Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 29
Filtrar
2.
Radiographics ; 43(12): e230073, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37917537

RESUMEN

Advances in MRI technology have led to the development of low-field-strength (hereafter, "low-field") (0.55 T) MRI systems with lower weight, fewer shielding requirements, and lower cost than those of traditional (1.5-3 T) systems. The trade-offs of lower signal-to-noise ratio (SNR) at 0.55 T are partially offset by patient safety and potential comfort advantages (eg, lower specific absorption rate and a more cost-effective larger bore diameter) and physical advantages (eg, decreased T2* decay, shorter T1 relaxation times). Image reconstruction advances leveraging developing technologies (such as deep learning-based denoising) can be paired with traditional techniques (such as increasing the number of signal averages) to improve SNR. The overall image quality produced by low-field MRI systems, although perhaps somewhat inferior to 1.5-3 T MRI systems in terms of SNR, is nevertheless diagnostic for a broad variety of body imaging applications. Effective low-field body MRI requires (a) an understanding of the trade-offs resulting from lower field strengths, (b) an approach to modifying routine sequences to overcome SNR challenges, and (c) a workflow for carefully selecting appropriate patients. The authors describe the rationale, opportunities, and challenges of low-field body MRI; discuss important considerations for low-field imaging with common body MRI sequences; and delineate a variety of use cases for low-field body MRI. The authors also include lessons learned from their preliminary experience with a new low-field MRI system at a tertiary care center. Finally, they explore the future of low-field MRI, summarizing current limitations and potential future developments that may enhance the clinical adoption of this technology. ©RSNA, 2023 Supplemental material is available for this article. Quiz questions for this article are available through the Online Learning Center. See the invited commentary by Venkatesh in this issue.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Seguridad del Paciente
3.
J Magn Reson Imaging ; 55(6): 1890-1899, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-34704644

RESUMEN

BACKGROUND: Although studies have described factors associated with failed magnetic resonance elastography (MRE), little is known about what factors influence usable elastography data. PURPOSE: To identify factors that have a negative impact on percent measurable liver volume (pMLV), defined as the proportion of usable liver elastography data relative to the volume of imaged liver in patients undergoing MRE. STUDY TYPE: Retrospective. SUBJECTS: A total of 264 patients (n = 132 males, n = 132 females; mean age = 57 years) with suspected or known chronic liver disease underwent MRE paired with a liver protocol MRI. FIELD STRENGTH/SEQUENCE: MRE was performed on a single 1.5 T scanner using a two-dimensional gradient-recalled echo phase-contrast sequence with a passive acoustic driver overlying the right hemiliver. ASSESSMENT: Stiffness maps (usable data at 95% confidence) and liver contours on magnitude images of the MRE acquisition were manually traced and used to assess mean stiffness and pMLV. Hepatic fat fraction and R2 * values were also calculated. The distance from the acoustic wave generator on the skin surface to the liver edge was measured. Two radiologists performed the MR analyses with 50 overlapping cases for inter-reader analysis. STATISTICAL TESTS: Linear regression was performed to identify factors significantly associated with pMLV. Intraclass correlation was performed for inter-reader reliability. RESULTS: pMLV was 31% ± 20% (range 0%-86%). Complete MRE failure (i.e. pMLV = 0%) occurred in 10 patients (4%). Multivariate linear regression identified higher hepatic fat fraction, R2 *, BMI, and driver-to-liver surface distance; male sex; and lower mean liver stiffness was significantly independently associated with lower pMLV. Intraclass correlation for pMLV was 0.96, suggestive of excellent reliability. DATA CONCLUSION: Higher fat fraction, R2 *, BMI, driver-to-liver surface distance, male sex, and lower mean liver stiffness were associated with lower pMLV. Optimization of image acquisition parameters and driver placement may improve MRE quality, and pMLV likely serves as a diagnostic utility quality control metric. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Diagnóstico por Imagen de Elasticidad/métodos , Femenino , Humanos , Hígado/diagnóstico por imagen , Hígado/patología , Cirrosis Hepática/patología , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Control de Calidad , Reproducibilidad de los Resultados , Estudios Retrospectivos
4.
AJR Am J Roentgenol ; 216(5): 1229-1239, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33729883

RESUMEN

OBJECTIVE. The purpose of this article was to assess the reliability and accuracy of hepatic periportal space widening and other qualitative imaging features for the prediction of hepatic fibrosis. MATERIALS AND METHODS. This single-center retrospective study identified consecutive patients who had undergone liver MR elastography. Two abdominal radiologists independently reviewed anatomic images, assessing multiple qualitative features of chronic liver disease (CLD) including periportal space widening. Each reader also measured the periportal space at the main portal vein (MPV) and right portal vein (RPV). Interrater reliability analysis was then performed. Sensitivity and specificity were determined for the detection of any hepatic fibrosis (stage I or higher) and of advanced fibrosis (stage III or higher) using stiffness on MR elastography as the reference standard. RESULTS. Of 229 subjects, 157 (69%) had fibrosis and 78 (34%) had advanced fibrosis. Agreement for periportal space widening was moderate (κ = 0.47), and agreement for remaining features was moderate to substantial (κ = 0.42-0.80). Agreement for the periportal space at the MPV was moderate (ICC, 0.55), and agreement for the periportal space at the RPV was near perfect (ICC, 0.83). Periportal space widening had the highest sensitivity (83.0%) for any fibrosis, with limited specificity (61.3%). Surface nodularity had the highest specificity (94.4%) for any fibrosis, with limited sensitivity (51.6%). Periportal space widening plus one or more additional imaging feature of CLD or the presence of surface nodularity alone had sensitivity of 72.6% and specificity of 76.1%. A periportal space at the MPV greater than 9.5 mm had substantial agreement with qualitative periportal space widening (κ = 0.74). CONCLUSION. Periportal space widening has a high sensitivity for hepatic fibrosis, with moderate specificity when combined with additional anatomic features of CLD.


Asunto(s)
Cirrosis Hepática/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores , Femenino , Humanos , Hígado/diagnóstico por imagen , Masculino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Estudios Retrospectivos , Sensibilidad y Especificidad , Adulto Joven
5.
J Digit Imaging ; 33(1): 143-150, 2020 02.
Artículo en Inglés | MEDLINE | ID: mdl-31292770

RESUMEN

Scheduling of CT and MR exams requires reasonable estimates for expected scan duration. However, scan-time variability and efficiency gains from combining multiple exams are not quantitatively well characterized. In this work, we developed an informatics approach to quantify typical duration, duration variability, and multiple-procedure efficiency on a large scale, and used the approach to analyze 48,766 CT- and MR-based neuroradiological exams performed over one year. We found MR exam durations demonstrated higher absolute variability, but lower relative variability and lower multiple-procedure efficiency, compared to CT exams (p < 0.001). Our approach enables quantification of real-world operational performance and variability to inform optimal patient scheduling, efficient resource utilization, and sustainable service planning.


Asunto(s)
Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Estudios Transversales , Humanos , Cintigrafía
6.
J Radiol Case Rep ; 13(3): 19-27, 2019 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31565174

RESUMEN

Spontaneous rupture of the inferior vena cava (IVC) is a rare entity. We report a case of a spontaneous IVC rupture associated with IVC filter thrombosis in a patient presenting with severe atraumatic back pain. Computed tomography (CT) identified a retroperitoneal hematoma and suggested IVC thrombosis. Magnetic resonance (MR) imaging confirmed the presence of IVC filter thrombosis and demonstrated a large defect in the infrarenal IVC, with the vessel lumen in free communication with the adjacent hematoma. The patient was managed conservatively and discharged in stable condition. MR imaging played an important role in characterizing the CT findings, which were unclear.


Asunto(s)
Rotura Espontánea/diagnóstico por imagen , Rotura Espontánea/etiología , Filtros de Vena Cava/efectos adversos , Vena Cava Inferior/diagnóstico por imagen , Trombosis de la Vena/terapia , Tratamiento Conservador , Hematoma/complicaciones , Hematoma/diagnóstico por imagen , Hematoma/terapia , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Espacio Retroperitoneal/diagnóstico por imagen , Rotura Espontánea/terapia , Tomografía Computarizada por Rayos X , Resultado del Tratamiento , Trombosis de la Vena/complicaciones , Trombosis de la Vena/diagnóstico por imagen
7.
AJR Am J Roentgenol ; 211(6): 1264-1272, 2018 12.
Artículo en Inglés | MEDLINE | ID: mdl-30247982

RESUMEN

OBJECTIVE: Tertiary care practices increasingly provide second-opinion consultations on reports from outside practices or institutions. This practice of providing a second opinion has been studied in a variety of subspecialties; however, its potential effect on the management of hepatopancreaticobiliary (HPB) disease is not known. The purpose of this study was to assess the rate of significant discrepancies between the initial report and the consultation report, the source of discrepancies, and the frequency of repeat imaging recommendations. MATERIALS AND METHODS: Retrospective chart review was performed for 480 consecutive CT and MRI consultation reports interpreted between January 2014 and December 2015 for patients with HPB diseases whose initial CT and MRI reports were generated at outside facilities. The initial report and the consultation report were independently reviewed and compared by two abdominal radiologists. Discrepancies between the initial report and the consultation report were divided into minor and major differences in the detection or interpretation of abnormalities. Clinical importance was defined as a change in a finding or interpretation that directly impacted management of the patient. RESULTS: A major discrepancy between the reports was identified in 27-28% of cases split evenly between detection and interpretation of abnormalities. Interreader agreement for categorization was moderate (weighted kappa value, 0.49). In consensus review, the rate of a major discrepancy occurring increased to 32%. Common sources of discrepancy were interpretation of findings as malignant versus benign (49% of cases) and accuracy of staging (15% of cases). Imaging limitations were described in 16% of cases, commonly as a result of an insufficient protocol or poor image quality. CONCLUSION: Discrepancies in interpretation resulting in direct implications for clinical management are seen in almost one-third of HPB consultation cases. Second-opinion imaging consultation in the tertiary care setting can frequently impact management.


Asunto(s)
Enfermedades del Sistema Digestivo/diagnóstico por imagen , Imagen por Resonancia Magnética , Derivación y Consulta , Tomografía Computarizada por Rayos X , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Estudios Retrospectivos , Adulto Joven
8.
HPB (Oxford) ; 19(2): 133-139, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27916436

RESUMEN

BACKGROUND & OBJECTIVES: Multidisciplinary tumor boards (MDTBs) are frequently employed in cancer centers but their value has been debated. We reviewed the decision-making process and resource utilization of our MDTB to assess its utility in the management of pancreatic and upper gastrointestinal tract conditions. METHODS: A prospectively-collected database was reviewed over a 12-month period. The primary outcome was change in management plan as a result of case discussion. Secondary outcomes included resources required to hold MDTB, survival, and adherence to treatment guidelines. RESULTS: Four hundred seventy cases were reviewed. MDTB resulted in a change in the proposed plan of management in 101 of 402 evaluable cases (25.1%). New plans favored obtaining additional diagnostic workup. No recorded variables were associated with a change in plan. For newly-diagnosed cases of pancreatic ductal adenocarcinoma (n = 33), survival time was not impacted by MDTB (p = .154) and adherence to National Comprehensive Cancer Network guidelines was 100%. The estimated cost of physician time per case reviewed was $190. CONCLUSIONS: Our MDTB influences treatment decisions in a sizeable number of cases with excellent adherence to national guidelines. However, this requires significant time expenditure and may not impact outcomes. Regular assessments of the effectiveness of MDTBs should be undertaken.


Asunto(s)
Carcinoma Ductal Pancreático/terapia , Toma de Decisiones Clínicas , Prestación Integrada de Atención de Salud/estadística & datos numéricos , Neoplasias Gastrointestinales/terapia , Recursos en Salud/estadística & datos numéricos , Comunicación Interdisciplinaria , Neoplasias Pancreáticas/terapia , Grupo de Atención al Paciente/estadística & datos numéricos , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Carcinoma Ductal Pancreático/economía , Carcinoma Ductal Pancreático/mortalidad , Carcinoma Ductal Pancreático/patología , Bases de Datos Factuales , Prestación Integrada de Atención de Salud/economía , Prestación Integrada de Atención de Salud/normas , Femenino , Neoplasias Gastrointestinales/economía , Neoplasias Gastrointestinales/mortalidad , Neoplasias Gastrointestinales/patología , Adhesión a Directriz , Costos de la Atención en Salud , Recursos en Salud/economía , Recursos en Salud/normas , Humanos , Masculino , Persona de Mediana Edad , Neoplasias Pancreáticas/economía , Neoplasias Pancreáticas/mortalidad , Neoplasias Pancreáticas/patología , Grupo de Atención al Paciente/economía , Grupo de Atención al Paciente/normas , Guías de Práctica Clínica como Asunto , Resultado del Tratamiento , Adulto Joven
9.
Cardiovasc Intervent Radiol ; 39(6): 940-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-26721588

RESUMEN

Primary aortic neoplasms are rare. Aortic sarcoma arising after endovascular aneurysm repair (EVAR) is a scarce subset of primary aortic malignancies, reports of which are infrequent in the published literature. The diagnosis of aortic sarcoma is challenging due to its non-specific clinical presentation, and the prognosis is poor due to delayed diagnosis, rapid proliferation, and propensity for metastasis. Post-EVAR, aortic sarcomas may mimic other more common aortic processes on surveillance imaging. Radiologists are rarely knowledgeable about this rare entity for which multimodality imaging and awareness are invaluable in early diagnosis. A series of three pathologically confirmed cases are presented to display the multimodality imaging features and clinical presentations of aortic sarcoma arising after EVAR.


Asunto(s)
Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Hemangiosarcoma/diagnóstico por imagen , Leiomiosarcoma/diagnóstico por imagen , Imagen Multimodal , Complicaciones Posoperatorias/diagnóstico , Neoplasias Vasculares/diagnóstico por imagen , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aortografía , Angiografía por Tomografía Computarizada , Diagnóstico Diferencial , Femenino , Humanos , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X
11.
J Digit Imaging ; 27(4): 486-95, 2014 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-24744278

RESUMEN

Picture archiving and communication systems (PACS) play a critical role in radiology. This paper presents the criteria important to PACS administrators for selecting a PACS. A set of criteria are identified and organized into an integrative hierarchical framework. Survey responses from 48 administrators are used to identify the relative weights of these criteria through an analytical hierarchy process. The five main dimensions for PACS selection in order of importance are system continuity and functionality, system performance and architecture, user interface for workflow management, user interface for image manipulation, and display quality. Among the subdimensions, the highest weights were assessed for security, backup, and continuity; tools for continuous performance monitoring; support for multispecialty images; and voice recognition/transcription. PACS administrators' preferences were generally in line with that of previously reported results for radiologists. Both groups assigned the highest priority to ensuring business continuity and preventing loss of data through features such as security, backup, downtime prevention, and tools for continuous PACS performance monitoring. PACS administrators' next high priorities were support for multispecialty images, image retrieval speeds from short-term and long-term storage, real-time monitoring, and architectural issues of compatibility and integration with other products. Thus, next to ensuring business continuity, administrators' focus was on issues that impact their ability to deliver services and support. On the other hand, radiologists gave high priorities to voice recognition, transcription, and reporting; structured reporting; and convenience and responsiveness in manipulation of images. Thus, radiologists' focus appears to be on issues that may impact their productivity, effort, and accuracy.


Asunto(s)
Sistemas de Información Radiológica/normas , Presentación de Datos/normas , Humanos , Interfaz Usuario-Computador , Flujo de Trabajo
12.
J Magn Reson Imaging ; 39(2): 259-68, 2014 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-24436150

RESUMEN

The purpose of this article is to introduce the underlying challenges associated with the incorporation of magnetic resonance imaging (MRI) into the new hybrid imaging modality simultaneous positron emission tomography (PET)/MR and their impact on attenuation correction, sequence optimization, and protocol development. Many adjustments to MR sequences are necessary for optimal whole-body and fused image results.


Asunto(s)
Artefactos , Aumento de la Imagen/métodos , Interpretación de Imagen Asistida por Computador/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones/métodos , Imagen de Cuerpo Entero/métodos , Algoritmos , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Procesamiento de Señales Asistido por Computador
13.
Abdom Imaging ; 39(2): 310-22, 2014 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-24407728

RESUMEN

Combined hepatocellular-cholangiocarcinoma (CHC), also referred to as primary liver carcinoma (PLC) with biphenotypic differentiation, is an increasingly recognized subtype of malignant PLC encompassing varying morphologic forms thought to arise either from progenitor cell lineage or dedifferentiation of mature liver cells. Tumor cells express both biliary and hepatocellular markers by immunohistochemistry, and may also express progenitor cell and stem cell markers. Due to the relative rarity of this tumor type, little is known about the risk factors, imaging appearance, or prognosis. Few studies have demonstrated risk factors that overlap with hepatocellular carcinoma (HCC) and cholangiocarcinoma (CC), though not all appear to arise in the background of cirrhosis. The imaging appearances of these tumors may overlap with those of HCC and CC and discriminating features such as classic enhancement patterns and biliary ductal dilation are not universally present. Serum tumor markers, such as alpha-fetoprotein and carbohydrate antigen 19-9, may be helpful when they are discordant with imaging or if both are elevated to a significant degree. In regards to management and prognosis, most studies demonstrate worse outcomes compared with HCC or CC. In the United States, the diagnosis of HCC is frequently made with imaging alone, and subsequent management decisions, including organ allocation for transplantation, rely upon the radiological diagnosis. Given the importance of radiological diagnosis, awareness of this tumor type is essential for appropriate management.


Asunto(s)
Neoplasias de los Conductos Biliares/patología , Conductos Biliares Intrahepáticos/patología , Carcinoma Hepatocelular/patología , Colangiocarcinoma/patología , Cirrosis Hepática/patología , Neoplasias Hepáticas/patología , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Neoplasias de los Conductos Biliares/terapia , Biomarcadores de Tumor/metabolismo , Carcinoma Hepatocelular/terapia , Colangiocarcinoma/terapia , Medios de Contraste , Femenino , Gadolinio DTPA , Humanos , Cirrosis Hepática/terapia , Neoplasias Hepáticas/terapia , Masculino , Meglumina/análogos & derivados , Persona de Mediana Edad , Compuestos Organometálicos , Fenotipo , Factores de Riesgo
15.
J Magn Reson Imaging ; 37(2): 431-4, 2013 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-23023940

RESUMEN

PURPOSE: To compare [(18)F]fluorodeoxyglucose (FDG)/positron emission tomography (PET)/computed tomography (CT) and magnetic resonance imaging (MRI) for evaluating patients with cervical cancer. We compared tumor characteristics on FDG-PET and apparent diffusion coefficient (ADC) maps on diffusion-weighted MRI (DWI) to evaluate concordance of two functional imaging techniques. MATERIALS AND METHODS: Twenty women with cervical cancer underwent pretreatment FDG-PET/CT and pelvic MRI. Images were rigidly fused by pelvic anatomy using coregistration software. Tumor contours on PET images were generated by autosegmentation of the region containing at least 40% of the maximum standardized uptake value (SUV). DWI contours were generated by manual segmentation. Tumor volume similarity was evaluated using the [PET]/[ADC] volume proportion, Dice's coefficient, and the mean SUV isothreshold at the surface of each ADC contour. Tumor subvolume similarity was evaluated with analysis of variance (ANOVA). RESULTS: The [PET]/[ADC] volume proportion was 0.88 ± 0.14. Dice's coefficient between PET and ADC tumor contours was 0.76 ± 0.06. The mean SUV isothreshold at the ADC-delineated tumor surface was 34 ± 4%. Subvolumes with increased metabolic activity on FDG-PET also had more restricted diffusion on DWI (P < 0.0001, ANOVA). CONCLUSION: Concordance of functional imaging was observed between FDG-PET and DWI for cervical cancer. Tumor subvolumes with increased metabolic activity on FDG-PET also have greater cell density by DWI.


Asunto(s)
Carcinoma de Células Escamosas/diagnóstico , Fluorodesoxiglucosa F18 , Interpretación de Imagen Asistida por Computador/métodos , Imagenología Tridimensional/métodos , Imagen por Resonancia Magnética/métodos , Imagen Multimodal/métodos , Tomografía de Emisión de Positrones , Tomografía Computarizada por Rayos X , Neoplasias del Cuello Uterino/diagnóstico , Adulto , Anciano , Anciano de 80 o más Años , Algoritmos , Femenino , Humanos , Aumento de la Imagen/métodos , Persona de Mediana Edad , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Carga Tumoral
16.
J Am Coll Radiol ; 9(9): 613-9, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22954541

RESUMEN

Upper-extremity venous thrombosis often presents as unilateral arm swelling. The differential diagnosis includes lesions compressing the veins and causing a functional venous obstruction, venous stenosis, an infection causing edema, obstruction of previously functioning lymphatics, or the absence of sufficient lymphatic channels to ensure effective drainage. The following recommendations are made with the understanding that venous disease, specifically venous thrombosis, is the primary diagnosis to be excluded or confirmed in a patient presenting with unilateral upper-extremity swelling. Contrast venography remains the best reference-standard diagnostic test for suspected upper-extremity acute venous thrombosis and may be needed whenever other noninvasive strategies fail to adequately image the upper-extremity veins. Duplex, color flow, and compression ultrasound have also established a clear role in evaluation of the more peripheral veins that are accessible to sonography. Gadolinium contrast-enhanced MRI is routinely used to evaluate the status of the central veins. Delayed CT venography can often be used to confirm or exclude more central vein venous thrombi, although substantial contrast loads are required. The ACR Appropriateness Criteria(®) are evidence-based guidelines for specific clinical conditions that are reviewed every 2 years by a multidisciplinary expert panel. The guideline development and review include an extensive analysis of current medical literature from peer-reviewed journals and the application of a well-established consensus methodology (modified Delphi) to rate the appropriateness of imaging and treatment procedures by the panel. In those instances in which evidence is lacking or not definitive, expert opinion may be used to recommend imaging or treatment.


Asunto(s)
Diagnóstico por Imagen/normas , Trombosis Venosa Profunda de la Extremidad Superior/diagnóstico , Medios de Contraste , Diagnóstico Diferencial , Medicina Basada en la Evidencia , Humanos , Extremidad Superior/irrigación sanguínea
17.
Radiographics ; 32(5): 1445-60; discussion 1460-2, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22977029

RESUMEN

Because of its lack of ionizing radiation and excellent soft-tissue contrast, magnetic resonance (MR) imaging is being increasingly used in the evaluation of acute abdominal pain in the pregnant patient. Roughly 2% of all pregnancies are ectopic. Although ectopic pregnancy is usually diagnosed on the basis of a combination of clinical, laboratory, and ultrasonographic findings, it occasionally is initially identified at MR imaging. Thus, it is imperative that the radiologist should be familiar with the variable appearance of ectopic pregnancy at MR imaging and should evaluate for ectopic pregnancy at any time when (a) a patient has positive results of a pregnancy test and (b) an intrauterine pregnancy is not definitively seen. Because of potential issues of fetal safety, a conservative approach should be used for MR imaging in pregnancy. An MR imaging protocol for the evaluation of possible appendicitis in pregnant women is detailed. Specific findings that can aid in the diagnosis of ectopic pregnancy are the lack of an intrauterine pregnancy, isolated hemoperitoneum, tubal masses, hematosalpinx, and interstitial masses. In the differential diagnosis of acute abdominal pain in pregnancy, consideration should be given to the more unusual forms of ectopic pregnancy, such as angular pregnancy, cornual pregnancy, and abdominal pregnancy. Potential mimics of ectopic pregnancy include placental abnormalities, ovarian neoplasms, and corpus luteum cysts.


Asunto(s)
Aumento de la Imagen/métodos , Imagen por Resonancia Magnética/métodos , Embarazo Ectópico/patología , Diagnóstico Prenatal/métodos , Adolescente , Adulto , Femenino , Humanos , Embarazo , Adulto Joven
18.
Radiology ; 265(1): 151-7, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22798224

RESUMEN

PURPOSE: To determine which measurement of donor renal size on computed tomographic (CT) angiograms has the greatest correlation with renal function preoperatively in the donor and postoperatively in the transplant recipient. MATERIALS AND METHODS: Informed consent was waived for this retrospective HIPAA-compliant study approved by the institutional review board. Renal length, total volume, and cortical volume were measured on renal donor CT angiograms in 111 patients. Preoperative serum creatinine values for donors and postoperative creatinine values for recipients at hospital discharge and 6, 12, 24, and 36 months after transplant were collected, and estimated glomerular filtration rate (eGFR) was calculated. Correlation coefficients with 95% confidence intervals (CIs) were obtained for renal measures and donor eGFR and for renal measures adjusted to recipient body habitus and posttransplant creatinine level in the recipient. Thresholds were set for adjusted length and volumes, and the odds ratio (OR) for creatinine level less than 1.5 mg/dL at 36 months was calculated. RESULTS: Renal volumes and length were correlated with donor eGFR (r=0.58 [95% CI: 0.44, 0.69] for cortical volume, 0.56 [95% CI: 0.42, 0.68] for total volume, and 0.43 [95% CI: 0.27, 0.57] for renal length). All three measures, adjusted to recipient body habitus, were correlated with recipient renal function from discharge (r=-0.41 to -0.43) up to 36 months after transplantation (r=-0.33 to -0.41). By using a threshold of 1.5 for cortical volume to recipient weight, 2.25 for total volume to recipient weight, and 0.175 for renal length to recipient weight, the odds of creatinine level greater than 1.5 mg/dL were four times as great for smaller kidney-to-recipient weight ratios, a statistically significant pattern for cortical volume (OR, 4.07; 95% CI: 1.10, 15.09) but not total volume (OR, 4.24; 95% CI: 0.90, 20.01) or renal length (OR, 4.08; 95% CI: 0.48-34.29). CONCLUSION: Renal length and volumes correlated with recipient renal function up to 36 months after transplant. A low ratio of cortical volume to recipient weight was associated with diminished renal function at 36 months after transplant.


Asunto(s)
Angiografía/métodos , Riñón/diagnóstico por imagen , Trasplante de Hígado , Tomografía Computarizada por Rayos X/métodos , Adolescente , Adulto , Anciano , Biomarcadores/sangre , Intervalos de Confianza , Creatinina/sangre , Femenino , Tasa de Filtración Glomerular , Humanos , Pruebas de Función Renal , Masculino , Persona de Mediana Edad , Nefrectomía , Tamaño de los Órganos , Interpretación de Imagen Radiográfica Asistida por Computador , Reproducibilidad de los Resultados , Estudios Retrospectivos
19.
Hepatology ; 54(6): 2227-37, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21932400

RESUMEN

This article is a review of magnetic resonance imaging (MRI) of incidental focal liver lesions. This review provides an overview of liver MRI protocol, diffusion-weighted imaging, and contrast agents. Additionally, the most commonly encountered benign and malignant lesions are discussed with emphasis on imaging appearance and the diagnostic performance of MRI based on a review of the literature.


Asunto(s)
Hepatopatías/diagnóstico , Hígado/patología , Imagen por Resonancia Magnética/métodos , Adenoma de Células Hepáticas/diagnóstico , Carcinoma Hepatocelular/diagnóstico , Colangiocarcinoma/diagnóstico , Medios de Contraste , Imagen de Difusión por Resonancia Magnética/métodos , Hiperplasia Nodular Focal/diagnóstico , Gadolinio DTPA , Hemangioma/diagnóstico , Hepatocitos/metabolismo , Humanos , Hallazgos Incidentales , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/secundario , Meglumina/análogos & derivados , Compuestos Organometálicos
20.
Dig Dis Sci ; 56(10): 2906-13, 2011 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-21688128

RESUMEN

BACKGROUND: Symptomatic Crohn's disease (CD) patients often undergo diagnostic imaging studies for evaluation of disease activity or complications including bowel strictures and obstruction. Magnetic resonance enterography (MRE) provides information regarding disease activity, chronicity, and stricture formation without using ionizing radiation. AIM: Examine the use of MRE among CD patients presenting with symptoms suggesting obstruction in a tertiary care practice setting. METHODS: We performed a retrospective study of all CD patients undergoing MRE at a tertiary IBD referral center over a 3-year study period including a subgroup analysis of patients presenting obstructive symptoms. Positive and negative findings from MRE were correlated with medical and surgical decision outcomes over the subsequent 90-day period. RESULTS: In the study, 119 CD patients underwent 133 MRE scans, including 40 scans on individuals presenting with obstructive symptoms. Positive findings of CD including active inflammation, stricturing, and penetrating disease were more frequent in MREs ordered to evaluate obstructive symptoms (87.5%) compared other indications (58.1%, p = 0.001). In patients presenting with obstructive symptoms, MRE findings assisted in directing a change of clinical management towards escalation of medical therapy in 55% and surgery in 32.5%. Review of surgical resection specimens corroborated MRE findings of disease activity and fibrosis in 92% of cases going to surgery. CONCLUSIONS: In practice-based use at a tertiary IBD referral center, MRE provided an effective, radiation-free alternative to computed tomography by providing valuable diagnostic information for evaluating and directing care in Crohn's disease, particularly for patients presenting with obstructive symptoms.


Asunto(s)
Enfermedad de Crohn/diagnóstico por imagen , Enfermedad de Crohn/patología , Imagen por Resonancia Magnética/métodos , Adolescente , Adulto , Anciano , Constricción Patológica/diagnóstico por imagen , Constricción Patológica/patología , Femenino , Humanos , Íleon/diagnóstico por imagen , Íleon/patología , Imagen por Resonancia Magnética/efectos adversos , Masculino , Persona de Mediana Edad , Radiografía , Estudios Retrospectivos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...