Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
1.
Clin Oral Investig ; 25(3): 1265-1272, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-32651646

RESUMEN

OBJECTIVES: Conventional dental implants inserted in the molar region of the maxilla will reach into the sinus maxillaris when alveolar ridge height is limited. When surgery is performed without prior augmentation of the sinus floor, primary stability of the implant is important for successful osseointegration. This study aimed at identifying the impact of bone quality and quantity at the implantation site on primary implant stability of a simulated bicortical placement. MATERIALS AND METHODS: In our in vitro measurements, bone mineral density, total bone thickness and overall cortical bone thickness were assessed by micro-computed tomography (µCT) of pig scapulae, which resembled well the bicortical situation found in human patients. Dental implants were inserted, and micromotion between bone and implant was measured while loading the implant with an axial torque. RESULTS: The main findings were that primary implant stability did not depend on total bone thickness but tended to increase with either increasing bone mineral density or overall cortical bone thickness. CLINICAL RELEVANCE: Limited bone height in the maxilla is a major problem when planning dental implants. To overcome this problem, several approaches, e.g. external or internal sinus floor elevation, have been established. When planning the insertion of a dental implant an important aspect is the primary stability which can be expected. With other factors, the dimensions of the cortical bone might be relevant in this context. It would, therefore, be helpful to define the minimum thickness of cortical bone required to achieve sufficient primary stability, thus avoiding additional surgical intervention.


Asunto(s)
Implantes Dentales , Elevación del Piso del Seno Maxilar , Animales , Implantación Dental Endoósea , Retención de Prótesis Dentales , Fracaso de la Restauración Dental , Humanos , Maxilar/cirugía , Seno Maxilar/cirugía , Porcinos , Microtomografía por Rayos X
2.
Knee ; 24(5): 1016-1024, 2017 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-28793976

RESUMEN

BACKGROUND: Aseptic loosening is the major reason for failure of distal femoral replacement using current modular megaprostheses. Although the same stems are used for proximal and distal replacement, survival rates in clinical studies with distal reconstruction were lower within the same system compared to proximal reconstruction. We analyzed whether primary stability as presupposition for long-term fixation can be achieved with a current tapered stem design. Additionally, we hypothesized that stem length affects primary stability depending on bone defect situations. METHODS: A modular tumor system (Megasystem-C®, Link GmbH, Hamburg, Germany) with two different tapered stems (100 and 160mm) was implanted in eight Sawbones® in two consecutively created defect situations (10 and 20cm proximal to knee joint level). Primary rotational stability was investigated by measuring relative micromotions between implant and bone to identify the main fixation areas and to characterize the fixation pattern. RESULTS: The fixation differed between the two stem lengths and with respect to both defect situations; however in each case the main fixation area was located at or close to the femoral isthmus. Highest relative micromotions were measured with the 160-mm stem at the distal end within small bone defects and at the proximal end when defects were increased. CONCLUSIONS: The analyzed design seemed to create sufficient primary stability along the main fixation areas of the implant. Based on these results and with respect to oncologic or potential revision situations, we suggest the use of the shorter stem to be more favorable in case of primary implant fixation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Neoplasias Óseas/cirugía , Fémur/cirugía , Diseño de Prótesis , Artroplastia de Reemplazo de Rodilla/efectos adversos , Humanos , Técnicas In Vitro , Prótesis de la Rodilla , Modelos Anatómicos , Falla de Prótesis , Rotación , Heridas y Lesiones/cirugía
3.
PLoS One ; 12(5): e0177285, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28481956

RESUMEN

INTRODUCTION: Revision total knee arthoplasty often requires modular implants to treat bone defects of varying severity. In some cases, it may not be clear which module size and implant combination (e.g. sleeve and stem) should be chosen for a specific defect. When balancing implant stability and osseointegration against stress-shielding, it is important to choose an appropriate implant combination in order to match the given level of bone loss. Therefore, the necessity of stems in less extensive tibial defects and the advantage of different stems (lengths and stiffnesses) in combination with large metaphyseal sleeves on implant fixation and bone flexibility using a modular tibial revision knee system, were analyzed. MATERIALS AND METHODS: Four different stem combinations for a tibial revision implant (Sigma TC3, DePuy) were compared to an intact bone. Standardized implantation with n = 4 synthetic tibial bones was performed after generating an Anderson Orthopaedic Research Institute (AORI) Type T1 bone defect. Axial torques around the longitudinal stem axis and varus-valgus torques were separately applied to the implant. Micromotions of bone and implant were tracked using a digital image correlation system to calculate relative micromotions at the implant-bone-interface and bone deformation. RESULTS: Overall, using stems reduced the proximal micromotions of tray and sleeve compared to no stem, while reducing bone deformation proximally at the same time, indicating some potential for proximal stress-shielding compared to no stem. The potential for increased proximal stress-shield due to reduced proximal deformation appeared to be greater when using the longer stems. The location of lowest relative micromotions was also more distal when using long stems as opposed to short stems. A short stem (especially a smaller diameter short stem which still achieves diaphyseal fixation) displayed less potential for stress-shielding, but greater bone deformation distal to the tip of the stem than in the natural model. DISCUSSION: In the case of tibial revision implants with metaphyseal sleeves in a simple fully contained Type I defect, the absence of a stem provides for more natural bone deformation. However, adding a stem reduces overall relative micromotions, while introducing some risk of proximal stress-shielding due to increased diaphyseal fixation. Increasing stem length intensifies this effect. Short stems offered a balance between reduced micromotions and more proximal bone deformation that reduced the potential for stress-shielding when compared to long stems. A short stem with slightly smaller diameter (simulating a less stiff stem which still has diaphyseal fixation) increased the proximal bone deformation, but also tended to increase the bone deformation even further at the distal stem's tip. CONCLUSION: In conclusion, further investigation should be conducted on fully contained Type I defects and the addition of a stem to offer better initial stability, taking into account stem length (i.e. shorter or more flexible stems) to support metaphyseal fixation and allowing bending found in intact bone. In addition, further study into more extensive tibial defects is required to determine if the stability/micromotion trends observed in this study with stems and sleeves in Type I defects still apply in cases of extensive proximal bone loss.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/métodos , Prótesis de la Rodilla , Diseño de Prótesis , Tibia/cirugía , Artroplastia de Reemplazo de Rodilla/instrumentación , Humanos , Técnicas In Vitro
4.
Int J Artif Organs ; 39(10): 534-540, 2016 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-27834448

RESUMEN

BACKGROUND: Due to the varying bone defects presented to surgeons during revision total knee arthroplasty, modular implant systems are preferred over standard implant designs. However, every implant combination (sleeves, stems and augments) can affect the fixation in different ways and thus influence the long-term outcome. We therefore aimed to analyze the effect of large metaphyseal sleeves with and without short modular stems on implant fixation and bone flexibility of a modular tibial revision knee system. METHODS: A new tibial revision implant (Attune RP Revision; DePuy Synthes) with a sleeve was compared to a sleeve/stem combination implanted in synthetic bones with Anderson Orthopaedic Research Institute (AORI) Type T2a defects and also compared to an intact bone. Implant-bone-interface micromotions and bone deformations during standardized load application were measured using a digital image correlation system. RESULTS: The lowest relative micromotions were measured more distally for stemmed implants, and more proximally for the stemless group. When compared to an intact bone, there is increased proximal bone deformation in the stemless group. CONCLUSIONS: Using a short stem in addition to a tibial revision implant with a metaphyseal sleeve in a moderate bone defect provides for more natural bone deformation. Although the main fixation area was shifted distally, relative micromotions were reduced. Based on this biomechanical study, the use of diaphyseal short stems with metaphyseal sleeves seems to be beneficial in terms of the initial implant fixation and for its flexibility, which is similar to that of intact bones in the case of AORI T2a defects.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/instrumentación , Prótesis de la Rodilla , Diseño de Prótesis , Humanos , Ensayo de Materiales , Modelos Biológicos , Reoperación , Rotación
5.
BMC Musculoskelet Disord ; 16: 371, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26627999

RESUMEN

BACKGROUND: Short stems have become more and more popular for cementless total hip arthroplasty in the past few years. While conventional, uncemented straight stems for primary total hip arthroplasty (THA) have shown high survival rates in the long term, it is not known whether uncemented short stems represent a reasonable alternative. As cortical hypertrophy has been reported for short stems, the aim of this study was to determine the radiographic prevalence of cortical hypertrophy and to assess the clinical outcome of a frequently used short, curved hip stem. METHODS: We retrospectively studied the clinical and radiographic results of our first 100 consecutive THAs (97 patients) using the Fitmore® hip stem. Mean age at the time of index arthroplasty was 59 years (range, 19 - 79 years). Clinical outcome and radiographic results were assessed with a minimum follow-up of 2 years, and Kaplan-Meier survivorship analysis was used to estimate survival for different endpoints. RESULTS: After a mean follow-up of 3.3 years (range, 2.0 - 4.4 years), two patients (two hips) had died, and three patients (four hips) were lost to follow-up. Kaplan-Meier analysis estimated a survival rate of 100 % at 3.8 years, with revision for any reason as the endpoint. No femoral component showed radiographic signs of loosening. No osteolysis was detected. Cortical hypertrophy was found in 50 hips (63 %), predominantly in Gruen zone 3 and 5. In the cortical hypertrophy group, two patients (two hips; 4 %) reported some thigh pain in combination with pain over the greater trochanter region during physical exercise (UCLA Score 6 and 7). There was no significant difference concerning the clinical outcome between the cortical hypertrophy and no cortical hypertrophy group. CONCLUSIONS: The survival rate and both clinical and the radiographic outcome confirm the encouraging results for short, curved uncemented stems. Postoperative radiographs frequently displayed cortical hypertrophy but it had no significant effect on the clinical outcome in the early follow-up. Further clinical and radiographic follow-up is necessary to detect possible adverse, long-term, clinical effects of cortical hypertrophy.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Articulación de la Cadera/cirugía , Prótesis de Cadera , Adulto , Anciano , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Articulación de la Cadera/diagnóstico por imagen , Articulación de la Cadera/fisiopatología , Humanos , Hipertrofia , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Dolor Postoperatorio/diagnóstico por imagen , Diseño de Prótesis , Falla de Prótesis , Radiografía , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Adulto Joven
6.
Int Orthop ; 39(9): 1819-25, 2015 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-26156721

RESUMEN

PURPOSE: Femoral defects often make it difficult to achieve sufficient fixation of the stem during revision surgery. No clinical studies comparing modular stems are available and differentiated recommendations are rare. The aim of this study was to compare the fixation of different revision stems in an experimental and standardised manner. METHODS: Segmental AAOS type I and III defects were reproduced in four femur pairs and two modular stems of different shape (cylindrical and conical) were implanted. Interfacial stem-bone movements were measured under axial torque application to analyze the stem fixation depending on defect extension. RESULTS: Both stems showed adequate fixation in AAOS type I defect. The defect extension significantly reduced the fixation of both implants. The fixation pattern changed significantly for the cylindrical-shaped stem but was maintained for the conical-shaped stem. CONCLUSIONS: Shape as well as the extension of femoral defect have an impact on primary fixation. A type I defect seems to be bridgeable for both stems albeit in a different way. In contrast, stem-demanding activities during the healing phase have to be avoided for the conical-shaped stem in a type III defect, whereas the cylindrical-shaped stem has already ceased to be sufficiently stable in this case.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Fémur/cirugía , Diseño de Prótesis , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Artroplastia de Reemplazo de Cadera/efectos adversos , Femenino , Prótesis de Cadera , Humanos , Masculino , Persona de Mediana Edad , Reoperación , Torque
7.
PLoS One ; 10(6): e0129149, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-26030460

RESUMEN

PURPOSE: Fixation of proximal femoral megaprostheses is achieved in the diaphyseal isthmus. We hypothesized that after extended bone resection including the proximal part of the isthmus a reduced length of fixation will affect the stability and fixation characteristics of these megaprostheses. The aim of this study was to analyze in a validated sawbone model with extended proximal femoral defects which types of implants have sufficient primary stability to allow osteointegration and to describe their fixation characteristics. METHODS: Four different cementless megaprostheses were implanted into 16 Sawbones with an AAOS type III defect after resection 11 cm below the lesser trochanter involving the proximal isthmus. To determine the primary implant stability relative micromotions between bone and implant were measured in relation to a cyclic torque of 7Nm applied on the longitudinal axis of the implant. We determined the fixation characteristics of the different implant designs by comparing these relative micromotions along the longitudinal stem axis. RESULTS: In the tested sawbones all studied implants showed sufficient primary stability to admit bone integration with relative micromotions below 150 µm after adapting our results to physiologic hip joint loadings. Different fixation characteristics of the megaprostheses were determined, which could be explained by their differing design and fixation concepts. CONCLUSIONS: Cementless megaprostheses of different designs seem to provide sufficient primary stability to bridge proximal femoral defects if the diaphyseal isthmus is partially preserved. In our sawbone model the different implant fixation patterns can be related to their stem designs. No evidence can be provided to favor one of the studied implants in this setting. However, femoral morphology is variable and in different isthmus configurations specific implant designs might be appropriate to achieve the most favorable primary stability, which enables bone integration and consequently long term implant stability.


Asunto(s)
Fracturas del Cuello Femoral/fisiopatología , Fracturas del Cuello Femoral/cirugía , Fracturas Óseas/fisiopatología , Fracturas Óseas/cirugía , Prótesis de Cadera , Rotación , Fenómenos Biomecánicos , Humanos , Modelos Biológicos , Diseño de Prótesis
8.
Int Orthop ; 38(6): 1147-53, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24384941

RESUMEN

PURPOSE: In total hip arthroplasty fixation of revision stems can be demanding due to femoral bone loss. Strut grafts are often used for bone augmentation and stabilization of the newly inserted prosthesis. The aim of this study was to assess the effect of strut grafts on primary stability under various stem fixation conditions. METHODS: Two different revision stems (cylindrical and conical shape) were implanted into synthetic femora. Following a semicircular transfemoral osteotomy, three deficient femoral bearings were simulated (bony lid reattached with cable wires; weakened lid reattached with cable wires; strut grafts placed to the weakened lid with cable wires). Relative micro-movements were measured between prostheses and bones due to an axial moment applied to the stems. RESULTS: Relative movements correlated to the stem shape. The cylindrical stem showed higher movements increasing significantly with a weakened bony lid and portrayed a slight decrease of movements with strut graft application. No unequivocal influence of the weakened lid could be detected for the conical implant. Strut graft application did not show an additional stabilizing effect. CONCLUSIONS: The primary stability of the cylindrical fixation concept decreases with impaired fixation conditions of the femur. A clear restabilizing effect with strut grafts could not be proven. A decrease of primary stability due to the impaired bone could not be observed for the conical stem shape. Additionally, strut grafts do not enhance fixation for this stem shape. We conclude that surgeons should not rely on a stabilizing effect of strut grafts in revision hip surgery.


Asunto(s)
Artroplastia de Reemplazo de Cadera/métodos , Resorción Ósea/cirugía , Trasplante Óseo , Fémur/cirugía , Artroplastia de Reemplazo de Cadera/efectos adversos , Resorción Ósea/etiología , Prótesis de Cadera , Humanos , Diseño de Prótesis , Reoperación
9.
Int Orthop ; 38(3): 483-8, 2014 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-24146175

RESUMEN

PURPOSE: After clinical introduction of the Fitmore stem (Zimmer), we noticed the formation of cortical hypertrophies in a few cases. We questioned whether (1) the primary stability or (2) load transfer of the Fitmore stem differs from other stems unassociated with the formation of hypertrophies. We compared the Fitmore stem to the well-established CLS stem. METHODS: Four Fitmore and four CLS stems were implanted in eight synthetic femurs. A cyclic torque around the stem axis and a mediolateral cyclic torque were applied. Micromotions between stems and femurs were measured to classify the specific rotational implant stability and to analyse the bending behaviour of the stem. RESULTS: No statistical differences were found between the two stem designs with respect to their rotational stability (p = 0.82). For both stems, a proximal fixation was found. However, for the mediolateral bending behavior, we observed a significantly (p < 0.01) higher flexibility of the CLS stem compared to the Fitmore stem. CONCLUSION: Hip stem implantation may induce remodelling of the periprosthetic bone structure. Considering the proximal fixation of both stems, rotational stability of the Fitmore® stem might not be a plausible explanation for clinically observed formation of hypertrophies. However, bending results support our hypothesis that the CLS stem presumably closely follows the bending of the bone, whereas the shorter Fitmore stem acts more rigidly. Stem rigidity and flexibility needs to be considered, as they may influence the load transfer at the implant-bone interface and thus possibly affect bone remodelling processes.


Asunto(s)
Artroplastia de Reemplazo de Cadera/instrumentación , Fémur/diagnóstico por imagen , Prótesis de Cadera , Ensayo de Materiales/métodos , Diseño de Prótesis , Fenómenos Biomecánicos , Humanos , Incidencia , Inestabilidad de la Articulación/epidemiología , Radiografía , Rango del Movimiento Articular , Torque
10.
Int Orthop ; 37(10): 1877-83, 2013 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-23955817

RESUMEN

PURPOSE: Extended bone defects of the proximal femur can be reconstructed by megaprostheses for which aseptic loosening constitutes one of the major failure modes. The basic requirement for long-term success of endoprostheses is primary stability. We therefore assessed whether sufficient primary stability can be achieved by four different megaprostheses in a standardised bone defect of the proximal femur and whether their different design leads to different fixation patterns. METHODS: Four different designs of proximal femoral replacements were implanted into 16 Sawbones® after preparing segmental bone defects (AAOS type II). Primary rotational stability was analysed by application of a cyclic torque of ±7 Nm and measuring the relative micromotions between bone and implant at different levels. The main fixation zones and differences of fixation patterns of the stem designs were determined by an analysis of variance. RESULTS: All four implants exhibited micromotions below 150 µm, indicating adequate primary stability. Lowest micromotions for all designs were located near the femoral isthmus. The extent of primary stability and the global implant fixation pattern differed considerably and could be related to the different design concepts. CONCLUSIONS: All megaprostheses studied provided sufficient primary stability if the fixation conditions of the femoral isthmus were intact. The design characteristics of the different stems largely determined the extent of primary stability and fixation pattern. Understanding these different fixation types could help the surgeon to choose the most suitable implant if the fixation conditions in the isthmus are compromised.


Asunto(s)
Fémur/anatomía & histología , Articulación de la Cadera/anatomía & histología , Prótesis de Cadera/clasificación , Inestabilidad de la Articulación/etiología , Diseño de Prótesis/clasificación , Falla de Prótesis/etiología , Análisis de Falla de Equipo , Fémur/cirugía , Articulación de la Cadera/cirugía , Humanos , Modelos Anatómicos , Osteotomía , Rango del Movimiento Articular
11.
J Orthop Res ; 30(8): 1285-9, 2012 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22234967

RESUMEN

We examined the rotary motions of two distinct cementless surface replacement arthroplasties of the shoulder that were implanted on humeri with central spherical bone defects of 8%, 17%, and 37% of the head volume (n = 5 each). Rotary motions were measured under a cyclic torque application and translated into relative micromotions. Implant A with a perforated central crown had micromotions < 150 µm in all bony defects and during all simulated shoulder activities. Implant B with a central tapered tri-fin pin had no micromotions > 150 µm in defects of 0% and 8% during a strenuous activity like lifting 10 kg, but did exhibit micromotion > 150 µm in 40% of the experiments in defects of 17% and 37%, which could impair bony ingrowth. Implant B displayed a significant increase in micromotions for defects of 8% and 17% (p < 0.05). Our results suggest that implant A could be used without risk in spherical head defects up to 37% of volume, even in strenuous shoulder activities immediately after its implantation. Implant B, however, is recommended in spherical defects starting from 8% and only during light shoulder activities until bony integration of the implant has occurred.


Asunto(s)
Artroplastia de Reemplazo/métodos , Cabeza Humeral/patología , Prótesis e Implantes , Articulación del Hombro/cirugía , Adulto , Anciano , Densidad Ósea , Humanos , Masculino , Persona de Mediana Edad , Diseño de Prótesis , Rango del Movimiento Articular
12.
J Orthop Res ; 29(8): 1216-21, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21671262

RESUMEN

Cementless surface replacement arthroplasties are increasingly being used to treat arthritic humeral heads. These implants are designed to provide narrow bone resection, making a later revision easier. However, no clear evidence exists as to whether their initial fixation is sufficient for bony ingrowth. The aim of our in vitro study was to characterize the relative micromotion of two resurfacing implants with essentially different bone-facing geometries. Both systems were implanted into 10 human humeral specimens and micromotion was measured under a cyclic torque application of up to ±1.75 Nm. The mean relative rotary motion resulted in a significant difference (p = 0.036), which was attributed to design differences of central stabilizers featuring both implants. A conversion of rotary motions into relative micromotions, using recently measured moments acting on these implants during daily activities of living, nullified this difference (p = 0.088). However, depending on the shoulder load case considered, a clear difference appeared (p = 0.031-0.045). In conclusion, both resurfacing implants are capable of achieving sufficient initial fixation on the humeral head and perform relative micromotions in a range considered safe for bony ingrowth. Patient-related parameters do not appear to influence the initial fixation of these implants.


Asunto(s)
Artroplastia de Reemplazo/instrumentación , Cabeza Humeral/fisiología , Rango del Movimiento Articular , Articulación del Hombro/cirugía , Actividades Cotidianas , Adulto , Anciano , Anciano de 80 o más Años , Fenómenos Biomecánicos , Humanos , Persona de Mediana Edad , Articulación del Hombro/fisiología
13.
Clin Biomech (Bristol, Avon) ; 26(3): 257-61, 2011 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-21146907

RESUMEN

BACKGROUND: Cerclage wires are widely used in revision hip surgery to reattach the lid of a femoral osteotomy. The present study compared the influence of multifilaments and monofilaments on primary stability of revision hip stems with different fixation principles. METHODS: A standardized extended proximal femoral osteotomy was performed in the anterior cortex of 6 synthetic femora. We used a high-resolution measuring device to explore spatial micromovements of a diaphyseal and a metaphyseal fixating revision stem. Both of these were implanted in 3 femora. The specimens were measured again after consecutive restabilization of osteotomies with multifilaments and monofilaments. The movement graphs generated defined relative micromovements between stems and bones and the stabilizing effect of the two wire systems compared. FINDINGS: Both multifilaments and monofilaments effected a major reduction of relative micromovements for both fixation principles. There were no differences in relative movements between the multifilament and monofilament treatments for the diaphyseal fixating stem. Yet for the metaphyseal fixating stem a significantly better restabilization was observed with multifilaments. INTERPRETATION: Both multifilaments and monofilaments can support the revision hip stem in bridging the extended proximal femoral osteotomy. Yet, which wiring system should be chosen depends on the fixation principle of the revision stem. Multifilaments seem to be advantageous when used with metaphyseal fixating stems. However, the use of multifilaments with diaphyseal fixating components should be reconsidered as this might constrict the periosteal vascularity.


Asunto(s)
Fémur/fisiopatología , Fémur/cirugía , Prótesis de Cadera , Cementos para Huesos , Cementación , Análisis de Falla de Equipo , Fricción , Humanos , Diseño de Prótesis , Resistencia a la Tracción
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...