1.
Sci Rep ; 11(1): 22224, 2021 11 15.
Artículo en Inglés | MEDLINE | ID: mdl-34782698

RESUMEN

Contrast-enhanced mammography (CEM) has shown to be superior to full-field digital mammography (FFDM), but current results are dominated by studies performed on systems by one vendor. Information on diagnostic accuracy of other CEM systems is limited. Therefore, we aimed to evaluate the diagnostic performance of CEM on an alternative vendor's system. We included all patients who underwent CEM in one hospital in 2019, except those with missing data or in whom CEM was used as response monitoring tool. Three experienced breast radiologists scored the low-energy images using the BI-RADS classification. Next, the complete CEM exams were scored similarly. Histopathological results or a minimum of one year follow-up were used as reference standard. Diagnostic performance and AUC were calculated and compared between low-energy images and the complete CEM examination, for all readers independently as well as combined. Breast cancer was diagnosed in 23.0% of the patients (35/152). Compared to low-energy images, overall CEM sensitivity increased from 74.3 to 87.6% (p < 0.0001), specificity from 87.8 to 94.6% (p = 0.0146). AUC increased from 0.872 to 0.957 (p = 0.0001). Performing CEM on the system tested, showed that, similar to earlier studies mainly performed on another vendor's systems, both sensitivity and specificity improved when compared to FFDM.


Asunto(s)
Neoplasias de la Mama/diagnóstico , Mama/diagnóstico por imagen , Mama/patología , Mamografía/métodos , Adulto , Anciano , Anciano de 80 o más Años , Biomarcadores de Tumor , Neoplasias de la Mama/epidemiología , Neoplasias de la Mama/etiología , Toma de Decisiones Clínicas , Medios de Contraste , Manejo de la Enfermedad , Femenino , Humanos , Imagen por Resonancia Magnética , Mamografía/normas , Tamizaje Masivo , Persona de Mediana Edad , Curva ROC , Intensificación de Imagen Radiográfica , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X
2.
Trials ; 20(1): 759, 2019 Dec 23.
Artículo en Inglés | MEDLINE | ID: mdl-31870414

RESUMEN

BACKGROUND: In the Dutch breast cancer screening program, women recalled with a BI-RADS 0 score are referred for additional imaging, while those with BI-RADS 4/5 scores are also directed to an outpatient breast clinic. Approximately six out of ten women are recalled without being diagnosed with a malignancy. However, these recalls require additional imaging and doctor visits, which result in patient anxiety and increased health care costs. Conventional types of imaging used for additional imaging are full-field digital mammography and tomosynthesis. Contrast-enhanced spectral mammography has proved to have higher sensitivity and specificity than conventional imaging in women recalled from screening. Therefore, the aim is to study if CESM instead of conventional imaging is a more accurate, patient-friendly, and cost-effective strategy in the work-up of women recalled from breast cancer screening. METHODS: This prospective, multicenter, randomized controlled trial will be conducted at four centers and will include 528 patients recalled for suspicious breast lesions from the Dutch breast cancer screening program. Participants are randomized in two groups: (1) standard care using conventional breast imaging techniques as initial imaging after recall versus (2) work-up primarily based on CESM. Written informed consent will be collected prior to study inclusion. The primary outcome is the diagnostic accuracy for detection of breast cancer. Secondary outcomes are numbers of additional diagnostic exams, days until final diagnosis, health care costs, and experienced patient anxiety. DISCUSSION: Based on previously published retrospective studies, we expect to demonstrate in this prospective multicenter randomized controlled trial, that using CESM as a primary work-up tool in women recalled from breast cancer screening is a more accurate, cost-effective, and patient-friendly strategy. TRIAL REGISTRATION: Netherlands Trial Register, NL6413/NTR6589. Registered on 6 July, 2017.


Asunto(s)
Neoplasias de la Mama/diagnóstico por imagen , Detección Precoz del Cáncer/métodos , Mamografía/métodos , Ansiedad/psicología , Biopsia con Aguja Fina , Biopsia con Aguja Gruesa , Neoplasias de la Mama/irrigación sanguínea , Medios de Contraste , Análisis Costo-Beneficio , Detección Precoz del Cáncer/economía , Detección Precoz del Cáncer/psicología , Femenino , Costos de la Atención en Salud , Accesibilidad a los Servicios de Salud , Humanos , Imagen por Resonancia Magnética , Mamografía/economía , Mamografía/psicología , Países Bajos , Ultrasonografía Mamaria
3.
Med Phys ; 43(1): 518, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26745945

RESUMEN

PURPOSE: In mammography, the height of the image receptor is adjusted to the patient before compressing the breast. An inadequate height setting can result in an imbalance between the forces applied by the image receptor and the paddle, causing the clamped breast to be pushed up or down relative to the body during compression. This leads to unnecessary stretching of the skin and other tissues around the breast, which can make the imaging procedure more painful for the patient. The goal of this study was to implement a method to measure and minimize the force imbalance, and to assess its feasibility as an objective and reproducible method of setting the image receptor height. METHODS: A trial was conducted consisting of 13 craniocaudal mammographic compressions on a silicone breast phantom, each with the image receptor positioned at a different height. The image receptor height was varied over a range of 12 cm. In each compression, the force exerted by the compression paddle was increased up to 140 N in steps of 10 N. In addition to the paddle force, the authors measured the force exerted by the image receptor and the reaction force exerted on the patient body by the ground. The trial was repeated 8 times, with the phantom remounted at a slightly different orientation and position between the trials. RESULTS: For a given paddle force, the obtained results showed that there is always exactly one image receptor height that leads to a balance of the forces on the breast. For the breast phantom, deviating from this specific height increased the force imbalance by 9.4 ± 1.9 N/cm (6.7%) for 140 N paddle force, and by 7.1 ± 1.6 N/cm (17.8%) for 40 N paddle force. The results also show that in situations where the force exerted by the image receptor is not measured, the craniocaudal force imbalance can still be determined by positioning the patient on a weighing scale and observing the changes in displayed weight during the procedure. CONCLUSIONS: In mammographic breast compression, even small changes in the image receptor height can lead to a severe imbalance of the applied forces. This may make the procedure more painful than necessary and, in case the image receptor is set too low, may lead to image quality issues and increased radiation dose due to undercompression. In practice, these effects can be reduced by monitoring the force imbalance and actively adjusting the position of the image receptor throughout the compression.


Asunto(s)
Mamografía/instrumentación , Fenómenos Mecánicos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA