Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomolecules ; 13(5)2023 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-37238619

RESUMEN

BACKGROUND: Pregnancy significantly increases the demand for iron (Fe) in the female body to facilitate maternal blood volume expansion, placental development, and fetal growth. As Fe flux in pregnancy is significantly influenced by the placenta, the aim of this study was to determine the dependencies between the Fe concentration in the placenta, the infant's morphometric parameters and the woman's morphological blood parameters in the last trimester. METHODS: The study was conducted on 33 women with multiple (dichorionic-diamniotic) pregnancies from whom the placentas were drawn, and their 66 infants, including pairs of monozygotic (n = 23) and mixed-sex twins (n = 10). Fe concentrations were determined based on inductively coupled plasma atomic emission spectroscopy (ICP-OES) using ICAP 7400 Duo, Thermo Scientific. RESULTS: The results of the analysis showed that lower placental Fe concentrations were associated with deteriorated morphometric parameters of infants, including weight and head circumference. Although we found no statistically significant dependencies between Fe concentration in the placenta and the women's morphological blood parameters, higher Fe concentration in the placenta of mothers supplemented with Fe correlated with better morphometric parameters in infants compared to those whose mothers received no Fe supplementation. CONCLUSIONS: The research adds additional knowledge for placental iron-related processes during multiple pregnancies. However, many limitations of the study do not allow detailed conclusions to be assessed, and statistical data should be assessed conservatively.


Asunto(s)
Placenta , Embarazo Gemelar , Embarazo , Femenino , Humanos , Placenta/irrigación sanguínea , Peso al Nacer , Placentación
2.
Artículo en Inglés | MEDLINE | ID: mdl-37183515

RESUMEN

Chronic kidney disease (CKD) patients have limited mobility. A disease that lasts for many years may harm the musculoskeletal system. Knowledge about changes in body posture in these patients is essential in preventing its degradation. In this work, we wanted to draw attention to the changes in the spatial arrangement of the spine and the entire torso in dialysis patients. The study group consisted of 22 female and 32 male dialysis patients. The posture was examined using the moiré projection technique with a portable Computer-Aided System for Posture Assessment which calculated 82 angular and linear parameters of the spine, scapulae, and pelvis in the frontal and sagittal planes. A significant sexual dimorphism was observed for each spine segment. Asymmetry of the scapulae and pelvis was observed in both sexes. Abnormalities may help to establish an accurate exercise plan for dialysis patients. Proper stimulation of the locomotor system can prevent further degradation of body posture.

3.
Brain Sci ; 13(2)2023 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-36831898

RESUMEN

COVID-19 remains a significant clinical issue worldwide, with frequent neurological manifestations. In this study, the authors combine data obtained from the patient's medical history, physical examinations, and additional test results in the pursuit of any clinically relevant connections. Fifty-eight adult patients hospitalized in the Department of Neurology and Infectiology over a five-months period were retrospectively enrolled in this study. On admission, all patients included in this study were classified as mild or moderate COVID-19 cases, according to the World Health Organization (WHO) guidelines. Laboratory tests, Electroencephalography (EEG), and Magnetic Resonance Imaging (MRI) were performed. There was no statistically significant difference in the Neutrophil-Lymphocyte Ratio (NLR), C-reactive protein (CRP), and Interleukin 6 (IL-6) in patients who reported to the hospital within a week from the symptoms' onset and in those who reported later. In total, 49.06% of patients with eligible EEG recordings presented abnormal brain activity, while 27.59% of the study population had COVID-19-associated MRI findings. EEG and MRI abnormality occurrence did not correlate with the incidence of mild neurological symptoms (headache, olfactory, and gustatory disorders) of the SARS-CoV-2 infection. In three patients in this study population, unprovoked generalized epileptic seizures occurred for the first time in their life. Non-severe SARS-CoV-2 infection causes functional and structural abnormalities within the central nervous system. Brain microhemorrhages are frequently present in non-severe COVID-19 patients. There is no significant association between mild neurological symptoms of COVID-19 and additional test abnormalities. The time from SARS-CoV-2 infection's onset to hospital admission does not seem to influence the prognostic value of CRP, IL-6, and NLR in non-severe COVID-19. Mild-to-moderate SARS-CoV-2 infection can be a trigger factor for epilepsy and epileptic seizures.

4.
Adv Clin Exp Med ; 32(1): 117-123, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36637185

RESUMEN

BACKGROUND: Major depression (MD) is the one of the most debilitating diseases, affecting millions of people all around the world. OBJECTIVES: To establish visual pathway function in untreated individuals with MD. MATERIAL AND METHODS: In 29 untreated, newly diagnosed, ophthalmologically asymptomatic individuals (58 eyes) with MD (mean age: 47.3 years) and in 29 (58 eyes) of age-, sexand refractive error-matched healthy controls (mean age: 46.8 years), the following examinations were performed: 1) best corrected distance visual acuity (BCDVA); 2) intraocular pressure (IOP); 3) and 4) biomicroscopy of anterior and posterior segment of eye; 5) macular structure (SD-OCT-Zeiss); and 6) pattern visual evoked potentials (PVEPs) measurements according to the International Society for Clinical Electrophysiology of Vision (ISCEV) standard (ISCEV-standard PVEPs). An analysis of correlation between the parameters of PVEPs and the depression severity (Hamilton Depression Rating Scale (HAMD)) was performed. To estimate the diagnostic power of PVEPs test, a receiver operating characteristics (ROC) curve was used. Data were analyzed with the significance level of p < 0.05. RESULTS: In the study group and in healthy control, the clinical results and macular structure were normal and not different. In the MD group, in PVEPs test (check size: 1°4'and 0°16'), a significant decrease of amplitudes of P100 (AP100), associated with prolonged P100 peak time (PTP100; check size: 0°16', p < 0.004) were detected. The most frequent abnormality in PVEPs examination in the MD group was AP100 reduction (in 69% of individuals) detected using stimulation check size 0°16'. The statistically significant positive correlation between PTP100 (check size: 0°16') and HAMD score was found in severe MD (p = 0.03). The analysis of ROC curve revealed the highest sensitivity of 0.759 and specificity of 1.0 for AP100 (0°16'). The area under the curve (AUC) was 0.841 (p < 0.001). CONCLUSION: In individuals with newly diagnosed, ophthalmologically asymptomatic and untreated MD, a dysfunction of visual pathway is present without other signs of ocular pathology. The visual pathway dysfunction measured with ISCEV PVEPs has a potential value to be an objective biomarker of MD.


Asunto(s)
Trastorno Depresivo Mayor , Vías Visuales , Humanos , Persona de Mediana Edad , Trastorno Depresivo Mayor/diagnóstico , Potenciales Evocados Visuales , Depresión , Trastornos de la Visión/diagnóstico
5.
Int Ophthalmol ; 40(10): 2553-2562, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32488596

RESUMEN

PURPOSE: To compare visual outcomes after implantation of AtLisa tri 839 MP and Symfony intraocular lenses (IOLs). METHODS: All subjects underwent sequential bilateral cataract extraction with AtLisa tri 839 MP or Symfony IOL implantation. The design is prospective case series. Each group consists of 20 patients (40 eyes). At 1 year postoperatively, the following parameters were analysed: binocular uncorrected visual acuity (log MAR): for distance (UDVA) at 4 m, for intermediate distances (UIVA) at 60, 70, 80 cm and for near (UNVA) at 40 cm, defocus curve, mesopic and photopic contrast sensitivities (CSs), spectacle independence, visual function test questionnaire modified VFQ-25), photopic phenomena and postoperative complications. RESULTS: In the AtLisa tri 839 MP group, the mean binocular UNVA and UIVA were significantly better than in the Symfony group (UNVA: - 0.01 ± 0.04 vs. 0.21 ± 0.15; p = 0.000; 60 cm UIVA: - 0.01 ± 0.04 vs. 0.09 ± 0.09, p = 0.001; 70 cm UIVA - 0.05 ± 0.06 vs. 0.11 ± 0.08, p = 0.002; 80 cm UIVA - 0.01 ± 0.06 vs. 0.15 ± 0.08, p = 0.019). There were no significant between-group differences in the mean binocular UDVA and CS, with one exception: the mean binocular distance CS (18 cpd) under mesopic conditions was significantly better in the Symfony group than in the AtLisa tri 839 MP group (1.39 ± 0.22 vs. 1.17 ± 0.27; p = 0.015). The defocus curve analysis revealed significant between-group differences at vergences of 2.0 to - 4.0 D (p < 0.05), except for 2.0, 1.0, 0 and - 1.5. All subjects in AtLisa tri 839 MP group and 18 subjects (90%) in Symfony group were spectacle independent. Patients from both groups highly rated their overall vision quality in the VFQ-25 (1.67 ± 0.47 vs. 1.85 ± 0.5 in the Symfony and AtLisa tri 839 MP group, respectively, p = NS). The scores for daytime driving (1.00 ± 0.00 vs. 1.21 ± 0.36; p = 0.002), night driving (1.57 ± 0.55 vs. 2.13 ± 1.15; p = 0.027) and difficult situation driving (1.14 ± 0.31 vs. 1.53 ± 0.56; p = 0.049) were significantly better in the AtLisa tri 839 MP group than in the Symfony group. The incidence and perception level of halo and glare were significantly reduced (p = 0.00) in the Symfony group as compared to the AtLisa tri 839 MP group. The postoperative course was uneventful in all subjects. CONCLUSIONS: Visual outcomes achieved with both IOLs are comparable. In both groups, 90% of patients achieved spectacle independence. Whereas the AtLisa tri 839 MP IOL implantation was associated with slightly better intermediate distance VA and significantly better near VA, photic phenomena were less perceived by patients with Symfony IOLs.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Satisfacción del Paciente , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia/cirugía , Refracción Ocular , Visión Binocular
6.
Doc Ophthalmol ; 141(1): 65-76, 2020 08.
Artículo en Inglés | MEDLINE | ID: mdl-32052260

RESUMEN

PURPOSE: To assess the efficacy and safety of the XEN Gel Stent in patients with primary open-angle glaucoma. MATERIALS AND METHODS: Twenty eyes of 17 patients (6 males, 11 females) with primary open-angle glaucoma were implanted with XEN Gel Stent. The following data were ascertained in each participant at baseline and at 1, 3, 6, 9 and 12 months following implanting procedure: intraocular pressure, number of anti-glaucoma medications, retinal sensitivity (PS 24/2 w/w), pattern electroretinogram (ISCEV standard), as well as the number of complications. RESULTS: The mean intraocular pressure reduction in a 1-year follow-up was 18% (21.56 vs. 17.69 mmHg, p < 0.001). The mean number of anti-glaucoma medications was reduced from 3.2 to 1.6 (p = 0.001). The PERG parameters at baseline and at 12 months postoperatively included a stable amplitude of P50 (2.55 µV vs. 2.65 µV, p = 0.024) and N95 (3.45 µV vs. 3.38 µV, p = ns) waves. The delta N95 and delta P50 amplitudes remained stable over the follow-up period (p = ns). The mean deviation (MD) of PS 24/2 was - 6.54 dB vs. - 8.43 dB, p = ns, whereas the pattern standard deviation (PSD) was 6.18 dB vs. 6.91 dB, p = ns. Transient hypotony within the first postoperative week occurred in 18 eyes (90%), whereas hyphema occurred in two eyes (10%). Needle revision of a filtration bleb was performed in five eyes (25%). CONCLUSIONS: The XEN Gel Stent enables significant reduction in intraocular pressure with very low complication rates. It ensures a stabilization of the retinal function as established with the PERG.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma de Ángulo Abierto/cirugía , Retina/fisiopatología , Stents , Anciano , Antihipertensivos/uso terapéutico , Electrorretinografía , Femenino , Glaucoma de Ángulo Abierto/fisiopatología , Humanos , Presión Intraocular/fisiología , Masculino , Persona de Mediana Edad , Implantación de Prótesis , Tonometría Ocular , Resultado del Tratamiento
7.
Int Ophthalmol ; 40(4): 867-875, 2020 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-31956931

RESUMEN

PURPOSE: To compare the 27G versus 25G vitrectomy in patients with epiretinal membrane (ERM). PATIENTS AND METHODS: Sixty pseudophakic eyes of 60 consecutive patients treated by pars plana vitrectomy (PPV) using 27G (30 eyes) or 25G (30 eyes) were prospectively evaluated including eye's inflammation, surgery time, ERM + ILM removal time and complications. Additionally, 1, 3, 7, 14, 30, 90 and 180 days after PPV, the following were estimated: intraocular pressure (IOP), sclerotomy wound closure time, distance best corrected visual acuity (DBCVA), foveal macular thickness (FMT) and surgically induced astigmatism (SIA). RESULTS: The eye's inflammation resolved within 30 days after surgery in both groups. The surgery and ERM + ILM times were longer in the 27G group (p ≤ 0.02). The most common postoperative complication was hypotony in both groups, more common in 25G group (23.3% vs. 10% of eyes). In 27G group, the mean IOP prior to 180 days postoperatively was higher (p < 0.05) and the sclerotomy wound closure time was shorter (p < 0.001). Mean DBCVA values (7, 14, 30 days after surgery) were significantly better in 27G group (p < 0.001). The mean FMT values were similarly and significantly reduced in both groups 1 day postoperatively (p < 0.05) as compared to preoperative values and then stabilized during follow-up. Mean SIA was lower in 27G group 30, 90 and 180 days after surgery (p < 0.001). CONCLUSION: The use of 27G PPV in patients with ERM significantly reduced sclerotomy wound closure time and surgically induced astigmatism, better stabilized intraocular pressure and allowed to achieve faster visual acuity improvement, as compared to 25G PPV.


Asunto(s)
Membrana Epirretinal/cirugía , Presión Intraocular/fisiología , Microcirugia/instrumentación , Agudeza Visual , Vitrectomía/instrumentación , Anciano , Membrana Epirretinal/fisiopatología , Diseño de Equipo , Femenino , Estudios de Seguimiento , Humanos , Masculino , Estudios Prospectivos , Tomografía de Coherencia Óptica , Resultado del Tratamiento
8.
Artículo en Inglés | MEDLINE | ID: mdl-31071998

RESUMEN

The aim of the study was to investigate relationships between the concentrations of macroelements (Ca), microelements (Cr, Cu, Fe, Mn, Mo, Ni, Sn, Sr, V, Zn) and heavy metals (Ag, Cd, Pb) in the placenta, fetal membrane and umbilical cord. ‪Furthermore, we examined relationships between the concentrations of these metals in the studied afterbirths and maternal age, gestational age, placenta parameters (breadth, length, weight) and newborn parameters (length, weight and Apgar score). This study confirms previously reported Zn-Cd, Pb-Cd and Ni-Pb interactions in the placenta. New types of interactions in the placenta, fetal membrane and umbilical cord were also noted. Analysis of the correlations between metal elements in the afterbirths (placenta, fetal membrane and umbilical cord) and biological parameters showed the following relationships: maternal age and Mn (in the fetal membrane); gestational age and Cr, Fe, Zn (in the fetal membrane), Ag and Cu (in the umbilical cord); newborn's length and Sr (in the placenta), Ag (in the umbilical cord); newborn's weight and Sr (in the placenta), Cu (in the fetal membrane), Ag (in the umbilical cord); Apgar score and Ca, Cr and Ni (in the umbilical cord); placenta's length and Cr and Sn (in the fetal membrane), Cu (in the umbilical cord); placenta's width and Mo, Pb (in the placenta) and placenta weight and Sr (in the placenta), Ag, Fe, Mn (in the fetal membrane). The results show the influence of metals on the placenta, mother and newborn parameters, and the same point indicates the essential trace elements during the course of pregnancy.


Asunto(s)
Membranas Extraembrionarias/metabolismo , Metales Pesados/metabolismo , Placenta/metabolismo , Cordón Umbilical/metabolismo , Femenino , Edad Gestacional , Humanos , Recién Nacido , Edad Materna , Embarazo
9.
Adv Clin Exp Med ; 27(1): 15-20, 2018 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29521039

RESUMEN

BACKGROUND: Inflammation associated with biomaterials of Ahmed® glaucoma drainage devices may cause the formation of a capsule around the device and can thus have a significant influence on the level of intraocular pressure reduction. OBJECTIVES: The objective of this study was to compare the clinical outcomes after the implantation of a polypropylene or silicone Ahmed® glaucoma valve in patients with neovascular glaucoma. MATERIAL AND METHODS: In the study, 27 eyes with neovascular glaucoma (group 1) received silicon Ahmed® valves and 23 eyes (group 2) received polypropylene valves. The best corrected distance visual acuity (BCDVA), intraocular pressure (IOP) and number of anti-glaucomatous drugs were recorded preoperatively and during a follow-up period of 24 months after surgery. Success was defined by the following criteria: 1) intraocular pressure in the rage of 6-21 mm Hg; 2) IOP reduction of at least 30% relative to preoperative values. All complications were registered. RESULTS: One month postoperatively, the mean BCDVA increased significantly in both groups compared to preoperative values (p < 0.001). These values did not change during the 24 months of follow-up examinations. The probability of success defined by criterion 1 at 24 months of observation was 66.7% for silicone and 27.3% for propylene valves group (p < 0.007). According to criterion 2, the difference in success between the groups was not statistically significant. The total number of complications that occurred in both groups during the 24 months of follow-up examinations was similar, except for a higher occurrence of Tenon's cyst formation in the group with a polypropylene valve (18% vs 35%; p < 0.04). CONCLUSIONS: In patients with neovascular glaucoma, the implantation of a silicone valve is associated with a significantly higher probability of long-term reduction of IOP below 21 mm Hg and with a lower risk of valve encapsulation in comparison to polypropylene valves. The obtained results suggest that silicone Ahmed® valves are more effective in the treatment of patients with neovascular glaucoma.


Asunto(s)
Implantes de Drenaje de Glaucoma , Glaucoma Neovascular/cirugía , Polipropilenos , Implantación de Prótesis/métodos , Siliconas , Estudios de Seguimiento , Humanos , Presión Intraocular/fisiología , Complicaciones Posoperatorias , Estudios Retrospectivos , Resultado del Tratamiento
10.
Doc Ophthalmol ; 134(2): 89-97, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-28176172

RESUMEN

BACKGROUND: To evaluate retinal ganglion cell (RGC) function after intraocular pressure (IOP) reduction measured by pattern electroretinogram (PERG) in patients with newly diagnosed, non-treated preperimetric and early stages of primary open-angle glaucoma (POAG). METHODS: Twenty-four eyes from 24 patients with POAG: 11 eyes with preperimetric glaucoma and 13 eyes with early glaucoma received Ganfort ® (bimatoprost + timolol) once a day for a period of 1 month. Before and after the treatment, following measurements were analyzed: IOP, mean ocular perfusion pressure (MOPP), peak time of P50 and amplitude of P50 and N95 waves in PERG (ISCEV standard 2012). Correlations between PERG P50 and N95 waves, IOP and MOPP were calculated. RESULTS: After therapy, IOP significantly decreased in all eyes, on average 31%. Significant increase in MOPP in all eyes on average 14% was detected. PERG amplitude of P50 and N95 waves increased in 75 and 79% eyes, respectively, on average P50 by 28% and N95 by 38%. There were no significant interactions between the change of PERG parameters in time and stage of glaucoma. CONCLUSIONS: Significant IOP-lowering therapy can improve RGC function measured by PERG, in patients with preperimetric and early stages of POAG.


Asunto(s)
Antihipertensivos/uso terapéutico , Bimatoprost/uso terapéutico , Glaucoma de Ángulo Abierto/tratamiento farmacológico , Glaucoma de Ángulo Abierto/fisiopatología , Presión Intraocular/fisiología , Células Ganglionares de la Retina/fisiología , Timolol/uso terapéutico , Adulto , Anciano , Análisis de Varianza , Electrorretinografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Visión Ocular , Pruebas del Campo Visual
11.
Doc Ophthalmol ; 133(1): 21-30, 2016 08.
Artículo en Inglés | MEDLINE | ID: mdl-27126340

RESUMEN

PURPOSE: To evaluate macular function and structure before and after epimacular membrane surgery and to estimate the usefulness of pattern ERG test parameters in predicting the postoperative visual acuity. METHODS: We evaluated 32 eyes of 32 patients (mean age 70.8 ± 6.7 years) before and 12 months after successful 25G pars plana vitrectomy with epimacular membrane removal and internal limiting membrane peeling. Distance best-corrected visual acuity (DBCVA-logMAR), foveal thickness (optical coherence tomography-OCT) and macular function [pattern electroretinogram-PERG (ISCEV standard): amplitudes (A) of P50- and N95-waves, implicit time (IT) of P50-wave] were assessed. To estimate the differences between the mean values of considered characteristics, the t test or Wilcoxon matched pair test was used. Correlation between preoperative data of PERG and preoperative and final DBCVA were investigated using Pearson correlation analysis. A receiver operating characteristic curve was constructed to obtain a cutoff value allowing prediction of visual prognosis. We tried to obtain the P50 and N95 amplitudes cutoff value in prediction of good visual outcome (DBCVA of 0.3 or less). RESULTS: Twelve months after surgery, mean of DBCVA significantly increased in comparison with preoperative value (0.31 ± 0.12 vs. 0.6 ± 0.15; p < 0.001) and 23/32 eyes (72 %) achieved visual improvement of two and more Snellen lines. In OCT test, the significant reduction in foveal thickness mean (313.34 ± 47.01 vs. 509.03 ± 93.88 µm; p < 0.001) was obtained. In PERG test, the significant increase in the mean amplitudes of P50- (AP50) and N95 (AN95)-waves as well as significant decrease in the mean implicit time (IT) of P50-wave were achieved (AP50: 3.41 ± 1.48 vs. 2.38 ± 1.23 µV; p < 0.001; AN95: 5.46 ± 1.72 vs. 3.75 ± 1.48 µV; p < 0.001; IT P50: 55.00 ± 3.60 vs. 56.75 ± 5.78 ms; p < 0.001). Twelve months postoperatively, DBCVA was significantly correlated with preoperative IT P50 (r = 0.39; p = 0.027), AP50 (r = -0.68; p < 0.001) and AN95 (r = -0.73; p < 0.001). CONCLUSION: Removal of idiopathic epimacular membranes with internal limiting membrane peeling not only provided increase in visual acuity and reduction in foveal thickness but also caused improvement of innermost retinal layer function in macular region. Pattern ERG test might be a valuable tool in predicting the postoperative visual acuity.


Asunto(s)
Electrorretinografía , Membrana Epirretinal/cirugía , Mácula Lútea/fisiopatología , Agudeza Visual/fisiología , Anciano , Anciano de 80 o más Años , Membrana Basal/cirugía , Electrorretinografía/métodos , Membrana Epirretinal/fisiopatología , Femenino , Fóvea Central/patología , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Pronóstico , Valores de Referencia , Tomografía de Coherencia Óptica , Vitrectomía/métodos
12.
Ann Acad Med Stetin ; 60(1): 47-51, 2014.
Artículo en Polaco | MEDLINE | ID: mdl-25518092

RESUMEN

INTRODUCTION: Studies on many populations have shown that the length of the second finger (2D) compared to the fourth (4D), expressed as the finger length ratio (2D:4D), might be characteristic for sexual dimorphism. It was also found that the values of 2D:4D differ significantly between examined populations. It is thought that the value of 2D:4D is determined in early foetal life under the influence of genetic factors and the strong influence of sex hormones. It has been proven that the values of 2D:4D are related to, for instance, sexual orientation, and artistic and sporting ability. Recently, increasing interest in the clinical signifi- cance of finger length ratio in the diagnosis of somatic and mental disorders has been observed. For example, it was found that values of 2D:4D in individuals suffering from congenital adrenal hyperplasia or autism were significantly lower compared to healthy subjects. The aim of the study was to determine sexual dimor- phism in finger length ratio among representatives of the Polish population. MATERIALS AND METHODS: The study group comprised 115 people (57 females and 58 males). Anthropometric meas- urements were taken from the second and fourth finger of the right and left hands - from the point of dactylion (da) to pseudophalangion (pph) using analogue callipers. We calculated the significance of differences in 2D:4D between males and females separately for the right and left hands. RESULTS: In both hands mean 2D:4D values were lower in males than in females. The difference in the right hand reached the statistical significance level with p < 0.05. CONCLUSIONS: Among the subjects from the examined population the 2D:4D ratio shows trends characteristic for sexual dimorphism.


Asunto(s)
Dedos/anatomía & histología , Caracteres Sexuales , Adulto , Antropometría , Femenino , Dedos/embriología , Humanos , Masculino , Tamaño de los Órganos , Polonia , Valores de Referencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...