Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
Nat Commun ; 7: 11827, 2016 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-27282247

RESUMEN

Highly localized neuronal spikes in primate temporal cortex can encode associative memory; however, whether memory formation involves area-wide reorganization of ensemble activity, which often accompanies rhythmicity, or just local microcircuit-level plasticity, remains elusive. Using high-density electrocorticography, we capture local-field potentials spanning the monkey temporal lobes, and show that the visual pair-association (PA) memory is encoded in spatial patterns of theta activity in areas TE, 36, and, partially, in the parahippocampal cortex, but not in the entorhinal cortex. The theta patterns elicited by learned paired associates are distinct between pairs, but similar within pairs. This pattern similarity, emerging through novel PA learning, allows a machine-learning decoder trained on theta patterns elicited by a particular visual item to correctly predict the identity of those elicited by its paired associate. Our results suggest that the formation and sharing of widespread cortical theta patterns via learning-induced reorganization are involved in the mechanisms of associative memory representation.


Asunto(s)
Memoria/fisiología , Percepción Espacial/fisiología , Lóbulo Temporal/fisiología , Ritmo Teta/fisiología , Potenciales de Acción/fisiología , Animales , Electrocorticografía , Electrodos , Femenino , Primates , Análisis y Desempeño de Tareas
2.
J Turbomach ; 136(6): 0610211-6102111, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-25278646

RESUMEN

This study deals with the experimental and numerical studies of the effect of flow control devices (FCDs) on the film cooling performance of a circular cooling hole on a flat plate. Two types of FCDs with different heights are examined in this study, where each of them is mounted to the flat plate upstream of the cooling hole by changing its lateral position with respect to the hole centerline. In order to measure the film effectiveness as well as heat transfer downstream of the cooling hole with upstream FCD, a transient method using a high-resolution infrared camera is adopted. The velocity field downstream of the cooling hole is captured by 3D laser Doppler velocimeter (LDV). Furthermore, the aerodynamic loss associated with the cooling hole with/without FCD is measured by a total pressure probe rake. The experiments are carried out at blowing ratios ranging from 0.5 to 1.0. In addition, numerical simulations are also made to have a better understanding of the flow field. LES approach is employed to solve the flow field and visualize the vortex structure around the cooling hole with FCD. When a taller FCD is mounted to the plate, the film effectiveness tends to increase due to the vortex structure generated by the FCD. As FCD is laterally shifted from the centerline, the film effectiveness increases, while the lift-off of cooling air is also promoted when FCD is put on the center line.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA