Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
J Invasive Cardiol ; 13(4): 272-8, 2001 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-11287711

RESUMEN

Randomized controlled trials of patients with non-ST segment elevation acute coronary syndromes have established the superiority of enoxaparin (versus unfractionated heparin) for reducing adverse ischemic outcomes. Furthermore, adjunctive abciximab therapy during percutaneous coronary intervention (PCI) is associated with improved clinical outcomes. Since algorithms for integrating these pharmacotherapies have not been determined, patients undergoing elective PCI were enrolled into 2 distinct and separate studies conducted by the National Investigators Collaborating on Enoxaparin (NICE) study groups (NICE 1 and NICE 4 studies). Patients in NICE 1 were administered enoxaparin 1.0 mg/kg intravenously (without abciximab) and those enrolled in NICE 4 were administered a reduced dose (0.75 mg/kg) of enoxaparin in combination with standard-dose abciximab intravenously during PCI. Bleeding events and ischemic outcomes assessed in-hospital and at 30-days post-PCI were infrequent with either pharmacologic regimen. In the dose regimens studied, enoxaparin with or without abciximab appears to provide safe and effective anticoagulation during PCI. The combination of reduced-dose enoxaparin and abciximab was associated with a low incidence of adverse outcomes (bleeding or ischemic events). Additional studies may be required to establish the relative safety and efficacy of this new adjunctive pharmacologic strategy when compared with the combination of low-dose, weight-adjusted unfractionated heparin and abciximab.


Asunto(s)
Angioplastia Coronaria con Balón , Anticuerpos Monoclonales/uso terapéutico , Anticoagulantes/uso terapéutico , Enfermedad Coronaria/terapia , Enoxaparina/uso terapéutico , Fragmentos Fab de Inmunoglobulinas/uso terapéutico , Abciximab , Anticuerpos Monoclonales/administración & dosificación , Anticoagulantes/administración & dosificación , Esquema de Medicación , Quimioterapia Combinada , Enoxaparina/administración & dosificación , Femenino , Humanos , Fragmentos Fab de Inmunoglobulinas/administración & dosificación , Masculino , Persona de Mediana Edad , Complejo GPIIb-IIIa de Glicoproteína Plaquetaria/antagonistas & inhibidores
2.
J Am Coll Cardiol ; 12(3): 694-702, 1988 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-2969929

RESUMEN

Conventional over the wire dilation catheters may be unsuccessful in crossing coronary lesions that are severely narrowed. Hence, a new, extremely low profile coronary angioplasty catheter specifically designed to dilate such lesions was investigated. The catheter features a 2.0, 2.5 or 3.0 mm (inflated diameter) balloon mounted on a guide wire. The deflated profile of the 2.0 mm balloon measures 0.020 +/- 0.001 in. (0.51 +/- 0.03 mm). The catheter can be used in conjunction with 7F angiographic or 8F guide catheters. The catheter was used in 61 patients, aged 43 to 86 years, with predominantly Canadian Cardiovascular Society class III-IV angina. Dilation was attempted in 77 lesions. Lesion length averaged 5.7 +/- 3.1 mm (mean +/- 1 SD), minimal diameter 0.51 +/- 0.25 mm and internal vessel diameter 2.27 +/- 0.43 mm. Sixty lesions (78%) were successfully dilated to less than 50% residual stenosis with this catheter alone; nine lesions were further dilated with a larger balloon catheter. The new catheter was unable to cross 13 lesions (17%); only 2 of these lesions were subsequently crossed with a conventional over the wire system. On the other hand, the catheter was used after failure of conventional dilating catheters in 21 lesions and was successful in 16. The new catheter was particularly valuable for distal lesions and those demonstrating 90 to 99% diameter reduction. For all lesions crossed, stenosis decreased from 76 +/- 11 to 29 +/- 12% after 2.9 +/- 2.7 inflations and peak inflation pressure of 8.0 +/- 2.9 bar. Complications were rare; coronary occlusion occurred in two lesions (3%) and dissection in three lesions (4%).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Angioplastia de Balón/instrumentación , Enfermedad Coronaria/terapia , Vasos Coronarios/patología , Adulto , Anciano , Anciano de 80 o más Años , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA