Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 24
Filtrar
1.
J Cataract Refract Surg ; 49(11): 1183-1186, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37867287

RESUMEN

A 33-year-old woman with a prior history of small-incision lenticule extraction (SMILE) presented with gradual deterioration of vision in her right eye since the surgery. She had undergone bilateral SMILE for myopic correction (-7.00 diopters [D] in the right eye and -6.00 D in the left eye) 3 weeks prior. SMILE was performed with a Zeiss VisuMax femtosecond laser system, with a cap thickness of 120 µm, a cap diameter of 7.50 mm, and a lenticule diameter of 6.50 mm. At the completion of the surgery, loose epithelium was noted at the SMILE incision bilaterally, and bandage contact lenses were placed in both eyes. On the first postoperative day, the patient's uncorrected distance visual acuity (UDVA) was 20/40 in both eyes. The bandage lenses were removed from both eyes, with the epithelium intact. At the first-week postoperative visit, her visual acuity was recorded as 20/30 in the right eye and 20/20 in the left eye. She noticed her vision in the right eye was not as sharp as that in her left eye. She denied experiencing any pain, redness, or ocular surface irritations. She was advised to return to the clinic for a 1-month postoperative visit and continue with aggressive lubrication in both eyes. However, a week later, the patient returned for an emergency visit, citing significant central visual distortion in the right eye and difficulty working on the computer. At this visit, her UDVA and corrected distance visual acuity (CDVA) was 20/50 in the right eye and 20/15 in the left eye at both near and far distances. A slitlamp examination revealed mild central changes in the right eye. She once again denied any pain, redness, or irritation. She was advised to continue with artificial tears and return to the office in 1 week for further observation of the central distortion in her right eye. Upon returning to the clinic at the third postoperative week, the patient still complained of central visual changes in the right eye, with a visual acuity of 20/70. Further slitlamp examination revealed a nonspecific central haze in the same eye, but there was no corneal staining or signs of epithelial defects. Anterior segment ocular coherence tomography (AS-OCT) and NIDEK topography were performed, showing the same central distortion in the right eye (Figures 1 and 2JOURNAL/jcrs/04.03/02158034-202311000-00016/figure1/v/2023-10-18T004638Z/r/image-tiffJOURNAL/jcrs/04.03/02158034-202311000-00016/figure2/v/2023-10-18T004638Z/r/image-tiff). Based on the examination and images provided, what is your working medical diagnosis? What other medical conditions are in your differential diagnosis? What medical and/or surgical interventions would you recommend, if any?


Asunto(s)
Cirugía Laser de Córnea , Refracción Ocular , Humanos , Femenino , Adulto , Sustancia Propia/cirugía , Topografía de la Córnea , Láseres de Excímeros , Tomografía de Coherencia Óptica , Cirugía Laser de Córnea/efectos adversos , Cirugía Laser de Córnea/métodos , Dolor
2.
Clin Ophthalmol ; 17: 555-560, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36798796

RESUMEN

Purpose: To understand the role of ophthalmic viscosurgical devices (OVDs) in corneal incision contracture (CIC). Specifically, the aim was to evaluate with the tip of the phacoemulsification needle free of OVD, how various OVDs near the tip and sleeve may transmit thermal energy to the incision site. Methods: A small chamber was filled with balanced saline solution (BSS), and a thin membrane was placed on the surface. OVD was placed atop the membrane. A temperature probe was placed in the OVD, while the handpiece pierced the membrane. The experiment was run both with and without flow and vacuum. Temperature measurements were gathered for each of the OVDs at four separate time points at 0 and 20mL/min flow. Results: As expected, there was a more pronounced temperature increase in all test groups with no fluid flow. While the temperature increase was not significantly different from BSS for any of the OVDs tested at either 0 or 20mL/min, Viscoat showed the most variable results at both flow settings. Conclusion: As long as the phaco tip is not in OVD, residual OVD near the incision is not exothermic and so not an additional risk for CIC.

3.
Can J Ophthalmol ; 58(6): 507-512, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-35868436

RESUMEN

OBJECTIVE: To study the thermal properties and response magnitude of a forced-infusion phacoemulsification machine on 4 ophthalmic viscosurgical devices (OVDs). DESIGN: Experimental study. METHODS: A phacoemulsification tip, thermocouple, and gauge were placed into an artificial anterior chamber with balanced saline solution (BSS) or approximately 0.1 mL of OVD. Once the thermocouple measured a consistent temperature, the pedal was engaged for 60 seconds; then the tip was removed. The machine was cooled for 5 minutes and flushed with BSS to return to baseline. This was repeated 10 times for each OVD. The research consisted of 2 scenarios: vacuum-blocked flow rate and low aspiration flow rate. RESULTS: All OVDs showed greater temperature changes than BSS. In the vacuum-blocked scenario, these increases were statistically significant. The medium viscosity dispersive OVD (DiscoVisc) reached temperatures exceeding 60°C. In the low-flow scenario, HEALON5 and DisCoVisc were significantly different at 5 seconds and only HEALON5 at 10 seconds. No temperature increases over BSS were greater than 1.0°C. CONCLUSIONS: The dispersive, cohesive, and viscoadaptive OVDs demonstrated higher temperature changes than BSS but did not reach the threshold for corneal incision contracture. The study team verified the need for at least a minimal flow rate before ultrasound, which is especially evident in the first 10 seconds, because a flow rate of only 20 mL/minute mitigated OVD-related thermal effects. Understanding thermal responses enables corneal incision contracture risk reduction.


Asunto(s)
Contractura , Facoemulsificación , Humanos , Combinación de Medicamentos , Sulfatos de Condroitina , Ácido Hialurónico
4.
Vision (Basel) ; 6(3)2022 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-35893760

RESUMEN

The Navajo Nation is the largest Native American reservation by area and citizenship. The study sought to provide the first large-scale examination of ocular pathology within this population. A retrospective review of all Navajo patients seen at Moran Eye Center Navajo Nation Outreach Clinics from 2013 to 2021 for demographics, visual acuity, refractive, and eye pressure data was undergone. Further variables included comorbidity and eye diagnoses among patients at these clinics. Results: First-time patient visits totaled 2251 from 2013 to 2021. The median age was 53 (range, 18 to 92), and clinics had a predominance of female patients (1387:864). Among patients presenting without glasses, 20.67% (198/958), 9.71% (93/958), and 3.13% (30/958) had mild visual impairment (VI), moderate to severe VI, and blindness, respectively. Cataracts were the most common cause of blindness in these patients (40%, 12/30) and the need for glasses was the second most common cause (33%, 10/30). From 2016 to 2021, 17.71% (48/271) of diabetic patients were diagnosed with diabetic retinopathy (DR). Within the subset of Navajo patients that presented without any correction, 73% of bilateral blindness was preventable via glasses prescription or cataract surgery. This study comments on questions of equitable care for Navajo patients.

5.
J Cataract Refract Surg ; 48(4): 508-512, 2022 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-35318296

RESUMEN

A 40-year-old woman was referred for the assessment of bilateral corneal opacities with gradual visual decline over the course of the past decade. Her past ocular history is significant for bilateral amblyopia and strabismus surgery in both eyes before age 5. The patient's parents were told by her childhood ophthalmologist that she had a hereditary disorder. Her systemic review was significant for anal fissure and human leukocyte antigen-B27 ankylosing spondylitis. Her past ocular record revealed corrected distance visual acuity (CDVA) of 20/80 in both eyes in 2018 with central corneal haze. On presentation, her uncorrected distance visual acuity was 20/150 in both eyes. Her CDVA was 20/100 in both eyes with manifest refraction of +0.50 -2.50 × 075 in the right eye and +5.00 -2.25 × 094 in the left eye. Corneal topography reflected keratometry of 35.75/38.97 × 171 in the right eye and 36.45/38.35 × 32 in the left eye. Central corneal thickness was 669 µm and 652 µm, respectively. External slitlamp examination revealed a central faint stromal opacity inferior to the visual axis in the right eye and a central faint stromal opacity in the left eye, and both were associated with steep posterior curvature of the cornea (Figure 1). Further findings included 0.5 corneal haze with mild guttata, normal irides, and clear lenses in both eyes. Intraocular pressure was 23 mm Hg and 26 mm Hg, respectively (Figure 2, Supplemental Figures 1 and 2, http://links.lww.com/JRS/A543). Gonioscopy was unremarkable. Dilated fundus examination revealed a 0.15 cup-to-disc ratio bilaterally, but otherwise no pertinent vitreoretinal pathologies were noted. What is the most likely diagnosis? What medical or surgical interventions would you recommend for this patient? What is the prognosis for this patient?


Asunto(s)
Córnea , Opacidad de la Córnea , Adulto , Niño , Preescolar , Topografía de la Córnea , Femenino , Humanos , Presión Intraocular , Iris , Refracción Ocular , Agudeza Visual
6.
Eye Contact Lens ; 47(8): 442-444, 2021 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-33900215

RESUMEN

OBJECTIVES: Decreased blink rate during video display viewing (VDV) has been reported; however, patients with tear dysfunction often complain of more frequent blinking. The objectives were to compare blink rates during conversation and VDV in normal and dry eyes and correlate blink rates with signs and symptoms. METHODS: Blink rate was measured with an infrared blink sensor for 2 minutes during conversation and for 2 minutes while watching a video clip (VDV) in patients without dry eye disease (control, n=18) and in patients with tear dysfunction from meibomian gland dysfunction (MGD, n=23), conjunctivochalasis (CCh, n=19), and aqueous tear deficiency (n=34; non-Sjögren syndrome n=18 and Sjögren syndrome n=16). Patients completed visual analogue questionnaires assessing irritation frequency and severity and blink frequency and underwent an ocular surface evaluation. Group comparisons and correlations were calculated. RESULTS: Compared with control, conversational and VDV blink rates were significantly higher in CCh and aqueous tear deficiency (P≤0.005). Self-reported blink frequency was higher in all tear dysfunction groups compared with control. The VDV blink rate was significantly lower than the conversation blink rate in the control group (P=0.006) but not in any of the tear dysfunction groups. Conversational and VDV blink rates were significantly correlated with irritation frequency and severity. CONCLUSIONS: Blink rate decreases during VDV in normal eyes; however, this blink rate suppression was not observed in patients with tear dysfunction, perhaps because of their irritation symptoms or tear instability.


Asunto(s)
Síndromes de Ojo Seco , Queratoconjuntivitis Seca , Disfunción de la Glándula de Meibomio , Parpadeo , Síndromes de Ojo Seco/diagnóstico , Humanos , Glándulas Tarsales , Lágrimas
7.
Artículo en Inglés | MEDLINE | ID: mdl-31598520

RESUMEN

Corneal tomography and Scheimpflug imaging are frequently used to analyze the corneal surface, especially in the field of cataract and refractive surgery. The Pentacam system is one of the most commonly used commercially available systems for this purpose. Through a rotating Scheimpflug camera, the system is capable of creating a three-dimensional map of the cornea. These advances in tomography have simultaneously enhanced the ability of clinicians to screen surgical candidates and detect subtle corneal changes in diseases such as keratoconus. However, there remains a need to enhance diagnosis in order to recognize mild and early forms of corneal ectasia. As iatrogenic ectasia and keratoconus are dreaded complications of refractive surgery, it is imperative to screen patients appropriately prior to surgery. The Pentacam is one of many systems utilized in the screening process, but the literature has not identified specific protocol nor parameters that are capable of carrying out this process appropriately. Post-operative keratoconus continues to occur despite the advances in technology seen in corneal imaging. Therefore, clear indices for screening are required in order to diagnose early forms of keratoconus and other corneal diseases that may exclude the seemingly asymptomatic patient from undergoing refractive surgery. This article aims to summarize the indices available on the Pentacam system and to identify the most accurate parameters for screening of the refractive surgery candidate.

8.
Artículo en Inglés | MEDLINE | ID: mdl-31598521

RESUMEN

Corneal topography is the most widely used technology for examining the anterior corneal surface. Scheimpflug imaging is a newer technique that allows for measurement of both the anterior and posterior corneal surface, which allows for three-dimensional reconstruction of the cornea. This is of particular interest and value in the field of cataract and refractive surgery. The Galilei camera is a commercially available dual Scheimpflug system that combines curvature data from Placido disc-based corneal topography with elevation data from Scheimpflug technology. The addition of Placido disc topography makes the Galilei unique from its more popular counterpart, the Pentacam, which was discussed in Part I. Compared to the Pentacam, and however, the Galilei analyzer is a newer system that has emerged as a valuable screening tool given its dual Scheimpflug capability. In the first article of this series, the authors summarized the refractive indices available on the Pentacam system with the purpose of identifying the best diagnostic parameters for keratoconus. Similarly, the purpose of this article is to summarize corneal surface indices available on the Galilei system and evaluate their use in screening of the refractive surgery candidate. Since post-operative keratectasia is still prevalent, this paper aims to identify the most clinically relevant indices that may be used in pre-operative evaluation.

9.
Artículo en Inglés | MEDLINE | ID: mdl-31598522

RESUMEN

Corneal biomechanical properties have garnered significant interest in their relation to the development of ectatic corneal disease. Alongside the advent of corneal tomography and Scheimpflug imaging such as Pentacam and Galilei, there have been advances in assessing the cornea based on its biomechanical characteristics. Though the aforementioned imaging systems are highly capable of identifying morphologic abnormalities, they cannot assess mechanical stability of the cornea. This article, in contrast to Parts I and II of this article series, will focus on in vivo corneal biomechanical imaging systems. The two most readily available commercial systems include the Corvis ST and the Ocular Response Analyzer. Both of these systems aimed to characterize corneal biomechanics via distinct measurements. While in Parts I and II of this article series the authors focused on elevation, pachymetric, and keratometric data, the purpose of this article was to summarize biomechanical parameters and their clinical use in screening refractive surgery candidates. Moreover, this article explores biomechanical decompensation and its role in the development of corneal ectasia and keratoconus. There is a focus on the diagnostic accuracy of biomechanical indices in the identification of diseases such as keratoconus that may preclude a patient from undergoing refractive surgery.

11.
Ophthalmol Ther ; 8(2): 195-213, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30859513

RESUMEN

The corneal endothelium plays an integral role in regulating corneal hydration and clarity. Endotheliitis, defined as inflammation of the corneal endothelium, may disrupt endothelial function and cause subsequent visual changes. Corneal endotheliitis is characterized by corneal edema, the presence of keratic precipitates, anterior chamber inflammation, and occasionally limbal injection, neovascularization, and co-existing or superimposed uveitis. The disorder is classified into four subgroups: linear, sectoral, disciform, and diffuse. Its etiology is extensive and, although commonly viral, may be medication-related, procedural, fungal, zoological, environmental, or systemic. Not all cases of endothelial dysfunction leading to corneal edema are inflammatory in nature. Therefore, it is imperative that practitioners consider a broad differential for patients presenting with possible endotheliitis, as well as familiarize themselves with appropriate diagnostic and therapeutic modalities.

12.
Surv Ophthalmol ; 64(2): 162-174, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30316804

RESUMEN

Terrien marginal degeneration, a rare disease resulting in peripheral corneal thinning, commonly occurs in middle-aged males and usually manifests clinically with decreased visual acuity from increased corneal astigmatism. Although the exact etiology is unknown, hypotheses focus on possible degenerative and inflammatory origins. Histopathologic studies often reveal characteristic findings of innumerable intracellular and extracellular vacuoles in the affected stroma. Distinguishing Terrien marginal degeneration from other peripheral corneal diseases such as Mooren ulcer and pellucid marginal degeneration is important. Nonsurgical interventions include spectacles, rigid gas-permeable contact lenses, and scleral lenses; however, when the corneal thickness is ≤150 µm, surgical interventions including tectonic grafting and lamellar keratoplasty may be necessary.


Asunto(s)
Distrofias Hereditarias de la Córnea/diagnóstico , Enfermedades Raras , Lentes de Contacto , Distrofias Hereditarias de la Córnea/terapia , Trasplante de Córnea , Humanos , Microscopía Confocal , Tomografía de Coherencia Óptica
13.
Clin Ophthalmol ; 12: 1931-1938, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30323549

RESUMEN

PURPOSE: To assess longitudinal refractive, keratometric, and topographic changes following KAMRA small-aperture inlay implantation. DESIGN AND SETTING: Prospective study at a single site refractive surgery center. METHODS: Fifty patients underwent KAMRA small-aperture corneal inlay implantation for the correction of presbyopia. Uncorrected near visual acuity (UNVA), uncorrected distance visual acuity, manifest refractive spherical equivalent (MRSE), mean keratometry (Km), corneal topography, and surgically induced astigmatism vector analysis assessments were performed preoperatively and at 1, 3, 6, 12, 24, and 36 months postoperatively. RESULTS: The study comprises 50 eyes. An average shift of 0.15±0.63 D (range -1.63 to 2.00 D) occurred between preoperative baseline and 36 months. At 36 months, 54% of patients had hyperopic MRSE and 40% had myopic MRSE compared with baseline. Km was significantly elevated at all postoperative measurements compared with baseline, with the largest Km measured at 12 months. Eighty-six percent of patients had UNVA of 20/32 or better and 88% uncorrected distance visual acuity of 20/25 or better at 36 months. Longitudinal corneal topography revealed a pattern of corneal steepening over the body of the inlay and flattening over the aperture, correlating with a hyperopic shift. There was no significant surgically induced astigmatism. CONCLUSION: KAMRA inlay may cause an increase in Km compared with baseline. Corneal steepening may occur in a specific pattern with steepening over the inlay and flattening over the aperture. This topographic pattern causes a hyperopic shift, which may be relevant for subsequent procedures, such as cataract extraction.

14.
Ophthalmol Ther ; 7(2): 347-360, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-29959753

RESUMEN

INTRODUCTION: The primary objective was to show our initial surgical single-site experience with small incision lenticule extraction (SMILE) after the official enrollment in March 2017 following Food and Drug Administration (FDA) approval for simple myopia in late 2016 in the United States and, subsequently, compare our results to the earliest and most advanced generation of excimer platforms for laser-assisted in situ keratomileusis (LASIK) surgery. METHODS: This was a retrospective single-site study of 68 eyes from 35 patients who had SMILE surgery. The patients' preoperative and postoperative uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), manifest sphere, manifest cylinder, intraoperative complications, and preoperative and postoperative visual symptoms were collected. We compared our findings to the results from the FDA SMILE study, and to the three earliest (1999-2000) and three of the most updated (2013-2016) platforms for LASIK. RESULTS: The cumulative UDVA was 20/20 and 20/40 or better in 74% and 100% of patients, respectively. The intended target refraction was within ± 0.5 and ± 1.00 D in 80% and 93% of cases, respectively. The prevalence of dry eyes decreased by nearly half from 1-week to the 6-month postoperative interval. Patients noted improvement in glare (17%), halos (17%), fluctuation (25%), and depth perception (8%) at the 6-month interval compared to preoperative levels. CONCLUSIONS: This study's findings are consistent with current SMILE reports. Notably, the results are superior to the earliest generation of LASIK, however inferior to the latest excimer platforms. SMILE does meet the efficacy and safety criteria met by FDA; however, there is a definite need for further improvement to reach the superior refractive outcomes produced by the latest generation of LASIK platforms.

15.
Clin Ophthalmol ; 12: 1105-1112, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29950805

RESUMEN

The amniotic membrane (AM) has a long history of use in the treatment of various diseases of the ocular surface. It contains pluripotent cells, highly organized collagen, anti-fibrotic and anti-inflammatory cytokines, immune-modulators, growth factors, and matrix proteins. It is used to promote corneal healing in severely damaged eyes. Recently, AM extract and AM extract eye drops have been successfully used in clinical applications, including dry eye and chemical burns. We provide an overview on the recent progress in the preparation, mechanisms of action, and use of AM extract/AM extract eye drops for corneal and external eye diseases.

16.
J Cataract Refract Surg ; 44(7): 856-863, 2018 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-29909960

RESUMEN

PURPOSE: To determine the risk factors, intraoperative and postoperative complications, therapeutic interventions, and visual outcomes for persistent postoperative inflammation in primary resident-performed cataract surgeries. SETTING: Ben Taub General Hospital, Houston, Texas, USA. DESIGN: Retrospective case series. METHODS: Primary resident-performed cataract surgeries from January 2012 to June 2015 were analyzed for persistent postoperative inflammation, defined as persistent anterior chamber inflammatory reaction after a standard 1-month topical corticosteroid and nonsteroidal antiinflammatory drug (NSAID) drops taper. Preoperative characteristics, operative complications, therapeutic modalities, and duration of therapy were analyzed. The primary outcome measures were duration of corticosteroid and NSAID therapy, treatment modalities, and postoperative visual outcomes at the 1-month postoperative visit. RESULTS: The study assessed 1290 primary resident-performed cataract surgeries. Persistent postoperative inflammation occurred in 82 eyes (6.6%). The presumed etiology was classified as idiopathic persistent postoperative inflammation, nonadherence to topical therapy, and complicated cataract surgery. Patients with persistent postoperative inflammation were more likely of African American descent, had hypertension, or used aspirin, anticoagulants, or prostaglandins (P = .019, P = .027, P = .028, P = .020, respectively). The complicated cataract subgroup required a longer duration of therapy (P = .021) and was the only subgroup to require injections or systemic corticosteroids. There was no significant difference in postoperative corrected distance visual acuity (CDVA) when comparing patients with persistent postoperative inflammation with those without inflammation or between the subgroups. CONCLUSIONS: The idiopathic and nonadherent subgroups were successfully treated with topical antiinflammatory therapy; the complicated subgroup required longer duration and multiple modalities of treatment. Visual outcomes were comparable to the general cataract population with no differences in postoperative CDVA.


Asunto(s)
Extracción de Catarata/educación , Inflamación/etiología , Internado y Residencia , Oftalmología/educación , Complicaciones Posoperatorias , Adulto , Cámara Anterior/patología , Antiinflamatorios no Esteroideos/uso terapéutico , Femenino , Glucocorticoides/uso terapéutico , Hospitales Públicos , Humanos , Inflamación/tratamiento farmacológico , Inflamación/fisiopatología , Complicaciones Intraoperatorias , Implantación de Lentes Intraoculares , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Refracción Ocular/fisiología , Estudios Retrospectivos , Factores de Riesgo , Atención Terciaria de Salud , Resultado del Tratamiento , Agudeza Visual/fisiología
18.
Artículo en Inglés | MEDLINE | ID: mdl-29644238

RESUMEN

Laser vision correction is a safe and effective method of reducing spectacle dependence. Photorefractive Keratectomy (PRK), Laser In Situ Keratomileusis (LASIK), and Small-Incision Lenticule Extraction (SMILE) can accurately correct myopia, hyperopia, and astigmatism. Although these procedures are nearing optimization in terms of their ability to produce a desired refractive target, the long term cellular responses of the cornea to these procedures can cause patients to regress from the their ideal postoperative refraction. In many cases, refractive regression requires follow up enhancement surgeries, presenting additional risks to patients. Although some risk factors underlying refractive regression have been identified, the exact mechanisms have not been elucidated. It is clear that cellular proliferation events are important mediators of optical regression. This review focused specifically on cellular changes to the corneal epithelium and stroma, which may influence postoperative visual regression following LASIK, PRK, and SMILE procedures.

19.
Ophthalmol Ther ; 7(1): 197-202, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29536349

RESUMEN

Ultramarathon-associated corneal edema is a rare phenomenon. We report a case of a patient who presented with bilateral corneal edema following an ultramarathon. The corneal edema resolved without sequelae 48 h later. The authors hypothesize that the additive effect of enhanced glycolysis, an increased lactate level in the aqueous humor, and oxidative stress alters the normal endothelial regulation of the cornea and leads to corneal edema.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...