Can J Cardiol ; 30(9): 1108.e1-3, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-24629491

RESUMEN

Transcatheter aortic valve implantation (TAVR) has grown rapidly over the past 10 years. Device and delivery catheter systems have evolved to facilitate the procedure and reduce the risk of associated complications, including those related to vascular access. It is important to understand the utility of the TAVR equipment in patients with more challenging anatomy to select the most appropriate technique for this complex procedure. We report the first case, to our knowledge, of a patient with dextrocardia situs inversus and previous coronary artery bypass grafting who underwent TAVR from the femoral route using the Edwards SAPIEN XT Novaflex+ Transfemoral System (Edwards Lifesciences, Irvine, CA).


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Dextrocardia/complicaciones , Puente de Arteria Coronaria , Arteria Femoral , Humanos , Masculino , Persona de Mediana Edad , Implantación de Prótesis/métodos , Situs Inversus/complicaciones