Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Br Dent J ; 2021 Aug 24.
Artículo en Inglés | MEDLINE | ID: mdl-34446842

RESUMEN

Aim To calculate fallow time (FT) required following dental aerosol generating procedures (AGPs) in both a dental hospital (mechanically ventilated) and primary care (non-mechanically ventilated). Secondary outcomes were to identify spread and persistence of aerosol in open clinics compared to closed surgeries (mechanically ventilated environment), and identify if extraoral scavenging (EOS) reduces FT and production of aerosol.Methods In vitro simulation of fast handpiece cavity preparations using a manikin was conducted in a mechanically and non-mechanically ventilated environment using Optical Particle Sizer and NanoScan at baseline, during the procedure and fallow period.Results AGPs carried out in the non-mechanically, non-ventilated environment failed to achieve baseline particle levels after one hour. In contrast, when windows were opened after AGPs, there was an immediate reduction in all particle sizes. In mechanically ventilated environments, the baseline levels of particles were very low and particle count returned to baseline within ten minutes following the AGP. There was no detectable difference between particles in mechanically ventilated open bays and closed surgeries. The effect of the EOS on reducing the particle count was greater in the non-mechanically ventilated environment; additionally, it also reduced the spikes in particle counts in mechanically ventilated environments.Conclusion High-efficiency particulate, air-filtered mechanical ventilation, along with mitigation (high-volume suction), resulted in reduction of fallow time (ten minutes). Non-ventilated rooms failed to reach baseline level even after one hour of fallow time. There was no difference in particle counts in open bays or closed surgeries in mechanically ventilated settings with an extraoral suction device reducing particulate spikes. This study confirms that AGPs are not recommended in dental surgeries where no ventilation is possible.

2.
Br Dent J ; 2020 Nov 12.
Artículo en Inglés | MEDLINE | ID: mdl-33184480

RESUMEN

Introduction Transmission of SARS-CoV-2 through aerosol has been suggested, particularly in the presence of highly concentrated aerosols in enclosed environments. It is accepted that aerosols are produced during a range of dental procedures, posing potential risks to both dental practitioners and patients. There has been little agreement concerning aerosol transmission associated with orthodontics and associated mitigation.Methods Orthodontic procedures were simulated in a closed side-surgery using a dental manikin on an acrylic model using composite-based adhesive. Adhesive removal representing debonding was undertaken using a 1:1 contra-angle handpiece (W&H Synea Vision WK-56 LT, Bürmoos, Austria) and fast handpiece with variation in air and water flow. The removal of acid etch was also simulated with the use of combined 3-in-1 air-water syringe. An optical particle sizer (OPS 3330, TSI Inc., Minnesota, USA) and a portable scanning mobility particle sizer (NanoScan SMPS Nanoparticle Sizer 3910, TSI Inc., Minnesota, USA) were both used to assess particulate matter ranging in dimension from 0.08 to 10 µm.Results Standard debonding procedure (involving air but no water) was associated with clear increase in the 'very small' and 'small' (0.26-0.9 µm) particles but only for a short period. Debonding procedures without supplementary air coolant appeared to produce similar levels of aerosol to standard debonding. Debonding in association with water tended to produce large increases in aerosol levels, producing particles of all sizes throughout the experiment. The use of water and a fast handpiece led to the most significant increase in particles. Combined use of the 3-in-1 air-water syringe did not result in any detectable increase in the aerosol levels.Conclusions Particulate matter was released during orthodontic debonding, although the concentration and volume was markedly less than that associated with the use of a fast handpiece. No increase in particulates was associated with prolonged use of a 3-in-1 air-water syringe. Particulate levels reduced to baseline levels over a short period (approximately five minutes). Further research within alternative, open environments and without air exchange systems is required.

3.
Br Dent J ; 2020 Sep 11.
Artículo en Inglés | MEDLINE | ID: mdl-32918060

RESUMEN

Introduction This study was conducted in light of the SARS-CoV-2 pandemic, which brought UK dentistry to a standstill. The market has seen a recent influx of unproven extraoral scavengers (EOSs), which claim to reduce the risk of particulate spread.Aims To investigate the efficacy of a commercially available EOS device on contamination reduction during dental aerosol generating procedures (AGPs). The secondary aim was to investigate differences between open and closed dental operatories.Method Dental procedures were simulated on a dental manikin using citric acid (10%) added to the water lines with universal indicating paper (UIP) placed in strategic locations in the operatory, on the clinician and assistant. Chromatic change related to settling of splatter containing citric acid on the UIP was analysed to calculate percentage intensity of splatter contamination.Results EOSs resulted in 20% reduction in frequency and 75% reduction in mean intensity of contamination of operatory sites. There was a 33% and 76% reduction in mean intensity contamination for clinician and assistant, respectively. Use of rubber dam and four-handed dentistry resulted in further reduction.Discussion This exploratory study demonstrates contamination by splatter in a simulated dental setting. The concern in dentistry regarding aerosol requires further quantitative investigation of smaller particles.Conclusions The routine use of four-handed dentistry and rubber dam should continue where possible to maximise risk mitigation during AGPs. However, on the basis of our findings, the use of an EOS device can further mitigate the magnitude and concentration of splatter.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...