus on their use as alternative tools for breast cancer lymph node assessment. Elastic scattering spectroscopy (ESS) seems to offer a simple, cost-effective, and reproducible method for intraoperative diagnosis of breast cancer lymph node metastasis. Optical coherence tomography (OCT) provides high-resolution tissue scanning, along with a short data acquisition time. However, it is relatively costly and experimentally complex. Raman spectroscopy proves to be a highly accurate method for the identification of malignant axillary lymph nodes, and it has been further validated in the setting of head and neck cancers. Still, it remains time-consuming. Near-infrared fluorescence imaging (NIRF) and diffuse reflectance spectroscopy (DFS) are related to significant advantages, such as deep tissue penetration and efficiency. Fourier-transform infrared spectroscopy (FTIR) is a promising method but has significant drawbacks. Nonetheless, only anecdotal reports exist on their clinical use for cancerous lymph node detection. Our results indicate that optical imaging methods can create informative and rapid tools to effectively guide surgical decision-making.

2.
Int J Mol Sci ; 23(10)2022 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-35628452

RESUMEN

Broadband dielectric spectroscopy in a broad temperature range was employed to study ionic conductivity and dynamics in tetraalkylammonium- and tetraalkylphosphonium-based ionic liquids (ILs) having levulinate as a common anion. Combining data for ionic conductivity with data obtained for viscosity in a Walden plot, we show that ionic conductivity is controlled by viscosity while a strong association of ions takes place. Higher values for ionic conductivities in a broad temperature range were found for the tetraalkylphosphonium-based IL compared to its ammonium homolog in accordance with its lower viscosity. Levulinate used in the present study as anion was found to interact and associate stronger with the cations forming ion-pairs or other complexes compared to the NTf2 anion studied in literature. In order to analyze dielectric data, different fitting approaches were employed. The original random barrier model cannot well describe the conductivity especially at the higher frequencies region. In electric modulus representation, two overlapping mechanisms contribute to the broad low frequencies peak. The slower process is related to the conduction mechanism and the faster to the main polarization process of the complex dielectric permittivity representation. The correlation of the characteristic time scales of the previous relaxation processes was discussed in terms of ionic interactions.


Asunto(s)
Líquidos Iónicos , Aniones , Conductividad Eléctrica , Líquidos Iónicos/química , Iones/química , Cetoácidos , Viscosidad
3.
Lasers Med Sci ; 37(6): 2597-2604, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35301608

RESUMEN

We report differences in the refractive index of healthy and tumorous freshly excised human breast tissue as determined from reflectance profile measurements at five wavelengths (432 nm, 532 nm, 633 nm, 964 nm, 1551 nm) in the visible and near-infrared using a standard prism-coupling refractometer. These refractive index differences, particularly in the near-infrared, can be used to distinguish fibroadenomas and cancerous growths not only from normal breast tissue but also from each other.


Asunto(s)
Neoplasias de la Mama , Refractometría , Biomarcadores , Mama , Femenino , Humanos
4.
J Biophotonics ; 10(2): 303-310, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27091794

RESUMEN

A multi-wavelength prism coupling refractometer is utilized to measure the angular reflectance of freshly excised human intestinal tissue specimens. Based on reflectance data, the real and imaginary part of the refractive index is calculated via Fresnel analysis for three visible (blue, green, red) and two near-infrared (963 nm and 1551 nm) wavelengths. Averaged values of the complex refractive index and corresponding Cauchy dispersion fits are given for the mucosa, submucosa and serosa layers of the colorectal wall at the normal state. The refractive constants of tumorous and normal mucosa are then cross-compared for the indicative cases of one patient diagnosed with a benign polyp and three patients diagnosed with adenocarcinomas of different phenotype. Significant index contrast exists between the normal and diseased states, indicating the potential use of refractive index as a marker of colorectal dysplasia.


Asunto(s)
Neoplasias Colorrectales/diagnóstico por imagen , Refractometría , Espectroscopía Infrarroja Corta , Humanos
5.
Sci Rep ; 6: 27910, 2016 06 14.
Artículo en Inglés | MEDLINE | ID: mdl-27297034

RESUMEN

The refractive index is an optical constant that plays a significant role in the description of light-matter interactions. When it comes to biological media, refraction is understudied despite recent advances in the field of bio-optics. In the present article, we report on the measurement of the refractive properties of freshly excised healthy and cancerous human liver samples, by use of a prism-coupling technique covering the visible and near-infrared spectral range. Novel data on the wavelength-dependent complex refractive index of human liver tissues are presented. The magnitude of the real and imaginary part of the refractive index is correlated with hepatic pathology. Notably, the real index contrast is pointed out as a marker of discrimination between normal liver tissue and hepatic metastases. In view of the current progress in optical biosensor technologies, our findings may be exploited for the development of novel surgical and endoscopic tools.


Asunto(s)
Carcinoma Hepatocelular/química , Neoplasias Hepáticas/química , Hígado/química , Refractometría/métodos , Biomarcadores de Tumor , Técnicas Biosensibles , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/patología , Endoscopía , Hepatectomía , Humanos , Hígado/patología , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/patología , Espectroscopía Infrarroja Corta
6.
Opt Express ; 14(5): 1905-12, 2006 Mar 06.
Artículo en Inglés | MEDLINE | ID: mdl-19503520

RESUMEN

We report on highly efficient second, third and fourth harmonic generation from a femtosecond erbium-doped fiber source operating at 98 MHz repetition rate. By use of quasi-phase-matching in fan-out poled MgO:LiNbO(3), we generate pulses at 770 nm, 520 nm and 390 nm, with corresponding average powers of 120 mW, 55 mW and 6 mW, respectively. Our device can be employed as a two-color source providing radiation from ultraviolet to near infrared.

7.
Opt Express ; 12(24): 5872-80, 2004 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-19488226

RESUMEN

We present a highly versatile approach to the application of femtosecond Er:fiber lasers in optical frequency metrology. Our concept relies on the implementation of two parallel amplifiers, seeded by a single master oscillator. With the comb spacing locked to a frequency of 100 MHz, we apply the output from the first amplifier to generate a feedback signal to achieve a simultaneous phase-lock for the comb offset frequency. The output of the independently configurable second amplifier enables precision frequency measurements in the visible and near-infrared. As a first application, we continuously measure the absolute frequency of a resonator-stabilized diode laser over a period of 88 hours.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA