1.
Appl Radiat Isot ; 134: 385-390, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29248210

RESUMEN

An international key comparison, identifier CCRI(II)-K2.Ge-68, has been performed. The National Institute of Standards and Technology (NIST) served as the pilot laboratory, distributing aliquots of a 68Ge/68Ga solution. Results for the activity concentration, CA, of 68Ge at a reference date of 12h00 UTC 14 November 2014 were submitted by 17 laboratories, encompassing many variants of coincidence methods and liquid-scintillation counting methods. The first use of 4π(Cherenkov)ß-γ coincidence and anticoincidence methods in an international comparison is reported. One participant reported results by secondary methods only. Two results, both utilizing pure liquid-scintillation methods, were identified as outliers. Evaluation using the Power-Moderated Mean method results in a proposed Comparison Reference Value (CRV) of 621.7(11)kBqg-1, based on 14 results. The degrees of equivalence and their associated uncertainties are evaluated for each participant. Several participants submitted 3.6mL ampoules to the BIPM to link the comparison to the International Reference System (SIR) which may lead to the evaluation of a Key Comparison Reference Value and associated degrees of equivalence.

2.
Phys Lett B ; 761: 281-286, 2016 10.
Artículo en Inglés | MEDLINE | ID: mdl-28057978

RESUMEN

The hypothesis that proximity to the Sun causes variation of decay constants at permille level has been tested and disproved. Repeated activity measurements of mono-radionuclide sources were performed over periods from 200 days up to four decades at 14 laboratories across the globe. Residuals from the exponential nuclear decay curves were inspected for annual oscillations. Systematic deviations from a purely exponential decay curve differ from one data set to another and are attributable to instabilities in the instrumentation and measurement conditions. The most stable activity measurements of alpha, beta-minus, electron capture, and beta-plus decaying sources set an upper limit of 0.0006% to 0.008% to the amplitude of annual oscillations in the decay rate. Oscillations in phase with Earth's orbital distance to the Sun could not be observed within a 10-6 to 10-5 range of precision. There are also no apparent modulations over periods of weeks or months. Consequently, there is no indication of a natural impediment against sub-permille accuracy in half-life determinations, renormalisation of activity to a distant reference date, application of nuclear dating for archaeology, geo- and cosmochronology, nor in establishing the SI unit becquerel and seeking international equivalence of activity standards.

3.
Appl Radiat Isot ; 70(9): 1990-6, 2012 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-22421399

RESUMEN

The work presented here is a new and precise measurement of the half-life of (166m)Ho by determining the activity concentration, using an ionisation chamber calibrated for this nuclide, and measuring the number of (166m)Ho atoms using multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Since the isotope (166)Er interferes with the mass spectrometric measurement, Er has to be eliminated from the (166m)Ho radioactive solution. The elimination was achieved using ion-exchange chromatography with the cation exchange resin Dowex AG 50W-X8 and 2-Hydroxybutanoic acid as the mobile phase. After a first transit through the chromatographic column, the purified (166m)Ho eluate was spiked with natural Er to get a resulting Er isotopic composition close to that of natural Er at better than 99.5%, and then it underwent two further separations to eliminate the Er. The activity concentration of this Er-free radioactive (166m)Ho solution was measured in our reference ionisation chamber calibrated for this nuclide by means of the 4πß(PC)-γ and 4πß(PS)-4πγ coincidence techniques and integral counting with a well-type NaI(Tl) detector and Monte Carlo efficiencies. An aliquot of this standardized solution was sent to the Paul Scherrer Institute (PSI) for mass concentration determination using an isotope dilution MC-ICP-MS approach. The mass concentration of (166m)Ho in this solution was determined with 0.25% relative standard uncertainty. This value was corroborated by two other independent measurements. The new half-life of (166m)Ho, 1132.6(39) years (k=1), is compatible with the value determined in 1965, but is 5.6% shorter and about 43 times more precise.


Asunto(s)
Holmio/química , Espectrometría de Masas/instrumentación , Radioisótopos/química , Radiometría/instrumentación , Radiometría/normas , Cromatografía por Intercambio Iónico , Diseño de Equipo , Análisis de Falla de Equipo , Semivida , Holmio/análisis , Internacionalidad , Dosis de Radiación , Radioisótopos/análisis , Estándares de Referencia , Valores de Referencia
4.
Appl Radiat Isot ; 68(7-8): 1207-10, 2010.
Artículo en Inglés | MEDLINE | ID: mdl-20153206

RESUMEN

An international exercise, registered as EUROMET project no. 907, was launched to measure both the activity of a solution of (124)Sb and the photon emission intensities of its decay. The same solution was sent by LNE-LNHB to eight participating laboratories. In order to identify possible biases, the participants were asked to use all possible activity measurement methods available in their laboratory and then to determine their reference value for comparison. Thus, measurement results from 4pibeta-gamma coincidence/anti-coincidence counting, CIEMAT/NIST liquid-scintillation counting, 4pigamma counting with well-type ionization chambers and well-type crystal detectors were given. The results are compared and show a maximum discrepancy of about 1.6%: possible explanations are proposed.


Asunto(s)
Antimonio/análisis , Antimonio/normas , Cooperación Internacional , Fotones , Valores de Referencia , Reproducibilidad de los Resultados , Conteo por Cintilación , Soluciones , Pesos y Medidas
5.
Dentomaxillofac Radiol ; 33(4): 211-9, 2004 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15533973

RESUMEN

OBJECTIVES: To measure the frequencies of dental radiological examinations in Switzerland and to determine the associated collective radiation doses. METHODS: To evaluate the frequencies, a sample of 376 dental practitioners and other institutions performing dental radiology were requested to fill in questionnaires designed to measure, amongst others, frequencies of dental radiodiagnoses according to type of examination, patient age and gender, dental specialty and type of surgery. The associated collective radiation doses were determined by multiplying the relevant frequencies with dose estimates obtained from recent measurements and calculations. RESULTS: The total number of dental examinations performed in Switzerland in 1998 was 4.1 million (581 per 1000 population). Periapical, bitewing and panoramic radiographs were the most frequent types of dental examinations. The collective dose associated with dental radiology was 71 person.Sv. This amounts to an annual average effective dose to the population of 10 muSv per caput, which is in agreement with the figures reported for countries of similar healthcare level. Various features such as the age distribution of the radiographed patients, the forms of collimators used, film consumption and the use of digital imaging systems are presented. CONCLUSIONS: Several recommendations for dose reduction are made. These include the re-evaluation of the patterns and justification for prescribing some particular types of dental examinations as well as the avoidance of unnecessary irradiation by the use of rectangular collimation and high sensitivity F-speed films.


Asunto(s)
Dosis de Radiación , Radiografía Dental/estadística & datos numéricos , Adolescente , Adulto , Distribución por Edad , Factores de Edad , Anciano , Anciano de 80 o más Años , Niño , Preescolar , Diseño de Equipo/estadística & datos numéricos , Femenino , Humanos , Lactante , Masculino , Persona de Mediana Edad , Radiografía de Mordida Lateral/estadística & datos numéricos , Radiografía Dental/clasificación , Radiografía Dental/instrumentación , Radiografía Dental Digital/estadística & datos numéricos , Radiografía Panorámica/estadística & datos numéricos , Factores Sexuales , Suiza , Película para Rayos X/estadística & datos numéricos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...