Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Front Med (Lausanne) ; 9: 774550, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35386920

RESUMEN

Background: Rapid diagnostic testing for SARS-Cov-2 antigens is used to combat the ongoing pandemic. In this study we aimed to compare two RDTs, the SD Biosensor Q SARS-CoV-2 Rapid Antigen Test (Roche) and the Panbio COVID-19 Ag Rapid Test (Abbott), against rRT-PCR. Methods: We included 2,215 all-comers at a diagnostic center between February 1 and March 31, 2021. rRT-PCR-positive samples were examined for SARS-CoV-2 variants. Findings: Three hundred and thirty eight participants (15%) were rRT-PCR-positive for SARS-CoV-2. The sensitivities of Roche-RDT and Abbott-RDT were 60.4 and 56.8% (P < 0.0001) and specificities 99.7% and 99.8% (P = 0.076). Sensitivity inversely correlated with rRT-PCR-Ct values. The RDTs had higher sensitivities in individuals referred by treating physicians (79.5%, 78.7%) than in those referred by health departments (49.5%, 44.3%) or tested for other reasons (50%, 45.8%), in persons without any comorbidities (74.4%, 71%) compared to those with comorbidities (38.2%, 34.4%), in individuals with COVID-19 symptoms (75.2%, 74.3%) compared to those without (31.9%, 23.3%), and in the absence of SARS-CoV-2 variants (87.7%, 84%) compared to Alpha variant carriers (77.1%, 72.3%). If 10,000 symptomatic individuals are tested of which 500 are truly positive, the RDTs would generate 38 false-positive and 124 false-negative results. If 10,000 asymptomatic individuals are tested, including 50 true positives, 18 false-positives and 34 false-negatives would be generated. Interpretation: The sensitivities of the two RDTs for asymptomatic SARS-CoV-2 carriers are unsatisfactory. Their widespread use may not be effective in the ongoing SARS-CoV-2 pandemic. The virus genotype influences the sensitivity of the two RDTs. RDTs should be evaluated for different SARS-CoV-2 variants.

2.
Diagn Microbiol Infect Dis ; 102(2): 115587, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34826767

RESUMEN

Reliable diagnostic technologies are pivotal to the fight against COVID-19. While real-time reverse transcription-polymerase chain reaction (rRT-PCR) remains the gold standard, commercial assays for antibodies against (SARS-CoV-2) have emerged. We sought to examine 5 widely used commercial methods. We measured antibodies against SARS-CoV-2 with assays, Abbott-IgG, Roche-IgT (total antibodies, isotype-unspecific), EUROIMMUN-IgG, EUROIMMUN-IgA, DiaSorin-IgG, in 191 serum samples from patients with rRT-PCR proven COVID-19 between days 0 and 47 after the onset of clinical symptoms and in biobank samples collected in 2018. The assays were calibrated using the manufacturers' instructions; results are in multiples of the assay specific cut-offs (Abbott, Roche, EUROIMMUN) or in arbitrary units (AU/mL, DiaSorin). The assays for IgG and IgT have approximately the same sensitivity and specificity for detecting seroconversion which starts at approximately day 3 after symptom onset, sensitivity reached 93% on day 16 and was 100% for each assay on day 20. The assay for IgA antibodies was superior in sensitivity and had a lower specificity than the others. Bivariate non-parametric correlation coefficients ranged between 0.738 and 0.991. Commercial assays for IgG or total antibodies against SARS-CoV-2 are largely equivalent for establishing seroconversion but differ at high antibody titres. Increased sensitivity to detect seroconversion is afforded by including IgA antibodies. Further international efforts to harmonise assays for antibodies against SARS-CoV-2 are urgently needed.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Pruebas Diagnósticas de Rutina/métodos , Femenino , Humanos , Inmunoglobulina A/sangre , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Masculino , Persona de Mediana Edad , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Seroconversión
3.
PLoS One ; 14(1): e0211207, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-30689658

RESUMEN

Clinical flow cytometry is a reliable methodology for whole blood cell phenotyping for different applications. The BD FACSLyric™ system comprises a flow cytometer available in different optical configurations, BD FACSuite™ Clinical software, and optional BD FACS™ Universal Loader. BD FACSuite Clinical software used with BD™ FC Beads and BD CS&T Beads enable universal setup for performance QC, instrument control, data acquisition/storage, online/offline data analysis, and instrument standardization. BD Biosciences sponsored the clinical evaluation of the BD FACSLyric 10-color configuration at seven clinical sites using delinked and de-identified blood specimens from HIV-infected and uninfected subjects to enumerate T-, B-, and NK-lymphocytes with the BD Multitest™ reagents (BD Multitest IMK kit and BD Multitest 6-color TBNK). Samples were analyzed on the BD FACSLyric system with BD FACSuite Clinical software, and on the BD FACSCanto™ II system with BD FACSCanto clinical software and BD FACS 7-Color Setup beads. For equivalency between methods, data (n = 362) were analyzed with Deming regression for absolute count and percentage of lymphocytes. Results gave R2 ≥0.98, with slope values ≥0.96, and slope ranges between 0.90-1.05. The percent (%) bias values were <10% for T- and NK cells and <15% for B- cells. The between-site (n = 4) total precision was tested for 5 days (2 runs/day), and gave %coefficient of variation below 10% for absolute cell counts. The stability claims were confirmed (n = 186) for the two BD Multitest reagents. The reference intervals were re-established in male and female adults (n = 134). The analysis by gender showed statistically significant differences for CD3+ and CD4+ T-cell counts and %CD4. In summary, the BD FACSLyric and the BD FACSCanto II systems generated comparable measurements of T-, B-, and NK-cells using BD Multitest assays.


Asunto(s)
Linfocitos B/citología , Recuento de Células/métodos , Células Asesinas Naturales/citología , Linfocitos T/citología , Linfocitos T CD4-Positivos/citología , Recuento de Células/normas , Citometría de Flujo , Infecciones por VIH/sangre , Infecciones por VIH/diagnóstico , Infecciones por VIH/inmunología , Humanos , Juego de Reactivos para Diagnóstico , Estándares de Referencia , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...