Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Cardiol ; 57(3): 325-32, 2011 May.
Artículo en Inglés | MEDLINE | ID: mdl-21397460

RESUMEN

BACKGROUND: Syndecan-4 is a transmembrane heparan sulfate-carrying glycoprotein that mediates signal transduction pathways activated by growth factors and cell surface receptors, thereby modulating tissue regeneration, angiogenesis, and focal adhesion. The aim of the present study was to determine the clinical use of serum syndecan-4 concentration for diagnosis of heart failure. METHODS: Concentration of serum syndecan-4 and other biomarkers of heart failure was measured in 45 patients with heart failure and 21 healthy subjects. Clinical and echocardiographic parameters of cardiac function were recorded. RESULTS: Serum syndecan-4 concentration significantly increased in proportion to the decrease in ejection fraction (r=-0.599, p<0.001) and increase in the left ventricular (LV) mass index (r=0.315, p<0.05). Serum syndecan-4 concentration was significantly correlated with LV geometrical parameters (i.e. LV mass index, LV end-diastolic volume, and LV dimension), while B-type natriuretic peptide (BNP) was significantly correlated with pressure-related parameters [i.e. early transmitral flow velocity/early diastolic velocity of the mitral valve annulus (E/e'), right ventricular systolic pressure, and left atrial volume index]. Syndecan-4 concentration did not significantly correlate with plasma BNP, transforming growth factor-1, matrix metalloproteinase-2, and tenascin-C concentrations. Serum syndecan-4 concentration could predict cardiac death and re-hospitalization due to heart failure (area under curve, 0.706, p<0.05). CONCLUSION: Serum syndecan-4 concentration shows promise as a novel diagnostic and prognostic biomarker for heart failure. Since syndecan-4 correlated with LV geometrical rather than hemodynamic parameters, serum syndecan-4 may represent a biomarker of LV remodeling in the failing heart.


Asunto(s)
Biomarcadores/sangre , Insuficiencia Cardíaca/diagnóstico , Sindecano-4/sangre , Enfermedad Crónica , Muerte Súbita Cardíaca , Ecocardiografía , Femenino , Insuficiencia Cardíaca/sangre , Ventrículos Cardíacos/anatomía & histología , Humanos , Masculino , Metaloproteinasa 2 de la Matriz/sangre , Persona de Mediana Edad , Péptido Natriurético Encefálico/sangre , Readmisión del Paciente , Pronóstico , Volumen Sistólico , Tenascina/sangre , Factores de Crecimiento Transformadores/sangre , Remodelación Ventricular/fisiología
2.
Angiology ; 53(6): 741-3, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12463631

RESUMEN

Pseudoaneurysm is an unusual complication of coronary artery bypass grafting. Such aneurysms are caused by technical surgical failures, or inflammation of the sternum and mediastinum following sternotomy observed as an early or mid-term complication of cardiac surgery. This case was an 80-year-old man with a piece of artificial rubber pericardium used for complete closure of the pericardium. A large pseudoaneurysm developed in the body of the saphenous vein graft 15 years after surgery. The old rubber synthetic pericardium was severely degenerative, which induced inflammation and disrupted the saphenous vein graft.


Asunto(s)
Aneurisma Falso/etiología , Puente de Arteria Coronaria , Pericardio , Complicaciones Posoperatorias/etiología , Prótesis e Implantes/efectos adversos , Vena Safena/trasplante , Anciano , Anciano de 80 o más Años , Humanos , Masculino , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA