Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
Circ J ; 87(12): 1711-1719, 2023 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-37258224

RESUMEN

BACKGROUND: Pulmonary vein stenosis (PVS) after PV isolation (PVI) for atrial fibrillation (AF) is a severe complication that requires angioplasty. This study aimed to compare the reduction of the cross-sectional PV area (PVA) and the incidence of PVS after cryoballoon (CB)-PVI, hot balloon (HB)-PVI, or laser balloon (LB)-PVI.Methods and Results: A total of 320 patients who underwent an initial catheter ablation procedure for AF using a CB, HB, or LB in 2 hospitals were included. They underwent contrast-enhanced multidetector CT before and 3 months after the procedure. In all 4 PVs, the reduction in PVA was more significant in the LB group than in the CB or HB groups, respectively. Moderate (50-75%) and severe (>75%) PVS were observed in 5.3% and 0.5% of the PVs, respectively. Although moderate PVS was more frequently observed in the LB group than in the CB or HB groups (8.2%, 3.8%, and 5.0%; P=0.03), the incidence of severe PVS was similar in the LB, CB, and HB groups (0.3%, 0.5%, and 1.0%; P=0.46). Symptomatic PVS requiring intervention occurred in 1 (0.3%) patient. CONCLUSIONS: Although the reduction in cross-sectional PVA and the incidence of moderate PVS after LB-PVI was more significant than after CB-PVI or HB-PVI, it rarely led to severe PVS. Symptomatic PVS requiring intervention was rare after the balloon ablation of AF.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Estenosis de Vena Pulmonar , Humanos , Estenosis de Vena Pulmonar/diagnóstico por imagen , Estenosis de Vena Pulmonar/etiología , Estudios Transversales , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Rayos Láser
2.
BMJ Open ; 13(2): e068894, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36792334

RESUMEN

INTRODUCTION: Data are lacking on the extent to which patients with non-valvular atrial fibrillation (AF) who are aged ≥80 years benefit from ablation treatment. The question pertains especially to patients' postablation quality of life (QoL) and long-term clinical outcomes. METHODS AND ANALYSIS: We are initiating a prospective, registry-based, multicentre observational study that will include patients aged ≥80 years with non-valvular AF who choose to undergo treatment by catheter ablation and, for comparison, such patients who do not choose to undergo ablation (either according to their physician's advice or their own preference). Study subjects are to be enrolled from 52 participant hospitals and three clinics located throughout Japan from 1 June 2022 to 31 December 2023, and each will be followed up for 1 year. The planned sample size is 660, comprising 220 ablation group patients and 440 non-ablation group patients. The primary endpoint will be the composite incidence of stroke/transient ischaemic attack (TIA) or systemic embolism (SE), another cardiovascular event, major bleeding and/or death from any cause. Other clinical events such as postablation AF recurrence, a fall or bone fracture will be recorded. We will collect standard clinical background information plus each patient's Clinical Frailty Scale score, AF-related symptoms, QoL (Five-Level Version of EQ-5D) scores, Mini-Mental State Examination (optional) score and laboratory test results, including measures of nutritional status, on entry into the study and 1 year later, and serial changes in symptoms and QoL will also be secondary endpoints. Propensity score matching will be performed to account for covariates that could affect study results. ETHICS AND DISSEMINATION: The study conforms to the Declaration of Helsinki and the Ethical Guidelines for Clinical Studies issued by the Ministry of Health, Labour and Welfare, Japan. Results of the study will be published in one or more peer-reviewed journals. TRIAL REGISTRATION NUMBER: UMIN000047023.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Accidente Cerebrovascular , Anciano , Humanos , Fibrilación Atrial/epidemiología , Fibrilación Atrial/cirugía , Fibrilación Atrial/complicaciones , Calidad de Vida , Estudios Prospectivos , Esperanza de Vida Saludable , Factores de Riesgo , Accidente Cerebrovascular/etiología , Accidente Cerebrovascular/complicaciones , Sistema de Registros , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Resultado del Tratamiento
3.
J Cardiol Cases ; 27(1): 16-18, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36618840

RESUMEN

An 81-year-old woman with arrhythmogenic right ventricular cardiomyopathy underwent catheter ablation for atrial fibrillation and atrial flutter. Hypoxemia refractory to the administration of oxygen was seen after transseptal puncture. Transthoracic echocardiography revealed right to left shunt via an iatrogenic atrial septal defect (IASD) that was increased by tricuspid regurgitation flow. Her hypoxemia improved after IASD occlusion with the inflation of a venogram balloon catheter. Emergent surgical IASD closure was successfully performed. IASD after transseptal puncture for atrial fibrillation ablation infrequently causes severe complications that require emergent repair. Learning objective: Some cases requiring iatrogenic atrial septal defect (IASD) closure after atrial fibrillation (AF) ablation have been reported. We describe the case of an arrhythmogenic right ventricular cardiomyopathy patient with right to left shunt via an IASD which required emergent surgical repair after AF ablation. Right to left shunt after trans-septal puncture is rare, however it can be an emergent life-threatening complication. IASD occlusion with venogram balloon catheter is helpful for the diagnosis and the short-term solution.

4.
Heart Vessels ; 38(3): 413-421, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36194289

RESUMEN

The "pre-freezing" technique was a method in which a fully inflated balloon after the start of freezing was pressed against the pulmonary vein (PV) during cryoballoon ablation and has been applied especially in large-size PVs. Of 556 patients who underwent cryoballoon ablation for atrial fibrillation (AF), the pre-freezing technique was applied to 48 patients. The resulting 2:1 propensity score-matched data set included 120 patients. Using the pre-freezing technique, all left-superior PVs, all left-inferior PVs, and 95% of right-superior PVs were successfully isolated. In most right-inferior PVs, complete sealing using the pre-freezing technique was challenging, and this technique was not applied. Procedure time was similar between the two groups. In the pre-freezing group, the percentage of the left atrial posterior wall isolated was larger (47.6 ± 10.3 vs. 42.8 ± 15.7%, P = 0.006), and the postoperative reduction of diaphragmatic compound motor action potentials tended to occur less frequently (2.5 vs. 12.5%, P = 0.07), and the reduction of the cross-sectional LSPV area was smaller (17.5 ± 12.2 vs. 27.2 ± 19.8%, P = 0.03) than the conventional group. The AF-free rate of the two groups was similar between the two groups (P = 0.15). The pre-freezing technique was a simple method that can isolate a wider surface area during cryoballoon PV isolation. While the postoperative AF recurrence was comparable, the postoperative reduction in the cross-sectional PV area was less than that of the conventional method, which may reduce the risk of PV stenosis.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Criocirugía , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Venas Pulmonares/cirugía , Congelación , Estudios Transversales , Criocirugía/efectos adversos , Criocirugía/métodos , Resultado del Tratamiento
5.
J Cardiovasc Electrophysiol ; 33(9): 2100-2103, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35842800

RESUMEN

INTRODUCTION: Catheter ablation for atrial fibrillation (AF) in patients with tachycardia-bradycardia syndrome (TBS) can be a major therapeutic option to replace permanent pacemaker implantation (PMI). However, the very long-term outcome of more than 15 years in these patients has not been elucidated. METHODS: From 2002 to 2008, 25 consecutive TBS patients (62 ± 7.9 years old, 68% male) with both AF and symptomatic sinus pauses (>3.0 s) were performed radiofrequency AF ablation. These patients were followed for 15 ± 2.7 years. RESULTS: The median longest sinus pause before the ablation procedure was 6.0 s (4.4-8.0). Following 1.6± 0.8 ablation procedures, 18 (72%) patients remained free from AF. Three (12%) patients died due to noncardiovascular causes, and seven (28%) patients underwent PMI due to symptomatic sinus pause after recurrent AF in five patients and progression of sinus node dysfunction in two patients. The median duration from the first AF ablation to PMI was 6.3 years (range: 9 days to 11.0 years). Five and two patients required PMI more than 5 and 10 years after the first ablation procedure, respectively. CONCLUSION: AF ablation prevented PMI in 72% of TBS patients for a 15-year follow-up. However, in consideration of the long duration of PMI, a continuous careful long-term follow-up was warranted.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Bradicardia , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Recurrencia , Síndrome del Seno Enfermo/terapia , Taquicardia/diagnóstico , Taquicardia/cirugía , Resultado del Tratamiento
6.
Circ Arrhythm Electrophysiol ; 15(5): e010020, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35476455

RESUMEN

BACKGROUND: Frequent premature ventricular contractions (PVCs) are often amenable to catheter ablation. However, a deep intramural focus may lead to failure due to inability of standard ablation techniques to penetrate the focus. We sought to assess the efficacy and safety of infusion needle ablation (INA) for PVCs that are refractory to standard radiofrequency ablation. METHODS: Under 2 Food and Drug Administration approved protocols, INA was evaluated in patients with frequent PVCs that were refractory to standard ablation. Initial targets for ablation were selected by standard mapping techniques. INA was performed with a deflectable catheter equipped with an extendable/retractable needle at the tip that can be extended up to 12 mm into the myocardium and is capable of pacing and recording. After contrast injection for location assessment, radiofrequency ablation was performed with the needle tip using a temperature-controlled mode (maximum temperature 60 °C) with saline infusion from the needle. The primary end point was a decrease in PVC burden to <5000/24 hours at 6 months. The primary safety end point was incidence of procedure- or device-related serious adverse events. RESULTS: At 4 centers, 35 patients (age 55.3±16.9 years, 74.2% male) underwent INA. The baseline median PVC burden was 25.4% (interquartile range, 18.4%-33.9%) and mean left ventricular ejection fraction was 37.7±12.3%. Delivering 10.3±8.0 INA lesions/patient (91% had adjunctive standard radiofrequency ablation also) resulted in acute PVC elimination in 71.4%. After a mean follow-up of 156±109 days, the primary efficacy end point was met in 73.3%. The median PVC burden decreased to 0.8% (interquartile range, 0.1%-6.0%; P<0.001). The primary safety end point occurred in 14.3% consisting of 1 (2.9%) heart block, 1 (2.9%) femoral artery dissection, and 3 (8.6%) pericardial effusions (all treated percutaneously). CONCLUSIONS: INA is effective for the elimination of frequent PVCs that are refractory to conventional ablation and is associated with an acceptable safety profile. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT01791543 and NCT03204981.


Asunto(s)
Ablación por Catéter , Complejos Prematuros Ventriculares , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Volumen Sistólico , Resultado del Tratamiento , Función Ventricular Izquierda , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/cirugía
7.
Int J Cardiol Heart Vasc ; 40: 101020, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35434257

RESUMEN

Background: It was previously reported, based on a retrospective study, that preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation reduced the incidence of asymptomatic cerebral embolism (ACE). The present study aims to compare the incidence of ACE between a conventional and pre-inflation method during cryoballoon ablation in a prospective randomized controlled study. Methods: A total of 98 atrial fibrillation patients were enrolled and randomized into conventional and pre-inflation groups. Patients in the pre-inflation group received balloon massaging with preliminary extracorporeal balloon inflation in saline water before the cryoballoon was inserted into the body. Results: The baseline characteristics were similar between the two groups. Post-procedural 3-Tesla MRI revealed CE in 27.6% of patients. Symptomatic CE only occurred in two patients in the pre-inflation group. One patient had transient dysarthria and mild muscle weakness in one hand; the other patient complained of transient left upper limb weakness, left lower limb paresthesia and dysarthria. The incidence of ACE detected by cerebral MRI did not differ between the two groups to a statistically significant extent (conventional vs. pre-inflation; 22.9% vs. 29.2%; P = 0.49). In the multivariable analysis, eGFR was independently associated with the presence of ACE (odds ratio 0.95; 95% confidence interval 0.907-0.995; P = 0.03). Conclusion: In this prospective randomized study, the preliminary removal of air bubbles in heparinized saline water with extracorporeal balloon inflation had no impact on the incidence of ACE.

9.
Europace ; 24(4): 598-605, 2022 04 05.
Artículo en Inglés | MEDLINE | ID: mdl-34791165

RESUMEN

AIM: To describe clinical characteristics, procedural details, specific challenges, and outcomes in patients with HeartMate3™ (HM3), a left ventricular assist device system with a magnetically levitated pump, undergoing ventricular tachycardia ablation (VTA). METHODS AND RESULTS: Data were collected from patients with an HM3 system who underwent VTA in seven tertiary centres. Data included baseline patient characteristics, procedural data, mortality, and arrhythmia-free survival. The study cohort included 19 patients with cardiomyopathy presenting with ventricular tachycardia (VT) (53% with VT storm). Ventricular tachycardias were induced in 89% of patients and a total of 41 VTs were observed. Severe electromagnetic interference was present on the surface electrocardiogram. Hence, VT localization required analysis of intra-cardiac signals or the use of filter in the 40-20 Hz range. The large house pump HM3 design obscured the cannula inflow and therefore multi imaging modalities were necessary to avoid catheter entrapment in the cannula. A total of 32 VTs were mapped and were successfully ablated (31% to the anterior wall, 38% to the septum and only 9% to the inflow cannula region). Non-inducibility of any VT was reached in 11 patients (58%). Over a follow-up of 429 (interquartile range 101-692) days, 5 (26%) patients underwent a redo VT ablation due to recurrent VTA and 2 (11%) patients died. CONCLUSIONS: Ventricular tachycardia ablation in patients with HM3 is feasible and safe when done in the appropriate setup. Long-term arrhythmia-free survival is acceptable but not well predicted by non-inducibility at the end of the procedure.


Asunto(s)
Cardiomiopatías , Ablación por Catéter , Corazón Auxiliar , Taquicardia Ventricular , Cardiomiopatías/etiología , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Humanos , Recurrencia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirugía , Resultado del Tratamiento
10.
Heart Vessels ; 37(1): 110-114, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34216250

RESUMEN

The temporal changes in ambulatory monitoring findings after cryoballoon (CB) ablation of atrial fibrillation (AF) have not been well elucidated. This study aims to compare the details of ambulatory monitoring after CB and radiofrequency catheter (RFC) ablation for AF. Of 724 consecutive AF patients who underwent initial ablation using a CB or RFC, 508 (254 pairs) were selected using propensity score matching. Ambulatory monitoring was performed at 1, 3, 6, 12, 24 and 36 months after the procedure. After 1, 3 and 6 months, the number of total heart beats (THBs) was larger in the CB group than in the RFC group. It gradually decreased and became significantly similar by 12 months after ablation. THBs significantly increased 1, 3, 6 and 12 months after ablation in both the RFC and CB groups and became statistically similar by 24 months after ablation. The atrial premature contraction burden was higher in the RFC group than in the CB group at 3 months after ablation. THB and APC burden after AF ablation were significantly different between the RF and CB groups. THBs returned to statistically similarity by 2 years after ablation in both groups.


Asunto(s)
Fibrilación Atrial , Complejos Atriales Prematuros , Ablación por Catéter , Venas Pulmonares , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Complejos Atriales Prematuros/diagnóstico , Criocirugía/efectos adversos , Frecuencia Cardíaca , Humanos , Venas Pulmonares/cirugía , Recurrencia , Resultado del Tratamiento
11.
Sci Rep ; 11(1): 23591, 2021 12 08.
Artículo en Inglés | MEDLINE | ID: mdl-34880293

RESUMEN

The optimal ablation strategy for persistent atrial fibrillation (PsAF) remains to be defined. We sought to compare very long-term outcomes between linear ablation and electrogram (EGM)-guided ablation for PsAF. In a retrospective analysis, long-term arrhythmia-free survival compared between two propensity-score matched cohorts, one with pulmonary vein isolation (PVI) and linear ablation including roof/mitral isthmus line (LINE-group, n = 52) and one with PVI and EGM-guided ablation (EGM-group; n = 52). Overall, 99% of patients underwent successful PVI. Complete block following linear ablation was achieved for 94% of roof lines and 81% of mitral lines (both lines blocked in 75%). AF termination by EGM-guided ablation was accomplished in 40% of patients. Non-PV foci were targeted in 7 (13%) in the LINE-group and 5 (10%) patients in the EGM-group (p = 0.76). During 100 ± 28 months of follow-up, linear ablation was associated with superior arrhythmia-free survival after the initial and last procedure (1.8 ± 0.9 procedures) compared with EGM-group (Logrank test: p = 0.0001 and p = 0.045, respectively). In multivariable analysis, longer AF duration and EGM-guided ablation remained as independent predictors of atrial arrhythmia recurrence. Linear ablation might be a more effective complementary technique to PVI than EGM-guided ablation for PsAF ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Puntaje de Propensión , Venas Pulmonares/cirugía , Recurrencia , Estudios Retrospectivos , Factores de Tiempo , Resultado del Tratamiento
13.
JACC Clin Electrophysiol ; 7(9): 1182-1192, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-33812827

RESUMEN

OBJECTIVES: This study sought to investigate the factors associated with repeat infection following lead extraction procedures. BACKGROUND: Although lead extraction is an essential therapy for patients with cardiovascular implantable electronic device (CIED) infection, repeat infection still occurs in some patients. METHODS: The authors reviewed data for consecutive patients who underwent extraction of infected CIEDs from August 2003 to May 2019. Repeat infection was defined as infective endocarditis, sepsis with no alternative focus, or pocket infection after extraction of infected CIEDs. RESULTS: Extraction of infected CIEDs was performed in 496 patients. The most commonly implicated pathogen was Staphylococcus aureus (n = 188). In 449 patients (90.5%), all leads were completely extracted using only transvenous techniques. Thirty-three patients (6.7%) underwent surgical lead extraction, and 14 (2.8%) had retained leads or lead components. After a median follow-up of 352 [40 to 1,255] days after CIED extraction, 144 patients (29.0%) died. Repeat infection occurred in 47 patients (9.5%) with the median time from the extraction to repeat infection of 103 [45 to 214] days. In multivariable analysis, presence of a left ventricular assist device, younger age at extraction, and S. aureus infection were independent predictors of repeat infection. Additionally, chronic kidney disease, congestive heart failure, presence of septic emboli, S. aureus infection, and occurrence of major complications were independent predictors of increased mortality. CONCLUSIONS: Patients with S. aureus infection have a high risk of repeat infection and poor prognosis after CIED extraction. Repeat infection is also predicted by younger age and the presence of a left ventricular assist device, whereas mortality was predicted by congestive heart failure, chronic kidney disease, and septic emboli.


Asunto(s)
Desfibriladores Implantables , Infecciones Relacionadas con Prótesis , Desfibriladores Implantables/efectos adversos , Electrónica , Humanos , Infecciones Relacionadas con Prótesis/epidemiología , Estudios Retrospectivos , Factores de Riesgo , Staphylococcus aureus
14.
Sci Rep ; 11(1): 6226, 2021 03 18.
Artículo en Inglés | MEDLINE | ID: mdl-33737633

RESUMEN

While phrenic nerve palsy (PNP) due to cryoballoon pulmonary vein isolation (PVI) of atrial fibrillation (AF) was transient in most cases, no studies have reported the results of the long-term follow-up of PNP. This study aimed to summarize details and the results of long-term follow-up of PNP after cryoballoon ablation. A total of 511 consecutive AF patients who underwent cryoballoon ablation was included. During right-side PVI, the diaphragmatic compound motor action potential (CMAP) was reduced in 46 (9.0%) patients and PNP occurred in 29 (5.7%) patients (during right-superior PVI in 20 patients and right-inferior PVI in 9 patients). PNP occurred despite the absence of CMAP reduction in 0.6%. The PV anatomy, freezing parameters and the operator's proficiency were not predictors of PNP. While PNP during RSPVI persisted more than 4 years in 3 (0.6%) patients, all PNP occurred during RIPVI recovered until one year after the ablation. However, there was no significant difference in the recovery duration from PNP between PNP during RSPVI and RIPVI. PNP occurred during cryoballoon ablation in 5.7%. While most patients recovered from PNP within one year after the ablation, PNP during RSPVI persisted more than 4 years in 0.6% of patients.


Asunto(s)
Angioplastia de Balón/efectos adversos , Fibrilación Atrial/cirugía , Ablación por Catéter/efectos adversos , Parálisis/diagnóstico , Traumatismos de los Nervios Periféricos/diagnóstico , Nervio Frénico/lesiones , Anciano , Fibrilación Atrial/patología , Criocirugía/instrumentación , Criocirugía/métodos , Humanos , Masculino , Persona de Mediana Edad , Parálisis/etiología , Parálisis/patología , Traumatismos de los Nervios Periféricos/etiología , Traumatismos de los Nervios Periféricos/patología , Venas Pulmonares/cirugía , Factores de Tiempo , Resultado del Tratamiento
15.
Circ Arrhythm Electrophysiol ; 14(2): e008887, 2021 02.
Artículo en Inglés | MEDLINE | ID: mdl-33417473

RESUMEN

BACKGROUND: Periaortic fibrotic ventricular tachycardia (VT) substrate is common in nonischemic cardiomyopathy (NICM), often intramural, and difficult to ablate. We sought to better characterize normal and abnormal periaortic voltage map parameters and NICM periaortic VTs. METHODS: In 15 patients without heart disease, the 5th percentile of endocardial voltage for increasing distance from the aortic valve ring was determined. In 53 consecutive patients with NICM (64±11 years; left ventricular ejection fraction 31±10%) undergoing ablation of recurrent VT, periaortic electrogram voltage and VT characteristics were analyzed. RESULTS: In healthy patients, the fifth percentile of the bipolar voltage increased proportional to the distance from the aortic valve ring, from 1.0 mV at 1 cm to 1.5 mV at 1.5 cm; the corresponding unipolar voltage cutoffs were 5.0 and 7.5 mV. A total of 160 VTs were induced in 53 patients with NICM, of which 28 VTs in 20 patients had periaortic origins. Periaortic VTs were associated with similar periaortic bipolar voltage, but lower UVs consistent with intramural fibrosis as an important substrate. Periaortic VTs could be divided into left and right bundle branch block forms with mapping showing right septal and lateral exits. Left bundle branch block VTs were more often acutely abolished with ablation (100% versus 69%; P=0.034), but with a 23% incidence of heart block. Greater extent of low voltage was associated with more induced VTs and worse acute outcome. CONCLUSIONS: Adjusting voltage parameters based on distance from the aortic valve may improve definition of left ventricular outflow tract arrhythmia substrate. Periaortic VTs are common in NICM, often associated with intramural substrate and can be divided into left bundle branch block and right bundle branch block types associated with different ablation outcomes and risks.


Asunto(s)
Cardiomiopatías/complicaciones , Electrocardiografía , Frecuencia Cardíaca/fisiología , Taquicardia Ventricular/diagnóstico , Función Ventricular Izquierda/fisiología , Anciano , Cardiomiopatías/diagnóstico , Cardiomiopatías/fisiopatología , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Taquicardia Ventricular/etiología , Taquicardia Ventricular/fisiopatología
16.
J Interv Card Electrophysiol ; 60(1): 69-75, 2021 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-32048116

RESUMEN

PURPOSE: Current guidelines recommend complete extraction of cardiovascular implantable electronic devices (CIEDs) in the case of persistent or recurrent fungemia without other identifiable sources, though supporting evidence is lacking. We sought to evaluate the prognosis of patients with candidemia and CIEDs. METHODS: Twelve consecutive patients (54 ± 12 years, 8 male) with CIED and concurrent candidemia were reviewed. RESULTS: At the time of diagnosis with candidemia, seven patients were immunocompromised, six were on long-term antibacterial therapy, two were intravenous drug users, four were on chronic hemodialysis, and six had a central venous catheter. Four patients were confirmed as definite CIED infection as vegetation was visible on lead by echocardiogram. The other 8 patients were considered possible CIED infection with candidemia of unknown focus. All patients with visible vegetation underwent CIED removal without complications, and other patients were initially managed non-operatively. After 1 year of follow-up, 7 patients had died and at extended follow-up, all patients without lead removal died while 3 of 4 patients with lead extraction survived. Of note, 50% of deaths in the patients without lead removal were associated with fungal sepsis. CONCLUSIONS: Candida fungemia is associated with a high mortality. CIED removal should be an early consideration in these patients even if lead vegetations are not seen.


Asunto(s)
Candidemia , Desfibriladores Implantables , Marcapaso Artificial , Infecciones Relacionadas con Prótesis , Candidemia/diagnóstico por imagen , Desfibriladores Implantables/efectos adversos , Remoción de Dispositivos , Electrónica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
17.
Heart Rhythm ; 18(5): 752-759, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33321197

RESUMEN

BACKGROUND: Staphylococcus bacteremia (SB) in the presence of a cardiac implantable electronic device (CIED) is frequently associated with CIED infection. In patients without clear CIED infection but SB, the role of empirical CIED removal is unclear. OBJECTIVE: The purpose of this study was to describe the natural history of SB in the setting of a CIED and the effect of CIED removal on mortality in patients with concurrent SB without evidence of CIED infection. METHODS: Three hundred sixty consecutive patients (mean age 61 ± 17 years; 255 (71%) men; 329 (92%) Staphylococcus aureus) with a CIED and concurrent SB were reviewed. RESULTS: At the initial presentation with SB, 178 patients had no evidence of CIED infection. Of these, 132 (74%) had another identified source of infection. Among the 178 patients without CIED infection, 18 (10%) had empirical CIED removal during the initial bacteremia. Among those who did not undergo CIED removal, SB subsequently relapsed in 19% and relapse rates were not different for those with or without another identifiable source at the initial presentation. Relapse was strongly associated with the duration of SB >1 day (odds ratio 9.99; 95% confidence interval 3.24-30.86). Despite the absence of CIED infection, 1-year mortality was 35% and empirical device removal during the initial presentation was associated with survival benefit (hazard ratio 0.28; 95% confidence interval 0.08-0.95). CONCLUSION: For patients with SB without evidence of CIED infection, relapse is predicted by the duration of bacteremia. Empirical CIED removal appears to be associated with a survival benefit, although there are likely clinical situations in which this could be deferred.


Asunto(s)
Arritmias Cardíacas/terapia , Bacteriemia/etiología , Marcapaso Artificial/efectos adversos , Infecciones Estafilocócicas/etiología , Staphylococcus aureus/aislamiento & purificación , Bacteriemia/microbiología , Remoción de Dispositivos/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Factores de Riesgo , Infecciones Estafilocócicas/microbiología
19.
JACC Clin Electrophysiol ; 5(11): 1303-1315, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31753437

RESUMEN

OBJECTIVES: This study examined the anatomical or procedural factors associated with severe pulmonary vein (PV) stenosis after cryoballoon PV isolation. BACKGROUND: PV stenosis is a complication associated with cryoballoon ablation. METHODS: The study included 170 consecutive patients with paroxysmal atrial fibrillation who underwent cryoballoon ablation. In addition to factors generally considered to be related to the occurrence of PV stenosis (PV size, cryoballoon application number and time, and minimum freezing temperature), we evaluated the following 4 factors: 1) depth of balloon position; 2) the PV angle (internal angle between each PV and horizontal line); 3) noncoaxial balloon placement (hemispherical occlusion); and 4) contact surface area between the cryoballoon and the PV wall (defined as the balloon contact ratio). RESULTS: Severe PV stenosis (≥75% area reduction) was observed in 9 (1.3%) PVs (6 left superior and 3 right superior PVs) in 9 patients. The PV size, cryoballoon application number and time, minimum freezing temperature, and the depth of cryoballoon position were not significantly associated with occurrence of severe PV stenosis, but the PV angle was significantly smaller in PVs with severe stenosis than it was in those without stenosis (25.6 ± 9.7° vs. 34.2 ± 6.4°; p < 0.001). Hemispherical occlusion was more frequently observed and balloon contact ratio was larger in PVs with severe stenosis (55.6% vs. 14.8%; p = 0.049) than in those without stenosis (0.70 ± 0.06 vs. 0.54 ± 0.08; p < 0.001). CONCLUSIONS: A horizontally connecting PV, noncoaxial placement of cryoballoon, and a larger contact surface area of the cryoballoon were predictors of the occurrence of severe PV stenosis after cryoballoon ablation.


Asunto(s)
Fibrilación Atrial/cirugía , Criocirugía/métodos , Complicaciones Posoperatorias/epidemiología , Venas Pulmonares/cirugía , Estenosis de Vena Pulmonar/epidemiología , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Venas Pulmonares/anatomía & histología , Índice de Severidad de la Enfermedad
20.
J Cardiovasc Electrophysiol ; 30(11): 2310-2318, 2019 11.
Artículo en Inglés | MEDLINE | ID: mdl-31452290

RESUMEN

BACKGROUND: The presence of heart failure (HF) has been associated with poorer outcomes in patients undergoing catheter ablation (CA) for atrial fibrillation (AF). However, the effectiveness of CA amongst the subset of patients with tachycardia-induced cardiomyopathy (TIC) remains poorly defined. METHODS AND RESULTS: In a retrospective analysis we compared outcomes of first-time CA for persistent AF in a cohort of patients with previously diagnosed TIC (n = 45; age 58 ± 8 years; 91% male) to those with structurally normal hearts (non-TIC; n = 440; age 55 ± 9 years; 95% male). TIC was defined as an impaired ventricular function (left ventricular ejection function [LVEF] <50%), which was reversed after the treatment of HF. We compared atrial arrhythmias (AAs) recurrence after the CA in the TIC and non-TIC cohorts. In the TIC group, LVEF improved from 35.8% ± 8.1% to 57.5% ± 8.3% after treatment of HF. During 3.3 ± 1.5 years follow-up, AAs-free survival after CA was significantly higher in the TIC group as compared with the non-TIC group (69% vs 42%; P = .001), despite a comparable CA strategy between the two groups. In multivariable analysis, absence of HF with TIC, longer AF duration, and complex fractionated atrial electrogram ablation were independent predictors of arrhythmia recurrence (OR, 1.02; 95% CI, 1.01-1.03; P < .01; OR, 0.40; 95% CI, 0.20-0.79; P < .01 and OR, 2.29; 95%CI; 1.27-4.11; P < .01, respectively). In addition, the outcome after the last procedure was superior in the TIC cohort (89% vs 72%; P = .03) with fewer CA procedures as compared with the non-TIC cohort (1.3 ± 0.5 vs 1.5 ± 0.7; P = .01). CONCLUSIONS: Persistent patients with AF with TIC have a more favorable outcome after the CA as compared with those without.


Asunto(s)
Fibrilación Atrial/cirugía , Cardiomiopatías/etiología , Ablación por Catéter , Potenciales de Acción , Anciano , Fibrilación Atrial/complicaciones , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Ablación por Catéter/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Recuperación de la Función , Recurrencia , Estudios Retrospectivos , Factores de Riesgo , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento , Función Ventricular Izquierda
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA