1.
Magn Reson Med ; 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39219165

RESUMEN

PURPOSE: MRI-guidance of cardiac catheterization is currently performed using one or multiple 2D imaging planes, which may be suboptimal for catheter navigation, especially in patients with complex anatomies. The purpose of the work was to develop a robust real-time 3D catheter tracking method and 3D visualization strategy for improved MRI-guidance of cardiac catheterization procedures. METHODS: A fast 3D tracking technique was developed using continuous acquisition of two orthogonal 2D-projection images. Each projection corresponds to a gradient echo stack of slices with only the central k-space lines being collected for each slice. To enhance catheter contrast, a saturation pulse is added ahead of the projection pair. An offline image processing algorithm was developed to identify the 2D coordinates of the balloon in each projection image and to estimate its corresponding 3D coordinates. Post-processing includes background signal suppression using an atlas of background 2D-projection images. 3D visualization of the catheter and anatomy is proposed using three live sagittal, coronal, and axial (MPR) views and 3D rendering. The technique was tested in a subset of a catheterization step in three patients undergoing MRI-guided cardiac catheterization using a passive balloon catheter. RESULTS: The extraction of the catheter balloon 3D coordinates was successful in all patients and for the majority of time-points (accuracy >96%). This tracking method enabled a novel 3D visualization strategy for passive balloon catheter, providing enhanced anatomical context during catheter navigation. CONCLUSION: The proposed tracking strategy shows promise for robust tracking of passive balloon catheter and may enable enhanced visualization during MRI-guided cardiac catheterization.

2.
J Cardiovasc Magn Reson ; : 101097, 2024 Sep 16.
Artículo en Inglés | MEDLINE | ID: mdl-39293786

RESUMEN

BACKGROUND: Coronary computed tomography angiography (CCTA) is recommended as the first line diagnostic imaging modality in low to intermediate risk individuals suspected of stable coronary artery disease (CAD). However, CCTA exposes patients to ionising radiation and potentially nephrotoxic contrast agents. Invasive coronary angiography (ICA) is the gold-standard investigation to guide coronary revascularisation strategy, however, invasive procedures incur an inherent risk to the patient. Coronary magnetic resonance angiography (Coronary MRA) avoids these issues. Nevertheless, clinical implementation is currently limited due to extended scanning durations, inconsistent image quality, and consequent lack of diagnostic accuracy. Several technical Coronary MRA innovations including advanced respiratory motion correction with 100% scan efficiency (no data rejection), fast image acquisition with motion-corrected undersampled image reconstruction and deep-learning (DL)-based automated planning have been implemented and now await clinical validation in multi-centre trials. METHODS: The objective of the iNav-AUTO CMRA prospective multi-centre study is to evaluate the diagnostic accuracy of a newly developed, state-of-the-art, standardised, and automated Coronary MRA framework compared to CCTA in 230 patients undergoing clinical investigation for CAD. The study protocol mandates the administration of oral beta-blockers to decrease heart rate to below 60bpm and the use of sublingual nitroglycerine spray to induce vasodilation. Additionally, the study incorporates the utilisation of standardised postprocessing with sliding-thin-slab multiplanar reformatting, in combination with evaluation of the source images, to optimize the visualisation of coronary artery stenosis. DISCUSSION: If proven effective, Coronary MRA could provide a non-invasive, needle-free, yet also clinically viable, alternative to CCTA. TRIAL REGISTRATION: This study is registered at clinicaltrials.gov (NCT05473117).

3.
Magn Reson Med ; 92(6): 2607-2615, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39155399

RESUMEN

PURPOSE: Myocardial T1ρ mapping techniques commonly acquire multiple images in one breathhold to calculate a single-slice T1ρ map. Recently, non-selective adiabatic pulses have been used for robust spin-lock preparation (T1ρ,adiab). The objective of this study was to develop a fast multi-slice myocardial T1ρ,adiab mapping approach. METHODS: The proposed-sequence reduces the number of breathholds required for whole-heart 2D T1ρ,adiab mapping by acquiring multiple interleaved slices in each breathhold using slice-selective T1ρ,adiab preparation pulses. The proposed-sequence was implemented with two interleaved slices per breathhold scan and was quantitatively evaluated in phantom experiments and 10 healthy-volunteers against a single-slice T1ρ,adiab mapping sequence. The sequence was demonstrated in two patients with myocardial scar. RESULTS: The phantom experiments showed the proposed-sequence had slice-to-slice variation of 1.62% ± 1.05% and precision of 4.51 ± 0.68 ms. The healthy volunteer cohort subject-wise mean relaxation time was lower for the proposed-sequence than the single-slice sequence (137.7 ± 5.3 ms vs. 148.4 ± 8.3 ms, p < 0.001), and spatial-standard-deviation was better (18.7 ± 1.8 ms vs. 21.8 ± 3.4 ms, p < 0.018). The mean within-subject, coefficient of variation was 5.93% ± 1.57% for the proposed-sequence and 6.31% ± 1.92% for the single-slice sequence (p = 0.35) and the effect of slice variation (0.81 ± 4.87 ms) was not significantly different to zero (p = 0.61). In both patient examples increased T1ρ,adiab (maximum American Heart Association-segment mean = 174 and 197 ms) was measured within the myocardial scar. CONCLUSION: The proposed sequence provides a twofold acceleration for myocardial T1ρ,adiab mapping using a multi-slice approach. It has no significant difference in within-subject variability, and significantly better precision, compared to a 2D T1ρ,adiab mapping sequence based on non-selective adiabatic spin-lock preparations.


Asunto(s)
Algoritmos , Corazón , Fantasmas de Imagen , Humanos , Adulto , Corazón/diagnóstico por imagen , Masculino , Femenino , Imagen por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Interpretación de Imagen Asistida por Computador/métodos , Miocardio/patología , Voluntarios Sanos
4.
Front Cardiovasc Med ; 11: 1350345, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39055659

RESUMEN

Background: Simultaneous multi-slice (SMS) bSSFP imaging enables stress myocardial perfusion imaging with high spatial resolution and increased spatial coverage. Standard parallel imaging techniques (e.g., TGRAPPA) can be used for image reconstruction but result in high noise level. Alternatively, iterative reconstruction techniques based on temporal regularization (ITER) improve image quality but are associated with reduced temporal signal fidelity and long computation time limiting their online use. The aim is to develop an image reconstruction technique for SMS-bSSFP myocardial perfusion imaging combining parallel imaging and image-based denoising using a novel noise map estimation network (NoiseMapNet), which preserves both sharpness and temporal signal profiles and that has low computational cost. Methods: The proposed reconstruction of SMS images consists of a standard temporal parallel imaging reconstruction (TGRAPPA) with motion correction (MOCO) followed by image denoising using NoiseMapNet. NoiseMapNet is a deep learning network based on a 2D Unet architecture and aims to predict a noise map from an input noisy image, which is then subtracted from the noisy image to generate the denoised image. This approach was evaluated in 17 patients who underwent stress perfusion imaging using a SMS-bSSFP sequence. Images were reconstructed with (a) TGRAPPA with MOCO (thereafter referred to as TGRAPPA), (b) iterative reconstruction with integrated motion compensation (ITER), and (c) proposed NoiseMapNet-based reconstruction. Normalized mean squared error (NMSE) with respect to TGRAPPA, myocardial sharpness, image quality, perceived SNR (pSNR), and number of diagnostic segments were evaluated. Results: NMSE of NoiseMapNet was lower than using ITER for both myocardium (0.045 ± 0.021 vs. 0.172 ± 0.041, p < 0.001) and left ventricular blood pool (0.025 ± 0.014 vs. 0.069 ± 0.020, p < 0.001). There were no significant differences between all methods for myocardial sharpness (p = 0.77) and number of diagnostic segments (p = 0.36). ITER led to higher image quality than NoiseMapNet/TGRAPPA (2.7 ± 0.4 vs. 1.8 ± 0.4/1.3 ± 0.6, p < 0.001) and higher pSNR than NoiseMapNet/TGRAPPA (3.0 ± 0.0 vs. 2.0 ± 0.0/1.3 ± 0.6, p < 0.001). Importantly, NoiseMapNet yielded higher pSNR (p < 0.001) and image quality (p < 0.008) than TGRAPPA. Computation time of NoiseMapNet was only 20s for one entire dataset. Conclusion: NoiseMapNet-based reconstruction enables fast SMS image reconstruction for stress myocardial perfusion imaging while preserving sharpness and temporal signal profiles.

5.
Magn Reson Med ; 92(6): 2433-2446, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39075868

RESUMEN

PURPOSE: To develop a framework for simultaneous three-dimensional (3D) mapping of T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat signal fraction in the liver at 0.55 T. METHODS: The proposed sequence acquires four interleaved 3D volumes with a two-echo Dixon readout. T 1 $$ {\mathrm{T}}_1 $$ and T 2 $$ {\mathrm{T}}_2 $$ are encoded into each volume via preparation modules, and dictionary matching allows simultaneous estimation of T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and M 0 $$ {M}_0 $$ for water and fat separately. 2D image navigators permit respiratory binning, and motion fields from nonrigid registration between bins are used in a nonrigid respiratory-motion-corrected reconstruction, enabling 100% scan efficiency from a free-breathing acquisition. The integrated nature of the framework ensures the resulting maps are always co-registered. RESULTS: T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat-signal-fraction measurements in phantoms correlated strongly (adjusted r 2 > 0 . 98 $$ {r}^2>0.98 $$ ) with reference measurements. Mean liver tissue parameter values in 10 healthy volunteers were 427 ± 22 $$ 427\pm 22 $$ , 47 . 7 ± 3 . 3 ms $$ 47.7\pm 3.3\;\mathrm{ms} $$ , and 7 ± 2 % $$ 7\pm 2\% $$ for T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat signal fraction, giving biases of 71 $$ 71 $$ , - 30 . 0 ms $$ -30.0\;\mathrm{ms} $$ , and - 5 $$ -5 $$ percentage points, respectively, when compared to conventional methods. CONCLUSION: A novel sequence for comprehensive characterization of liver tissue at 0.55 T was developed. The sequence provides co-registered 3D T 1 $$ {\mathrm{T}}_1 $$ , T 2 $$ {\mathrm{T}}_2 $$ , and fat-signal-fraction maps with full coverage of the liver, from a single nine-and-a-half-minute free-breathing scan. Further development is needed to achieve accurate proton-density fat fraction (PDFF) estimation in vivo.


Asunto(s)
Tejido Adiposo , Algoritmos , Imagenología Tridimensional , Hígado , Imagen por Resonancia Magnética , Humanos , Hígado/diagnóstico por imagen , Imagenología Tridimensional/métodos , Tejido Adiposo/diagnóstico por imagen , Imagen por Resonancia Magnética/economía , Imagen por Resonancia Magnética/métodos , Movimiento (Física) , Fantasmas de Imagen , Respiración , Reproducibilidad de los Resultados , Procesamiento de Imagen Asistido por Computador/métodos , Masculino , Adulto , Interpretación de Imagen Asistida por Computador/métodos
6.
Eur Heart J Cardiovasc Imaging ; 25(10): 1374-1383, 2024 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-38723059

RESUMEN

AIMS: Standard methods of heart chamber volume estimation in cardiovascular magnetic resonance (CMR) typically utilize simple geometric formulae based on a limited number of slices. We aimed to evaluate whether an automated deep learning neural network prediction of 3D anatomy of all four chambers would show stronger associations with cardiovascular risk factors and disease than standard volume estimation methods in the UK Biobank. METHODS AND RESULTS: A deep learning network was adapted to predict 3D segmentations of left and right ventricles (LV, RV) and atria (LA, RA) at ∼1 mm isotropic resolution from CMR short- and long-axis 2D segmentations obtained from a fully automated machine learning pipeline in 4723 individuals with cardiovascular disease (CVD) and 5733 without in the UK Biobank. Relationships between volumes at end-diastole (ED) and end-systole (ES) and risk/disease factors were quantified using univariate, multivariate, and logistic regression analyses. Strength of association between deep learning volumes and standard volumes was compared using the area under the receiving operator characteristic curve (AUC). Univariate and multivariate associations between deep learning volumes and most risk and disease factors were stronger than for standard volumes (higher R2 and more significant P-values), particularly for sex, age, and body mass index. AUCs for all logistic regressions were higher for deep learning volumes than standard volumes (P < 0.001 for all four chambers at ED and ES). CONCLUSION: Neural network reconstructions of whole heart volumes had significantly stronger associations with CVD and risk factors than standard volume estimation methods in an automatic processing pipeline.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Cinemagnética , Humanos , Femenino , Masculino , Persona de Mediana Edad , Reino Unido , Imagen por Resonancia Cinemagnética/métodos , Anciano , Imagenología Tridimensional , Enfermedades Cardiovasculares/diagnóstico por imagen , Bancos de Muestras Biológicas , Biobanco del Reino Unido
7.
Int J Cardiovasc Imaging ; 40(6): 1363-1376, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38676848

RESUMEN

Contrast enhanced pulmonary vein magnetic resonance angiography (PV CE-MRA) has value in atrial ablation pre-procedural planning. We aimed to provide high fidelity, ECG gated PV CE-MRA accelerated by variable density Cartesian sampling (VD-CASPR) with image navigator (iNAV) respiratory motion correction acquired in under 4 min. We describe its use in part during the global iodinated contrast shortage. VD-CASPR/iNAV framework was applied to ECG-gated inversion and saturation recovery gradient recalled echo PV CE-MRA in 65 patients (66 exams) using .15 mmol/kg Gadobutrol. Image quality was assessed by three physicians, and anatomical segmentation quality by two technologists. Left atrial SNR and left atrial/myocardial CNR were measured. 12 patients had CTA within 6 months of MRA. Two readers assessed PV ostial measurements versus CTA for intermodality/interobserver agreement. Inter-rater/intermodality reliability, reproducibility of ostial measurements, SNR/CNR, image, and anatomical segmentation quality was compared. The mean acquisition time was 3.58 ± 0.60 min. Of 35 PV pre-ablation datasets (34 patients), mean anatomical segmentation quality score was 3.66 ± 0.54 and 3.63 ± 0.55 as rated by technologists 1 and 2, respectively (p = 0.7113). Good/excellent anatomical segmentation quality (grade 3/4) was seen in 97% of exams. Each rated one exam as moderate quality (grade 2). 95% received a majority image quality score of good/excellent by three physicians. Ostial PV measurements correlated moderate to excellently with CTA (ICCs range 0.52-0.86). No difference in SNR was observed between IR and SR. High quality PV CE-MRA is possible in under 4 min using iNAV bolus timing/motion correction and VD-CASPR.


Asunto(s)
Medios de Contraste , Interpretación de Imagen Asistida por Computador , Angiografía por Resonancia Magnética , Variaciones Dependientes del Observador , Compuestos Organometálicos , Valor Predictivo de las Pruebas , Venas Pulmonares , Humanos , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Venas Pulmonares/fisiopatología , Masculino , Femenino , Persona de Mediana Edad , Reproducibilidad de los Resultados , Medios de Contraste/administración & dosificación , Compuestos Organometálicos/administración & dosificación , Anciano , Técnicas de Imagen Sincronizada Cardíacas , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Ablación por Catéter , Electrocardiografía
8.
Front Physiol ; 15: 1327407, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38384795

RESUMEN

Introduction: Magnetic resonance elastography (MRE) is a non-invasive method to quantify biomechanical properties of human tissues. It has potential in diagnosis and monitoring of kidney disease, if established in clinical practice. The interplay of flow and volume changes in renal vessels, tubule, urinary collection system and interstitium is complex, but physiological ranges of in vivo viscoelastic properties during fasting and hydration have never been investigated in all gross anatomical segments simultaneously. Method: Ten healthy volunteers underwent two imaging sessions, one following a 12-hour fasting period and the second after a drinking challenge of >10 mL per kg body weight (60-75 min before the second examination). High-resolution renal MRE was performed using a novel driver with rotating eccentric mass placed at the posterior-lateral wall to couple waves (50 Hz) to the kidney. The biomechanical parameters, shear wave speed (cs in m/s), storage modulus (Gd in kPa), loss modulus (Gl in kPa), phase angle (Υ=2πatanGlGd) and attenuation (α in 1/mm) were derived. Accurate separation of gross anatomical segments was applied in post-processing (whole kidney, cortex, medulla, sinus, vessel). Results: High-quality shear waves coupled into all gross anatomical segments of the kidney (mean shear wave displacement: 163 ± 47 µm, mean contamination of second upper harmonics <23%, curl/divergence: 4.3 ± 0.8). Regardless of the hydration state, median Gd of the cortex and medulla (0.68 ± 0.11 kPa) was significantly higher than that of the sinus and vessels (0.48 ± 0.06 kPa), and consistently, significant differences were found in cs, Υ, and Gl (all p < 0.001). The viscoelastic parameters of cortex and medulla were not significantly different. After hydration sinus exhibited a small but significant reduction in median Gd by -0.02 ± 0.04 kPa (p = 0.01), and, consequently, the cortico-sinusoidal-difference in Gd increased by 0.04 ± 0.07 kPa (p = 0.05). Only upon hydration, the attenuation in vessels became lower (0.084 ± 0.013 1/mm) and differed significantly from the whole kidney (0.095 ± 0.007 1/mm, p = 0.01). Conclusion: High-resolution renal MRE with an innovative driver and well-defined 3D segmentation can resolve all renal segments, especially when including the sinus in the analysis. Even after a prolonged hydration period the approach is sensitive to small hydration-related changes in the sinus and in the cortico-sinusoidal-difference.

9.
J Cardiovasc Magn Reson ; 26(1): 101000, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38237902

RESUMEN

BACKGROUND: Myocardial quantitative susceptibility mapping (QSM) may offer better specificity to iron than conventional T2* imaging in the assessment of cardiac diseases, including intra-myocardial hemorrhage. However, the precision and repeatability of cardiac QSM have not yet been characterized. The aim of this study is to characterize these key metrics in a healthy volunteer cohort and show the feasibility of the method in patients. METHODS: Free breathing respiratory-navigated multi-echo 3D gradient echo images were acquired, from which QSM maps were reconstructed using the Morphology Enhanced Dipole Inversion toolbox. This technique was first evaluated in a susceptibility phantom containing tubes with known concentrations of gadolinium. In vivo characterization of myocardial QSM was then performed in a cohort of 10 healthy volunteers where each subject was scanned twice. Mean segment susceptibility, precision (standard deviation of voxel magnetic susceptibilities within one segment), and repeatability (absolute difference in segment mean susceptibility between repeats) of QSM were calculated for each American Heart Association (AHA) myocardial segment. Finally, the feasibility of the method was shown in 10 patients, including four with hemorrhagic infarcts. RESULTS: The phantom experiment showed a strong linear relationship between measured and predicted susceptibility shifts (R2 > 0.99). For the healthy volunteer cohort, AHA segment analysis showed the mean segment susceptibility was 0.00 ± 0.02 ppm, the mean precision was 0.05 ± 0.04 ppm, and the mean repeatability was 0.02 ± 0.02 ppm. Cardiac QSM was successfully performed in all patients. Focal iron deposits were successfully visualized in the patients with hemorrhagic myocardial infarctions. CONCLUSION: The precision and repeatability of cardiac QSM were successfully characterized in phantom and in vivo experiments. The feasibility of the technique was also successfully demonstrated in patients. While challenges still remain, further clinical evaluation of the technique is now warranted. TRIAL REGISTRATION: This work does not report on a health care intervention.


Asunto(s)
Estudios de Factibilidad , Ventrículos Cardíacos , Fantasmas de Imagen , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Persona de Mediana Edad , Adulto , Femenino , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Voluntarios Sanos , Imagen por Resonancia Magnética , Estudios de Casos y Controles , Anciano , Interpretación de Imagen Asistida por Computador , Medios de Contraste/administración & dosificación , Miocardio/patología , Adulto Joven , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/fisiopatología
10.
J Cardiovasc Magn Reson ; 26(1): 100008, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38194762

RESUMEN

BACKGROUND: Three dimensional, whole-heart (3DWH) MRI is an established non-invasive imaging modality in patients with congenital heart disease (CHD) for the diagnosis of cardiovascular morphology and for clinical decision making. Current techniques utilise diaphragmatic navigation (dNAV) for respiratory motion correction and gating and are frequently limited by long acquisition times. This study proposes and evaluates the diagnostic performance of a respiratory gating-free framework, which considers respiratory image-based navigation (iNAV), and highly accelerated variable density Cartesian sampling in concert with non-rigid motion correction and low-rank patch-based denoising (iNAV-3DWH-PROST). The method is compared to the clinical dNAV-3DWH sequence in adult patients with CHD. METHODS: In this prospective single center study, adult patients with CHD who underwent the clinical dNAV-3DWH MRI were also scanned with the iNAV-3DWH-PROST. Diagnostic confidence (4-point Likert scale) and diagnostic accuracy for common cardiovascular lesions was assessed by three readers. Scan times and diagnostic confidence were compared using the Wilcoxon-signed rank test. Co-axial vascular dimensions at three anatomic landmarks were measured, and agreement between the research and the corresponding clinical sequence was assessed with Bland-Altman analysis. RESULTS: The study included 60 participants (mean age ± [SD]: 33 ± 14 years; 36 men). The mean acquisition time of iNAV-3DWH-PROST was significantly lower compared with the conventional clinical sequence (3.1 ± 0.9 min vs 13.9 ± 3.9 min, p < 0.0001). Diagnostic confidence was higher for the iNAV-3DWH-PROST sequence compared with the clinical sequence (3.9 ± 0.2 vs 3.4 ± 0.8, p < 0.001), however there was no significant difference in diagnostic accuracy. Narrow limits of agreement and mean bias less than 0.08 cm were found between the research and the clinical vascular measurements. CONCLUSIONS: The iNAV-3DWH-PROST framework provides efficient, high quality and robust 3D whole-heart imaging in significantly shorter scan time compared to the standard clinical sequence.


Asunto(s)
Cardiopatías Congénitas , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/fisiopatología , Masculino , Adulto , Estudios Prospectivos , Femenino , Reproducibilidad de los Resultados , Persona de Mediana Edad , Factores de Tiempo , Adulto Joven , Interpretación de Imagen Asistida por Computador , Imagen por Resonancia Magnética , Respiración
11.
Magn Reson Med ; 91(6): 2403-2416, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38263908

RESUMEN

PURPOSE: The study aims to assess the potential of referenceless methods of EPI ghost correction to accelerate the acquisition of in vivo diffusion tensor cardiovascular magnetic resonance (DT-CMR) data using both computational simulations and data from in vivo experiments. METHODS: Three referenceless EPI ghost correction methods were evaluated on mid-ventricular short axis DT-CMR spin echo and STEAM datasets from 20 healthy subjects at 3T. The reduced field of view excitation technique was used to automatically quantify the Nyquist ghosts, and DT-CMR images were fit to a linear ghost model for correction. RESULTS: Numerical simulation showed the singular value decomposition (SVD) method is the least sensitive to noise, followed by Ghost/Object method and entropy-based method. In vivo experiments showed significant ghost reduction for all correction methods, with referenceless methods outperforming navigator methods for both spin echo and STEAM sequences at b = 32, 150, 450, and 600 smm - 2 $$ {\mathrm{smm}}^{-2} $$ . It is worth noting that as the strength of the diffusion encoding increases, the performance gap between the referenceless method and the navigator-based method diminishes. CONCLUSION: Referenceless ghost correction effectively reduces Nyquist ghost in DT-CMR data, showing promise for enhancing the accuracy and efficiency of measurements in clinical practice without the need for any additional reference scans.


Asunto(s)
Imagen Eco-Planar , Procesamiento de Imagen Asistido por Computador , Humanos , Imagen Eco-Planar/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Fantasmas de Imagen , Espectroscopía de Resonancia Magnética , Artefactos , Encéfalo , Algoritmos
12.
Magn Reson Med ; 91(5): 1951-1964, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38181169

RESUMEN

PURPOSE: Simultaneous PET-MRI improves inflammatory cardiac disease diagnosis. However, challenges persist in respiratory motion and mis-registration between free-breathing 3D PET and 2D breath-held MR images. We propose a free-breathing non-rigid motion-compensated 3D T2 -mapping sequence enabling whole-heart myocardial tissue characterization in a hybrid 3T PET-MR system and provides non-rigid respiratory motion fields to correct also simultaneously acquired PET data. METHODS: Free-breathing 3D whole-heart T2 -mapping was implemented on a hybrid 3T PET-MRI system. Three datasets were acquired with different T2 -preparation modules (0, 28, 55 ms) using 3-fold undersampled variable-density Cartesian trajectory. Respiratory motion was estimated via virtual 3D image navigators, enabling multi-contrast non-rigid motion-corrected MR reconstruction. T2 -maps were computed using dictionary-matching. Approach was tested in phantom, 8 healthy subjects, 14 MR only and 2 PET-MR patients with suspected cardiac disease and compared with spin echo reference (phantom) and clinical 2D T2 -mapping (in-vivo). RESULTS: Phantom results show a high correlation (R2 = 0.996) between proposed approach and gold standard 2D T2 mapping. In-vivo 3D T2 -mapping average values in healthy subjects (39.0 ± 1.4 ms) and patients (healthy tissue) (39.1 ± 1.4 ms) agree with conventional 2D T2 -mapping (healthy = 38.6 ± 1.2 ms, patients = 40.3 ± 1.7 ms). Bland-Altman analysis reveals bias of 1.8 ms and 95% limits of agreement (LOA) of -2.4-6 ms for healthy subjects, and bias of 1.3 ms and 95% LOA of -1.9 to 4.6 ms for patients. CONCLUSION: Validated efficient 3D whole-heart T2 -mapping at hybrid 3T PET-MRI provides myocardial inflammation characterization and non-rigid respiratory motion fields for simultaneous PET data correction. Comparable T2 values were achieved with both 3D and 2D methods. Improved image quality was observed in the PET images after MR-based motion correction.


Asunto(s)
Miocarditis , Miocardio , Humanos , Imagen por Resonancia Magnética , Movimiento (Física) , Imagenología Tridimensional/métodos , Tomografía de Emisión de Positrones , Corazón/diagnóstico por imagen , Fantasmas de Imagen
13.
Eur Radiol ; 34(4): 2689-2698, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37804340

RESUMEN

OBJECTIVES: Visualizing left atrial anatomy including the pulmonary veins (PVs) is important for planning the procedure of pulmonary vein isolation with ablation in patients with atrial fibrillation (AF). The aims of our study are to investigate the feasibility of the 3D whole-heart bright-blood and black-blood phase-sensitive (BOOST) inversion recovery sequence in patients with AF scheduled for ablation or electro-cardioversion, and to analyze the correlation between image quality and heart rate and rhythm of patients. METHODS: BOOST was performed for assessing PVs both with T2 preparation pre-pulse (T2prep) and magnetization transfer preparation (MTC) in 45 patients with paroxysmal or permanent AF scheduled for ablation or electro-cardioversion. Image quality analyses were performed by two independent observers. Qualitative assessment was made using the Likert scale; for quantitative analysis, signal to noise ratios (SNR) and contrast to noise ratios (CNR) were calculated for each PV. Heart rate and rhythm were analyzed based on standard 12-lead ECGs. RESULTS: All MTC-BOOST acquisitions achieved diagnostic quality in the PVs, while a significant proportion of T2prep-BOOST images were not suitable for assessing PVs. SNR and CNR values of the MTC-BOOST bright-blood images were higher if patients had sinus rhythm. We found a significant or nearly significant negative correlation between heart rate and the SNR and CNR values of MTC-BOOST bright-blood images. CONCLUSION: 3D whole-heart MTC-BOOST bright-blood imaging is suitable for visualizing the PVs in patients with AF, producing diagnostic image quality in 100% of cases. However, image quality was influenced by heart rate and rhythm. CLINICAL RELEVANCE STATEMENT: The novel 3D whole-heart BOOST CMR sequence needs no contrast administration and is performed during free-breathing; therefore, it is easy to use for a wide range of patients and is suitable for visualizing the PVs in patients with AF. KEY POINTS: • The applicability of the novel 3D whole-heart bright-blood and black-blood phase-sensitive sequence to pulmonary vein imaging in clinical practice is unknown. • Magnetization transfer-bright-blood and black-blood phase-sensitive imaging is suitable for visualizing the pulmonary veins in patients with atrial fibrillation with excellent or good image quality. • Bright-blood and black-blood phase-sensitive cardiac magnetic resonance sequence is easy to use for a wide range of patients as it needs no contrast administration and is performed during free-breathing.


Asunto(s)
Fibrilación Atrial , Ablación por Catéter , Venas Pulmonares , Humanos , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/cirugía , Estudios de Factibilidad , Atrios Cardíacos/diagnóstico por imagen , Electrocardiografía , Imagen por Resonancia Magnética , Venas Pulmonares/diagnóstico por imagen , Venas Pulmonares/cirugía , Ablación por Catéter/métodos
14.
Magn Reson Med ; 91(1): 388-397, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37676923

RESUMEN

PURPOSE: MR-guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium-filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real-time catheter tracking during MR-guided cardiac catheterization is presented. METHODS: The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10-20 contiguous saturated slices combined with real-time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR-guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated. RESULTS: The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real-time measurements in the phantom and patients, respectively. CONCLUSION: The proposed framework enabled real-time continuous automatic tracking of a gadolinium-filled catheter balloon during MR-guided cardiac catheterization.


Asunto(s)
Cateterismo Cardíaco , Gadolinio , Humanos , Cateterismo Cardíaco/métodos , Catéteres , Fantasmas de Imagen , Corazón
15.
J Cardiovasc Magn Reson ; 25(1): 80, 2023 12 20.
Artículo en Inglés | MEDLINE | ID: mdl-38124106

RESUMEN

BACKGROUND: Quantification of three-dimensional (3D) cardiac anatomy is important for the evaluation of cardiovascular diseases. Changes in anatomy are indicative of remodeling processes as the heart tissue adapts to disease. Although robust segmentation methods exist for computed tomography angiography (CTA), few methods exist for whole-heart cardiovascular magnetic resonance angiograms (CMRA) which are more challenging due to variable contrast, lower signal to noise ratio and a limited amount of labeled data. METHODS: Two state-of-the-art unsupervised generative deep learning domain adaptation architectures, generative adversarial networks and variational auto-encoders, were applied to 3D whole heart segmentation of both conventional (n = 20) and high-resolution (n = 45) CMRA (target) images, given segmented CTA (source) images for training. An additional supervised loss function was implemented to improve performance given 10%, 20% and 30% segmented CMRA cases. A fully supervised nn-UNet trained on the given CMRA segmentations was used as the benchmark. RESULTS: The addition of a small number of segmented CMRA training cases substantially improved performance in both generative architectures in both standard and high-resolution datasets. Compared with the nn-UNet benchmark, the generative methods showed substantially better performance in the case of limited labelled cases. On the standard CMRA dataset, an average 12% (adversarial method) and 10% (variational method) improvement in Dice score was obtained. CONCLUSIONS: Unsupervised domain-adaptation methods for CMRA segmentation can be boosted by the addition of a small number of supervised target training cases. When only few labelled cases are available, semi-supervised generative modelling is superior to supervised methods.


Asunto(s)
Enfermedades Cardiovasculares , Sistema Cardiovascular , Humanos , Angiografía por Resonancia Magnética , Valor Predictivo de las Pruebas , Corazón , Procesamiento de Imagen Asistido por Computador
16.
J Cardiovasc Magn Reson ; 25(1): 52, 2023 10 02.
Artículo en Inglés | MEDLINE | ID: mdl-37779192

RESUMEN

BACKGROUND: Coronary magnetic resonance angiography (coronary MRA) is increasingly being considered as a clinically viable method to investigate coronary artery disease (CAD). Accurate determination of the trigger delay to place the acquisition window within the quiescent part of the cardiac cycle is critical for coronary MRA in order to reduce cardiac motion. This is currently reliant on operator-led decision making, which can negatively affect consistency of scan acquisition. Recently developed deep learning (DL) derived software may overcome these issues by automation of cardiac rest period detection. METHODS: Thirty individuals (female, n = 10) were investigated using a 0.9 mm isotropic image-navigator (iNAV)-based motion-corrected coronary MRA sequence. Each individual was scanned three times utilising different strategies for determination of the optimal trigger delay: (1) the DL software, (2) an experienced operator decision, and (3) a previously utilised formula for determining the trigger delay. Methodologies were compared using custom-made analysis software to assess visible coronary vessel length and coronary vessel sharpness for the entire vessel length and the first 4 cm of each vessel. RESULTS: There was no difference in image quality between any of the methodologies for determination of the optimal trigger delay, as assessed by visible coronary vessel length, coronary vessel sharpness for each entire vessel and vessel sharpness for the first 4 cm of the left mainstem, left anterior descending or right coronary arteries. However, vessel length of the left circumflex was slightly greater using the formula method. The time taken to calculate the trigger delay was significantly lower for the DL-method as compared to the operator-led approach (106 ± 38.0 s vs 168 ± 39.2 s, p < 0.01, 95% CI of difference 25.5-98.1 s). CONCLUSIONS: Deep learning-derived automated software can effectively and efficiently determine the optimal trigger delay for acquisition of coronary MRA and thus may simplify workflow and improve reproducibility.


Asunto(s)
Corazón , Angiografía por Resonancia Magnética , Humanos , Femenino , Angiografía por Resonancia Magnética/métodos , Reproducibilidad de los Resultados , Valor Predictivo de las Pruebas , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/patología , Angiografía Coronaria/métodos , Imagenología Tridimensional
17.
Front Cardiovasc Med ; 10: 1233065, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37859681

RESUMEN

Radiofrequency catheter ablation is an established treatment strategy for ventricular tachycardia, but remains associated with a low success rate. MR guidance of ventricular tachycardia shows promises to improve the success rate of these procedures, especially due to its potential to provide real-time information on lesion formation using cardiac MR thermometry. Modern low field MRI scanners (<1 T) are of major interest for MR-guided ablations as the potential benefits include lower costs, increased patient access and device compatibility through reduced device-induced imaging artefacts and safety constraints. However, the feasibility of cardiac MR thermometry at low field remains unknown. In this study, we demonstrate the feasibility of cardiac MR thermometry at 0.55 T and characterized its in vivo stability (i.e., precision) using state-of-the-art techniques based on the proton resonance frequency shift method. Nine healthy volunteers were scanned using a cardiac MR thermometry protocol based on single-shot EPI imaging (3 slices in the left ventricle, 150 dynamics, TE = 41 ms). The reconstruction pipeline included image registration to align all the images, multi-baseline approach (look-up-table length = 30) to correct for respiration-induced phase variations, and temporal filtering to reduce noise in temperature maps. The stability of thermometry was defined as the pixel-wise standard deviation of temperature changes over time. Cardiac MR thermometry was successfully acquired in all subjects and the stability averaged across all subjects was 1.8 ± 1.0°C. Without multi-baseline correction, the overall stability was 2.8 ± 1.6°C. In conclusion, cardiac MR thermometry is feasible at 0.55 T and further studies on MR-guided catheter ablations at low field are warranted.

18.
Front Cardiovasc Med ; 10: 1233093, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37745095

RESUMEN

Introduction: Magnetic Resonance Imaging (MRI) is a promising alternative to standard x-ray fluoroscopy for the guidance of cardiac catheterization procedures as it enables soft tissue visualization, avoids ionizing radiation and provides improved hemodynamic data. MRI-guided cardiac catheterization procedures currently require frequent manual tracking of the imaging plane during navigation to follow the tip of a gadolinium-filled balloon wedge catheter, which unnecessarily prolongs and complicates the procedures. Therefore, real-time automatic image-based detection of the catheter balloon has the potential to improve catheter visualization and navigation through automatic slice tracking. Methods: In this study, an automatic, parameter-free, deep-learning-based post-processing pipeline was developed for real-time detection of the catheter balloon. A U-Net architecture with a ResNet-34 encoder was trained on semi-artificial images for the segmentation of the catheter balloon. Post-processing steps were implemented to guarantee a unique estimate of the catheter tip coordinates. This approach was evaluated retrospectively in 7 patients (6M and 1F, age = 7 ± 5 year) who underwent an MRI-guided right heart catheterization procedure with all images acquired in an orientation unseen during training. Results: The overall accuracy, specificity and sensitivity of the proposed catheter tracking strategy over all 7 patients were 98.4 ± 2.0%, 99.9 ± 0.2% and 95.4 ± 5.5%, respectively. The computation time of the deep-learning-based segmentation step was ∼10 ms/image, indicating its compatibility with real-time constraints. Conclusion: Deep-learning-based catheter balloon tracking is feasible, accurate, parameter-free, and compatible with real-time conditions. Online integration of the technique and its evaluation in a larger patient cohort are now warranted to determine its benefit during MRI-guided cardiac catheterization.

19.
Magn Reson Med ; 90(6): 2306-2320, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37465882

RESUMEN

PURPOSE: To improve motion robustness of functional fetal MRI scans by developing an intrinsic real-time motion correction method. MRI provides an ideal tool to characterize fetal brain development and growth. It is, however, a relatively slow imaging technique and therefore extremely susceptible to subject motion, particularly in functional MRI experiments acquiring multiple Echo-Planar-Imaging-based repetitions, for example, diffusion MRI or blood-oxygen-level-dependency MRI. METHODS: A 3D UNet was trained on 125 fetal datasets to track the fetal brain position in each repetition of the scan in real time. This tracking, inserted into a Gadgetron pipeline on a clinical scanner, allows updating the position of the field of view in a modified echo-planar imaging sequence. The method was evaluated in real-time in controlled-motion phantom experiments and ten fetal MR studies (17 + 4-34 + 3 gestational weeks) at 3T. The localization network was additionally tested retrospectively on 29 low-field (0.55T) datasets. RESULTS: Our method achieved real-time fetal head tracking and prospective correction of the acquisition geometry. Localization performance achieved Dice scores of 84.4% and 82.3%, respectively for both the unseen 1.5T/3T and 0.55T fetal data, with values higher for cephalic fetuses and increasing with gestational age. CONCLUSIONS: Our technique was able to follow the fetal brain even for fetuses under 18 weeks GA in real-time at 3T and was successfully applied "offline" to new cohorts on 0.55T. Next, it will be deployed to other modalities such as fetal diffusion MRI and to cohorts of pregnant participants diagnosed with pregnancy complications, for example, pre-eclampsia and congenital heart disease.


Asunto(s)
Feto , Imagen por Resonancia Magnética , Femenino , Humanos , Embarazo , Estudios Prospectivos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Feto/diagnóstico por imagen , Encéfalo/diagnóstico por imagen , Movimiento (Física)
20.
Front Cardiovasc Med ; 10: 1177347, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37396587

RESUMEN

Introduction: Left atrial appendage (LAA) thrombus is the most common source of embolization in atrial fibrillation (AF). Transesophageal echocardiography (TEE) is the gold standard method for LAA thrombus exclusion. Our pilot study aimed to compare the efficacy of a new non-contrast-enhanced cardiac magnetic resonance (CMR) sequence (BOOST) with TEE for the detection of LAA thrombus and to evaluate the usefulness of BOOST images for planning radiofrequency catheter ablation (RFCA) compared with left atrial (LA) contrast-enhanced computed tomography (CT). We also attempted to assess the patients' subjective experiences with TEE and CMR. Methods: Patients with AF undergoing either electrical cardioversion or RFCA were enrolled. Participants underwent pre-procedural TEE and CMR scans to evaluate LAA thrombus status and pulmonary vein anatomy. Patient experiences with TEE and CMR were assessed using a questionnaire developed by our team. Some patients scheduled for RFCA also had pre-procedural LA contrast-enhanced CT. In such cases, the operating physician was asked to subjectively define the quality of the CT and CMR scan on a scale of 1-10 (1 = worst, 10 = best) and comment on CMR's usefulness in RFCA planning. Results: Seventy-one patients were enrolled. In 94.4%, both TEE and CMR excluded, and in 1 patient, both modalities reported the presence of LAA thrombus. In 1 patient, TEE was inconclusive, but CMR excluded LAA thrombus. In 2 patients, CMR could not exclude the presence of thrombus, but in 1 of those cases, TEE was also indecisive. During TEE, 67%, during CMR, only 1.9% of patients reported pain (p < 0.0001), and 89% would prefer CMR in case of a repeat examination. The quality of the left atrial contrast-enhanced CT scans was better compared with the image quality of the CMR BOOST sequence [8 (7-9) vs. 6 (5-7), p < 0.0001]. Still, the CMR images were useful for procedural planning in 91% of cases. Conclusion: The new CMR BOOST sequence provides appropriate image quality for ablation planning. The sequence might be useful for excluding larger LAA thrombi; however, its accuracy in detecting smaller thrombi is limited. Most patients preferred CMR over TEE in this indication.