Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 46
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
JRSM Cardiovasc Dis ; 13: 20480040231225384, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38314325

RESUMEN

Introduction: Photoplethysmogram signals from wearable devices typically measure heart rate and blood oxygen saturation, but contain a wealth of additional information about the cardiovascular system. In this study, we compared two signal-processing techniques: fiducial point analysis and Symmetric Projection Attractor Reconstruction, on their ability to extract new cardiovascular information from a photoplethysmogram signal. The aim was to identify fiducial point analysis and Symmetric Projection Attractor Reconstruction indices that could classify photoplethysmogram signals, according to age, sex and physical activity. Methods: Three datasets were used: an in-silico dataset of simulated photoplethysmogram waves for healthy male participants (25-75 years old); an in-vivo dataset containing 10-min photoplethysmogram recordings from 57 healthy subjects at rest (18-39 or > 70 years old; 53% female); and an in-vivo dataset containing photoplethysmogram recordings collected for 4 weeks from a single subject, in daily life. The best-performing indices from the in-silico study (5/48 fiducial point analysis and 6/49 Symmetric Projection Attractor Reconstruction) were applied to the in-vivo datasets. Results: Key fiducial point analysis and Symmetric Projection Attractor Reconstruction indices, which showed the greatest differences between groups, were found to be consistent across datasets. These indices were related to systolic augmentation, diastolic peak positioning and prominence, and waveform variability. Both fiducial point analysis and Symmetric Projection Attractor Reconstruction techniques provided indices that supported the classification of age and physical activity, but not sex. Conclusions: Both fiducial point analysis and Symmetric Projection Attractor Reconstruction techniques demonstrated utility in identifying cardiovascular differences between individuals and within an individual over time. Future research should investigate the potential utility of these techniques for extracting information on fitness and disease, to support healthcare-decision making.

2.
Am J Physiol Heart Circ Physiol ; 325(6): H1290-H1303, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37737734

RESUMEN

Vascular aging (VA) involves structural and functional changes in blood vessels that contribute to cardiovascular disease. Several noninvasive pulse wave (PW) indices have been proposed to assess the arterial stiffness component of VA in the clinic and daily life. This study investigated 19 of these indices, identified in recent review articles on VA, by using a database comprising 3,837 virtual healthy subjects aged 25-75 yr, each with unique PW signals simulated under various levels of artificial noise to mimic real measurement errors. For each subject, VA indices were calculated from filtered PW signals and compared with the precise theoretical value of aortic Young's modulus (EAo). In silico PW indices showed age-related changes that align with in vivo population studies. The cardio-ankle vascular index (CAVI) and all pulse wave velocity (PWV) indices showed strong linear correlations with EAo (Pearson's rp > 0.95). Carotid distensibility showed a strong negative nonlinear correlation (Spearman's rs < -0.99). CAVI and distensibility exhibited greater resilience to noise compared with PWV indices. Blood pressure-related indices and photoplethysmography (PPG)-based indices showed weaker correlations with EAo (rp and rs < 0.89, |rp| and |rs| < 0.84, respectively). Overall, blood pressure-related indices were confounded by more cardiovascular properties (heart rate, stroke volume, duration of systole, large artery diameter, and/or peripheral vascular resistance) compared with other studied indices, and PPG-based indices were most affected by noise. In conclusion, carotid-femoral PWV, CAVI and carotid distensibility emerged as the superior clinical VA indicators, with a strong EAo correlation and noise resilience. PPG-based indices showed potential for daily VA monitoring under minimized noise disturbances.NEW & NOTEWORTHY For the first time, 19 noninvasive pulse wave indices for assessing vascular aging were examined together in a single database of nearly 4,000 subjects aged 25-75 yr. The dataset contained precise values of the aortic Young's modulus and other hemodynamic measures for each subject, which enabled us to test each index's ability to measure changes in aortic stiffness while accounting for confounding factors and measurement errors. The study provides freely available tools for analyzing these and additional indices.


Asunto(s)
Análisis de la Onda del Pulso , Rigidez Vascular , Humanos , Envejecimiento/fisiología , Hemodinámica , Aorta , Arterias Carótidas , Rigidez Vascular/fisiología
3.
ERJ Open Res ; 9(4)2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37650090

RESUMEN

Respiratory waveforms can be reduced to simple metrics, such as rate, but this may miss information about waveform shape and whole breathing pattern. A novel analysis method quantifying the whole waveform shape identifies AECOPD earlier. https://bit.ly/3M6uIEB.

4.
JID Innov ; 3(1): 100154, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36561914

RESUMEN

Inflammatory edema formation and polymorphonuclear leukocyte (neutrophil) accumulation are common components of cutaneous vascular inflammation, and their assessment is a powerful investigative and drug development tool but typically requires independent cohorts of animals to assess each. We have established the use of a mathematical formula to estimate the ellipsoidal-shaped volume of the edematous wheal or bleb after intradermal injections of substances in mice pretreated intravenously with Evans blue dye (which binds to plasma albumin) to act as an edema marker. Whereas previous extraction of Evans blue dye with formamide is suitable for all strains of mice, we report this quicker and more reliable assessment of edema volume in situ. This therefore allows neutrophil accumulation to be assessed from the same mouse using the myeloperoxidase assay. Importantly, we examined the influence of Evans blue dye on the spectrometry readout at the wavelength at which myeloperoxidase activity is measured. The results indicate that it is feasible to quantify edema formation and neutrophil accumulation in the same mouse skin site. Thus, we show techniques that can assess edema formation and neutrophil accumulation at the same site in the same mouse, allowing paired measurements and reducing the total use of mice by 50%.

5.
JRSM Cardiovasc Dis ; 11: 20480040221121438, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36092374

RESUMEN

Cardiovascular waveforms such as blood pressure, ECG and photoplethysmography (PPG), are routinely acquired by specialised monitoring devices. Such devices include bedside monitors, wearables and radiotelemetry which sample at very high fidelity, yet most of this numerical data is disregarded and focus tends to reside on single point averages such as the maxima, minima, amplitude, rate and intervals. Whilst, these measures are undoubtedly of value, we may be missing important information by simplifying the complex waveform signal in this way. This Special Collection showcases recent advances in the appraisal of routine signals. Ultimately, such approaches and technologies may assist in improving the accuracy and sensitivity of detecting physiological change. This, in turn, may assist with identifying efficacy or safety signals for investigational new drugs or aidpatient diagnosis and management, supporting scientific and clinical decision making.

6.
Diabetes Obes Metab ; 24(11): 2241-2252, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-35815375

RESUMEN

AIM: To establish the impact of sex, dosing route, fasting duration and acute habituation stress on glucose tolerance test (GTT) measurements used in the preclinical evaluation of potential glucose-modulating therapeutics. METHODS: Adult male and female C57Bl/6J mice, implanted with HD-XG glucose telemetry devices, were fasted for 16 hours or 6 hours following acute habituation stress due to whole cage change, cage change with retention of used bedding or no cage change prior to intraperitoneal (IP) GTTs. To evaluate protocol refinement and sex on the ability of the GTT to detect drug effects, we administered 250 mg/kg oral metformin or 10 nmol/kg IP exendin-4 using optimized protocols. RESULTS: Female mice were less sensitive to human intervention when initiating fasting. Following a 6-hour fast, retention of bedding whilst changing the cage base promotes quicker stabilization of basal blood glucose in both sexes. Prolonged fasting for 16 hours resulted in an exaggerated GTT response but induced pronounced basal hypoglycaemia. Following GTT protocol optimization the effect of exendin-4 and metformin was equivalent in both sexes, with females showing a more modest but more reproducible GTT response. CONCLUSIONS: Variations in GTT protocol have profound effects on glucose homeostasis. Protocol refinement and/or the use of females still allows for detection of drug effects, providing evidence that more severe phenotypes are not an essential prerequisite when characterizing/validating new drugs.


Asunto(s)
Glucemia , Metformina , Adulto , Animales , Exenatida , Femenino , Glucosa , Prueba de Tolerancia a la Glucosa , Humanos , Masculino , Metformina/farmacología , Ratones , Ratones Endogámicos C57BL
7.
Cardiovasc Digit Health J ; 3(2): 96-106, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35493267

RESUMEN

Background: Atrial fibrillation (AF) is a common cardiac arrhythmia in both human and equine populations. It is associated with adverse outcomes in humans and decreased athletic performance in both populations. Paroxysmal atrial fibrillation (PAF) presents with intermittent, self-terminating AF episodes, and is difficult to diagnose once sinus rhythm resumes. Objective: We aimed to detect PAF subjects from normal sinus rhythm equine electrocardiograms (ECGs) using the Symmetric Projection Attractor Reconstruction (SPAR) method to encapsulate the waveform morphology and variability as the basis of a machine learning classification. Methods: We obtained ECG signals from 139 active equine athletes (120 control, 19 with a PAF diagnosis). The SPAR method was applied to 9 short (20-second) ECG strips for each subject. An optimal SPAR feature set was determined by forward feature selection for input to a machine learning model ensemble of 3 different classifiers (k-nearest neighbors, linear support vector machine, and radial basis function kernel support vector machine). Imbalanced data were handled by upsampling the minority (PAF) class. A final subject classification was made by taking a majority vote over results from the 9 ECG strips. Results: Our final cross-validated classification for a subject gave an accuracy of 89.0%, sensitivity of 94.8%, specificity of 87.1%, and receiver operating characteristic area under the curve of 0.98, taking PAF as the positive class. Conclusion: The SPAR method and machine learning generated a final model with high sensitivity, suggesting that PAF can be discriminated from short equine ECG strips. This preliminary study indicated that SPAR analysis of human ECG could support patient monitoring, risk stratification, and clinical decision-making.

8.
Front Cardiovasc Med ; 8: 709457, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34631814

RESUMEN

Background: The electrocardiogram (ECG) is a key tool in patient management. Automated ECG analysis supports clinical decision-making, but traditional fiducial point identification discards much of the time-series data that captures the morphology of the whole waveform. Our Symmetric Projection Attractor Reconstruction (SPAR) method uses all the available data to provide a new visualization and quantification of the morphology and variability of any approximately periodic signal. We therefore applied SPAR to ECG signals to ascertain whether this more detailed investigation of ECG morphology adds clinical value. Methods: Our aim was to demonstrate the accuracy of the SPAR method in discriminating between two biologically distinct groups. As sex has been shown to influence the waveform appearance, we investigated sex differences in normal sinus rhythm ECGs. We applied the SPAR method to 9,007 10 second 12-lead ECG recordings from Physionet, which comprised; Dataset 1: 104 subjects (40% female), Dataset 2: 8,903 subjects (54% female). Results: SPAR showed clear visual differences between female and male ECGs (Dataset 1). A stacked machine learning model achieved a cross-validation sex classification accuracy of 86.3% (Dataset 2) and an unseen test accuracy of 91.3% (Dataset 1). The mid-precordial leads performed best in classification individually, but the highest overall accuracy was achieved with all 12 leads. Classification accuracy was highest for young adults and declined with older age. Conclusions: SPAR allows quantification of the morphology of the ECG without the need to identify conventional fiducial points, whilst utilizing of all the data reduces inadvertent bias. By intuitively re-visualizing signal morphology as two-dimensional images, SPAR accurately discriminated ECG sex differences in a small dataset. We extended the approach to a machine learning classification of sex for a larger dataset, and showed that the SPAR method provided a means of visualizing the similarities of subjects given the same classification. This proof-of-concept study therefore provided an implementation of SPAR using existing data and showed that subtle differences in the ECG can be amplified by the attractor. SPAR's supplementary analysis of ECG morphology may enhance conventional automated analysis in clinically important datasets, and improve patient stratification and risk management.

9.
Diabet Med ; 38(12): e14705, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34596274

RESUMEN

Mice are used extensively in preclinical diabetes research to model various aspects of blood glucose homeostasis. Careful experimental design is vital for maximising welfare and improving reproducibility of data. Alongside decisions regarding physiological characteristics of the animal cohort (e.g., sex, strain and age), experimental protocols must also be carefully considered. This includes choosing relevant end points of interest and understanding what information they can provide and what their limitations are. Details of experimental protocols must, therefore, be carefully planned during the experimental design stage, especially considering the impact of researcher interventions on preclinical end points. Indeed, in line with the 3Rs of animal research, experiments should be refined where possible to maximise welfare. The role of welfare may be particularly pertinent in preclinical diabetes research as blood glucose concentrations are directly altered by physiological stress responses. Despite the potential impact of variations in experimental protocols, there is distinct lack of standardisation and consistency throughout the literature with regards to several experimental procedures including fasting, cage changing and glucose tolerance test protocol. This review firstly highlights practical considerations with regard to the choice of end points in preclinical diabetes research and the potential for novel technologies such as continuous glucose monitoring and glucose clamping techniques to improve data resolution. The potential influence of differing experimental protocols and in vivo procedures on both welfare and experimental outcomes is then discussed with focus on standardisation, consistency and full disclosure of methods.


Asunto(s)
Investigación Biomédica/métodos , Automonitorización de la Glucosa Sanguínea/métodos , Glucemia/metabolismo , Diabetes Mellitus Experimental/diagnóstico , Diabetes Mellitus/diagnóstico , Animales , Diabetes Mellitus/sangre , Diabetes Mellitus Experimental/sangre , Prueba de Tolerancia a la Glucosa , Ratones
10.
Clin Sci (Lond) ; 134(13): 1715-1734, 2020 07 17.
Artículo en Inglés | MEDLINE | ID: mdl-32648582

RESUMEN

Sepsis is a major worldwide healthcare issue with unmet clinical need. Despite extensive animal research in this area, successful clinical translation has been largely unsuccessful. We propose one reason for this is that, sometimes, the experimental question is misdirected or unrealistic expectations are being made of the animal model. As sepsis models can lead to a rapid and substantial suffering - it is essential that we continually review experimental approaches and undertake a full harm:benefit impact assessment for each study. In some instances, this may require refinement of existing sepsis models. In other cases, it may be replacement to a different experimental system altogether, answering a mechanistic question whilst aligning with the principles of reduction, refinement and replacement (3Rs). We discuss making better use of patient data to identify potentially useful therapeutic targets which can subsequently be validated in preclinical systems. This may be achieved through greater use of construct validity models, from which mechanistic conclusions are drawn. We argue that such models could provide equally useful scientific data as face validity models, but with an improved 3Rs impact. Indeed, construct validity models may not require sepsis to be modelled, per se. We propose that approaches that could support and refine clinical translation of research findings, whilst reducing the overall welfare burden on research animals.


Asunto(s)
Modelos Animales de Enfermedad , Sepsis/patología , Investigación Biomédica Traslacional , Animales , Ensayos Clínicos como Asunto , Humanos , Sepsis/fisiopatología
11.
Exp Physiol ; 105(9): 1444-1451, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32347611

RESUMEN

NEW FINDINGS: What is the topic of this review? Symmetric Projection Attractor Reconstruction (SPAR) is a relatively new mathematical method that can extract additional information pertaining to the morphology and variability of physiological waveforms, such as arterial pulse pressure. Herein, we describe the potential utility of the method for more sensitive quantification of cardiovascular changes. What advances does it highlight? We use a simple example of a human tilt table to illustrate these concepts. SPAR can be used on any approximately periodic waveform and may add value to experimental and clinical settings, where such signals are collected routinely. ABSTRACT: Periodic physiological waveform data, such as blood pressure, pulse oximetry and ECG, are routinely sampled between 100 and 1000 Hz in preclinical research and in the clinical setting from a wide variety of implantable, bedside and wearable monitoring devices. Despite the underlying numerical waveform data being captured at such high fidelity, conventional analysis tends to reside in reporting only averages of minimum, maximum, amplitude and rate, as single point averages. Although these averages are undoubtedly of value, simplification of the data in this way means that most of the available numerical data are discarded. In turn, this may lead to subtle physiological changes being missed when investigating the cardiovascular system over time. We have developed a mathematical method (symmetric projection attractor reconstruction) that uses all the numerical data, replotting and revisualizing them in a manner that allows unique quantification of multiple changes in waveform morphology and variability. We propose that the additional quantification of these features will allow the complex behaviour of the cardiovascular system to be mapped more sensitively in different physiological and pathophysiological settings.


Asunto(s)
Presión Sanguínea , Oximetría , Procesamiento de Señales Asistido por Computador , Fenómenos Fisiológicos Cardiovasculares , Electrocardiografía , Frecuencia Cardíaca , Humanos , Modelos Teóricos
12.
J Med Chem ; 63(8): 4215-4226, 2020 04 23.
Artículo en Inglés | MEDLINE | ID: mdl-32208614

RESUMEN

Deferoxamine, deferiprone, and deferasirox are used for the treatment of systemic iron overload, although they possess limitations due to lack of oral activity, lower efficacy, and side effects. These limitations led to a search for an orally active iron chelator with an improved therapeutic index. The lower efficacy of deferiprone is due to rapid glucuronidation, leading to the formation of a nonchelating metabolite. Here, we demonstrate that the influence of metabolism can be reduced by introducing a sacrificial site for glucuronidation. A log P-guided investigation of 20 hydroxpyridinones led to the identification of CN128. The Fe(III) affinity and metal selectivity of CN128 are similar to those of deferiprone, the log P value is more lipophilic, and its iron scavenging ability is superior. Overall, CN128 was demonstrated to be safe in a range of toxicity assessments and is now in clinical trials for the treatment of ß-thalassemia after regular blood transfusion.


Asunto(s)
Quelantes del Hierro/administración & dosificación , Quelantes del Hierro/química , Sobrecarga de Hierro/tratamiento farmacológico , Piridonas/administración & dosificación , Piridonas/química , Administración Oral , Animales , Relación Dosis-Respuesta a Droga , Cobayas , Humanos , Sobrecarga de Hierro/sangre , Ratones , Ratas , Ratas Sprague-Dawley , Distribución Tisular/efectos de los fármacos , Distribución Tisular/fisiología
13.
Methods Mol Biol ; 2128: 225-239, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32180197

RESUMEN

Measurement of blood glucose concentration is a common end point in studies using animal models of diabetes. Usually a blood glucose meter is used to measure non-fasted blood glucose concentrations, typically at frequencies of between 1 and 7 times per week. This process involves pricking the tip of the tail to collect a small blood sample (0.5-5 µL), which could potentially cause a stress response and affect blood glucose concentrations. Moreover, with blood glucose concentrations constantly fluctuating in response to feeding and activity, a single-point measurement can easily misrepresent the actual glycemic control of the animal. In this chapter, we discuss the use of continuous glucose monitoring in mice by radio-telemetry which allows second-by-second changes in blood glucose to be captured without restraining the mouse. Glucose excursions rather than single-point measurements may prove more useful in detecting effects of treatments, and lack of handling may avoid stress responses causing artefacts. We outline what is involved in implanting such devices into mice including some practical tips to maximize success.


Asunto(s)
Automonitorización de la Glucosa Sanguínea/instrumentación , Glucemia/análisis , Monitoreo Fisiológico/métodos , Implantación de Prótesis/métodos , Telemetría/instrumentación , Telemetría/métodos , Animales , Estado de Conciencia/fisiología , Diabetes Mellitus Experimental , Locomoción/fisiología , Prótesis e Implantes
14.
Heart Rhythm O2 ; 1(5): 368-375, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33748801

RESUMEN

BACKGROUND: Life-threatening arrhythmias resulting from genetic mutations are often missed in current electrocardiogram (ECG) analysis. We combined a new method for ECG analysis that uses all the waveform data with machine learning to improve detection of such mutations from short ECG signals in a mouse model. OBJECTIVE: We sought to detect consequences of Na+ channel deficiencies known to compromise action potential conduction in comparisons of Scn5a+/- mutant and wild-type mice using short ECG signals, examining novel and standard features derived from lead I and II ECG recordings by machine learning algorithms. METHODS: Lead I and II ECG signals from anesthetized wild-type and Scn5a+/- mutant mice of length 130 seconds were analyzed by extracting various groups of features, which were used by machine learning to classify the mice as wild-type or mutant. The features used were standard ECG intervals and amplitudes, as well as features derived from attractors generated using the novel Symmetric Projection Attractor Reconstruction method, which reformulates the whole signal as a bounded, symmetric 2-dimensional attractor. All the features were also combined as a single feature group. RESULTS: Classification of genotype using the attractor features gave higher accuracy than using either the ECG intervals or the intervals and amplitudes. However, the highest accuracy (96%) was obtained using all the features. Accuracies for different subgroups of the data were obtained and compared. CONCLUSION: Detection of the Scn5a+/- mutation from short mouse ECG signals with high accuracy is possible using our Symmetric Projection Attractor Reconstruction method.

15.
Cell Rep ; 28(1): 218-230.e7, 2019 07 02.
Artículo en Inglés | MEDLINE | ID: mdl-31269442

RESUMEN

Classical activation of macrophages (M(LPS+IFNγ)) elicits the expression of inducible nitric oxide synthase (iNOS), generating large amounts of NO and inhibiting mitochondrial respiration. Upregulation of glycolysis and a disrupted tricarboxylic acid (TCA) cycle underpin this switch to a pro-inflammatory phenotype. We show that the NOS cofactor tetrahydrobiopterin (BH4) modulates IL-1ß production and key aspects of metabolic remodeling in activated murine macrophages via NO production. Using two complementary genetic models, we reveal that NO modulates levels of the essential TCA cycle metabolites citrate and succinate, as well as the inflammatory mediator itaconate. Furthermore, NO regulates macrophage respiratory function via changes in the abundance of critical N-module subunits in Complex I. However, NO-deficient cells can still upregulate glycolysis despite changes in the abundance of glycolytic intermediates and proteins involved in glucose metabolism. Our findings reveal a fundamental role for iNOS-derived NO in regulating metabolic remodeling and cytokine production in the pro-inflammatory macrophage.


Asunto(s)
Ciclo del Ácido Cítrico , Inflamación/metabolismo , Macrófagos/metabolismo , Óxido Nítrico/metabolismo , Succinatos/metabolismo , Animales , Biopterinas/análogos & derivados , Biopterinas/metabolismo , Ciclo del Ácido Cítrico/efectos de los fármacos , Transporte de Electrón/efectos de los fármacos , Endotoxemia/inducido químicamente , Endotoxemia/metabolismo , GTP Ciclohidrolasa/genética , GTP Ciclohidrolasa/metabolismo , Glucólisis/efectos de los fármacos , Interferón gamma/farmacología , Interleucina-1beta/metabolismo , Isocitrato Deshidrogenasa/metabolismo , Lipopolisacáridos/farmacología , Activación de Macrófagos/efectos de los fármacos , Macrófagos/efectos de los fármacos , Macrófagos/enzimología , Ratones , Ratones Noqueados , Mitocondrias/efectos de los fármacos , Mitocondrias/enzimología , Mitocondrias/metabolismo , Infecciones por Mycobacterium/metabolismo , Óxido Nítrico Sintasa de Tipo II/genética , Óxido Nítrico Sintasa de Tipo II/metabolismo , Fragmentos de Péptidos/metabolismo , Proteoma/genética , Proteoma/metabolismo , Ácido Succínico/metabolismo , Espectrometría de Masas en Tándem
16.
Physiol Meas ; 39(10): 104008, 2018 10 30.
Artículo en Inglés | MEDLINE | ID: mdl-30256216

RESUMEN

Current arterial pulse monitoring systems capture data at high frequencies (100-1000 Hz). However, they typically report averaged or low frequency summary data such as heart rate and systolic, mean and diastolic blood pressure. In doing so, a potential wealth of information contained in the high-fidelity waveform data is discarded, data which has long been known to contain useful information on cardiovascular performance. Here we summarise a new mathematical method, attractor reconstruction, which enables the quantification of arterial waveform shape and variability in real-time. The method can handle long streams of non-stationary data and does not require preprocessing of the raw physiological data by the end user. Whilst the detailed mathematical proofs have been described elsewhere (Aston et al 2008 Physiol. Meas. 39), the authors were motivated to write a summary of the method and its potential utility for biomedical researchers, physiologists and clinician readers. Here we illustrate how this new method may supplement and potentially enhance the sensitivity of detecting cardiovascular disturbances, to aid with biomedical research and clinical decision making.


Asunto(s)
Enfermedades Cardiovasculares/diagnóstico , Análisis de la Onda del Pulso/métodos , Enfermedades Cardiovasculares/fisiopatología , Enfermedades Cardiovasculares/terapia , Diagnóstico por Computador/métodos , Humanos , Sensibilidad y Especificidad
17.
JACC Basic Transl Sci ; 3(3): 366-377, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29963647

RESUMEN

Reduced nitric oxide (NO) bioavailability correlates with impaired cardiovascular function. NO is extremely labile and has been challenging to develop as a therapeutic agent. However, NO bioavailability could be enhanced by pharmacologically targeting endogenous NO regulatory pathways. Tetrahydrobiopterin, an essential cofactor for NO production, is synthesized by GTP cyclohydrolase-1 (GCH1), which complexes with GCH1 feedback regulatory protein (GFRP). The dietary amino acid l-phenylalanine activates this complex, elevating vascular BH4. Here, the authors demonstrate that l-phenylalanine administration restores vascular function in a rodent model of hypertension, suggesting the GCH1-GFRP complex represents a rational therapeutic target for diseases underpinned by endothelial dysfunction.

18.
Physiol Meas ; 39(2): 024001, 2018 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-29350622

RESUMEN

Advances in monitoring technology allow blood pressure waveforms to be collected at sampling frequencies of 250-1000 Hz for long time periods. However, much of the raw data are under-analysed. Heart rate variability (HRV) methods, in which beat-to-beat interval lengths are extracted and analysed, have been extensively studied. However, this approach discards the majority of the raw data. OBJECTIVE: Our aim is to detect changes in the shape of the waveform in long streams of blood pressure data. APPROACH: Our approach involves extracting key features from large complex data sets by generating a reconstructed attractor in a three-dimensional phase space using delay coordinates from a window of the entire raw waveform data. The naturally occurring baseline variation is removed by projecting the attractor onto a plane from which new quantitative measures are obtained. The time window is moved through the data to give a collection of signals which relate to various aspects of the waveform shape. MAIN RESULTS: This approach enables visualisation and quantification of changes in the waveform shape and has been applied to blood pressure data collected from conscious unrestrained mice and to human blood pressure data. The interpretation of the attractor measures is aided by the analysis of simple artificial waveforms. SIGNIFICANCE: We have developed and analysed a new method for analysing blood pressure data that uses all of the waveform data and hence can detect changes in the waveform shape that HRV methods cannot, which is confirmed with an example, and hence our method goes 'beyond HRV'.


Asunto(s)
Determinación de la Presión Sanguínea , Análisis de Datos , Frecuencia Cardíaca , Animales , Artefactos , Humanos , Ratones
19.
Am J Respir Cell Mol Biol ; 58(3): 331-340, 2018 03.
Artículo en Inglés | MEDLINE | ID: mdl-28957635

RESUMEN

Platelets have been implicated in pulmonary inflammatory cell recruitment after exposure to allergic and nonallergic stimuli, but little is known about the role of platelets in response to pulmonary infection with Pseudomonas aeruginosa. In this study, we have investigated the impact of the experimental depletion of circulating platelets on a range of inflammatory and bacterial parameters, and their subsequent impact on mortality in a murine model of pulmonary infection with P. aeruginosa. P. aeruginosa infection in mice induced a mild, but significant, state of peripheral thrombocytopenia in addition to pulmonary platelet accumulation. Increased platelet activation was detected in infected mice through increased levels of the platelet-derived mediators, platelet factor-4 and ß-thromboglobulin, in BAL fluid and blood plasma. In mice depleted of circulating platelets, pulmonary neutrophil recruitment was significantly reduced 24 hours after infection, whereas the incidence of systemic dissemination of bacteria was significantly increased compared with non-platelet-depleted control mice. Furthermore, mortality rates were increased in bacterial-infected mice depleted of circulating platelets. This work demonstrates a role for platelets in the host response toward a gram-negative bacterial respiratory infection.


Asunto(s)
Plaquetas/inmunología , Enfermedades Pulmonares/sangre , Infiltración Neutrófila/inmunología , Activación Plaquetaria/inmunología , Infecciones por Pseudomonas/inmunología , Pseudomonas aeruginosa/inmunología , Trombocitopenia/sangre , Animales , Líquido del Lavado Bronquioalveolar/inmunología , Enfermedades Pulmonares/inmunología , Enfermedades Pulmonares/microbiología , Ratones , Neutrófilos/inmunología , Recuento de Plaquetas , Factor Plaquetario 4/metabolismo , Infecciones por Pseudomonas/microbiología , Infecciones por Pseudomonas/patología , Trombocitopenia/inmunología , Trombocitopenia/patología , beta-Tromboglobulina/metabolismo
20.
J Am Heart Assoc ; 6(6)2017 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-28655735

RESUMEN

BACKGROUND: Reliable measurement of blood pressure in conscious mice is essential in cardiovascular research. Telemetry, the "gold-standard" technique, is invasive and expensive and therefore tail-cuff, a noninvasive alternative, is widely used. However, tail-cuff requires handling and restraint during measurement, which may cause stress affecting blood pressure and undermining reliability of the results. METHODS AND RESULTS: C57Bl/6J mice were implanted with radio-telemetry probes to investigate the effects of the steps of the tail-cuff technique on central blood pressure, heart rate, and temperature. This included comparison of handling techniques, operator's sex, habituation, and influence of hypertension induced by angiotensin II. Direct comparison of measurements obtained by telemetry and tail-cuff were made in the same mouse. The results revealed significant increases in central blood pressure, heart rate, and core body temperature from baseline following handling interventions without significant difference among the different handling technique, habituation, or sex of the investigator. Restraint induced the largest and sustained increase in cardiovascular parameters and temperature. The tail-cuff readings significantly underestimated those from simultaneous telemetry recordings; however, "nonsimultaneous" telemetry, obtained in undisturbed mice, were similar to tail-cuff readings obtained in undisturbed mice on the same day. CONCLUSIONS: This study reveals that the tail-cuff technique underestimates the core blood pressure changes that occur simultaneously during the restraint and measurement phases. However, the measurements between the 2 techniques are similar when tail-cuff readings are compared with telemetry readings in the nondisturbed mice. The differences between the simultaneous recordings by the 2 techniques should be recognized by researchers.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea , Hipertensión/diagnóstico , Cola (estructura animal)/irrigación sanguínea , Telemetría , Angiotensina II , Animales , Conducta Animal , Determinación de la Presión Sanguínea/efectos adversos , Determinación de la Presión Sanguínea/métodos , Regulación de la Temperatura Corporal , Modelos Animales de Enfermedad , Femenino , Habituación Psicofisiológica , Manejo Psicológico , Frecuencia Cardíaca , Humanos , Hipertensión/inducido químicamente , Hipertensión/fisiopatología , Hipertensión/psicología , Masculino , Ratones Endogámicos C57BL , Pletismografía/instrumentación , Valor Predictivo de las Pruebas , Flujo Sanguíneo Regional , Reproducibilidad de los Resultados , Restricción Física/efectos adversos , Estrés Psicológico/etiología , Estrés Psicológico/fisiopatología , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...