Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 74
Filtrar
1.
Talanta ; 276: 126197, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38728800

RESUMEN

Whereas the close associations of cesium ion with organochlorine compounds have been previously documented, the present report is the first attempt to exploit these interactions to create a trichloroethylene (TCE)-selective sensor. Gold monolayer-protected clusters peripherally functionalized with Cs+ ions were used to prepare a chemiresistance film on MEMS-fabricated interdigitated electrodes. Vapor sensing properties of the cesium-rich chemiresistor were determined using a panel of chlorinated hydrocarbons including TCE as well as polar and non-polar VOCs for comparison. The sensor was selective and highly sensitive toward VOCs containing a 1,2-dichloro group at concentrations as low as 0.1 ppm. The results suggest the key interaction contributing to sensor response is a bidentate, metallocycle-like coordination of the 1,2-dichloro group to the cesium cations at the sensor surface.

2.
J Breath Res ; 18(1)2023 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-37875100

RESUMEN

A 23-subject feasibility study is reported to assess how UV absorbance measurements on exhaled breath samples collected from silicon microreactors can be used to detect COVID-19. The silicon microreactor technology chemoselectively preconcentrates exhaled carbonyl volatile organic compounds and subsequent methanol elution provides samples for analysis. The underlying scientific rationale that viral infection will induce an increase in exhaled carbonyls appears to be supported by the results of the feasibility study. The data indicate statistically significant differences in measured UV absorbance values between healthy and symptomatic COVID-19 positive subjects in the wavelength range from 235 nm to 305 nm. Factors such as subject age were noted as potential confounding variables.


Asunto(s)
COVID-19 , Compuestos Orgánicos Volátiles , Humanos , Estudios de Factibilidad , Silicio , Pruebas Respiratorias/métodos , Análisis Espectral , Espiración , Compuestos Orgánicos Volátiles/análisis
3.
Anal Chem ; 95(9): 4344-4352, 2023 03 07.
Artículo en Inglés | MEDLINE | ID: mdl-36815760

RESUMEN

Analysis of volatile organic compounds (VOCs) in exhaled breath (EB) has shown great potential for disease detection including lung cancer, infectious respiratory diseases, and chronic obstructive pulmonary disease. Although many breath sample collection and analytical methods have been developed for breath analysis, analysis of metabolic VOCs in exhaled breath is still a challenge for clinical application. Many carbonyl compounds in exhaled breath are related to the metabolic processes of diseases. This work reports a method of ultrahigh-performance liquid chromatography coupled with high-resolution mass spectrometry (UHPLC-MS) for the analysis of a broad range of carbonyl metabolites in exhaled breath. Carbonyl compounds in the exhaled breath were captured by a fabricated silicon microreactor with a micropillar array coated with 2-(aminooxy)ethyl-N,N,N-trimethylammonium (ATM) triflate. A total of six subgroups consisting of saturated aldehydes and ketones, hydroxy-aldehydes, and hydroxy-ketones, unsaturated 2-alkenals, and 4-hydroxy-2-alkenals were identified in the exhaled breath. The combination of a silicon microreactor for the selective capture of carbonyl compounds with UHPLC-MS analysis may provide a quantitative method for the analysis of carbonyls to identify disease markers in exhaled breath.


Asunto(s)
Silicio , Compuestos Orgánicos Volátiles , Cromatografía Líquida de Alta Presión , Compuestos Orgánicos Volátiles/análisis , Aldehídos/análisis , Cetonas/análisis , Pruebas Respiratorias/métodos
4.
Talanta ; 253: 123915, 2023 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-36155323

RESUMEN

The strong, non-covalent interactions between π-systems and cations have been the focus of numerous studies on biomolecule structure and catalysis. These interactions, however, have yet to be explored as a sensing mechanism for detecting trace levels of volatile organic compounds (VOCs). In this article, we provide evidence that cation-π interactions can be used to elicit sensitive and selective chemiresistor responses to aromatic VOCs. The chemiresistors are fitted with carboxylate-linked alkali metals bound to the surface of gold monolayer-protected clusters formulated on microfabricated interdigitated electrodes. Sensor responses to aromatic and non-aromatic VOCs are consistent with a model for cation-π interactions arising from association of electron-rich aromatic π-systems to metal ions with the relative strength of attraction following the order K+ > Na+ > Li+. The results point toward cation-π interactions as a promising research avenue to explore for developing aromatic VOC-selective sensors.


Asunto(s)
Oro , Compuestos Orgánicos Volátiles , Cationes
5.
Metabolites ; 12(6)2022 Jun 18.
Artículo en Inglés | MEDLINE | ID: mdl-35736492

RESUMEN

The peroxidation of unsaturated fatty acids is a widely recognized metabolic process that creates a complex mixture of volatile organic compounds including aldehydes. Elevated levels of reactive oxygen species in cancer cells promote random lipid peroxidation, which leads to a variety of aldehydes. In the case of lung cancer, many of these volatile aldehydes are exhaled and are of interest as potential markers of the disease. Relevant studies reporting aldehydes in the exhaled breath of lung cancer patients were collected for this review by searching the PubMed and SciFindern databases until 25 May 2022. Information on breath test results, including the biomarker collection, preconcentration, and quantification methods, was extracted and tabulated. Overall, 44 studies were included spanning a period of 34 years. The data show that, as a class, aldehydes are significantly elevated in the breath of lung cancer patients at all stages of the disease relative to healthy control subjects. The type of aldehyde detected and/or deemed to be a biomarker is highly dependent on the method of exhaled breath sampling and analysis. Unsaturated aldehydes, detected primarily when derivatized during preconcentration, are underrepresented as biomarkers given that they are also likely products of lipid peroxidation. Pentanal, hexanal, and heptanal were the most reported aldehydes in studies of exhaled breath from lung cancer patients.

6.
Nanomedicine ; 44: 102572, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35671983

RESUMEN

We previously reported that hydroxylated oxime ether lipids (OELs) efficiently deliver functional Dicer substrate siRNAs (DsiRNAs) in cells. Here, we explored in vivo utility of these OELs, using OEL4 as a prototype and report that surface modification of the OEL4 formulations was essential for their in vivo applications. These surface-modified OEL4 formulations were developed by inclusion of various PEGylated lipids. The vesicle stability and gene knock-down were dependent on the PEG chain length. OEL4 containing DSPE-PEG350 and DSPE-PEG1000 (surprisingly not DSPE2000) promoted gene silencing in cells. In vivo studies demonstrated that OEL4 vesicles formulated using 3 mol% DSPE-PEG350 accumulate in human lung cancer (A549-luc2) xenografts in mice and exhibit a significant increase in tumor to liver ratios. These vesicles also showed a statistically significant reduction of luciferase signal in tumors compared to untreated mice. Taken together, the scalable OEL4:DSPE-PEG350 formulation serves as a novel candidate for delivery of RNAi therapeutics.


Asunto(s)
Éter , Neoplasias Pulmonares , Animales , Éteres , Xenoinjertos , Humanos , Lípidos , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/terapia , Ratones , Oximas , Polietilenglicoles , ARN Interferente Pequeño/genética
7.
J Chromatogr A ; 1673: 463083, 2022 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-35508097

RESUMEN

The analysis of toxic volatile organic compounds (VOCs) in environmental air is important because toxic VOCs induce adverse effects on human health. Although gas chromatography- mass spectrometry (GC-MS) is the standard instrument for analysis of trace VOCs in air, this mode of analysis requires preconcentration and cryogenic processes. The preconcentration and subsequent thermal desorption of VOCs require special instruments and a long time of processing sample that significantly limit applications of GC-MS for monitoring indoor and outdoor VOC levels. Using a microfabricated preconcentrator for VOC analysis also has the challenge of a large sample volume for concentration. Using solid-phase microextraction (SPME) for VOC analysis by GC-MS often approaches the limit of detection of the GC-MS instrument for trace VOCs in air. This work reports a simple method to integrate microfabricated preconcentrators with commercial SPME fibers in a two-stage concentration processes to achieve rapid and reliable measurement of trace VOCs in air by GC-MS. We designed and fabricated a preconcentrator with micropillars in a microfluidic chamber to support sorbents and to increase the heat transfer rate to the sorbents for rapid thermal desorption. The effects of air flow rates through the preconcentrator on VOCs adsorption and thermal desorption were optimized for increasing analytical accuracy of VOCs measurements. The integration of a micropreconcentrator with SPME enabled measurements of sub-ppb levels of benzene, toluene, ethylbenzene, and xylene (BTEX), and trichloroethylene (TCE) in environmental air by GC-MS.


Asunto(s)
Microextracción en Fase Sólida , Compuestos Orgánicos Volátiles , Cromatografía de Gases y Espectrometría de Masas/métodos , Humanos , Microextracción en Fase Sólida/métodos , Tolueno/análisis , Compuestos Orgánicos Volátiles/análisis , Xilenos/análisis
8.
Toxicol Appl Pharmacol ; 431: 115742, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34624356

RESUMEN

Benzene is a ubiquitous environmental pollutant. Recent population-based studies suggest that benzene exposure is associated with an increased risk for cardiovascular disease. However, it is unclear whether benzene exposure by itself is sufficient to induce cardiovascular toxicity. We examined the effects of benzene inhalation (50 ppm, 6 h/day, 5 days/week, 6 weeks) or HEPA-filtered air exposure on the biomarkers of cardiovascular toxicity in male C57BL/6J mice. Benzene inhalation significantly increased the biomarkers of endothelial activation and injury including endothelial microparticles, activated endothelial microparticles, endothelial progenitor cell microparticles, lung endothelial microparticles, and activated lung and endothelial microparticles while having no effect on circulating levels of endothelial adhesion molecules, endothelial selectins, and biomarkers of angiogenesis. To understand how benzene may induce endothelial injury, we exposed human aortic endothelial cells to benzene metabolites. Of the metabolites tested, trans,trans-mucondialdehyde (10 µM, 18h) was the most toxic. It induced caspases-3, -7 and -9 (intrinsic pathway) activation and enhanced microparticle formation by 2.4-fold. Levels of platelet-leukocyte aggregates, platelet macroparticles, and a proportion of CD4+ and CD8+ T-cells were also significantly elevated in the blood of the benzene-exposed mice. We also found that benzene exposure increased the transcription of genes associated with endothelial cell and platelet activation in the liver; and induced inflammatory genes and suppressed cytochrome P450s in the lungs and the liver. Together, these data suggest that benzene exposure induces endothelial injury, enhances platelet activation and inflammatory processes; and circulatory levels of endothelial cell and platelet-derived microparticles and platelet-leukocyte aggregates are excellent biomarkers of cardiovascular toxicity of benzene.


Asunto(s)
Benceno/toxicidad , Enfermedades Cardiovasculares/inducido químicamente , Sistema Cardiovascular/efectos de los fármacos , Animales , Enfermedades Asintomáticas , Benceno/administración & dosificación , Biomarcadores/sangre , Plaquetas/efectos de los fármacos , Plaquetas/metabolismo , Plaquetas/patología , Cardiotoxicidad , Enfermedades Cardiovasculares/sangre , Enfermedades Cardiovasculares/patología , Sistema Cardiovascular/metabolismo , Sistema Cardiovascular/patología , Micropartículas Derivadas de Células/efectos de los fármacos , Micropartículas Derivadas de Células/metabolismo , Micropartículas Derivadas de Células/patología , Células Endoteliales/efectos de los fármacos , Células Endoteliales/metabolismo , Células Endoteliales/patología , Células Madre Hematopoyéticas/efectos de los fármacos , Células Madre Hematopoyéticas/metabolismo , Células Madre Hematopoyéticas/patología , Exposición por Inhalación , Leucocitos/efectos de los fármacos , Leucocitos/metabolismo , Leucocitos/patología , Masculino , Ratones Endogámicos C57BL
9.
Sensors (Basel) ; 20(24)2020 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-33302491

RESUMEN

Increasing both the sensitivity and selectivity of thiol-functionalized gold nanoparticle chemiresistors remains a challenging issue in the quest to develop real-time gas sensors. The effects of thiol molecular structure on such sensor properties are not well understood. This study investigates the effects of steric as well as electronic effects in a panel of substituted thiol-urea compounds on the sensing properties of thiolate monolayer-protected gold nanoparticle chemiresistors. Three series of urea-substituted thiols with different peripheral end groups were synthesized for the study and used to prepare gold nanoparticle-based chemiresistors. The responses of the prepared sensors to trace volatile analytes were significantly affected by the urea functional motifs. The largest response for sensing acetone among the three series was observed for the thiol-urea sensor featuring a tert-butyl end group. Furthermore, the ligands fitted with N, N'-dialkyl urea moieties exhibit a much larger response to carbonyl analytes than the more acidic urea series containing N-alkoxy-N'-alkyl urea and N, N'-dialkoxy urea groups with the same peripheral end groups. The results show that the peripheral molecular structure of thiolate-coated gold nanoparticles plays a critical role in sensing target analytes.

10.
Nanoscale ; 12(22): 12027-12037, 2020 Jun 11.
Artículo en Inglés | MEDLINE | ID: mdl-32467955

RESUMEN

To enhance catalytic activity, the present study details a general approach for partial thiolate ligand removal from monolayer-protected clusters (MPCs) by straightforward in situ addition of iodine. Two model reactions are examined to illustrate the effects on the catalytic activity of glutathione (SG)-capped Au MPCs serving as a catalyst for the NaBH4 reduction of 4-nitrophenol to 4-aminophenol and SG-capped Pd MPCs serving as a catalyst for the hydrogenation/isomerization of allyl alcohol. Iodine addition promoted partial thiolate ligand removal from both MPCs and improved the catalytic properties, presumably due to greater surface exposure of the metal cores as a result of ligand dissociation. The rate of 4-nitrophenol reduction increased from 0.066 min-1 in the absence of I2 to 0.505 min-1 in the presence of 2.0 equivalents I2 (equivalents based on total ligated glutathione). The reaction of allyl alcohol to produce 1-propanol and propanal was similarly accelerated as indicated by the increase in turnover frequency from 131 to 230 moles products per moles catalyst per h by addition of 0.2 equivalents I2. In both reactions, as the amount of I2 added increases the catalyst recyclability decreases due to catalyst instability. Low equivalents of I2 are optimal when considering both reaction rate and catalyst recyclability.

11.
Chemphyschem ; 20(6): 815-822, 2019 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-30725495

RESUMEN

The click-chemistry capture of volatile aldehydes and ketones by ammonium aminooxy compounds has proven to be an efficient means of analyzing the carbonyl subset in complex mixtures, such as exhaled breath or environmental air. In this work, we examine the carbonyl condensation reaction kinetics of three aminooxy compounds with varying ß-ammonium ion substitution using Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). We determined the activation energies for the reactions of the aminooxy compounds ATM, ADMH and AMAH with a panel of ketones and aldehydes that included acrolein and crotonaldehyde. The measurements indicate that the activation energies for the oximation reactions are quite low, less than 75 kJ mol-1 . ADMH is observed to react the fastest with the carbonyls studied. We postulate this result may be attributed to the ADMH ammonium proton effecting a Brønsted-Lowry acid-catalyzed elimination of water during the rate-determining step of oxime ether formation. A theoretical study of oxime ether formation is presented to explain the enhanced reactivity of ADMH relative to the tetraalkylammonium analog ATM.


Asunto(s)
Aldehídos/química , Compuestos de Amonio/química , Cetonas/química , Cinética , Espectrometría de Masas , Estructura Molecular
12.
J Org Chem ; 84(6): 3249-3259, 2019 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-30758961

RESUMEN

We report that HCl·DMPU induces the formation of (thiomethyl)methyl carbenium ion from DMSO under mild conditions. Homoallylic amines react with this electrophile to generate 4-chloropiperidines in good yields. The method applies to both aromatic and aliphatic amines. The use of HCl·DMPU as both non-nucleophilic base and chloride source constitutes an environmentally benign alternative for piperidine formation. The reaction has a broad substrate scope, and the conditions offer good chemical yields with high functional group tolerance and scalability.

13.
Part Part Syst Charact ; 36(7)2019 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-33299268

RESUMEN

Aminooxy (-ONH2) groups are well known for their chemoselective reactions with carbonyl compounds, specifically aldehydes and ketones. The versatility of aminooxy chemistry has proven to be an attractive feature that continues to stimulate new applications. This work describes application of aminooxy 'click chemistry' on the surface of gold nanoparticles. We present here a trifunctional amine-containing aminooxy alkane thiol ligand for use in the functionalization of gold monolayer protected clusters (Au MPCs). Diethanolamine is readily transformed into an organic-soluble aminooxy thiol (AOT) ligand using a short synthetic path. The synthesized AOT ligand was coated on ≤ 2 nm diameter hexanethiolate (C6S)-capped Au MPCs using a ligand exchange protocol to afford organic-soluble AOT/C6S (1:1 ratio) Au mixed monolayer protected clusters (MMPCs). This work describes the synthesis of Au(C6S)(AOT) MMPCs and representative oximation reactions with various types of aldehyde-containing molecules, highlighting the ease and versatility of the chemistry and how amine protonation can be used to switch solubility characteristics.

14.
RSC Adv ; 8(62): 35618-35624, 2018 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-30555687

RESUMEN

Chemiresistor-based gas sensors for detection of target volatile organic compounds (VOCs) in air face common challenges of poor sensitivity and selectivity as well as suffering from interference by other constituent gases and/or humidity. This work demonstrates that functionalizing gold nanoparticles (AuNPs) with a designed thiol monolayer improves sensitivity and selectivity of the derived AuNPs gas sensor. We report the synthesis and application of a thiol ligand fitted with both a urea motif and a tert-butyl end group for functionalizing AuNPs. The AuNPs sensor prepared using the urea thiol ligand demonstrated significantly increased acetone sensing in comparison with tested commercially available thiol-functionalized AuNPs. The sensor worked under ambient temperature and high humidity conditions, and demonstrated a linear relationship between the sensor response and the common logarithm of analyte concentration.

15.
ACS Omega ; 3(6): 6764-6769, 2018 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-29978147

RESUMEN

Aldehydes including formaldehyde, acetaldehyde, and acrolein are toxic organic components of air pollution that cause lung cancer and cardiovascular disease with chronic exposure. The commonly used method for determining the levels of carbonyl compounds based on the derivatizing agent 2,4-dinitrophenylhydrazine is of limited use for ketones and unsaturated aldehydes because of issues such as low capture efficiencies, unstable derivatives, and long sample collection times. This work details the analysis of carbonyls in ambient air by a microreactor approach. The microreactor is fabricated on a silicon wafer and has thousands of micropillars in a microfluidic channel for uniformly distributing the air flow through the channel. The surfaces of the micropillars are coated with a quaternary ammonium aminooxy reagent, 2-(aminooxy)ethyl-N,N,N-trimethylammonium iodide (ATM), for chemoselective capture of carbonyl compounds by means of oximation reactions. ATM-carbonyl adducts are eluted from the microreactor and directly analyzed by Fourier transform ion cyclotron resonance mass spectrometry and ultrahigh-performance liquid chromatography-mass spectrometry. More than 20 carbonyls were detected in ambient air samples. Acetone, 2-butanone, acetaldehyde, and formaldehyde were the most abundant carbonyls in ambient air of the studied urban areas.

16.
Analyst ; 143(4): 999, 2018 02 12.
Artículo en Inglés | MEDLINE | ID: mdl-29359211

RESUMEN

Correction for 'Quantitative profiling of carbonyl metabolites directly in crude biological extracts using chemoselective tagging and nanoESI-FTMS' by Pan Deng, et al., Analyst, 2018, 143, 311-322.

17.
Aerosol Sci Technol ; 52(11): 1219-1232, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-31456604

RESUMEN

Electronic cigarettes (e-cigarette) have emerged as a popular electronic nicotine delivery system (ENDS) in the last decade. Despite the absence of combustion products and toxins such as carbon monoxide (CO) and tobacco-specific nitrosamines (TSNA), carbonyls including short-chain, toxic aldehydes have been detected in e-cigarette-derived aerosols up to levels found in tobacco smoke. Given the health concerns regarding exposures to toxic aldehydes, understanding both aldehyde generation in e-cigarette and e-cigarette exposure is critical. Thus, we measured aldehydes generated in aerosols derived from propylene glycol (PG):vegetable glycerin (VG) mixtures and from commercial e-liquids with flavorants using a state-of-the-art carbonyl trap and mass spectrometry. To track e-cigarette exposure in mice, we measured urinary metabolites of 4 aldehydes using ULPC-MS/MS or GC-MS. Aldehyde levels, regardless of abundance (saturated: formaldehyde, acetaldehyde >> unsaturated: acrolein, crotonaldehyde), were dependent on the PG:VG ratio and the presence of flavorants. The metabolites of 3 aldehydes - formate, acetate and 3-hydroxypropyl mercapturic acid (3-HPMA; acrolein metabolite) -- were increased in urine after e-cigarette aerosol and mainstream cigarette smoke (MCS) exposures, but the crotonaldehyde metabolite (3-hydroxy-1-methylpropylmercapturic acid, HPMMA) was increased only after MCS exposure. Interestingly, exposure to menthol-flavored e-cigarette aerosol increased the levels of urinary 3-HPMA and sum of nicotine exposure (nicotine, cotinine, trans-3'-hydroxycotinine) relative to exposure to a Classic Tobacco-flavored e-cigarette aerosol. Comparing these findings with aerosols of other ENDS and by measuring aldehyde-derived metabolites in human urine following exposure to e-cigarette aerosols will further our understanding of the relationship between ENDS use, aldehyde exposure and health risk.

18.
Analyst ; 143(1): 311-322, 2017 12 18.
Artículo en Inglés | MEDLINE | ID: mdl-29192912

RESUMEN

The extensive range of chemical structures, wide range of abundances, and chemical instability of metabolites present in the metabolome pose major analytical challenges that are difficult to address with existing technologies. To address these issues, one approach is to target a subset of metabolites that share a functional group, such as ketones and aldehydes, using chemoselective tagging. Here we report a greatly improved chemoselective method for the quantitative analysis of hydrophilic and hydrophobic carbonyl-containing metabolites directly in biological samples. This method is based on direct tissue or cells extraction with simultaneous derivatization of stable and labile carbonylated metabolites using N-[2-(aminooxy)ethyl]-N,N-dimethyl-1-dodecylammonium (QDA) and 13CD3 labeled QDA. We combined innovations of direct quenching of biological sample with frozen derivatization conditions under the catalyst N,N-dimethyl-p-phenylenediamine, which facilitated the formation of oxime stable-isotope ion pairs differing by m/z 4.02188 while minimizing metabolite degradation. The resulting oximes were extracted by HyperSep C8 tips to remove interfering compounds, and the products were detected using nano-electrospray ionization interfaced with a Thermo Fusion mass spectrometer. The quaternary ammonium tagging greatly increased electrospray MS detection sensitivity and the signature ions pairs enabled simple identification of carbonyl compounds. The improved method showed the lower limits of quantification for carbonyl standards to be in the range of 0.20-2 nM, with linearity of R2 > 0.99 over 4 orders of magnitude. We have applied the method to assign 66 carbonyls in mouse tumor tissues, many of which could not be assigned solely by accurate mass and tandem MS. Fourteen of the metabolites were quantified using authentic standards. We also demonstrated the suitability of this method for determining 13C labeled isotopologues of carbonyl metabolites in 13C6-glucose-based stable isotope-resolved metabolomic (SIRM) studies.

19.
Anal Methods ; 9(29): 4261-4266, 2017 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-29187865

RESUMEN

The electronic cigarette (e-cigarette) has emerged as popular electronic nicotine delivery devices (ENDs). However, the general safety and validity of e-cigarettes for nicotine delivery efficacy are still not well understood. This study developed a new method for efficient measurement of nicotine levels in both the liquids (e-liquids) used in e-cigarettes and the aerosols generated from the e-cigarettes. Protonation of the pyrrolidine nitrogen of nicotine molecules by addition of excess hydrochloric acid affords an aminium salt that is readily quantified by Fourier transform ion cyclotron mass spectrometry (FT-ICR-MS). The kinetics of nicotine protonation was studied using 1H NMR spectroscopy. Quantitative analyses of nicotine in commercial e-liquids and in the corresponding derived e-cigarette aerosols were carried out using direct infusion FT-ICR-MS. The 1H NMR study of nicotine protonation revealed a first order reaction and an activation energy of 30.05 kJ mol-1. The nicotine levels measured in the commercial e-liquids were within a wide and highly variable range of -2.94% to +25.20% around the manufacturer's stated values. The results indicated considerable differences between the measured levels and the advertised levels of nicotine in the e-liquids. The nicotine quantity measured in aerosols increased linearly both with nicotine level in e-liquids (same number of puffs) and with number of puffs (same e-liquids). These data show that quality control of e-liquids and use characteristics are major variables in efficacy of nicotine delivery.

20.
ACS Omega ; 2(3): 1207-1214, 2017 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-28393137

RESUMEN

Acetaldehyde, acrolein, and formaldehyde are the principal toxic aldehydes present in cigarette smoke and contribute to the risk of cardiovascular disease and noncancerous pulmonary disease. The rapid growth of the use of electronic cigarettes (e-cigarettes) has raised concerns over emissions of these harmful aldehydes. This work determines emissions of these aldehydes in both free and bound (aldehyde-hemiacetal) forms and other carbonyls from the use of e-cigarettes. A novel silicon microreactor with a coating phase of 4-(2-aminooxyethyl)-morpholin-4-ium chloride (AMAH) was used to trap carbonyl compounds in the aerosols of e-cigarettes via oximation reactions. AMAH-aldehyde adducts were measured using gas chromatography-mass spectrometry. 1H nuclear magnetic resonance spectroscopy was used to analyze hemiacetals in the aerosols. These aldehydes were detected in the aerosols of all e-cigarettes. Newer-generation e-cigarette devices generated more aldehydes than the first-generation e-cigarettes because of higher battery power output. Formaldehyde-hemiacetal was detected in the aerosols generated from some e-liquids using the newer e-cigarette devices at a battery power output of 11.7 W and above. The emission of these aldehydes from all e-cigarettes, especially higher levels of aldehydes from the newer-generation e-cigarette devices, indicates the risk of using e-cigarettes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...