1.
J Clin Oncol ; 38(34): 4120-4129, 2020 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33052755

RESUMEN

An important challenge in the field of cancer is finding the balance between delivering effective treatments and avoiding adverse effects and financial toxicity caused by innovative, yet expensive, drugs. To address this, several treatment de-escalation trials have been conducted, but only a few of these have provided clear answers. A few trials had poor accrual or had design flaws that led to conflicting results. Members of the Breast International Group (BIG) and North American Breast Cancer Group (NABCG) believe the way forward is to understand the lessons from these trials and listen more carefully to what truly matters to our patients. We reviewed several adjuvant trials of different cancer types and developed a road map for improving the design and implementation of future de-escalation trials. The road map incorporates patients' insights obtained through focused group discussions across the BIG-NABCG networks. Considerations for the development of de-escalation trials for systemic adjuvant treatment, including noninferiority trial design, choice of end points, and prioritization of a patient's perspectives, are presented in this consensus article.


Asunto(s)
Antineoplásicos/administración & dosificación , Neoplasias/tratamiento farmacológico , Quimioterapia Adyuvante , Humanos , Ensayos Clínicos Controlados Aleatorios como Asunto
2.
Intensive Care Med ; 30(6): 1182-7, 2004 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-15004667

RESUMEN

OBJECTIVE: The purpose of this study was to determine whether monitoring of respiratory changes in aortic blood flow velocity, recorded by esophageal Doppler, could be used to detect changes in volume depletion. DESIGN: Animal study. ANIMALS AND INTERVENTIONS: After general anesthesia and tracheotomy, ten New Zealand female rabbits, weighing 4-4.5 kg were studied under mechanical ventilation at a fixed tidal volume; during this time 5-ml blood samples were withdrawn (in increments up to a total of 30 ml) and then retransfused. MEASUREMENTS AND RESULTS: At each step, systolic (SBP), diastolic (DBP), pulse (PP) pressures and maximum descending aortic blood flow (V) were recorded. Respiratory changes of V (DeltaV), SBP (DeltaSBP) and PP (DeltaPP) were calculated as the difference of maximal and minimal values divided by their respective means and expressed as a percentage. The amount of blood withdrawn correlated negatively with SBP, DBP, PP and V and positively with DeltaSBP, DeltaPP and DeltaV. Among these parameters, DeltaV correlated best with the amount of blood withdrawn ( r=0.89, p<0.001) and it was the most accurate index of volume depletion. CONCLUSION: Monitoring of the respiratory variation in V, calculated by esophageal Doppler technique, seems to be a highly accurate index of blood volume depletion and restitution.


Asunto(s)
Aorta Torácica/diagnóstico por imagen , Velocidad del Flujo Sanguíneo , Ecocardiografía Transesofágica , Hipovolemia/diagnóstico por imagen , Volumen Sistólico , Análisis de Varianza , Animales , Femenino , Hemodinámica , Hipovolemia/fisiopatología , Monitoreo Fisiológico/métodos , Respiración con Presión Positiva , Conejos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS