Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-24910297

RESUMEN

The enantiomeric separation of a series of racemic functionalized ethano-bridged Tröger base compounds was examined by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using HPLC and CE the entire set of 14 derivatives was separated by chiral stationary phases (CSPs) and chiral additives composed of cyclodextrin (native and derivatized) and cyclofructan (derivatized). Baseline separations (Rs ≥ 1.5) in HPLC were achieved for 13 of the 14 compounds with resolution values as high as 5.0. CE produced 2 baseline separations. The separations on the cyclodextrin CSPs showed optimum results in the reversed phase mode, and the LARIHC cyclofructan CSPs separations showed optimum results in the normal phase mode. HPLC separation data of the compounds was analyzed using principal component analysis (PCA). The PCA biplot analysis showed that retention is governed by the size of the R1 substituent in the case of derivatized cyclofructan and cyclodextrin CSPs, and enantiomeric resolution closely correlated with the size of the R2 group in the case of non-derivatized γ-cyclodextrin CSP. It is clearly shown that chromatographic retention is necessary but not sufficient for the enantiomeric separations of these compounds.

2.
Artículo en Inglés | MEDLINE | ID: mdl-24631813

RESUMEN

The enantiomeric separation of a series of racemic functionalized ethano-bridged Tröger base compounds was examined by high performance liquid chromatography (HPLC) and capillary electrophoresis (CE). Using HPLC and CE the entire set of 14 derivatives was separated by chiral stationary phases (CSPs) and chiral additives composed of cyclodextrin (native and derivatized) and cyclofructan (derivatized). Baseline separations (Rs≥1.5) in HPLC were achieved for 13 of the 14 compounds with resolution values as high as 5.0. CE produced 2 baseline separations. The separations on the cyclodextrin CSPs showed optimum results in the reversed phase mode, and the LARIHC™ cyclofructan CSPs separations showed optimum results in the normal phase mode. HPLC separation data of the compounds was analyzed using principal component analysis (PCA). The PCA biplot analysis showed that retention is governed by the size of the R1 substituent in the case of derivatized cyclofructan and cyclodextrin CSPs, and enantiomeric resolution closely correlated with the size of the R2 group in the case of non-derivatized γ-cyclodextrin CSP. It is clearly shown that chromatographic retention is necessary but not sufficient for the enantiomeric separations of these compounds.


Asunto(s)
Azocinas/química , Azocinas/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Ciclodextrinas/química , Electroforesis Capilar/métodos , Fructanos/química , Azocinas/análisis , Análisis de Componente Principal , Estereoisomerismo
3.
J Chromatogr A ; 1305: 94-101, 2013 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-23906806

RESUMEN

Isochromene derivatives are very important precursors in the natural products industry. Hence the enantiomeric separations of chiral isochromenes are important in the pharmaceutical industry and for organic asymmetric synthesis. Here we report enantiomeric separations of 21 different chiral isochromene derivatives, which were synthesized using alkynylbenzaldehyde cyclization catalyzed by chiral gold(I) acyclic diaminocarbene complexes. All separations were achieved by high-performance liquid chromatography with cyclodextrin based (Cyclobond) chiral stationary phases. Retention data of 21 chiral compounds and 14 other previously separated isochromene derivatives were analyzed using principal component analysis. The effect of the structure of the substituents on the isochromene ring on enantiomeric resolution as well as the other separation properties was analyzed in detail. Using principal component analysis it can be shown that the structural features that contribute to increased retention are different from those that enhance enantiomeric resolution. In addition, principal component analysis is useful for eliminating redundant factors from consideration when analyzing the effect of various chromatographic parameters. It was found that the chiral recognition mechanism is different for the larger γ-cyclodextrin as compared to the smaller ß-cyclodextrin derivatives. Finally this specific system of chiral analytes and cyclodextrin based chiral selectors provides an effective format to examine the application of principal component analysis to enantiomeric separations using basic retention data and structural features.


Asunto(s)
Benzopiranos/aislamiento & purificación , Cromatografía Líquida de Alta Presión/métodos , Ciclodextrinas/química , Análisis de Componente Principal , Estereoisomerismo
4.
Anal Bioanal Chem ; 401(9): 2669-78, 2011 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21960255

RESUMEN

A new analytical detector based on a liquid drop resistor-capacitor (RC) filter is described, in which transformed gain vs. frequency curves are used to analyze compounds. This detector can be used to detect either charged or neutral species (that are dielectrically different) which are dissolved in a liquid (e.g., water, alcohol, solvent mixtures, etc.). This device was fabricated by modifying an electrowetting on dielectric (EWOD)-based experimental setup. When a liquid drop is placed on a dielectric surface, the system acts as a RC filter. At a given frequency, gain is a function of conductivity, surface tension, dielectric constant, double-layer thickness of the solid-liquid drop interface, as well as the applied voltage. Since different liquids and solutions have different physical properties, each liquid/solution has a unique curve (peak) in gain vs. frequency plot. This is the basic principle behind the detector. Different amounts of zinc chloride dissolved in water, benzalkonium chloride in water, 1-methylimidazole in water, cetyltrimethyl-ammonium chloride (CTAC) in water, and CTAC dissolved in ethylene glycol solutions were tested with the detector as proof of principle. The device can be used as a stand-alone detector or can easily be coupled with droplet based microfluidic lab-on-a-chip systems such as EWOD-based microfluidic chips.

5.
Anal Chem ; 83(5): 1658-64, 2011 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-21294515

RESUMEN

This paper demonstrates a novel drop-to-drop liquid-liquid micro-extraction (DTD-LLME) device, which is based on an electrowetting on dielectric (EWOD) digital microfluidic chip. Droplets of two immiscible liquids, one of which is an ionic liquid, are formed in nanoliter volumes, driven along electrodes, merged and mixed for extraction, and finally separated upon the completion of the extraction process. All the steps are carried out on a microfluidic chip using combined electrowetting and dielectrophoretic forces, which act on the droplet upon the application of electric potential. Specially, the phase separation of two immiscible nanoliter-scale liquid drops was achieved for the first time on an EWOD digital microfluidic chip. To study the on-chip extraction kinetics, an image-based concentration measurement technique with suitable color parameters was studied and compared with the typical UV absorption based technique. Finally, the effect of applied ac voltage frequency on the extraction kinetics was studied. The observations on DTD-LLME, particularly phase separation, are discussed. The image-based method was found to be applicable for precise concentration measurements with the right choice of the color parameter. Results from experiments on finding the frequency dependence on extraction kinetics demonstrate that the application of higher frequencies can be a factor in accelerating the extraction on the proposed microextraction device.

6.
Analyst ; 136(4): 787-800, 2011 Feb 21.
Artículo en Inglés | MEDLINE | ID: mdl-21140011

RESUMEN

The two best aromatic-functionalized cyclofructan chiral stationary phases, R-naphthylethyl-carbamate cyclofructan 6 (RN-CF6) and dimethylphenyl-carbamate cyclofructan 7 (DMP-CF7), were synthesized and evaluated by injecting various classes of chiral analytes. They provided enantioselectivity toward a broad range of compounds, including chiral acids, amines, metal complexes, and neutral compounds. It is interesting that they exhibited complementary selectivities and the combination of two columns provided enantiomeric separations for 43% of the test analytes. These extensive chromatographic results provided useful information about method development of specific analytes, and also gave some insight as to the enantioseparation mechanism.

7.
Anal Chem ; 82(8): 3146-54, 2010 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-20349933

RESUMEN

This paper presents a study of electrowetting of ionic liquids (ILs) under AC voltages, where nine different ILs (including mono-, di-, and tricationic varieties) with three different AC frequencies (60 Hz, 1 kHz, 10 kHz) were experimentally investigated. The main foci of this study are (i) an investigation of AC frequency dependence on the electrowetting of ILs; (ii) obtaining theoretical relationships between the relevant factors that explain the experimentally achieved frequency dependence; and (iii) a systematic comparison of electrowetting of ILs using AC vs DC voltage fields. The frequency of the AC voltage was found to be directly related to the apparent contact angle change (Deltatheta) of the ILs. This relationship was further analyzed and explained theoretically. The electrowetting properties of ILs under AC voltages were compared to that under DC voltages. All tested ILs showed greater apparent contact angle changes with AC voltage conditions than with DC voltage conditions. The effect of structure and charge density also was examined. Electrowetting reversibility under AC voltage conditions was studied for few ILs. Finally, the physical properties and AC electrowetting properties of ILs were measured and tabulated.

8.
Anal Chem ; 80(20): 7690-8, 2008 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-18816069

RESUMEN

Water or aqueous electrolytes are the dominant components in electrowetting on dielectric (EWOD)-based microfluidic devices. Low thermal stability, evaporation, and a propensity to facilitate corrosion of the metal parts of integrated circuits or electronics are drawbacks of aqueous solutions. The alternative use of ionic liquids (ILs) as electrowetting agents in EWOD-based applications or devices could overcome these limitations. Efficient EWOD devices could be developed using task-specific ILs. In this regard, a fundamental study on the electrowetting properties of ILs is essential. Therefore electrowetting properties of 19 different ionic liquids, including mono-, di-, and tricationic, plus mono- and dianionic ILs were examined. All tested ILs showed electrowetting of various magnitudes on an amorphous flouropolymer layer. The effects of IL structure, functionality, and charge density on the electrowetting properties were studied. The enhanced stability of ILs in electrowetting on dielectric at higher voltages was studied in comparison with water. Deviations from classical electrowetting theory were confirmed. The physical properties of ILs and their electrowetting properties were tabulated. These data can be used as references to engineer task-specific electrowetting agents (ILs) for future electrowetting-based applications.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...