Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Dtsch Arztebl Int ; 118(8): 117-121, 2021 02 26.
Artículo en Inglés | MEDLINE | ID: mdl-33879309

RESUMEN

BACKGROUND: E-scooter sharing systems were initiated in Hamburg in June 2019. The number of persons injured in Hamburg in e-scooter accidents rose thereafter. The goal of this study was to determine the typical accident mechanisms and injury patterns after e-scooter accidents in Germany, and to compare these with bicycle accidents. METHODS: In a retrospective study, accidents with e-scooters and bicycles that occurred from June 2019 to June 2020 were registered and analyzed with respect to demography, accident mechanisms, diagnostics, patterns of injury, emergency medical care, operations, and inpatient hospitalizations. RESULTS: 89 persons sustained e-scooter accidents (mean age 33.9 years, standard deviation [SD] 14 years); 435 persons who sustained bicycle accidents (mean age 42.5 years, SD 17 years) served as a comparison group. E-scooter accidents more commonly occurred at night (37% versus 14%), and 28% of the persons who sustained them were under the influence of alcohol (cyclists: 6%). 54% of the injured e-scooter riders suffered trauma to the head or face; 14% had a severe head injury and 16% had a severe facial injury. Fractures of the upper limbs were more common than fractures of the lower limbs (18% versus 6%). On initial assessment in the emergency room, injured cyclists were more frequently classified as needing immediate treatment than injured e-scooter riders (7% versus 1%). CONCLUSION: The head, face, and upper limbs are the most commonly affected parts of the body in e-scooter accidents. Compared to bicycle accidents, e-scooter accidents more commonly occur on weekends and in association with alcohol. From a medical point of view, abstaining from alcohol consumption and wearing a helmet when using an e-scooter is strongly recommended.


Asunto(s)
Traumatismos Craneocerebrales , Dispositivos de Protección de la Cabeza , Accidentes , Accidentes de Tránsito , Adulto , Alemania/epidemiología , Humanos , Estudios Retrospectivos
2.
Knee Surg Sports Traumatol Arthrosc ; 25(7): 2025-2031, 2017 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-26685688

RESUMEN

PURPOSE: To evaluate different stabilisation techniques for acromioclavicular (AC) joint separations, including direct AC repair, and to compare the properties of the stabilised and native joints. METHODS: An established in vitro testing model for the AC joint was used to analyse joint stability after surgical reconstruction [double TightRope (DTR), DTR with AC repair (DTR + AC), single TR with AC repair (TR + AC), and PDS sling with AC repair (PDS + AC)]. Twenty-four human cadaveric shoulders were randomised by age into four testing groups. Joint stiffness was measured by applying an axial load during defined physiological ranges of motion. Similar tests were performed for the native joints, after dissecting the coracoclavicular and AC ligaments, and after surgical reconstruction. Cyclic loading was performed for 1000 cycles with 20-70 N and vertical load to failure determined after cyclic testing. RESULTS: Axial stiffness for all TR groups was significantly higher than for the native joint (DTR 38.94 N/mm, p = 0.005; DTR + AC 37.79 N/mm, p = 0.015; TR + AC 45.61 N/mm, p < 0.001 vs. native 26.05 N/mm). The axial stiffness of the PDS + AC group was similar to that of the native joint group (21.4 N/mm, n.s.). AC repair did not significantly influence rotational stiffness. Load to failure was similar and >600 N in all groups (n.s.). CONCLUSION: Reconstruction of AC dislocations with one or two TRs leads to stable results with a higher stiffness than the native joints. For the PDS + AC group, axial stiffness was similar to the native situation, although there might be a risk of elongation. Direct AC repair showed no significantly increased stability in comparison with reconstructions without direct AC repair. Thus, a direct AC repair seems to be dispensable in clinical practice, while TRs or PDS cerclages appear to provide sufficiently stable results.


Asunto(s)
Articulación Acromioclavicular/cirugía , Luxaciones Articulares/cirugía , Ligamentos Articulares/cirugía , Ensayo de Materiales , Dispositivos de Fijación Ortopédica , Cinta Quirúrgica , Adulto , Anciano , Fenómenos Biomecánicos , Cadáver , Femenino , Humanos , Inestabilidad de la Articulación/cirugía , Masculino , Persona de Mediana Edad , Distribución Aleatoria , Soporte de Peso
3.
Arch Orthop Trauma Surg ; 135(8): 1101-6, 2015 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-26054619

RESUMEN

INTRODUCTION: Due to the demographic trend, pertrochanteric fractures of the femur will gain increasing importance in the future. Both extra- and intramedullary implants are used with good results in the treatment of these fractures. New, angular stable extramedullary implants promise increased postoperative stability even with unstable fractures. Additional trochanteric plates are intended to prevent secondary impaction, varisation and shortening of the fracture, as well as medialisation of the femoral shaft. The aim of this study was to perform a biomechanical comparison of both procedures regarding their postoperative stability and failure mechanisms. MATERIALS AND METHODS: Twelve fresh-frozen human femurs were randomized into two groups based on the volumetric bone mineral density (vBMD). Standardized pertrochanteric fractures (AO31-A2.3) were generated and treated either with an angular stable dynamic hip screw (DHS) or an intramedullary nail (nail). Correct implant position and the tip-apex distance (TAD) were controlled postoperatively using X-ray. Specimens were mounted in a servohydraulic testing machine and an axial loading was applied according to a single-leg stance model. Both groups were biomechanically compared with regard to native and postoperative stiffness, survival during cyclic testing, load to failure, and failure mechanisms. RESULTS: TAD, vBMD, and native stiffness were similar for both groups. The stiffness decreased significantly from native to postoperative state in all specimens (p < 0.001). The postoperative stiffness of both groups varied non-significantly (p = 0.275). The failure loads for specimens treated with the nail were significantly higher than for those treated with the DHS (8480.8 ± 1238.9 N vs. 2778.2 ± 196.8 N; p = 0.008). CONCLUSIONS: Extra- and intramedullary osteosynthesis showed comparable results as regards postoperative stiffness and survival during cyclic testing. Since the failure load of the nail was significantly higher in the tested AO31-A2.3 fracture model, we conclude that intramedullary implants should be preferred in these, unstable, fractures.


Asunto(s)
Tornillos Óseos , Fracturas del Fémur/cirugía , Fijación Interna de Fracturas/instrumentación , Fijación Intramedular de Fracturas/instrumentación , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Femenino , Fracturas del Fémur/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Radiografía , Distribución Aleatoria , Soporte de Peso
4.
J Orthop Trauma ; 28(5): 276-82, 2014 May.
Artículo en Inglés | MEDLINE | ID: mdl-24751606

RESUMEN

OBJECTIVES: The aim of this investigation was to perform a biomechanical comparison between 1- and 2-screw systems used for the treatment of intertrochanteric fractures for centralized and decentralized placement of femoral neck screws of failure loads, stiffness, survival rates, tip apex distance (TAD), and failure mode. METHODS: As fracture model, an AO 31A2.3 fracture was used. Twelve pairs of human cadaver femora were tested. Femoral neck screws were implanted in the femoral head in center/center, posterior/central, and anterior/superior position in axial/frontal plane. A single-screw system (Gamma 3 Locking Nail; Stryker GmbH & Co. KG) and a 2-screw system (Trigen-Intertan; Smith & Nephew GmbH) were used. To simulate the load in situ, a cyclic load was carried for 10,000 cycles in a material testing machine. If no cyclic failure occurred, femora were loaded until the failure. The systems were compared according to the stiffness, survivability through 10 k cycles, TAD, and load to failure. RESULTS: None of the tested bones failed at center/center location in the decentralized positions 3 Gamma Nail and 2 Intertan specimens failed during cyclic testing. The 2-screw system resisted higher forces in all positions (Gamma: 5370N ± 1924, Intertan: 7650N ± 2043; P = 0.014). CONCLUSIONS: Based on these data, it is clear that both the nail systems showed a higher biomechanical stability with a lower TAD. The 2 specimens that failed with the Intertan in the cyclic tests had a TAD ≥49 mm. The cutout failures that we detected during cyclic testing in the Gamma system had a TAD ≥30 mm. Thus, it is clear that the TAD affects failure independent of the implant used. With a less than ideal lag screw placement, however, the Intertan system with 2 integrated screws was able to withstand higher loads in this study.


Asunto(s)
Fijación Intramedular de Fracturas/efectos adversos , Fijación Intramedular de Fracturas/instrumentación , Fracturas de Cadera/cirugía , Fenómenos Biomecánicos , Tornillos Óseos , Cadáver , Femenino , Fracturas de Cadera/fisiopatología , Humanos , Masculino , Persona de Mediana Edad
5.
Am J Sports Med ; 41(6): 1387-94, 2013 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-23618701

RESUMEN

BACKGROUND: Traumatic acromioclavicular (AC) joint dislocations can be addressed with several surgical stabilization techniques. The aim of this in vitro study was to evaluate biomechanical features of the native joint compared with 3 different stabilization methods: locking hook plate (HP), TightRope (TR), and bone anchor system (AS). HYPOTHESIS: The HP provides higher stiffness than the anatomic reconstruction techniques. STUDY DESIGN: Controlled laboratory study. METHODS: A new biomechanical in vitro model of the AC joint was used to analyze joint stability after surgical repair (HP, TR, and AS). Eighteen cadaveric specimens were randomized for bone density and diameter in the midclavicle section. Joint stiffness was measured by applying an axial load and a defined physiological range of motion for internal and external rotations and upward and downward rotations. Data were recorded at 3 stages: for the native joint after dissecting the AC ligaments, directly after repair, and after axial cyclic loading (1000 cycles with 20 and 70 N at 1 Hz). To evaluate which implant mimics physiological joint properties best, axial stiffness of vertical stability was assessed in combination with rotation. Finally, static loading in the superior direction was applied until failure of the joints occurred. RESULTS: Axial stiffness of the TR and AS groups was 2-fold higher than for the HP group and the native joint (67.1, 66.1, and 22.5 N/mm, respectively; P < .004). Decreased load-to-failure rates were recorded in the HP group compared with the TR and AS groups (248.9 ± 72.7, 832.0 ± 401.4, and 538.0 ± 166.1 N, respectively). The stiffness of the rotations was not significantly different between the treatment methods but was lower in horizontal and downward rotations compared with the native state. Thus, native AC ligaments contributed a significant share to joint stiffness. CONCLUSION: The TR and AS groups demonstrated higher vertical load capacity. Compared with the TR and AS, the HP demonstrated an axial stiffness closest to the native joint. For restoring physiological properties, reconstruction of the AC ligaments may be necessary. CLINICAL RELEVANCE: The results show different biomechanical properties of the HP and anatomic reconstructions.


Asunto(s)
Articulación Acromioclavicular/fisiopatología , Articulación Acromioclavicular/cirugía , Inestabilidad de la Articulación/cirugía , Luxación del Hombro/fisiopatología , Luxación del Hombro/cirugía , Análisis de Varianza , Fenómenos Biomecánicos , Cadáver , Humanos , Inestabilidad de la Articulación/etiología , Procedimientos Ortopédicos/métodos , Rango del Movimiento Articular , Rotación , Luxación del Hombro/complicaciones
6.
Comput Aided Surg ; 16(6): 280-7, 2011.
Artículo en Inglés | MEDLINE | ID: mdl-21991920

RESUMEN

Navigation in hand surgery is still in the process of development. Initial studies have demonstrated the feasibility of 2D and 3D navigation for the palmar approach in scaphoid fractures, but a comparison of the possibilities of 2D and 3D navigation for the dorsal approach is still lacking. The aim of the present work was to test navigation for the dorsal approach in the scaphoid using cadaver bones. After development of a special radiolucent resting splint for the dorsal approach, we performed 2D- and 3D-navigated scaphoid osteosynthesis in 12 fresh-frozen cadaver forearms using a headless compression screw (Synthes). The operation time, radiation time, number of trials for screw insertion, and screw positions were analyzed. In six 2D-navigated screw osteosyntheses, we found two false positions with an average radiation time of 5 ± 2 seconds. Using 3D navigation, we detected one false position. A false position indicates divergence from the ideal line of the axis of the scaphoid but without penetration of the cortex. The initial scan clearly increased overall radiation time in the 3D-navigated group, and for both navigation procedures operating time was longer than in our clinical experience without navigation. Nonetheless, 2D and 3D navigation for non-dislocated scaphoid fractures is feasible, and navigation might reduce the risk of choosing an incorrect screw length, thereby possibly avoiding injury to the subtending cortex. The 3D navigation is more difficult to interpret than 2D fluoroscopic navigation but shows greater precision. Overall, navigation is costly, and the moderate advantages it offers for osteosynthesis of scaphoid fractures must be considered critically in comparisons with conventional operating techniques.


Asunto(s)
Tornillos Óseos , Fijación Interna de Fracturas/instrumentación , Imagenología Tridimensional/instrumentación , Hueso Escafoides/cirugía , Cirugía Asistida por Computador/instrumentación , Cadáver , Distribución de Chi-Cuadrado , Diagnóstico por Computador , Estudios de Factibilidad , Femenino , Fijación Interna de Fracturas/métodos , Humanos , Imagenología Tridimensional/métodos , Masculino , Persona de Mediana Edad , Hueso Escafoides/lesiones , Cirugía Asistida por Computador/métodos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...