Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
2d Mater ; 10(4)2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37521001

RESUMEN

Ti3C2Tx MXene is emerging as the enabling material in a broad range of wearable and implantable medical technologies, thanks to its outstanding electrical, electrochemical, and optoelectronic properties, and its compatibility with high-throughput solution-based processing. While the prevalence of Ti3C2Tx MXene in biomedical research, and in particular bioelectronics, has steadily increased, the long-term stability and degradation of Ti3C2Tx MXene films have not yet been thoroughly investigated, limiting its use for chronic applications. Here, we investigate the stability of Ti3C2Tx films and electrodes under environmental conditions that are relevant to medical and bioelectronic technologies: storage in ambient atmosphere (shelf-life), submersion in saline (akin to the in vivo environment), and storage in a desiccator (low-humidity). Furthermore, to evaluate the effect of the MXene deposition method and thickness on the film stability in the different conditions, we compare thin (25 nm), and thick (1.0 µm) films and electrodes fabricated via spray-coating and blade-coating. Our findings indicate that film processing method and thickness play a significant role in determining the long-term performance of Ti3C2Tx films and electrodes, with highly aligned, thick films from blade coating remarkably retaining their conductivity, electrochemical impedance, and morphological integrity even after 30 days in saline. Our extensive spectroscopic analysis reveals that the degradation of Ti3C2Tx films in high-humidity environments is primarily driven by moisture intercalation, ingress, and film delamination, with evidence of only minimal to moderate oxidation.

2.
ACS Nano ; 17(10): 9442-9454, 2023 05 23.
Artículo en Inglés | MEDLINE | ID: mdl-37171407

RESUMEN

MXenes are being heavily investigated in biomedical research, with applications ranging from regenerative medicine to bioelectronics. To enable the adoption and integration of MXenes into therapeutic platforms and devices, however, their stability under standard sterilization procedures must be established. Here, we present a comprehensive investigation of the electrical, chemical, structural, and mechanical effects of common thermal (autoclave) and chemical (ethylene oxide (EtO) and H2O2 gas plasma) sterilization protocols on both thin-film Ti3C2Tx MXene microelectrodes and mesoscale arrays made from Ti3C2Tx-infused cellulose-elastomer composites. We also evaluate the effectiveness of the sterilization processes in eliminating all pathogens from the Ti3C2Tx films and composites. Post-sterilization analysis revealed that autoclave and EtO did not alter the DC conductivity, electrochemical impedance, surface morphology, or crystallographic structure of Ti3C2Tx and were both effective at eliminating E. coli from both types of Ti3C2Tx-based devices. On the other end, exposure to H2O2 gas plasma sterilization for 45 min induced severe degradation of the structure and properties of Ti3C2Tx films and composites. The stability of the Ti3C2Tx after EtO and autoclave sterilization and the complete removal of pathogens establish the viability of both sterilization processes for Ti3C2Tx-based technologies.


Asunto(s)
Escherichia coli , Peróxido de Hidrógeno , Titanio/farmacología , Esterilización
3.
Small ; 19(6): e2205854, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36433864

RESUMEN

Cell engineering, soft robotics, and wearable electronics often desire soft materials that are easy to deform, self-heal readily, and can relax stress rapidly. Hydrogels, a type of hydrophilic networks, are such kind of materials that can be made responsive to environmental stimuli. However, conventional hydrogels often suffer from poor stretchability and repairability. Here, hydrogels consisting of boronic ester dynamic covalent bonds in a double network of poly(vinyl alcohol)/boric acid and chitosan are synthesized, which demonstrate extreme stretchability (up to 310 times the original length), instant self-healing (within 5 s), and reusability and inherent adhesion. Their instant stress relaxation stems from a low activation energy of the boronic ester bond exchange (≤20 kJ mol-1 ) and contributes to the extreme stretchability and self-healing behaviors. Various water-dispersible additives can be readily incorporated in the hydrogels via hand kneading for potential applications such as soft electronics, bio-signal sensing, and soft artificial joints.

4.
iScience ; 25(7): 104652, 2022 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-35811842

RESUMEN

Nanocarbons are often employed as coatings for neural electrodes to enhance surface area. However, processing and integrating them into microfabrication flows requires complex and harmful chemical and heating conditions. This article presents a safe, scalable, cost-effective method to produce reduced graphene oxide (rGO) coatings using vitamin C (VC) as the reducing agent. We spray coat GO + VC mixtures onto target substrates, and then heat samples for 15 min at 150°C. The resulting rGO films have conductivities of ∼44 S cm-1, and are easily integrated into an ad hoc microfabrication flow. The rGO/Au microelectrodes show ∼8x lower impedance and ∼400x higher capacitance than bare Au, resulting in significantly enhanced charge storage and injection capacity. We subsequently use rGO/Au arrays to detect dopamine in vitro, and to map cortical activity intraoperatively over rat whisker barrel cortex, demonstrating that conductive VC-rGO coatings improve the performance and stability of multimodal microelectrodes for different applications.

5.
eNeuro ; 9(3)2022.
Artículo en Inglés | MEDLINE | ID: mdl-35470227

RESUMEN

Hippocampal seizures are a defining feature of mesial temporal lobe epilepsy (MTLE). Area CA1 of the hippocampus is commonly implicated in the generation of seizures, which may occur because of the activity of endogenous cell populations or of inputs from other regions within the hippocampal formation. Simultaneously observing activity at the cellular and network scales in vivo remains challenging. Here, we present a novel technology for simultaneous electrophysiology and multicellular calcium imaging of CA1 pyramidal cells (PCs) in mice enabled by a transparent graphene-based microelectrode array (Gr MEA). We examine PC firing at seizure onset, oscillatory coupling, and the dynamics of the seizure traveling wave as seizures evolve. Finally, we couple features derived from both modalities to predict the speed of the traveling wave using bootstrap aggregated regression trees. Analysis of the most important features in the regression trees suggests a transition among states in the evolution of hippocampal seizures.


Asunto(s)
Epilepsia del Lóbulo Temporal , Grafito , Animales , Hipocampo , Ratones , Microelectrodos , Convulsiones
6.
Sci Transl Med ; 13(612): eabf8629, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-34550728

RESUMEN

Soft bioelectronic interfaces for mapping and modulating excitable networks at high resolution and at large scale can enable paradigm-shifting diagnostics, monitoring, and treatment strategies. Yet, current technologies largely rely on materials and fabrication schemes that are expensive, do not scale, and critically limit the maximum attainable resolution and coverage. Solution processing is a cost-effective manufacturing alternative, but biocompatible conductive inks matching the performance of conventional metals are lacking. Here, we introduce MXtrodes, a class of soft, high-resolution, large-scale bioelectronic interfaces enabled by Ti3C2 MXene (a two-dimensional transition metal carbide nanomaterial) and scalable solution processing. We show that the electrochemical properties of MXtrodes exceed those of conventional materials and do not require conductive gels when used in epidermal electronics. Furthermore, we validate MXtrodes in applications ranging from mapping large-scale neuromuscular networks in humans to cortical neural recording and microstimulation in swine and rodent models. Last, we demonstrate that MXtrodes are compatible with standard clinical neuroimaging modalities.


Asunto(s)
Fenómenos Electrofisiológicos , Electrofisiología
7.
Sensors (Basel) ; 21(15)2021 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-34372446

RESUMEN

A low and stable impedance at the skin-electrode interface is key to high-fidelity acquisition of biosignals, both acutely and in the long term. However, recording quality is highly variable due to the complex nature of human skin. Here, we present an experimental and modeling framework to investigate the interfacial impedance behavior, and describe how skin interventions affect its stability over time. To illustrate this approach, we report experimental measurements on the skin-electrode impedance using pre-gelled, clinical-grade electrodes in healthy human subjects recorded over 24 h following four skin treatments: (i) mechanical abrasion, (ii) chemical exfoliation, (iii) microporation, and (iv) no treatment. In the immediate post-treatment period, mechanical abrasion yields the lowest initial impedance, whereas the other treatments provide modest improvement compared to untreated skin. After 24 h, however, the impedance becomes more uniform across all groups (<20 kΩ at 10 Hz). The impedance data are fitted with an equivalent circuit model of the complete skin-electrode interface, clearly identifying skin-level versus electrode-level contributions to the overall impedance. Using this model, we systematically investigate how time and treatment affect the impedance response, and show that removal of the superficial epidermal layers is essential to achieving a low, long-term stable interface impedance.


Asunto(s)
Piel , Impedancia Eléctrica , Electrodos , Humanos
8.
Commun Biol ; 4(1): 136, 2021 01 29.
Artículo en Inglés | MEDLINE | ID: mdl-33514839

RESUMEN

Neurological disorders such as epilepsy arise from disrupted brain networks. Our capacity to treat these disorders is limited by our inability to map these networks at sufficient temporal and spatial scales to target interventions. Current best techniques either sample broad areas at low temporal resolution (e.g. calcium imaging) or record from discrete regions at high temporal resolution (e.g. electrophysiology). This limitation hampers our ability to understand and intervene in aberrations of network dynamics. Here we present a technique to map the onset and spatiotemporal spread of acute epileptic seizures in vivo by simultaneously recording high bandwidth microelectrocorticography and calcium fluorescence using transparent graphene microelectrode arrays. We integrate dynamic data features from both modalities using non-negative matrix factorization to identify sequential spatiotemporal patterns of seizure onset and evolution, revealing how the temporal progression of ictal electrophysiology is linked to the spatial evolution of the recruited seizure core. This integrated analysis of multimodal data reveals otherwise hidden state transitions in the spatial and temporal progression of acute seizures. The techniques demonstrated here may enable future targeted therapeutic interventions and novel spatially embedded models of local circuit dynamics during seizure onset and evolution.


Asunto(s)
Ondas Encefálicas , Señalización del Calcio , Corteza Cerebral/fisiopatología , Electrocorticografía/instrumentación , Grafito , Microelectrodos , Imagen Óptica/instrumentación , Convulsiones/diagnóstico , Animales , Corteza Cerebral/metabolismo , Modelos Animales de Enfermedad , Diseño de Equipo , Ratones Transgénicos , Miniaturización , Valor Predictivo de las Pruebas , Convulsiones/genética , Convulsiones/metabolismo , Convulsiones/fisiopatología , Procesamiento de Señales Asistido por Computador , Factores de Tiempo
9.
Adv Mater Technol ; 5(8)2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33693054

RESUMEN

Wearable sensors for surface electromyography (EMG) are composed of single- to few-channel large-area contacts, which exhibit high interfacial impedance and require conductive gels or adhesives to record high-fidelity signals. These devices are also limited in their ability to record activation across large muscle groups due to poor spatial coverage. To address these challenges, we have developed a novel high-density EMG array based on titanium carbide (Ti3C2Tx) MXene encapsulated in parylene-C. Ti3C2Tx is a two-dimensional nanomaterial with excellent electrical, electrochemical, and mechanical properties, which forms colloidally stable aqueous dispersions, enabling safe, scalable solutions-processing. Leveraging the excellent combination of metallic conductivity, high pseudocapacitance, and ease of processability of Ti3C2Tx MXene, we demonstrate the fabrication of gel-free, high-density EMG arrays which are ~8 µm thick, feature 16 recording channels, and are highly skin-conformable. The impedance of Ti3C2Tx electrodes in contact with human skin is 100-1000x lower than the impedance of commercially-available electrodes which require conductive gels to be effective. Furthermore, our arrays can record high-fidelity, low-noise EMG, and can resolve muscle activation with improved spatiotemporal resolution and sensitivity compared to conventional gelled electrodes. Overall, our results establish Ti3C2Tx-based bioelectronic interfaces as a powerful platform technology for high-resolution, non-invasive wearable sensing technologies.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...