Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Int J Oral Maxillofac Implants ; 32(1): 70-80, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-27706264

RESUMEN

PURPOSE: To compare the three-dimensional (3D) accuracy of conventional direct implant impressions with digital implant impressions from three intraoral scanners, as well as different implant levels-bone level (BL) and tissue level (TL). MATERIALS AND METHODS: Two-implant master models were used to simulate a threeunit implant-supported fixed dental prosthesis. Conventional test models were made with direct impression copings and polyether impressions. Scan bodies were hand-tightened onto master models and scanned with the three scanners. This was done for the TL and BL test groups, for a total of eight test groups (n = 5 each). A coordinate measuring machine measured linear distortions (dx, dy, dz), global linear distortion (dR), angular distortions (dθy, dθx), and absolute angular distortions (Absdθy, Absdθx) between the master models, test models, and .stl files of the digital scans. RESULTS: The mean dR ranged from 35 to 66 µm; mean dθy angular distortions ranged from -0.186 to 0.315 degrees; and mean dθx angular distortions ranged from -0.206 to 0.164 degrees. Two-way analysis of variance showed that the impression type had a significant effect on dx, dz, and Absdθy, and the implant level had a significant effect on dx and Absdθx (P < .05). Among the BL groups, the mean dR of the conventional group was lower than and significantly different from the digital test groups (P = .010), while among the TL groups, there was no statistically significant difference (P = .572). CONCLUSION: The 3D accuracy of implant impressions varied according to the impression technique and implant level. For BL test groups, the conventional impression group had significantly lower distortion than the digital impression groups. Among the digital test groups, the TR system had comparable mean linear and absolute angular distortions to the other two systems but exhibited the smallest standard deviations.

2.
Int J Oral Maxillofac Implants ; 29(4): 927-36, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25032774

RESUMEN

PURPOSE: This study examined the three-dimensional (3D) accuracy of the Encode Impression System (EN) in transferring the locations of two implants from master models to test models and compared this to the direct impression (DI) technique. The effect of interimplant angulation on the 3D accuracy of both impression techniques was also evaluated. MATERIALS AND METHODS: Seven sectional polymethyl methacrylate mandibular arch master models were fabricated with implants in the first premolar and first molar positions. The implants were placed parallel to each other or angulated mesiodistally or buccolingually with total divergent angles of 10, 20, or 30 degrees. Each master model was secured onto an aluminum block containing a gauge block, which defined the local coordinate references. Encode healing abutments were attached to the implants before impressions were made for the EN test models; pickup impression copings were attached for the DI test models. For the seven test groups of each impression technique, a total of 70 test models were fabricated (n = 5). The EN test models were sent to Biomet 3i for implant analog placement. The centroid of each implant or implant analog and the angular orientation of the long axis relative to the x- and y-axes were measured with a coordinate measuring machine. Statistical analyses were performed. RESULTS: Impression technique had a significant effect on y distortion, global linear distortion, and absolute xz and yz angular distortions. Interimplant angulation had significant effects on x and y distortions. However, neither impression technique nor interimplant angulation had a significant effect on z distortion. CONCLUSIONS: Distortions were observed with both impression techniques. However, the results suggest that EN was less accurate than DI.


Asunto(s)
Diseño Asistido por Computadora , Pilares Dentales/normas , Técnica de Impresión Dental/normas , Implantes Dentales , Materiales de Impresión Dental , Humanos , Modelos Dentales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...