Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros











Base de datos
Intervalo de año de publicación
1.
Mil Med ; 189(Supplement_3): 83-92, 2024 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-39160844

RESUMEN

INTRODUCTION: Continuous extracorporeal perfusion (ECP), or machine perfusion, holds promise for prolonged skeletal muscle preservation in limb ischemia-reperfusion injury. This study aimed to extend the amputation-to-replantation time window from currently 6 hours to 33 hours using a 24-hour ECP approach. MATERIALS AND METHODS: Six large white pigs underwent surgical forelimb amputation under general anesthesia. After amputation, limbs were kept for 9 hours at room temperature and then perfused by 24-hour ECP with a modified histidine-tryptophan-ketoglutarate (HTK) solution. After ECP, limbs were orthotopically replanted and perfused in vivo for 12 hours. Clinical data, blood, and tissue samples were collected and analyzed. RESULTS: All 6 forelimbs could be successfully replanted and in vivo reperfused for 12 hours after 9 hours of room temperature ischemia followed by 24 hours ECP. Adequate limb perfusion was observed after replantation as shown by thermography and laser Doppler imaging. All pigs survived without severe organ failure, and no significant increase in inflammatory cytokines was found. Macroscopy and histology showed marked interstitial muscular edema of the limbs, whereas myofiber necrosis was not evident, implying the preservation of muscular integrity. CONCLUSIONS: The use of a 24-hour ECP has successfully extended limb preservation to 33 hours. The modified histidine-tryptophan-ketoglutarate perfusate demonstrated its ability for muscle protection. This innovative approach not only facilitates limb replantation after combat injuries, surmounting geographical barriers, but also broadens the prospects for well-matched limb allotransplants across countries and continents.


Asunto(s)
Amputación Traumática , Reimplantación , Animales , Reimplantación/métodos , Porcinos , Amputación Traumática/cirugía , Factores de Tiempo , Perfusión/métodos , Procaína/farmacología , Procaína/uso terapéutico , Cloruro de Potasio/farmacología , Cloruro de Potasio/uso terapéutico , Daño por Reperfusión , Miembro Anterior/fisiopatología , Glucosa , Manitol
2.
Front Cardiovasc Med ; 11: 1325160, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38938649

RESUMEN

Background: During donation after circulatory death (DCD), cardiac grafts are exposed to potentially damaging conditions that can impact their quality and post-transplantation outcomes. In a clinical DCD setting, patients have closed chests in most cases, while many experimental models have used open-chest conditions. We therefore aimed to investigate and characterize differences in open- vs. closed-chest porcine models. Methods: Withdrawal of life-sustaining therapy (WLST) was simulated in anesthetized juvenile male pigs by stopping mechanical ventilation following the administration of a neuromuscular block. Functional warm ischemic time (fWIT) was defined to start when systolic arterial pressure was <50 mmHg. Hemodynamic changes and blood chemistry were analyzed. Two experimental groups were compared: (i) an open-chest group with sternotomy prior to WLST and (ii) a closed-chest group with sternotomy after fWIT. Results: Hemodynamic changes during the progression from WLST to fWIT were initiated by a rapid decline in blood oxygen saturation and a subsequent cardiovascular hyperdynamic (HD) period characterized by temporary elevations in heart rates and arterial pressures in both groups. Subsequently, heart rate and systolic arterial pressure decreased until fWIT was reached. Pigs in the open-chest group displayed a more rapid transition to the HD phase after WLST, with peak heart rate and peak rate-pressure product occurring significantly earlier. Furthermore, the HD phase duration tended to be shorter and less intense (lower peak rate-pressure product) in the open-chest group than in the closed-chest group. Discussion: Progression from WLST to fWIT was more rapid, and the hemodynamic changes tended to be less pronounced in the open-chest group than in the closed-chest group. Our findings support clear differences between open- and closed-chest models of DCD. Therefore, recommendations for clinical DCD protocols based on findings in open-chest models must be interpreted with care.

3.
Am J Physiol Lung Cell Mol Physiol ; 324(2): L102-L113, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36511508

RESUMEN

Assessment of native cardiac output during extracorporeal circulation is challenging. We assessed a modified Fick principle under conditions such as dead space and shunt in 13 anesthetized swine undergoing centrally cannulated veno-arterial extracorporeal membrane oxygenation (V-A ECMO, 308 measurement periods) therapy. We assumed that the ratio of carbon dioxide elimination (V̇co2) or oxygen uptake (V̇o2) between the membrane and native lung corresponds to the ratio of respective blood flows. Unequal ventilation/perfusion (V̇/Q̇) ratios were corrected towards unity. Pulmonary blood flow was calculated and compared to an ultrasonic flow probe on the pulmonary artery with a bias of 99 mL/min (limits of agreement -542 to 741 mL/min) with blood content V̇o2 and no-shunt, no-dead space conditions, which showed good trending ability (least significant change from 82 to 129 mL). Shunt conditions led to underestimation of native pulmonary blood flow (bias -395, limits of agreement -1,290 to 500 mL/min). Bias and trending further depended on the gas (O2, CO2) and measurement approach (blood content vs. gas phase). Measurements in the gas phase increased the bias (253 [LoA -1,357 to 1,863 mL/min] for expired V̇o2 bias 482 [LoA -760 to 1,724 mL/min] for expired V̇co2) and could be improved by correction of V̇/Q̇ inequalities. Our results show that common assumptions of the Fick principle in two competing circulations give results with adequate accuracy and may offer a clinically applicable tool. Precision depends on specific conditions. This highlights the complexity of gas exchange in membrane lungs and may further deepen the understanding of V-A ECMO.


Asunto(s)
Oxigenación por Membrana Extracorpórea , Intercambio Gaseoso Pulmonar , Animales , Porcinos , Intercambio Gaseoso Pulmonar/fisiología , Oxigenación por Membrana Extracorpórea/métodos , Pulmón/irrigación sanguínea , Gasto Cardíaco/fisiología , Arteria Pulmonar , Dióxido de Carbono
4.
Anesthesiology ; 133(4): 879-891, 2020 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-32657798

RESUMEN

BACKGROUND: Veno-arterial extracorporeal membrane oxygenation therapy is a growing treatment modality for acute cardiorespiratory failure. Cardiac output monitoring during veno-arterial extracorporeal membrane oxygenation therapy remains challenging. This study aims to validate a new thermodilution technique during veno-arterial extracorporeal membrane oxygenation therapy using a pig model. METHODS: Sixteen healthy pigs were centrally cannulated for veno-arterial extracorporeal membrane oxygenation, and precision flow probes for blood flow assessment were placed on the pulmonary artery. After chest closure, cold boluses of 0.9% saline solution were injected into the extracorporeal membrane oxygenation circuit, right atrium, and right ventricle at different extracorporeal membrane oxygenation flows (4, 3, 2, 1 l/min). Rapid response thermistors in the extracorporeal membrane oxygenation circuit and pulmonary artery recorded the temperature change. After calculating catheter constants, the distributions of injection volumes passing each circuit were assessed and enabled calculation of pulmonary blood flow. Analysis of the exponential temperature decay allowed assessment of right ventricular function. RESULTS: Calculated blood flow correlated well with measured blood flow (r2 = 0.74, P < 0.001). Bias was -6 ml/min [95% CI ± 48 ml/min] with clinically acceptable limits of agreement (668 ml/min [95% CI ± 166 ml/min]). Percentage error varied with extracorporeal membrane oxygenation blood flow reductions, yielding an overall percentage error of 32.1% and a percentage error of 24.3% at low extracorporeal membrane oxygenation blood flows. Right ventricular ejection fraction was 17 [14 to 20.0]%. Extracorporeal membrane oxygenation flow reductions increased end-diastolic and end-systolic volumes with reductions in pulmonary vascular resistance. Central venous pressure and right ventricular ejection fractions remained unchanged. End-diastolic and end-systolic volumes correlated highly (r2 = 0.98, P < 0.001). CONCLUSIONS: Adapted thermodilution allows reliable assessment of cardiac output and right ventricular behavior. During veno-arterial extracorporeal membrane oxygenation weaning, the right ventricle dilates even with stable function, possibly because of increased venous return.


Asunto(s)
Velocidad del Flujo Sanguíneo/fisiología , Oxigenación por Membrana Extracorpórea/métodos , Modelos Animales , Termodilución/métodos , Función Ventricular Derecha/fisiología , Animales , Femenino , Pulmón/irrigación sanguínea , Pulmón/fisiología , Masculino , Porcinos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA