Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 146
Filtrar
1.
Eur J Heart Fail ; 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38629741

RESUMEN

AIMS: Standardized immunosuppressive therapy (IS) had been previously investigated in biopsy-proven (BP) lymphocytic myocarditis with heart failure (HF). This study evaluated efficacy and safety of tailored IS in BP immune-mediated myocarditis, irrespective of histology and clinical presentation. METHODS AND RESULTS: Consecutive BP myocarditis patients treated with long-term tailored IS on top of optimal medical therapy (OMT), were compared with OMT non-IS controls using propensity-score weighting. The primary outcome was a composite of death or heart transplant, the secondary outcome was a composite of biventricular function, New York Heart Association (NYHA) class variation, and relapse. IS was managed by a multidisciplinary Cardioimmunology Team, involved a safety checklist and active patients' education. Ninety-one IS patients were compared with 267 non-IS patients. IS patients more frequently had systemic immune-mediated diseases (35% vs. 9.7%), lower baseline echocardiographic left ventricular ejection fraction (35% vs. 43%), lower right ventricular fractional area change (34% vs. 41%) and higher frequency of active lymphocytic, eosinophilic and giant cell myocarditis (71% vs. 58%, 12% vs. 1.1%, and 6.6% vs. 1.5%, respectively). At 5-year follow up, no difference was observed in the primary outcome (survival rate 93% in IS vs. 87% in non-IS), but IS patients had a higher relapse rate. Thus, IS patients, with a lower biventricular function and a higher risk profile at baseline, presented similar biventricular function and NYHA class to non-IS patients at follow-up. Minor adverse drug reactions occurred in 13% of patients, all resolved with therapy switch. CONCLUSIONS: Prolonged tailored IS is effective and safe in BP immune-mediated myocarditis irrespective of histology and clinical presentation.

2.
Heart ; 110(1): 27-34, 2023 Dec 15.
Artículo en Inglés | MEDLINE | ID: mdl-37414524

RESUMEN

OBJECTIVE: The European Society of Cardiology guidelines have recently defined new cut-offs for pulmonary hypertension (PH) and pulmonary vasculature resistance (PVR; median pulmonary artery pressure (mPAP) >20 instead of 25 mm Hg and PVR >2 instead of 3 Wood unit). The prognostic value of this updated classification after transcatheter aortic valve implantation (TAVI) is unknown. METHODS: 579 consecutive patients treated by TAVI with preprocedural right heart catheterisation evaluation were included. Patients were grouped as: (1) no PH, (2) isolated precapillary/combined (I-PreC/Co) PH and (3) isolated postcapillary PH (I-PoC). All-cause death, cardiovascular death and hospitalisations for heart failure (HF) were evaluated at follow-up. We also analysed the prognostic role of residual postprocedural PH. RESULTS: Out of 579 patients, 299 (52%) had PH according to the new criteria compared with 185 (32%) according to the previous ones. Overall median age was 82 years, while 55.3% patients were male. Patients with PH were more frequently diagnosed with chronic obstructive pulmonary disease and atrial fibrillation and were characterised by higher surgical risk as compared with patients without PH.At a median follow-up of 2.9 years, the presence of PH according to previous definition was associated with worse survival (p<0.001) and HF hospitalisation (p=0.002) rates, irrespective of PVR values. With newer cut-offs, PH was associated with worse outcomes only in patients with increased PVR, while no differences were found between patients with PH and normal PVR values and those without PH. Postprocedural mPAP normalisation was observed in 45% of the cases, but it was associated with improved long-term survival only in the I-PoC PH group. CONCLUSIONS: New ESC PH cut-offs increased the number of PH diagnoses. The presence of PH, particularly in the setting of increased PVR, identify patients at higher risk for postprocedural mortality and rehospitalisation. Normalisation of PH was associated with better survival only in I-PoC group.


Asunto(s)
Estenosis de la Válvula Aórtica , Insuficiencia Cardíaca , Hipertensión Pulmonar , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Hipertensión Pulmonar/diagnóstico , Hipertensión Pulmonar/etiología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico , Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Pronóstico , Resultado del Tratamiento , Factores de Riesgo
3.
Curr Probl Cardiol ; 48(8): 101734, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37044271

RESUMEN

Aim of this single-center, retrospective study was to assess early and long-term clinical and hemodynamic results of transapical aortic valve implantation (TA-TAVI), and to identify predictors of survival at follow-up. All patients undergoing TA-TAVI for severe aortic valve stenosis at our institution were reviewed. A hybrid approach based on machine-learning techniques was employed to identify survival predictors, using a bagging-decision-tree algorithm and a Random-Forest algorithm, respectively. Two-hundred-thirty-four consecutive patients underwent TA-TAVI (March 2009-May 2019). All cause 30-day mortality was 5.1%. Device success was 95.7%. Median follow-up time was 35.2 months. Kaplan-Meier overall survival rates at 2, 5, and 8 years were 75%, 44%, and 15%, respectively. Structural-valve-deterioration occurred in 25 patients (11.3%) overall. The strongest predictors of survival at follow-up were age, body-mass-index, and ejection fraction. TA-TAVI provided valid early and long-term outcomes. These data support its choice as an optimal alternative access whenever the transfemoral route is not feasible.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estudios Retrospectivos , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Hemodinámica
4.
EuroIntervention ; 18(13): e1108-e1119, 2023 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-36043326

RESUMEN

BACKGROUND: Data on left main (LM) percutaneous coronary interventions (PCI) have mostly been obtained in studies using drug-eluting stent (DES) platforms without dedicated large-vessel devices and with limited expansion capability. AIMS: Our study aimed to investigate the safety and efficacy of LM PCI with the latest-generation Resolute Onyx DES. METHODS: ROLEX (Revascularization Of LEft main with resolute onyX) is a prospective, multicentre study (ClinicalTrials.gov: NCT03316833) enrolling patients with unprotected LM coronary artery disease and a SYNTAX score <33 undergoing PCI with the Resolute Onyx zotarolimus-eluting coronary stent, that includes dedicated extra-large vessel platforms. The primary endpoint (EP) was target lesion failure (TLF): a composite of cardiac death, target vessel myocardial infarction (TVMI) and ischaemia-driven target lesion revascularisation (ID-TLR), at 1 year. All events were adjudicated by an independent clinical event committee. An independent core lab analysed all procedural angiograms. RESULTS: A total of 450 patients (mean age 71.8 years, SYNTAX score 24.5±7.2, acute coronary syndrome in 53%) were enrolled in 26 centres. Of these, 77% of subjects underwent PCI with a single-stent and 23% with a 2-stent technique (8% double kissing [DK] crush, 6% culotte, 9% T/T and small protrusion [TAP] stenting). Intravascular imaging guidance was used in 45% (42% intravascular ultrasound [IVUS], 3% optical coherence tomography [OCT]). At 1 year, the primary EP incidence was 5.1% (cardiac death 2.7%, TVMI 2.7%, ID-TLR 2.0%). The definite/probable stent thrombosis rate was 1.1%. In a prespecified adjusted subanalysis, the primary EP incidence was significantly lower in patients undergoing IVUS/OCT-guided versus angio-guided PCI (2.0 vs 7.6%; hazard ratio [HR] 0.28, 95% confidence interval [CI]: 0.13-0.58; p<0.001). CONCLUSIONS: In this large, multicentre, prospective registry, LM PCI with the Resolute Onyx DES showed good safety and efficacy at 1 year, particularly when guided by intracoronary imaging.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Anciano , Intervención Coronaria Percutánea/efectos adversos , Stents Liberadores de Fármacos/efectos adversos , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Infarto del Miocardio/etiología , Stents/efectos adversos , Angiografía/efectos adversos , Angiografía Coronaria/métodos
5.
Front Cardiovasc Med ; 9: 1056496, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36578836

RESUMEN

Objectives: To assess the impact of conventional transcatheter heart valve (THV) commissural alignment techniques on THV/coronary overlap and coronary access (CA) after transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV). Background: Specific Evolut Pro/Pro + and Acurate Neo2 THV orientations are associated with reduced neo-commissural overlap with coronary ostia in tricuspid aortic anatomy. Whether standard orientation techniques are effective also in the setting of BAV anatomy has not been studied. Methods: The DA VINCI (Definition of trAnscatheter aortic Valve orIeNtation in biCuspId aortic valve) pilot study is a prospective registry enrolling consecutive patients with severe BAV stenosis undergoing TAVR with last generation supra-annular tall-frame THVs implanted with a cusp overlap view-based commissural alignment. Patients underwent pre- and post-TAVR computed tomography (CT) and coronary angiography. The study endpoint was the rate of favorable THV/coronary overlap, defined as an angle > 40° between the THV commissural post and coronary ostia. Other endpoints were the rates of successful THV alignment with respect to the raphe and of selective CA after TAVR. Moreover, different virtual THV alignment models were tested to identify which one would produce the lower degree of THV/coronary overlap. Results: Thirty-four patients with type 1 BAV with right-left raphe undergoing TAVR (23 with Evolut Pro/Pro + and 11 with Acurate Neo2) were included. At pre-TAVR CT, moderate/severe cusp asymmetry was found in 50% of patients, severe coronary ostia eccentricity was observed in 47.1% for the RCA vs. 8.8% for the LCA (P < 0.007). Correct TVH orientation was achieved in 29 cases. At post-TAVR CT, optimal THV alignment/mild misalignment to the raphe was observed in 86.2%, but a moderate/severe overlap with the coronaries was seen in 13.7% for the RCA and 44.8% for the LCA (P = 0.019). After TAVR, selective RCA cannulation was possible in 82.8% vs. 75.9% for the LCA (P = 0.74), while combined selective CA of both coronaries was possible in less than two-thirds of the patients. Virtual THV alignment in the coronary ostia overlap view assuming a hypothetical circular THV expansion would produce an optimal THV/coronary overlap in almost 90% of cases. Conclusion: Given cusp asymmetry and coronary ostia eccentricity of BAV combined with potential THV asymmetrical expansion, conventional commissural alignment techniques are associated with higher rates of THV misalignment and of moderate/severe neo-commissure overlap with the coronary ostia as compared to tricuspid aortic stenosis, resulting in lower rates of selective CA after TAVR. A modified THV orientation technique based on the coronary ostia overlap view might be preferable in BAV patients.

6.
J Pers Med ; 12(9)2022 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-36143266

RESUMEN

The use of percutaneous right ventricular assist devices (pRVADs) to support patients with right ventricular (RV)-predominant cardiogenic shock (CS) refractory to optimal medical therapy is increasing progressively, and the Impella RP is the first FDA-approved pRVAD in such a clinical scenario. The aim of the present study is to report the outcomes of patients treated with Impella RP in the IMP-IT (IMPella Mechanical Circulatory Support Device in Italy) registry, a multicenter registry that evaluated the trends in use and clinical outcomes of the Impella in the setting of CS and high-risk percutaneous coronary intervention in Italy. A total of 15 patients who received Impella RP were enrolled. In 40% of the patients, the main cause was ST-segment elevation myocardial infarction. A total of 40% of patients required biventricular support with a left Impella. Device-related complications were reported in 46.7% of patients. Overall, the in-hospital mortality was 46.7%, whereas the one-year mortality was 53.3%. The composite rate of all-cause death, heart failure (HF) hospitalization, left ventricular assist device (LVAD) and heart transplant at one year was 60%. The Impella RP has favorable survival outcomes in RV-predominant cardiogenic shock. However, the device-related complications are frequent and should be carefully weighed when considering escalation to Impella RP.

7.
Front Cardiovasc Med ; 9: 924958, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757343

RESUMEN

Background: The impact of transcatheter aortic valve replacement (TAVR) leaflet design on long-term device performance is still unknown. This study sought to compare the clinical and hemodynamic outcomes of intra- (IA) versus supra-annular (SA) TAVR designs up-to 10-years following implantation. Methods: Consecutive patients with at least 5-years follow-up following TAVR for severe symptomatic aortic stenosis from June 2007 to December 2016 were included. Bioprosthetic valve failure (BVF) and hemodynamic valve deterioration (HVD) were defined according to VARC-3 updated definitions and estimated using cumulative incidence function to account for the competing risk of death. Results: A total of 604 patients (82 years; 53% female) were analyzed and divided into IA (482) and SA (122) groups. Overall survival rates at 10-years were similar (IA 15%, 95%CI: 10-22; SA 11%, 95%CI: 6-20; p = 0.21). Compared to the SA TAVR, mean transaortic gradients were significantly higher and increased over time in the IA group. IA TAVRs showed higher 10-year cumulative incidences of BVF (IA 8% vs. SA 1%, p = 0.02) and severe HVD (IA 5% vs. SA 1%, p = 0.05). The occurrence of BVF and HVD in the IA group occurred primarily in the smallest TAVR devices (20-23-mm). After excluding these sizes, the cumulative incidences of BVF (IA 5% vs. SA 1%, p = 0.40) and severe HVD (IA 2% vs. SA 1%, p = 0.11) were similar. Conclusion: In this study, TAVR leaflet design had no impact on survival at 10-years. IA devices showed higher transaortic gradients and cumulative incidences of HVD and BVF predominantly occurring in the smallest valve sizes.

8.
Chest ; 161(5): e259-e263, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35526894

RESUMEN

CASE PRESENTATION: A 16-year-old male patient was admitted to our Cardiology Department for new-onset exertional dyspnea (NYHA functional class II-III). He had no family history of cardiovascular diseases, no cardiovascular risk factors, and an unremarkable medical history, except for a blunt chest trauma after a motorbike accident 2 years earlier.


Asunto(s)
Traumatismos Torácicos , Heridas no Penetrantes , Adolescente , Disnea/diagnóstico , Disnea/etiología , Humanos , Masculino , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/diagnóstico , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico
9.
Front Cardiovasc Med ; 9: 832242, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35295263

RESUMEN

Backgrounds: Among vascular closure devices (VCDs), the novel collagen plug-based MANTA VCD is the first designed for large bore percutaneous access. We aimed to assess the features and predictors of access-site vascular complications in an unselected trans-femoral transcatheter aortic valve replacement (TF-TAVR) population. Methods: Patients undergoing large bore arteriotomy closure with 18F MANTA VCD following TF-TAVR at a large tertiary care center from September 2019 to January 2021 were prospectively analyzed. Primary Outcome was the MANTA VCD access-site-related complications according to Valve Academic Research Consortium-3 (VARC) definitions. Its incidence and predictors were evaluated. Results: Eighty-eight patients (median age 82 years, 48% male, 3.3 median Society of Thoracic Surgeons score) undergoing TF-TAVR were included, mostly (63%) treated with a self-expandable device and with outer diameter sizes varied from 18F to 24-F. MANTA VCD technical success rate was 98%, while 10 patients (11%) experienced MANTA VCD access-site vascular complications which included 8% of minor complications and only to 2% of major events resulting in VARC type ≥2 bleeding. Vessel occlusion/stenosis (60%), perforation (20%), and pseudoaneurysm/dissection/hematoma (20%) occurred, but all were managed without surgical treatment. Independent predictors of failure were age (p = 0.04), minimum common femoral artery diameter (CFA) (p < 0.01), sheath-to-femoral-artery ratio (SFAR) (p < 0.01), and a lower puncture height (p = 0.03). A CFA diameter <7.1 mm with a SFAR threshold of 1.01 were associated with VCD failure. Conclusions: In a more comers TF-TAVR population, MANTA VCD was associated with reassuring rates of technical success and major access-site vascular complications. Avoiding lower vessel size and less puncture site distance to CFA bifurcation might further improve outcomes.

10.
Circ Cardiovasc Interv ; 15(2): e011045, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-35167332

RESUMEN

BACKGROUND: Coronary access (CA) after transcatheter aortic valve replacement (TAVR) with supra-annular transcatheter heart valves (THV) can be challenging. Specific Evolut R/Pro and Acurate Neo THVs orientations are associated with reduced neo-commissure overlap with coronary ostia, while SAPIEN 3 THV cannot be oriented. With the ALIGN-ACCESS study (TAVR With Commissural Alignment Followed by Coronary Access), we investigated the impact of commissural alignment on the feasibility of CA after TAVR. METHODS: We performed coronary angiography after TAVR with intra-annular SAPIEN 3, supra-annular Evolut R/Pro, and Acurate Neo THVs in 206 patients. Evolut THVs were implanted aiming for commissure alignment. Alignment of Acurate Neo was retrospectively assessed in 36, intentionally attempted in 26 cases. The primary end point was the rate of unfeasible and nonselective CA after TAVR. RESULTS: Thirty-eight percent of patients received SAPIEN 3, 31.1% Evolut Pro/R, 30.1% Acurate Neo THV. Final valve orientation was favorable to commissural alignment in 85.9% of Evolut and 69.4% of Acurate Neo cases (with intentional alignment successful in 88.5%). Selective CA was higher for SAPIEN 3 than for aligned and misaligned supra-annular THVs (95% versus 71% versus 46%, P<0.001). Cannulation of at least one coronary was unfeasible with 11% misaligned supra-annular, 3% aligned supra-annular, and 0% SAPIEN 3 THVs. Independent predictors of unfeasible/nonselective CA were implantation of a misaligned supra-annular THV (odds ratio, 4.59 [95% CI, 1.81-11.61]; P<0.01), sinus of Valsalva height (odds ratio, 0.83 [95% CI, 0.7-0.98]; P=0.03), and THV-sinus of Valsalva relation (odds ratio, 1.06 [95% CI, 1.02-1.1]; P<0.01). CONCLUSIONS: Commissural alignment improves the rate of selective CA after TAVR with supra-annular THVs. Nevertheless, aligned supra-annular THVs carry higher risk of unfeasible/nonselective CA than SAPIEN 3. Patients with a misaligned supra-annular THV, low sinus of Valsalva, and higher THV-sinus of Valsalva relation are at highest risk of impaired CA after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
11.
ESC Heart Fail ; 8(5): 4313-4317, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34173727

RESUMEN

Effusive-constrictive pericarditis (ECP) is an uncommon diagnosis, frequently missed due to its heterogeneous presentation, but a potentially reversible cause of heart failure. A 62-year-old Caucasian male presented with remittent right heart failure and mild-moderate pericardial effusion. Following an initial diagnosis of idiopathic pericarditis, indomethacin was started, but the patient shortly relapsed, presenting with severe pericardial effusion and signs of cardiac tamponade, requiring pericardiocentesis. ECP was diagnosed on cardiac catheterization. Cardiac computed tomography showed non-calcified, mildly thickened and inflamed parietal pericardium. Pericardiectomy was performed with symptoms remission. On histological examination of pericardium, chronic non-necrotizing granulomatous inflammation was noted. Polymerase chain reaction assay was positive for non-tuberculous mycobacteria. This case represents a rare finding of ECP with unusual presentation due to atypical mycobacteriosis in a non-immunocompromised patient and in a non-endemic area. Pericardiectomy can be an effective option in cases unresponsive to anti-inflammatory treatment, even in the absence of significant pericardial thickening or calcification.


Asunto(s)
Taponamiento Cardíaco , Derrame Pericárdico , Pericarditis Constrictiva , Taponamiento Cardíaco/diagnóstico , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/cirugía , Humanos , Masculino , Persona de Mediana Edad , Derrame Pericárdico/diagnóstico , Derrame Pericárdico/etiología , Derrame Pericárdico/cirugía , Pericardiectomía , Pericardiocentesis , Pericarditis Constrictiva/diagnóstico , Pericarditis Constrictiva/etiología , Pericarditis Constrictiva/cirugía
12.
J Am Coll Cardiol ; 77(18): 2263-2273, 2021 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-33958122

RESUMEN

BACKGROUND: Permanent pacemaker implantation (PPI) remains one of the main drawbacks of transcatheter aortic valve replacement (TAVR), but scarce data exist on PPI after valve-in-valve (ViV) TAVR, particularly with the use of newer-generation transcatheter heart valves (THVs). OBJECTIVES: The goal of this study was to determine the incidence, factors associated with, and clinical impact of PPI in a large series of ViV-TAVR procedures. METHODS: Data were obtained from the multicenter VIVID Registry and included the main baseline and procedural characteristics, in-hospital and late (median follow-up: 13 months [interquartile range: 3 to 41 months]) outcomes analyzed according to the need of periprocedural PPI. All THVs except CoreValve, Cribier-Edwards, Sapien, and Sapien XT were considered to be new-generation THVs. RESULTS: A total of 1,987 patients without prior PPI undergoing ViV-TAVR from 2007 to 2020 were included. Of these, 128 patients (6.4%) had PPI after TAVR, with a significant decrease in the incidence of PPI with the use of new-generation THVs (4.7% vs. 7.4%; p = 0.017), mainly related to a reduced PPI rate with the Evolut R/Pro versus CoreValve (3.7% vs. 9.0%; p = 0.002). There were no significant differences in PPI rates between newer-generation balloon- and self-expanding THVs (6.1% vs. 3.9%; p = 0.18). In the multivariable analysis, older age (odds ratio [OR]: 1.05 for each increase of 1 year; 95% confidence interval [CI]: 1.02 to 1.07; p = 0.001), larger THV size (OR: 1.10; 95% CI: 1.01 to 1.20; p = 0.02), and previous right bundle branch block (OR: 2.04; 95% CI: 1.00 to 4.17; p = 0.05) were associated with an increased risk of PPI. There were no differences in 30-day mortality between the PPI (4.7%) and no-PPI (2.7%) groups (p = 0.19), but PPI patients exhibited a trend toward higher mortality risk at follow-up (hazard ratio: 1.39; 95% CI: 1.02 to 1.91; p = 0.04; p = 0.08 after adjusting for age differences between groups). CONCLUSIONS: In a contemporary large series of ViV-TAVR patients, the rate of periprocedural PPI was relatively low, and its incidence decreased with the use of new-generation THV systems. PPI following ViV-TAVR was associated with a trend toward increased mortality at follow-up.


Asunto(s)
Marcapaso Artificial , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Implantación de Prótesis , Sistema de Registros
13.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 31-36, 2021 12.
Artículo en Italiano | MEDLINE | ID: mdl-35343489

RESUMEN

In the last decades, the wide use of surgical aortic bioprostheses translated into an increased rate of valve degeneration and dysfunction. However, most patients are excluded from surgical re-do due to high or prohibitive operative risk. In this clinical context, valve-in-valve transcatheter aortic valve implantation (ViV-TAVI) has been shown to be effective. Nevertheless, some relevant concerns, such as elevated residual transvalvular gradient and coronary artery obstruction, still remain. Detailed information regarding the degenerated surgical bioprosthesis and a thorough analysis of the computed tomography scan are essential for accurate pre-procedural planning and may avoid dramatic acute complications. Moreover, in difficult cases, the use of some tips and tricks may help expert operators to achieve better results.Here we report the case of a patient affected by structural degeneration of a small label size surgical aortic valve, who was excluded from surgical reintervention due to high operative risk. Therefore, we decided to perform a ViV-TAVI despite the presence of challenging features.


Asunto(s)
Bioprótesis , Prótesis Valvulares Cardíacas , Válvula Aórtica/cirugía , Humanos , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
14.
G Ital Cardiol (Rome) ; 22(12 Suppl 2): 37-41, 2021 12.
Artículo en Italiano | MEDLINE | ID: mdl-35343490

RESUMEN

Coronary artery disease is a frequent comorbidity in patients with severe aortic stenosis undergoing trans-catheter aortic valve implantation (TAVI) and the need to ensure coronary access after TAVI is fundamental. This aspect is becoming increasingly relevant as TAVI indication expand to younger and lower-risk patients. Moreover, the longer life expectancy of subjects who are currently treated with TAVI could result in an increased need for TAVI-in-TAVI due to valve degeneration. As the implantation of a second transcatheter bioprosthesis might impair coronary access, TAVI-in-TAVI will be unfeasible in a significant proportion of cases, particularly if they received a tall-frame transcatheter heart valve at the time of the first intervention. Thus, patients might experience the paradox of needing surgical aortic valve replacement when they are older and frailer. Here we report the case of a patient with history of coronary artery disease and severe aortic stenosis treated with TAVI, presenting with an acute coronary syndrome 8 years after percutaneous aortic valve implantation. Thanks to the low frame height of the transcatheter aortic valve, it was possible to easily perform coronary angiography and high-risk percutaneous coronary intervention using hemodynamic support device (Impella CP). Moreover, this case highlights how the implantation of a low-frame transcatheter prosthesis can increase the possibility of achieving coronary access even after TAVI-in-TAVI, if needed.


Asunto(s)
Estenosis de la Válvula Aórtica , Intervención Coronaria Percutánea , Reemplazo de la Válvula Aórtica Transcatéter , Estenosis de la Válvula Aórtica/cirugía , Angiografía Coronaria , Hemodinámica , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos
15.
Circulation ; 143(2): 104-116, 2021 01 12.
Artículo en Inglés | MEDLINE | ID: mdl-32975133

RESUMEN

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/cirugía , Prótesis Valvulares Cardíacas/normas , Válvula Mitral/cirugía , Sistema de Registros , Reoperación/normas , Reemplazo de la Válvula Aórtica Transcatéter/normas , Anciano , Anciano de 80 o más Años , Femenino , Estudios de Seguimiento , Enfermedades de las Válvulas Cardíacas/diagnóstico por imagen , Prótesis Valvulares Cardíacas/tendencias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Implantación de Prótesis de Válvulas Cardíacas/tendencias , Humanos , Internacionalidad , Masculino , Persona de Mediana Edad , Válvula Mitral/diagnóstico por imagen , Reoperación/tendencias , Estudios Retrospectivos , Reemplazo de la Válvula Aórtica Transcatéter/tendencias
16.
J Am Heart Assoc ; 9(13): e016446, 2020 07 07.
Artículo en Inglés | MEDLINE | ID: mdl-32578484

RESUMEN

Background Transcatheter aortic valve replacement (TAVR)-in-TAVR is a possible treatment for transcatheter heart valve (THV) degeneration. However, the displaced leaflets of the first THV will create a risk plane (RP) under which the passage of a coronary catheter will be impossible. The aim of our study was to evaluate the potential risk of impaired coronary access (CA) after TAVR-in-TAVR. Methods and Results We prospectively performed coronary angiography after TAVR with different THVs in 137 consecutive patients, looking where the catheter crossed the valve frame. If coronary cannulation was achieved from below the RP, the distance between valve frame and aortic wall was measured by aortic angiography. CA after TAVR-in-TAVR was defined as feasible if the catheter passed above the RP, as theoretically feasible if passed under the RP with valve-to-aorta distance >2 mm, and as unfeasible if passed under the RP with valve-to-aorta distance ≤2 mm. Seventy-two patients (53%) received a Sapien 3 THV, 26 (19%) received an Evolut Pro/R THV, and 39 (28%) received an Acurate Neo THV. CA after TAVR-in-TAVR was considered feasible in 40.9% (68.1%, 19.2%, and 5.1%, respectively; P<0.001), theoretically feasible in 27.7% (8.3%, 42.3%, and 53.8%, respectively; P<0.001), and unfeasible in 31.4% (23.6%, 38.5%, and 41.1%, respectively; P=0.116). Independent predictors of impaired CA after TAVR-in-TAVR were female sex (odds ratio [OR], 3.99; 95% CI, 1.07-14.86; P=0.040), sinotubular junction diameter (OR, 0.62; 95% CI, 0.48-0.80; P<0.001), and implantation of a supra-annular THV (OR, 6.61; 95% CI, 1.98-22.03; P=0.002). Conclusions CA after TAVR-in-TAVR might be unfeasible in >30% of patients currently treated with TAVR. Patients with a small sinotubular junction and those who received a supra-annular THV are at highest risk of potential CA impairment with TAVR-in-TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Cateterismo Cardíaco , Angiografía Coronaria , Vasos Coronarios/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Anciano , Anciano de 80 o más Años , Cateterismo Cardíaco/instrumentación , Catéteres Cardíacos , Estudios de Factibilidad , Femenino , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Humanos , Masculino , Valor Predictivo de las Pruebas , Estudios Prospectivos , Diseño de Prótesis , Medición de Riesgo , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
17.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32592401

RESUMEN

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Asunto(s)
Estenosis de la Válvula Aórtica , Bioprótesis , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Femenino , Humanos , Masculino , Diseño de Prótesis , Falla de Prótesis , Resultado del Tratamiento
19.
Monaldi Arch Chest Dis ; 90(1)2020 Mar 12.
Artículo en Inglés | MEDLINE | ID: mdl-32162894

RESUMEN

Left ventricular pseudoaneurysms (LVP) are rare but may arise after myocardial infarction, trauma or cardiac surgery, tending to expand and rupture over the time. We show the case of a 75-year-old patient with a recurrent giant ventricular pseudoaneurysm, who presented to the emergency department with sustained ventricular tachycardia. Pseudoaneurysmatic lesion was investigated through echocardiography, angiography and Cardiac Computed Tomography, in order to evaluate the size and spatial orientation of the pseudoaneurysm and to set a tailored treatment. At emergency department, sustained ventricular tachycardia may be the first and unique clinical presentation of ventricular pseudoaneurysm late recurrence, whose management requires a multimodality imaging approach to guide surgical correction.


Asunto(s)
Aneurisma Falso , Ventrículos Cardíacos , Taquicardia Ventricular/etiología , Anciano , Aneurisma Falso/complicaciones , Aneurisma Falso/diagnóstico por imagen , Angiografía , Procedimientos Quirúrgicos Cardíacos , Ecocardiografía , Aneurisma Cardíaco , Ventrículos Cardíacos/diagnóstico por imagen , Humanos , Masculino , Recurrencia , Tomografía Computarizada por Rayos X
20.
Int J Cardiol ; 298: 76-82, 2020 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-31575495

RESUMEN

BACKGROUND: Subjects with bicuspid aortic valve (BAV) have been excluded from transcatheter aortic valve replacement (TAVR) randomized trials. METHODS: With this meta-analysis of observational studies we first compared TAVR outcomes of BAV vs. tricuspid aortic valve (TAV) patients, stratifying the results by device generation. Then, we looked for differences between balloon-expandable (BE) and self-expandable (SE) bioprostheses in BAV patients. Primary outcome was 30-day mortality. Secondary outcomes were 30-day stroke, moderate-severe paravalvular leakage, new pacemaker implantation, vascular complications and 1-year mortality. RESULTS: Thirteen studies (11,032 patients, 7291 TAV and 3741 BAV) and seven studies (706 patients, 367 treated with BE, 339 with SE valve) met inclusion criteria. Thirty-day (OR = 1.13; 95% CI 0.88-1.46, p = 0.33) and 1-year mortality (OR = 1.02; 95% CI 0.77-1.37, p = 0.87) were similar between patients receiving TAVR for BAV or TAV. Subjects treated for BAV were at higher risk of conversion to conventional surgery (OR = 2.35; 95% CI 1.30-4.23, p = 0.005), implantation of a second valve (OR = 2.06; 95% CI 1.31-3.25; p = 0.002), moderate/severe paravalvular leakage (PVL) (OR = 1.67; 95% CI 1.29-2.17; p = 0.0001) and device failure (OR = 1.26; 95% CI 1.02-1.56; p = 0.04). Rates of adverse events decreased significantly with the use of new-generation devices, but outcome differences remained consistent. BAV patients treated with BE vs. SE valves had similar 30-day and 1-year mortality, stroke and moderate-severe PVL. Balloon-expandable valves were associated with lower rates of a second valve and new pacemaker implantation but carried higher risk of annular rupture. CONCLUSIONS: BAV patients treated with TAVR had similar 30-day and 1-year mortality as well as stroke and new pacemaker implantation rates compared to TAV subjects, but carried higher risk of moderate/severe PVL, conversion to surgery and device failure. Event rates significantly decreased with the use of new-generation devices, but TAVR still showed better procedural results in TAV compared to BAV.


Asunto(s)
Estenosis de la Válvula Aórtica/cirugía , Válvula Aórtica/anomalías , Bioprótesis/tendencias , Enfermedades de las Válvulas Cardíacas/cirugía , Reemplazo de la Válvula Aórtica Transcatéter/tendencias , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Enfermedad de la Válvula Aórtica Bicúspide , Enfermedades de las Válvulas Cardíacas/mortalidad , Humanos , Estudios Observacionales como Asunto/métodos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...