Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Acad Radiol ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38641450

RESUMEN

RATIONALE AND OBJECTIVES: To evaluate and compare the effectiveness of contrast media subtraction and kidney stone detection between a virtual non-iodine reconstruction algorithm (VNI; PureCalcium) and a virtual non-contrast (VNC) algorithm in excretory phase photon-counting detector computed tomography (PCD-CT), using a 3D printed kidney phantom under various tube voltages and radiation doses. MATERIALS AND METHODS: A 3D-printed kidney phantom, holding Calcium Oxalate (CaOx) and uric acid stones within contrast-enhanced calyces, was created. The calyx density mirrored the average density observed in 200 excretory phase patients (916 HU at 110 kV). Imaging was conducted on a clinical dual-source PCD-CT at 120 kV and 140 kV, with radiation doses set at 5, 10, and 15 mGy. VNI and VNC algorithms were applied. Two blinded readers evaluated the image quality, along with the degree of contrast media and kidney stone subtraction, using visual scales. Krippendorff's alpha was calculated to determine inter-reader agreement, and the Chi-squared test was employed for comparing ordinal data. RESULTS: Reader 2 rated overall image quality higher for VNI than VNC (4.90 vs. 4.00; P < .05), while Reader 1 found no significant difference (4.96 vs. 5.00; P > .05). Substantial agreement was observed between readers for contrast media subtraction in both VNC and VNI (Krippendorff's alpha range: 0.628-0.748). Incomplete contrast media subtraction occurred more frequently with VNI for both readers (Reader 1: 29% vs. 15%; P < .05; Reader 2: 24% vs. 20%; P > .05). Uric acid and smaller stones (<5 mm) were more likely to be subtracted than CaOx and larger stones in both VNC and VNI. Overall, a higher rate of stone subtraction was noted with VNI compared to VNC (Reader 1: 22% vs. 16%; Reader 2: 25% vs. 10%; P < .05). Neither radiation dose nor tube voltage significantly influenced stone subtraction (P > .05). CONCLUSION: VNC demonstrated greater accuracy than VNI for contrast media subtraction and kidney stone visibility. Radiation dose and tube voltage had no significant impact. Nonetheless, both algorithms still exhibited frequent incomplete contrast media subtraction and partial kidney stone subtraction.

2.
Eur Radiol ; 2023 Dec 26.
Artículo en Inglés | MEDLINE | ID: mdl-38147170

RESUMEN

OBJECTIVES: Cytotoxic lesions of the corpus callosum (CLOCC) are a common magnetic resonance imaging (MRI) finding associated with various systemic diseases including COVID-19. Although an increasing number of such cases is reported in the literature, there is a lack of systematic evidence summarizing the etiology and neuroimaging findings of these lesions. Thus, the aim of this systematic review was to synthesize the applied nomenclature, neuroimaging and clinical features, and differential diagnoses as well as associated disease entities of CLOCC. MATERIALS AND METHODS: A comprehensive literature search in three biomedical databases identified 441 references, out of which 324 were eligible for a narrative summary including a total of 1353 patients. RESULTS: Our PRISMA-conform systematic review identifies a broad panel of disease entities which are associated with CLOCC, among them toxic/drug-treatment-associated, infectious (viral, bacterial), vascular, metabolic, traumatic, and neoplastic entities in both adult and pediatric individuals. On MRI, CLOCC show typical high T2 signal, low T1 signal, restricted diffusion, and lack of contrast enhancement. The majority of the lesions were reversible within the follow-up period (median follow-up 3 weeks). Interestingly, even though CLOCC were mostly associated with symptoms of the underlying disease, in exceptional cases, CLOCC were associated with callosal neurological symptoms. Of note, employed nomenclature for CLOCC was highly inconsistent. CONCLUSIONS: Our study provides high-level evidence for clinical and imaging features of CLOCC as well as associated disease entities. CLINICAL RELEVANCE STATEMENT: Our study provides high-level evidence on MRI features of CLOCC as well as a comprehensive list of disease entities potentially associated with CLOCC. Together, this will facilitate rigorous diagnostic workup of suspected CLOCC cases. KEY POINTS: • Cytotoxic lesions of the corpus callosum (CLOCC) are a frequent MRI feature associated with various systemic diseases. • Cytotoxic lesions of the corpus callosum show a highly homogenous MRI presentation and temporal dynamics. • This comprehensive overview will benefit (neuro)radiologists during diagnostic workup.

3.
Invest Radiol ; 58(11): 816-821, 2023 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-37358359

RESUMEN

OBJECTIVES: The aim of this study was to compare image quality and endoleak detection after endovascular abdominal aortic aneurysm repair between a triphasic computed tomography (CT) with true noncontrast (TNC) and a biphasic CT with virtual noniodine (VNI) images on photon-counting detector CT (PCD-CT). MATERIALS AND METHODS: Adult patients after endovascular abdominal aortic aneurysm repair who received a triphasic examination (TNC, arterial, venous phase) on a PCD-CT between August 2021 and July 2022 were retrospectively included. Endoleak detection was evaluated by 2 blinded radiologists on 2 different readout sets (triphasic CT with TNC-arterial-venous vs biphasic CT with VNI-arterial-venous). Virtual noniodine images were reconstructed from the venous phase. The radiologic report with additional confirmation by an expert reader served as reference standard for endoleak presence. Sensitivity, specificity, and interreader agreement (Krippendorf α) were calculated. Image noise was assessed subjectively in patients using a 5-point scale and objectively calculating the noise power spectrum in a phantom. RESULTS: One hundred ten patients (7 women; age, 76 ± 8 years) with 41 endoleaks were included. Endoleak detection was comparable between both readout sets with a sensitivity and specificity of 0.95/0.84 (TNC) versus 0.95/0.86 (VNI) for reader 1 and 0.88/0.98 (TNC) versus 0.88/0.94 (VNI) for reader 2. Interreader agreement for endoleak detection was substantial (TNC: 0.716, VNI: 0.756). Subjective image noise was comparable between TNC and VNI (4; IQR [4, 5] vs 4; IQR [4, 5], P = 0.44). In the phantom, noise power spectrum peak spatial frequency was similar between TNC and VNI (both f peak = 0.16 mm -1 ). Objective image noise was higher in TNC (12.7 HU) as compared with VNI (11.5 HU). CONCLUSIONS: Endoleak detection and image quality were comparable using VNI images in biphasic CT as compared with TNC images in triphasic CT offering the possibility to reduce scan phases and radiation exposure.


Asunto(s)
Aneurisma de la Aorta Abdominal , Endofuga , Adulto , Humanos , Femenino , Anciano , Anciano de 80 o más Años , Endofuga/diagnóstico por imagen , Angiografía por Tomografía Computarizada/métodos , Reparación Endovascular de Aneurismas , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía
4.
Clin Neuroradiol ; 33(3): 747-754, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36862231

RESUMEN

OBJECTIVE: To assess if a new dual-energy computed tomography (DECT) technique enables an improved visualization of ischemic brain tissue after mechanical thrombectomy in acute stroke patients. MATERIAL AND METHODS: The DECT head scans with a new sequential technique (TwinSpiral DECT) were performed in 41 patients with ischemic stroke after endovascular thrombectomy and were retrospectively included. Standard mixed and virtual non-contrast (VNC) images were reconstructed. Infarct visibility and image noise were assessed qualitatively by two readers using a 4-point Likert scale. Quantitative Hounsfield units (HU) were used to assess density differences of ischemic brain tissue versus healthy tissue on the non-affected contralateral hemisphere. RESULTS: Infarct visibility was significantly better in VNC compared to mixed images for both readers R1 (VNC: median 1 (range 1-3), mixed: median 2 (range 1-4), p < 0.05) and R2 (VNC: median 2 (range 1-3), mixed: 2 (range 1-4), p < 0.05). Qualitative image noise was significantly higher in VNC compared to mixed images for both readers R1 (VNC: median 3, mixed: 2) and R2 (VNC: median 2, mixed: 1, p < 0.05, each). Mean HU were significantly different between the infarcted tissue and the reference healthy brain tissue on the contralateral hemisphere in VNC (infarct 24 ± 3) and mixed images (infarct 33 ± 5, p < 0.05, each). The mean HU difference between ischemia and reference in VNC images (mean 8 ± 3) was significantly higher (p < 0.05) compared to the mean HU difference in mixed images (mean 5 ± 4). CONCLUSION: TwinSpiral DECT allows an improved qualitative and quantitative visualization of ischemic brain tissue in ischemic stroke patients after endovascular treatment.


Asunto(s)
Accidente Cerebrovascular Isquémico , Accidente Cerebrovascular , Humanos , Tomografía Computarizada por Rayos X/métodos , Estudios Retrospectivos , Accidente Cerebrovascular/diagnóstico por imagen , Accidente Cerebrovascular/cirugía , Isquemia , Infarto , Trombectomía
5.
Diagn Interv Imaging ; 104(2): 84-90, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36216734

RESUMEN

PURPOSE: The purpose of this study was to evaluate the impact of virtual monoenergetic image (VMI) energies and iodine maps on the diagnosis of pleural empyema with photon counting detector computed tomography (PCD-CT). MATERIALS AND METHODS: In this IRB-approved retrospective study, consecutive patients with non-infectious pleural effusion or histopathology-proven empyema were included. PCD-CT examinations were performed on a dual-source PCD-CT in the multi-energy (QuantumPlus) mode at 120 kV with weight-adjusted intravenous contrast-agent. VMIs from 40-70 keV obtained in 10 keV intervals and an iodine map was reconstructed for each scan. CT attenuation was measured in the aorta, the pleura and the peripleural fat (between autochthonous dorsal muscles and dorsal ribs). Contrast-to-noise (CNR) and signal-to-noise (SNR) ratios were calculated. Two blinded radiologists evaluated if empyema was present (yes/no), and rated diagnostic confidence (1 to 4; not confident to fully confident, respectively) with and without using the iodine map. Sensitivity, specificity and diagnostic confidence were estimated. Interobserver agreement was estimated using an unweighted Cohen kappa test. A one-way ANOVA was used to compare variables. Differences in sensitivity and specificity between the different levels of energy were searched using McNemar test. RESULTS: Sixty patients (median age, 60 years; 26 women) were included. A strong negative correlation was found between image noise and VMI energies (r = -0.98; P = 0.001) and CNR increased with lower VMI energies (r = -0.98; P = 0.002). Diagnostic accuracy (96%; 95% CI: 82-100) as well as diagnostic confidence (3.4 ± 0.75 [SD]) were highest at 40 keV. Diagnostic accuracy and confidence at higher VMI energies improved with the addition of iodine maps (P ≤0.001). Overall, no difference in CT attenuation of peripleural fat between patients with empyema and those with pleural effusion was found (P = 0.07). CONCLUSION: Low VMI energies lead to a higher diagnostic accuracy and diagnostic confidence in the diagnosis of pleural empyema. Iodine maps help in diagnosing empyema only at high VMI energies.


Asunto(s)
Empiema Pleural , Yodo , Derrame Pleural , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Relación Señal-Ruido , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada por Rayos X/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Empiema Pleural/diagnóstico por imagen , Imagen Radiográfica por Emisión de Doble Fotón/métodos
6.
Front Neurol ; 13: 947347, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36110394

RESUMEN

Objectives: The lack of systematic evidence on neuroimaging findings in motor neuron diseases (MND) hampers the diagnostic utility of magnetic resonance imaging (MRI). Thus, we aimed at performing a systematic review and meta-analysis of MRI features in MND including their histopathological correlation. Methods: In a comprehensive literature search, out of 5941 unique publications, 223 records assessing brain and spinal cord MRI findings in MND were eligible for a qualitative synthesis. 21 records were included in a random effect model meta-analysis. Results: Our meta-analysis shows that both T2-hyperintensities along the corticospinal tracts (CST) and motor cortex T2*-hypointensitites, also called "motor band sign", are more prevalent in ALS patients compared to controls [OR 2.21 (95%-CI: 1.40-3.49) and 10.85 (95%-CI: 3.74-31.44), respectively]. These two imaging findings correlate to focal axonal degeneration/myelin pallor or glial iron deposition on histopathology, respectively. Additionally, certain clinical MND phenotypes such as amyotrophic lateral sclerosis (ALS) seem to present with distinct CNS atrophy patterns. Conclusions: Although CST T2-hyperintensities and the "motor band sign" are non-specific imaging features, they can be leveraged for diagnostic workup of suspected MND cases, together with certain brain atrophy patterns. Collectively, this study provides high-grade evidence for the usefulness of MRI in the diagnostic workup of suspected MND cases. Systematic review registration: https://www.crd.york.ac.uk/PROSPERO/, identifier: CRD42020182682.

8.
Eur J Radiol Open ; 9: 100421, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35494189

RESUMEN

Objectives: To assess the impact on bone depiction quality by decreasing number of radial acquisitions (RA) of a UTE MR bone imaging sequence in MRONJ. Material and methods: UTE MR bone imaging sequences using pointwise encoding time reduction with RA (PETRA) with 60'000, 30'000 and 10'000 RA were acquired in 16 patients with MRONJ and 16 healthy volunteers. Blinded readout sessions were performed by two radiologists. Qualitative analysis compared the detection of osteolytic lesions and productive bony changes in the PETRA sequences of the patients with MRONJ. Quantitative analysis assessed the differences in image artifacts, contrast-to-noise ratio (CNR) and image noise. Results: Acquisition times were reduced from 315 to 165 and 65 s (60'000, 30'000, 10'000 RA, respectively), resulting in a fewer number of severe motion artifacts. Bone delineation was increasingly blurred when reducing the number of RA but without any trade-off in terms of diagnostic performance. Interreader agreement for the detection of pathognomonic osteolysis was moderate (κ = 0.538) for 60'000 RA and decreased to fair (κ = 0.227 and κ = 0.390) when comparing 30'000 and 10'000 RA, respectively. Image quality between sequences was comparable regarding CNR, image noise and artifact dimensions without significant differences (all P > 0.05). Conclusions: UTE MR bone imaging sequences with a lower number of RA provide sufficient image quality for detecting osteolytic lesions and productive bony changes in MRONJ subjects at faster acquisition times compared to the respective standard UTE MR bone imaging sequence.

9.
Radiology ; 303(2): 339-348, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35103540

RESUMEN

Background An iterative reconstruction (IR) algorithm was introduced for clinical photon-counting detector (PCD) CT. Purpose To investigate the image quality and the optimal strength level of a quantum IR algorithm (QIR; Siemens Healthcare) for virtual monoenergetic images and polychromatic images (T3D) in a phantom and in patients undergoing portal venous abdominal PCD CT. Materials and Methods In this retrospective study, noise power spectrum (NPS) was measured in a water-filled phantom. Consecutive oncologic patients who underwent portal venous abdominal PCD CT between March and April 2021 were included. Virtual monoenergetic images at 60 keV and T3D were reconstructed without QIR (QIR-off; reference standard) and with QIR at four levels (QIR 1-4; index tests). Global noise index, contrast-to-noise ratio (CNR), and voxel-wise CT attenuation differences were measured. Noise and texture, artifacts, diagnostic confidence, and overall quality were assessed qualitatively. Conspicuity of hypodense liver lesions was rated by four readers. Parametric (analyses of variance, paired t tests) and nonparametric tests (Friedman, post hoc Wilcoxon signed-rank tests) were used to compare quantitative and qualitative image quality among reconstructions. Results In the phantom, NPS showed unchanged noise texture across reconstructions with maximum spatial frequency differences of 0.01 per millimeter. Fifty patients (mean age, 59 years ± 16 [standard deviation]; 31 women) were included. Global noise index was reduced from QIR-off to QIR-4 by 45% for 60 keV and by 44% for T3D (both, P < .001). CNR of the liver improved from QIR-off to QIR-4 by 74% for 60 keV and by 69% for T3D (both, P < .001). No evidence of difference was found in mean attenuation of fat and liver (P = .79-.84) and on a voxel-wise basis among reconstructions. Qualitatively, QIR-4 outperformed all reconstructions in every category for 60 keV and T3D (P value range, <.001 to .01). All four readers rated QIR-4 superior to other strengths for lesion conspicuity (P value range, <.001 to .04). Conclusion In portal venous abdominal photon-counting detector CT, an iterative reconstruction algorithm (QIR; Siemens Healthcare) at high strength levels improved image quality by reducing noise and improving contrast-to-noise ratio and lesion conspicuity without compromising image texture or CT attenuation values. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Sinitsyn in this issue.


Asunto(s)
Interpretación de Imagen Radiográfica Asistida por Computador , Tomografía Computarizada por Rayos X , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Estudios Retrospectivos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos
10.
Quant Imaging Med Surg ; 11(9): 4149-4161, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34476195

RESUMEN

BACKGROUND: The purpose of this study was threefold: (I) to study the correlation of speed-of-sound (SoS) and shear-wave-speed (SWS) ultrasound (US) in the gastrocnemius muscle, (II) to use reproducible tissue compression to characterize tissue nonlinearity effects, and (III) to compare the potential of SoS and SWS for tissue composition assessment. METHODS: Twenty gastrocnemius muscles of 10 healthy young subjects (age range, 23-34 years, two females and eight males) were prospectively examined with both clinical SWS (GE Logiq E9, in m/s) and a prototype system that measures SoS (in m/s). A reflector was positioned opposite the US probe as a timing reference for SoS, with the muscle in between. Reproducible tissue compression was applied by reducing probe-reflector distance in 5 mm steps. The Ogden hyperelastic model and the acoustoelastic theory were used to characterize SoS and SWS variations with tissue compression and extract novel metrics related to tissue nonlinearity. The body fat percentage (BF%) of the subjects was estimated using bioelectrical impedance analysis. RESULTS: A weak negative correlation was observed between SWS and SoS (r=-0.28, P=0.002). SWS showed an increasing trend with increasing tissue compression (P=0.10) while SoS values decayed nonlinearly (P<0.001). The acoustoelastic modeling showed a weak correlation for SWS (r=-0.36, P<0.001) but a very strong correlation for SoS (r=0.86, P<0.001), which was used to extract the SoS acoustoelastic parameter. SWS showed higher variability between both calves [intraclass correlation coefficient (ICC) =0.62, P=0.08] than SoS (ICC =0.91, P<0.001). Correlations with BF% were strong and positive for SWS (r=0.60, P<0.001), moderate and negative for SoS (r=-0.43, P=0.05), and moderate positive for SoS acoustoelastic parameter (r=0.48, P=0.03). CONCLUSIONS: SWS and SoS provide independent information about tissue elastic properties. SWS correlated stronger with BF% than SoS, but measurements were less reliable. SoS enabled the extraction of novel metrics related to tissue nonlinearity with potential complementary information.

11.
Acad Radiol ; 28(6): 783-789, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32418783

RESUMEN

RATIONALE AND OBJECTIVES: To quantify the contribution of lesion location and patient positioning, dual-energy approach, patient size, and radiation dose to the error of dual-energy CT-based iodine quantification (DECT-IQ) in liver tumors. MATERIALS AND METHODS: A phantom with four liver lesions (diameter 15 mm; iodine concentration 0-5 mgI/mL) and two sizes was used. One lesion emulated a subdiaphragmatic lesion. Both sizes were imaged in dual-energy mode on (1) a dual-source DECT (DS-DE) at 100/Sn150 kV and (2) a single-source split-filter DECT (SF-DE) at AuSn120 kV at two radiation doses (8 and 12 mGy). Scans were performed at seven different vertical table positions (from -6 to + 6 cm from the gantry isocenter). Iodine concentration was repeatedly measured and absolute errors (errorabs) were calculated. Errors were compared using robust repeated-measures ANOVAs with post-hoc comparisons. A linear mixed effect model was used to determine the factors influencing the error of DECT-IQ. RESULTS: The linear mixed effect models showed that errors were significantly influenced by DECT approach, phantom size, and lesion location (all p < 0.001). The impact of lesion location on the error was stronger in SF-DE compared to DS-DE. Radiation dose did not significantly influence error (p = 0.22). When averaged across all setups, errorabs was significantly higher for SF-DE (2.08 ± 1.92 mgI/mL) compared to DS-DE (0.37 ± 0.29 mgI/mL) (all p < 0.001). Artefacts were found in the subdiaphragmatic lesion for SF-DE with significantly increased errorabs compared to DS-DE (p < 0.001). Errorabs was significantly higher in the large compared to the medium phantom for DS-DE (0.30 ± 0.23 mgI/mL vs. 0.43 ± 0.33 mgI/mL) and SF-DE (1.68 ± 1.99 vs. 2.36 ± 1.81 mgI/mL) (p < 0.001). CONCLUSION: The dual-energy approach, patient size, and lesion location modified by patient position significantly impacted DECT-IQ in simulated liver tumors.


Asunto(s)
Yodo , Neoplasias Hepáticas , Imagen Radiográfica por Emisión de Doble Fotón , Humanos , Neoplasias Hepáticas/diagnóstico por imagen , Fantasmas de Imagen , Cintigrafía , Tomografía Computarizada por Rayos X
12.
Abdom Radiol (NY) ; 46(5): 2079-2089, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33159558

RESUMEN

PURPOSE: To compare noise texture and accuracy to differentiate uric acid from non-uric acid urinary stones among four different single-source and dual-source DECT approaches in an ex vivo phantom study. METHODS: Thirty-two urinary stones embedded in gelatin were mounted on a Styrofoam disk and placed into a water-filled phantom. The phantom was imaged using four different DECT approaches: (A) dual-source DECT (DS-DE); (B) 1st generation split-filter single-source DECT (SF1-TB); (C) 2nd generation split-filter single-source DECT (SF2-TB) and (D) 2nd generation split-filter single-source DECT using serial acquisitions (SF2-TS). Two different radiation doses (3 mGy and 6 mGy) were used. Noise texture was compared by assessing the average spatial frequency (fav) of the normalized noise power spectrum (nNPS). ROC curves for stone classification were computed and the accuracy for different dual-energy ratio cutoffs was derived. RESULTS: NNPS demonstrated comparable noise texture among A, C, and D (fav-range 0.18-0.19) but finer noise texture for B (fav = 0.27). Stone classification showed an accuracy of 96.9%, 96.9%, 93.8%, 93.8% for A, B, C, D for low-dose, respectively, and 100%, 96.9%, 96.9%, 100% for routine dose. The vendor-specified cutoff for the dual-energy ratio was optimal except for the low-dose scan in D for which the accuracy was improved from 93.8 to 100% using an optimized cutoff. CONCLUSION: Accuracy to differentiate uric acid from non-uric acid stones was high among four single-source and dual-source DECT approaches for low- and routine dose DECT scans. Noise texture differed only slightly for the first-generation split-filter approach.


Asunto(s)
Cálculos Urinarios , Urolitiasis , Humanos , Fantasmas de Imagen , Tomografía Computarizada por Rayos X , Ácido Úrico , Cálculos Urinarios/diagnóstico por imagen
13.
Eur Radiol ; 30(10): 5272-5280, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-32385650

RESUMEN

OBJECTIVES: To compare speed of sound (SoS) ultrasound (US) of the calves with Dixon magnetic resonance imaging (MRI) for fat content quantification. MATERIALS AND METHODS: The study was approved by the local ethics committee. Fifty calf muscles of 35 women (age range 22-81 years) prospectively underwent an US and subsequent MRI (Dixon sequence) examination as well as body weight and impedance fat measurements. SoS (in m/s) was calculated positioning a reflector on the opposite side of a conventional US machine probe with the calf in between. Fiducial nitroglycerin markers were placed on the calf at the reflector and US probe end positions for later registration of the US sonification volumetric section. An automatic segmentation algorithm separated MRI adipose tissue, muscle and bone regions. MRI fat fraction of the entire leg slice (total) and intramuscular and adipose tissue fat fraction were calculated and correlation analysis and correlation coefficient comparison were performed. RESULTS: Median SoS demonstrated a very strong (r = - 0.83 (95% CI - 0.90; - 0.72); p < 0.001) correlation with MRI total fat fraction, a strong (r = - 0.61 (95% CI - 0.76; - 0.40); p < 0.001) correlation with MRI adipose tissue fat fraction and a moderate (r = - 0.54 (95% CI - 0.71; - 0.31); p < 0.001) correlation with MRI intramuscular fat fraction. Impedance body fat percentage correlated strongly with SoS (r = - 0.72 (95% CI - 0.85; - 0.51); p < 0.001) and MRI total fat fraction (r = 0.61 (95% CI 0.34; 0.78); p < 0.001). For electrical impedance, significantly lower correlations (p = 0.033) were found for MRI total fat fraction compared with SoS. CONCLUSIONS: Correlations of SoS with Dixon MRI fat fraction measurements were very strong to moderate. KEY POINTS: • Correlations of speed of sound with Dixon MRI fat fraction measurements of the same body location were very strong to moderate. • Speed of sound measurements showed a high repeatability. • Speed of sound provides a sufficient discrimination range for fat fraction estimates.


Asunto(s)
Tejido Adiposo/diagnóstico por imagen , Algoritmos , Imagen por Resonancia Magnética/métodos , Músculo Esquelético/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Animales , Bovinos , Femenino , Humanos , Extremidad Inferior , Masculino , Persona de Mediana Edad , Protones , Adulto Joven
14.
Obes Surg ; 28(9): 2760-2766, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29679338

RESUMEN

BACKGROUND: Early intra-abdominal infections (IAI) compromise short-term outcomes in bariatric surgery. The timely detection of IAI is challenging but essential to prevent major sequelae of such complications. C-reactive protein (CRP) is a reliable marker for detecting IAI after colorectal surgery. In bariatric surgery, data on CRP as a marker for IAI are limited, particularly for postoperative day one (POD1). OBJECTIVE: The objective of this study was to assess CRP on POD1 as a predictor for early IAI (within 7 days following surgery) in patients after laparoscopic sleeve gastrectomy (LSG) and Roux-en-Y gastric bypass (LRYGB). METHODS: Patients with bariatric surgery between 08/2010 and 06/2017 were included. The predictive capacity of CRP for early IAI was determined using a receiver operating characteristics (ROC) analysis. RESULTS: In 523 patients (68.5% female, LSG = 358, LRYGB = 165), 16 (3%) early IAI were observed. ROC analysis revealed a significant predictive capacity of POD1 CRP for early IAI, with a sensitivity and a specificity of 81.2 and 94.3%, respectively, at a CRP cut-off value of 70 mg/L. In patients with confirmed early IAI, 81.3% had a CRP level ≥ 70 mg/L (LSG 85.7%, LRYGB 77.8%). The negative predictive value for a CRP level < 70 mg/L was 99.4% overall and was 100 and 98% for LSG and LRYGB, respectively. CONCLUSION: In patients with a CRP level < 70 mg/L on POD1, early IAI can be excluded with high accuracy in bariatric patients. Thus, early postoperative CRP may be used to assess the risk of early IAI in enhanced recovery programs.


Asunto(s)
Cirugía Bariátrica/efectos adversos , Proteína C-Reactiva/análisis , Infecciones Intraabdominales , Obesidad Mórbida/cirugía , Complicaciones Posoperatorias , Femenino , Humanos , Infecciones Intraabdominales/sangre , Infecciones Intraabdominales/epidemiología , Masculino , Complicaciones Posoperatorias/sangre , Complicaciones Posoperatorias/epidemiología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...