Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Australas Phys Eng Sci Med ; 40(2): 317-324, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28243922

RESUMEN

Intrafraction prostate motion degrades the accuracy of radiation therapy (RT) delivery. Whilst a number of metrics in the literature have been used to quantify intrafraction prostate motion, it has not been established whether these metrics reflect the effect of motion on the RT dose delivered to the patients. In this study, prostate motion during volumetric modulated arc therapy (VMAT) treatment of 18 patients and a total of 294 fractions was quantified through novel metrics as well as those available in the literature. The impact of the motion on VMAT dosimetry was evaluated using these metrics and dose reconstructions based on a previously validated and published method. The dosimetric impact of the motion on planning target volume (PTV) and clinical target volume (CTV) coverage and organs at risk (OARs) was correlated with the motion metrics, using the coefficient of determination (R 2 ), to evaluate their utility. Action level threshold for the prostate motion metric that best described the dosimetric impact on the PTV D95% was investigated through iterative regression analysis. The average (range) of the mean motion for the patient cohort was 1.5 mm (0.3-9.9 mm). A number of motion metrics were found to be strongly correlated with PTV D95%, the range of R 2 was 0.43-0.81. For all the motion measures, correlations with CTV D99% (range of R 2 was 0.12-0.62), rectum V65% (range of R 2 was 0.33-0.58) and bladder V65% (range of R 2 was 0.51-0.69) were not as strong as for PTV D95%. The mean of the highest 50% of motion metric was one of the best indicator of dosimetric impact on PTV D95%. Action level threshold value for this metric was found to be 3.0 mm. For an individual fraction, when the metric value was greater than 3.0 mm then the PTV D95% was reduced on average by 6.2%. This study demonstrated that several motion metrics are well correlated with the dosimetric impact (PTV D95%) of individual fraction prostate motion on VMAT delivery and could be used for treatment course adaptation.


Asunto(s)
Movimiento (Física) , Próstata/efectos de la radiación , Dosificación Radioterapéutica , Radioterapia de Intensidad Modulada , Estudios de Cohortes , Relación Dosis-Respuesta en la Radiación , Humanos , Imagenología Tridimensional , Masculino
2.
Radiat Oncol ; 10: 215, 2015 Oct 24.
Artículo en Inglés | MEDLINE | ID: mdl-26499473

RESUMEN

BACKGROUND AND PURPOSE: The use of a tissue expander (hydrogel) for sparing of the rectum from increased irradiation during prostate radiotherapy is becoming popular. The goal of this study is to investigate the effect of a tissue expander (hydrogel) on the intrafraction prostate motion during radiotherapy. METHODS AND MATERIAL: Real time prostate motion was analysed for 26 patients and 742 fractions; 12 patients with and 14 patients without hydrogel (SpaceOAR™). The intra-fraction motion was quantified and compared between the two groups. RESULTS: The average (±standard deviation) of the mean motion during the treatment for patients with and without hydrogel was 1.5 (±0.8 mm) and 1.1 (±0.9 mm) respectively (p < 0.05). The average time of motion >3 mm for patients with and without hydrogel was 7.7 % (±1.1 %) and 4.5 % (±0.9 %) respectively (p > 0.05). The hydrogel age, fraction number and treatment time were found to have no effect (R (2) < 0.05) on the prostate motion. CONCLUSIONS: Differences in intrafraction motion in patients with hydrogel and without hydrogel were within measurement uncertainty (<1 mm). This result confirms that the addition of a spacer does not negate the need for intrafraction motion management if clinically indicated.


Asunto(s)
Neoplasias de la Próstata/radioterapia , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Planificación de la Radioterapia Asistida por Computador/métodos , Dispositivos de Expansión Tisular , Humanos , Hidrogel de Polietilenoglicol-Dimetacrilato , Masculino , Movimiento (Física) , Radioterapia de Intensidad Modulada/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...