Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-34360343

RESUMEN

COVID-19 and pneumonia detection using medical images is a topic of immense interest in medical and healthcare research. Various advanced medical imaging and machine learning techniques have been presented to detect these respiratory disorders accurately. In this work, we have proposed a novel COVID-19 detection system using an exemplar and hybrid fused deep feature generator with X-ray images. The proposed Exemplar COVID-19FclNet9 comprises three basic steps: exemplar deep feature generation, iterative feature selection and classification. The novelty of this work is the feature extraction using three pre-trained convolutional neural networks (CNNs) in the presented feature extraction phase. The common aspects of these pre-trained CNNs are that they have three fully connected layers, and these networks are AlexNet, VGG16 and VGG19. The fully connected layer of these networks is used to generate deep features using an exemplar structure, and a nine-feature generation method is obtained. The loss values of these feature extractors are computed, and the best three extractors are selected. The features of the top three fully connected features are merged. An iterative selector is used to select the most informative features. The chosen features are classified using a support vector machine (SVM) classifier. The proposed COVID-19FclNet9 applied nine deep feature extraction methods by using three deep networks together. The most appropriate deep feature generation model selection and iterative feature selection have been employed to utilise their advantages together. By using these techniques, the image classification ability of the used three deep networks has been improved. The presented model is developed using four X-ray image corpora (DB1, DB2, DB3 and DB4) with two, three and four classes. The proposed Exemplar COVID-19FclNet9 achieved a classification accuracy of 97.60%, 89.96%, 98.84% and 99.64% using the SVM classifier with 10-fold cross-validation for four datasets, respectively. Our developed Exemplar COVID-19FclNet9 model has achieved high classification accuracy for all four databases and may be deployed for clinical application.


Asunto(s)
COVID-19 , Humanos , Aprendizaje Automático , Redes Neurales de la Computación , SARS-CoV-2 , Rayos X
2.
J Med Imaging Radiat Sci ; 52(2): 257-264, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-33531272

RESUMEN

INTRODUCTION: Fixed volume (FV) contrast media administration during CT examination is the standard practice in most healthcare institutions. We aim to validate a customised weight-based volume (WBV) method and compare it to the conventional FV methods, introduced in a regional setting. METHODS: 220 patients underwent CT of the chest, abdomen and pelvis (CAP) using a standard FV protocol, and subsequently, a customised 1.0 mL/kg WBV protocol within one year. Both image sets were assessed for contrast enhancement using CT attenuation at selected regions-of-interest (ROIs). The visual image quality was evaluated by three radiologists using a 4-point Likert scale. Quantitative CT attenuation was correlated with the visual quality assessment to determine the HU's enhancement indicative of the image quality grades. Contrast media usage was calculated to estimate cost-savings from both protocols. RESULTS: Mean patient age was 61 ± 14 years, and weight was 56.1 ± 8.7 kg. FV protocol produced higher contrast enhancement than WBV, p < 0.001. CT images' overall contrast enhancement was negatively correlated with body weight for FV protocol while the WBV protocol produced more consistent enhancement across different body weight. More than 90% of the images from both protocols were graded "Excellent". WBV protocol also enabled a 28% cost reduction with cost savings of US$1238. CONCLUSION: The customised WBV protocol produced CT images which were comparable to FV protocol for CT CAP examinations. A median CT value of 100 HU can be an indicator of good image quality for the WBV protocol.


Asunto(s)
Abdomen , Medios de Contraste , Anciano , Humanos , Persona de Mediana Edad , Pelvis/diagnóstico por imagen , Estudios Prospectivos , Tomografía Computarizada por Rayos X
3.
PLoS One ; 16(1): e0244354, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33428651

RESUMEN

OBJECTIVES: To propose a novel robust radiogenomics approach to the identification of epidermal growth factor receptor (EGFR) mutations among patients with non-small cell lung cancer (NSCLC) using Betti numbers (BNs). MATERIALS AND METHODS: Contrast enhanced computed tomography (CT) images of 194 multi-racial NSCLC patients (79 EGFR mutants and 115 wildtypes) were collected from three different countries using 5 manufacturers' scanners with a variety of scanning parameters. Ninety-nine cases obtained from the University of Malaya Medical Centre (UMMC) in Malaysia were used for training and validation procedures. Forty-one cases collected from the Kyushu University Hospital (KUH) in Japan and fifty-four cases obtained from The Cancer Imaging Archive (TCIA) in America were used for a test procedure. Radiomic features were obtained from BN maps, which represent topologically invariant heterogeneous characteristics of lung cancer on CT images, by applying histogram- and texture-based feature computations. A BN-based signature was determined using support vector machine (SVM) models with the best combination of features that maximized a robustness index (RI) which defined a higher total area under receiver operating characteristics curves (AUCs) and lower difference of AUCs between the training and the validation. The SVM model was built using the signature and optimized in a five-fold cross validation. The BN-based model was compared to conventional original image (OI)- and wavelet-decomposition (WD)-based models with respect to the RI between the validation and the test. RESULTS: The BN-based model showed a higher RI of 1.51 compared with the models based on the OI (RI: 1.33) and the WD (RI: 1.29). CONCLUSION: The proposed model showed higher robustness than the conventional models in the identification of EGFR mutations among NSCLC patients. The results suggested the robustness of the BN-based approach against variations in image scanner/scanning parameters.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas/diagnóstico , Procesamiento de Imagen Asistido por Computador/métodos , Neoplasias Pulmonares/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Área Bajo la Curva , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/genética , Receptores ErbB/genética , Femenino , Humanos , Japón , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/genética , Malasia , Masculino , Persona de Mediana Edad , Mutación , Curva ROC , Máquina de Vectores de Soporte , Tomografía Computarizada por Rayos X , Estados Unidos
4.
Medicine (Baltimore) ; 99(39): e22405, 2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-32991467

RESUMEN

This study aims to compare Quantra, as an automated volumetric breast density (Vbd) tool, with visual assessment according to ACR BI-RADS density categories and to determine its potential usage in clinical practice.Five hundred randomly selected screening and diagnostic mammograms were included in this retrospective study. Three radiologists independently assigned qualitative ACR BI-RADS density categories to the mammograms. Quantra automatically calculates the volumetric density data into the system. The readers were blinded to the Quantra and other readers assessment. Inter-reader agreement and agreement between Quantra and each reader were tested. Region under the curve (ROC) analysis was performed to obtain the cut-off value to separate dense from a non-dense breast. Results with P value <.05 was taken as significant.There were 40.4% Chinese, 27% Malays, 19% Indian and 3.6% represent other ethnicities. The mean age of the patients was 57. 15%, 45.6%, 30.4%, and 9% of patients fall under BI-RADS A, B, C and D density category respectively. Fair agreement with Kappa (κ) value: 0.49, 0.38, and 0.30 were seen for Reader 1, 2 and 3 versus Quantra. Moderate agreement with κ value: 0.63, 0.64, 0.51 was seen when the data were dichotomized (density A and B to "non-dense", C and D to "dense"). The cut-off Vbd value was 13.5% to stratify dense from non-dense breasts with a sensitivity of 86.2% and specificity of 83.1% (AUC 91.4%; confidence interval: 88.8, 94.1).Quantra showed moderate agreement with radiologists visual assessment. Hence, this study adds to the available evidence to support the potential use of Quantra as an adjunct tool for breast density assessment in routine clinical practice in the Asian population. We found 13.5% is the best cut-off value to stratify dense to non-dense breasts in our study population. Its application will provide an objective, consistent and reproducible results as well as aiding clinical decision-making on the need for supplementary breast ultrasound in our screening population.


Asunto(s)
Densidad de la Mama , Mama/diagnóstico por imagen , Mamografía/métodos , Programas Informáticos , Adulto , Anciano , Anciano de 80 o más Años , Pueblo Asiatico , Femenino , Humanos , Persona de Mediana Edad , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...