1.
Rapid Commun Mass Spectrom ; 16(21): 2060-6, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12391581

RESUMEN

Triple quadrupole mass spectrometers, when operated in multiple reaction monitoring (MRM) mode, offer a unique combination of sensitivity, specificity, and dynamic range. Consequently, the triple quadrupole is the workhorse for high-throughput quantitation within the pharmaceutical industry. However, in the past, the unit mass resolution of quadrupole instruments has been a limitation when interference from matrix or metabolites cannot be eliminated. With recent advances in instrument design, triple quadrupole instruments now afford mass resolution of less than 0.1 Dalton (Da) full width at half maximum (FWHM). This paper describes the evaluation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput bioanalysis with emphasis on comparison of selectivity, sensitivity, dynamic range, precision, accuracy, and stability under both unit mass (1 Da FWHM) and enhanced (

Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masa por Ionización de Electrospray/métodos , Calibración , Loratadina/análisis , Furoato de Mometasona , Preparaciones Farmacéuticas/análisis , Piperidinas/análisis , Pregnadienodioles/análisis , Piridinas/análisis , Sensibilidad y Especificidad
2.
Rapid Commun Mass Spectrom ; 16(21): 2067-72, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12391582

RESUMEN

A 60 microm internal diameter (i.d.) stainless-steel needle was adapted to the orthogonal ESI probe ( microESI) of a commercial ion trap mass spectrometer, and used for capillary liquid chromatography/tandem mass spectrometry (LC/MS/MS) protein identification experiments. The modification allows for the use of nitrogen sheath gas which helps in the nebulization at LC flow rates exceeding 500 nL/min and eliminates problems caused by liquid junctions commonly used to initiate nanospray ionization (NSI). A comparison is made between the performance of a 75 microm i.d. column with a 15 microm pulled glass tip using a liquid junction, and that of a 150 microm i.d. column using the new microESI device. The combination of the 150 microm i.d. column and microESI gave sensitivity close to that of NSI (250 attomoles horse heart myoglobin digest on column), and proved to be more robust than the standard pulled glass tips of similar i.d. No evidence of metal needle catalyzed oxidation of methionine was observed during analysis of the tetrapeptide MRFA under a range of test conditions. Phosphorylated peptides in a beta-casein tryptic digest were also successfully identified using the microESI interface with a steel needle. In addition it was found that a mild sanding of the metal needle tip improved spray performance.


Asunto(s)
Cromatografía Líquida de Alta Presión/métodos , Nanotecnología/métodos , Proteómica , Espectrometría de Masa por Ionización de Electrospray/métodos , Animales , Caballos , Metionina/química , Mioglobina/análisis , Oxidación-Reducción , Péptidos/análisis , Péptidos/química , Fosforilación , Sensibilidad y Especificidad , Espectrometría de Masa por Ionización de Electrospray/instrumentación