Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Afr J Lab Med ; 12(1): 1974, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36756215

RESUMEN

Introduction: Determining the HIV status of some individuals remains challenging due to multidimensional factors such as flaws in diagnostic systems, technological challenges, and viral diversity. This report pinpoints challenges faced by the HIV testing system in Cameroon. Case presentation: A 53-year-old male received a positive HIV result by a rapid testing algorithm in July 2016. Not convinced of his HIV status, he requested additional tests. In February 2017, he received a positive result using ImmunoComb® II HIV 1 & 2 BiSpot and Roche cobas electrochemiluminescence assays. A sample sent to France in April 2017 was positive on the Bio-Rad GenScreen™ HIV 1/2, but serotyping was indeterminate, and viral load was < 20 copies/mL. The Roche electrochemiluminescence immunoassay and INNO-LIA HIV I/II Score were negative for samples collected in 2018. A sample collected in July 2019 and tested with VIDAS® HIV Duo Ultra enzyme-linked fluorescent assay and Geenius™ HIV 1/2 Confirmatory Assay was positive, but negative with Western blot; CD4 count was 1380 cells/mm3 and HIV proviral DNA tested in France was 'target-not-detected'. Some rapid tests were still positive in 2020 and 2021. Serotyping remained indeterminate, and viral load was 'target-not-detected'. There were no self-reported exposure to HIV risk factors, and his wife was HIV-seronegative. Management and outcome: Given that the patient remained asymptomatic with no evidence of viral replication, no antiretroviral therapy was initiated. Conclusion: This case highlights the struggles faced by some individuals in confirming their HIV status and the need to update existing technologies and develop an algorithm for managing exceptional cases.

2.
Afr. j. lab. med. (Online) ; 12(1): 1-4, 2023. figures
Artículo en Inglés | AIM (África) | ID: biblio-1413499

RESUMEN

Introduction: Determining the HIV status of some individuals remains challenging due to multidimensional factors such as flaws in diagnostic systems, technological challenges, and viral diversity. This report pinpoints challenges faced by the HIV testing system in Cameroon. Case presentation: A 53-year-old male received a positive HIV result by a rapid testing algorithm in July 2016. Not convinced of his HIV status, he requested additional tests. In February 2017, he received a positive result using ImmunoComb® II HIV 1 & 2 BiSpot and Roche cobas electrochemiluminescence assays. A sample sent to France in April 2017 was positive on the Bio-Rad GenScreen™ HIV 1/2, but serotyping was indeterminate, and viral load was < 20 copies/mL. The Roche electrochemiluminescence immunoassay and INNO-LIA HIV I/II Score were negative for samples collected in 2018. A sample collected in July 2019 and tested with VIDAS® HIV Duo Ultra enzyme-linked fluorescent assay and Geenius™ HIV 1/2 Confirmatory Assay was positive, but negative with Western blot; CD4 count was 1380 cells/mm3 and HIV proviral DNA tested in France was 'target-not-detected'. Some rapid tests were still positive in 2020 and 2021. Serotyping remained indeterminate, and viral load was 'target-not-detected'. There were no self-reported exposure to HIV risk factors, and his wife was HIV-seronegative.Management and outcome: Given that the patient remained asymptomatic with no evidence of viral replication, no antiretroviral therapy was initiated. Conclusion: This case highlights the struggles faced by some individuals in confirming their HIV status and the need to update existing technologies and develop an algorithm for managing exceptional cases.

3.
Virol J ; 16(1): 101, 2019 08 09.
Artículo en Inglés | MEDLINE | ID: mdl-31399103

RESUMEN

BACKGROUND: Current HCV treatments are genotype specific although potential pan-genotype treatments have recently been described. Therefore, genotyping is an essential tool for the therapeutic management of HCV infection and a variety of technologies have been developed for HCV genotypes determination. Sequences analysis of HCV sub-genomic regions is considered as gold standard and is widely used for HCV genotyping. Here, we compared HCV genotyping using core and NS5B regions in routine practice in HCV-positive Cameroonian patients. METHODS: All plasma samples received at Centre Pasteur of Cameroon (CPC) in 2016 for HCV genotyping were included. Viral loads were determined using the Abbott Real Time assay. Further, genotyping was based on the amplification and sequencing of core and NS5B regions following by phylogenetic analysis of corresponding sequences. RESULTS: A total of 369 samples were received during the study period with high viral load values (median: 930,952 IU/ml; IQR: 281,833-2,861,179). Positive amplification was obtained in at least one genomic region (core or NS5B) for all the samples with similar amplification rate in the two genomic regions (p = 0.34). Phylogenetic analysis showed that among the 369 samples, 146 (39.6%) were classified as genotype 4, 132 (35.8%) as genotype 1, 89 (24.1%) as genotype 2, in both core and NS5B regions. Interestingly, for two samples (0.54%) discordant genotypes were obtained in both regions with the core region classified as genotype 4 while the NS5B was identified as genotype 1 indicating the presence of putative HCV recombinant virus or multiple infections in these samples. Discrimination of HCV subtypes was most likely possible with NS5B compared to core region. CONCLUSIONS: We found high amplification rates of HCV in both core and NS5B regions, and a good concordance was obtained at genotype level using both regions except for two samples where putative 1-4 recombinants/multiple infections were detected. Therefore, HCV genotyping based on at least two genomic regions could help to identify putative recombinants and improve therapeutic management of HCV infection.


Asunto(s)
Técnicas de Genotipaje , Hepacivirus/genética , Hepatitis C/virología , Proteínas del Núcleo Viral/genética , Proteínas no Estructurales Virales/genética , Anciano , Camerún , Femenino , Genotipo , Humanos , Masculino , Persona de Mediana Edad , Filogenia , Análisis de Secuencia de ADN , Carga Viral
4.
BMC Res Notes ; 12(1): 417, 2019 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-31307546

RESUMEN

OBJECTIVE: The aim of this study was to update the data on the prevalence of anti-HDV antibodies in Cameroon. RESULTS: Antibodies against hepatitis Delta virus (Anti-HDV) were found in 16.48% (95% CI 11.46-18.77%) of 426 hepatitis B virus surface antigen positive patients in Cameroon. Remarkably, they were significantly higher among people over 40 years and those living in the East and South regions of Cameroon at 66.7%, 50%, and 40%, respectively. These results suggest that older age and living in areas in the dense forest may be risk factors for Hepatitis D infection.


Asunto(s)
Anticuerpos Antihepatitis/inmunología , Antígenos de Superficie de la Hepatitis B/inmunología , Hepatitis B/diagnóstico , Hepatitis D/diagnóstico , Virus de la Hepatitis Delta/inmunología , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Evolución Biológica , Camerún/epidemiología , Niño , Estudios Transversales , Femenino , Hepatitis B/epidemiología , Hepatitis B/virología , Hepatitis D/epidemiología , Hepatitis D/virología , Virus de la Hepatitis Delta/fisiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Adulto Joven
5.
BMC Res Notes ; 11(1): 352, 2018 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-29871688

RESUMEN

OBJECTIVE: This study was aimed at evaluating the performance of three CE-marked rapid diagnostic tests (RDTs): Multisure-HCV, First Response® and Toyo®; for screening anti- HCV antibody using plasma samples. RESULTS: Overall, 200 plasma samples were used. Sensibility and specificity of these RDTs range from 71 to 99 and 78 to 100% respectively. Multisure scored a sensitivity at 99% (95% CI 97-100%) and First Response reached a specificity at 90% (95% CI 85-94.9%). Further studies should be conducted to establish an algorithm using these RTDs for the detection of HCV infection in Cameroon.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Anticuerpos contra la Hepatitis C/sangre , Hepatitis C/sangre , Tamizaje Masivo/métodos , Camerún , Hepatitis C/diagnóstico , Humanos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
6.
AIDS Res Hum Retroviruses ; 34(7): 621-625, 2018 07.
Artículo en Inglés | MEDLINE | ID: mdl-29575910

RESUMEN

HIV-1 group N (HIV-1/N) remains rare and mainly restricted to Cameroon. In this study, we report a new HIV-1/N infected case identified during routine HIV screening activities in Yaounde. The genetic characterization of the near full-length genome of this virus strain revealed that it is genetically distinct to all HIV-1/N described to date. However, the Vpu protein responsible for tetherin antagonism displayed the same amino acid substitutions (E15A, V19A, I25L, and V26L) as other HIV-1/N from Cameroon.


Asunto(s)
Genotipo , Infecciones por VIH/virología , VIH-1/clasificación , VIH-1/aislamiento & purificación , Adulto , Camerún , Femenino , VIH-1/genética , Humanos , Secuenciación Completa del Genoma
7.
Virol J ; 14(1): 224, 2017 11 14.
Artículo en Inglés | MEDLINE | ID: mdl-29137673

RESUMEN

BACKGROUND: HIV infection in Cameroon is characterized by a great viral diversity with all HIV-1 groups (M, N, O, and P) and HIV-2 in circulation. HIV group determination is very important if tailored viral load analysis and treatments are to be applied. In our laboratory, HIV viral load is carried out using two platforms; Biocentric and Abbott depending on the HIV group identified. Biocentric which quantifies HIV-1 group M is a cheap and open system useful in resource limited settings. The objective of this study was to compare the viral load analyses of serologically group-indeterminate HIV samples using the two platforms with the view of reducing cost. METHODS: Consecutive samples received between March and May 2014, and between August and September 2014 in our laboratory for HIV viral load analysis were included. All these samples were analyzed for their HIV groups using an in-house ELISA serotyping test. All HIV-1 group M samples were quantified using the Biocentric test while all other known atypical samples (HIV-1 groups N, O and P) were analyzed using the Abbott technique. HIV group-indeterminate samples (by serotyping) were quantified with both techniques. RESULTS: Among the 6355 plasma samples received, HIV-1 group M was identified in 6026 (94.82%) cases; HIV-1 group O, in 20 (0.31%); HIV-1 group M + O, in 3 (0.05%) and HIV-2, in 3 (0.05%) case. HIV-group indeterminate samples represented about 4.76% (303/6355) and only 231 of them were available for analysis by Abbott Real-Time HIV-1 and Generic HIV Viral Load techniques. Results showed that 188 (81.39%) samples had undetectable viral load in both techniques. All the detectable samples showed high viral load, with a mean of 4.5 log copies/ml (range 2.1-6.5) for Abbott Real-Time and 4.5 log copies/ml (range 2-6.4) for Generic HIV Viral Load. The mean viral load difference between the two techniques was 0.03 log10 copies/ml and a good correlation was obtained (r 2 = 0.89; P < 0.001). CONCLUSION: Our results suggest that cheaper and open techniques such as Biocentric could be useful alternatives for HIV viral load follow-up quantification in resource limited settings like Cameroon; even with its high viral diversity.


Asunto(s)
Variación Genética , Infecciones por VIH/virología , VIH-1/clasificación , VIH-2/clasificación , ARN Viral/sangre , Carga Viral/economía , Carga Viral/métodos , Camerún , Infecciones por VIH/sangre , VIH-1/genética , VIH-2/genética , Humanos , ARN Viral/genética , Juego de Reactivos para Diagnóstico/economía , Sensibilidad y Especificidad , Pruebas Serológicas
8.
Curr HIV Res ; 15(4): 297-305, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28745207

RESUMEN

BACKGROUND: First line antiretroviral therapy in a resource-limited setting consists of nucleotide and non-nucleotide reverse transcriptase inhibitors. Protease inhibitors are the hub of second line therapy. The decision to change antiretroviral therapy for a patient is frequently presumptive because of the lack of genotypic resistance tests in routine follow-up. We describe here the resistance profiles observed in patients with varying terms of antiretroviral therapy in Cameroon after implementation of HIV genotypic resistance testing in routine practice. METHODS: HIV genotypic resistance testing was carried out on consecutive samples received between August 2013 and November 2015. Protease (Prot) and reverse transcriptase (Rt) genes of the HIV genome were amplified, sequenced and analyzed for drug resistance mutations following the algorithm set up by the French National Agency for research on HIV/AIDS and viral hepatitis. RESULTS: Specimens from a total of 167 patients infected with non-B HIV subtypes were received during the study period. Overall 61.7% patients had viral loads of more than 3log copies/ml, suggesting treatment failure. Among the 72 patients on first line, 56 (77.8%) were resistant to Lamivudine, 57 (79.1%) to Efavirenz and 58 (80.6%) to Nevirapine. Overall, more patients (75.0%) on first line antiretroviral therapy harbored multi-drug resistance compared to their counterparts on second line (25.8%). CONCLUSION: This study revealed that a group of patients with antiretroviral therapy failure harbored multi-drug resistance mutations related to the majority of drugs in the first line regimen. Therefore, HIV resistance testing could be a useful tool to improve HIV care in resource limited settings like Cameroon where treatment options are limited.


Asunto(s)
Fármacos Anti-VIH/uso terapéutico , Farmacorresistencia Viral , Técnicas de Genotipaje/métodos , Infecciones por VIH/tratamiento farmacológico , VIH/efectos de los fármacos , Pruebas de Sensibilidad Microbiana/métodos , Adolescente , Adulto , Camerún , Femenino , Proteínas del Virus de la Inmunodeficiencia Humana/genética , Humanos , Masculino , Persona de Mediana Edad , Mutación Missense , Análisis de Secuencia de ADN , Insuficiencia del Tratamiento , Adulto Joven
9.
J Virol Methods ; 243: 158-163, 2017 05.
Artículo en Inglés | MEDLINE | ID: mdl-28219762

RESUMEN

According to the WHO/UNAIDS recommendations, an acceptable HIV rapid diagnostic tests (RDTs) has to perform a sensitivity≥99% and a specificity≥98%. Given the constant release of new RDTs for HIV testing in the market and the high HIV genetic diversity in Cameroon, it is interesting to monitor their performances in that setting. A total of 240 HIV positive (including 219 HIV-1 M, 15 HIV-1 O, 1 HIV-1 N, 1 HIV-1 M/O recombinant and 4 HIV-2) and 240 HIV negative plasma samples were used to evaluate twelve routinely used RDTs in Cameroon. A reference algorithm combining Enzyme Immunoassays and nucleic acid testing was used as gold standard. The sensitivity, specificity, positive predictive value, and negative predictive value of the twelve RDTs evaluated varied between 93.7 and 100%; 95.8 and 100%; 96.0 and 100%, and 94.1 and 100%, respectively. Five out of the twelve RDTs could not detect some HIV-1 O variants, one of them failed to detect an HIV-2 variant while all them efficiently detected HIV-1 N and HIV M/O recombinant. Our findings underscore the need to monitor the performances of RDTs to be used for HIV testing in Cameroon using locally obtained well-characterized samples panels.


Asunto(s)
Pruebas Diagnósticas de Rutina/métodos , Infecciones por VIH/diagnóstico , Camerún , Humanos , Tamizaje Masivo/métodos , Plasma/virología , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Factores de Tiempo
10.
AIDS ; 30(1): 1-8, 2016 Jan 02.
Artículo en Inglés | MEDLINE | ID: mdl-26731750

RESUMEN

OBJECTIVE: Despite the genetic divergence between HIV-1 groups M and O, HIV-1  M/O intergroup recombinants were reported. Actually, there is no data on the transmissibility of such recombinant forms. During a surveillance of HIV genetic diversity in Cameroon, we investigated the possible direct transmission of an HIV-1  M/O recombinant virus in an HIV-infected couple. METHODS: Consecutive samples obtained from the couple were analysed for detection of dual HIV-1 groups M and O infections, and HIV-1  M/O recombinant forms. Analyses were performed using a serological and molecular algorithm based on HIV serotyping and group-specific PCRs targeting the polymerase and envelope genes. Pattern characterization of the strains found in both patients was based on complete genome sequencing. Phylogenetic and similarity profile analyses were performed to investigate the genetic relationship between viruses from both spouses and the previously described recombinant forms. RESULTS: The sero-molecular algorithm data showed a group O serotype confirmed by molecular analysis in the envelope regions, whereas molecular tests identified HIV-1 group M in the polymerase. Phylogenetic analyses and similarity profiles of the full-length genome sequences showed that both spouses were infected with a unique recombinant virus having two recombination breakpoints in the vpr gene and LTR region. No phylogenetic link was found with the previous M/O recombinants. CONCLUSION: We provide, for the first time, molecular evidence of direct transmission of an HIV-1  M/O recombinant, highlighting the potential spread of these divergent viruses. The importance of HIV-1 recombination on genetic evolution and public health when implying divergent strains as group O has to be carefully considered.


Asunto(s)
Genotipo , Infecciones por VIH/transmisión , Infecciones por VIH/virología , VIH-1/clasificación , VIH-1/genética , Serogrupo , Adulto , Camerún , Femenino , Genoma Viral , Técnicas de Genotipaje , VIH-1/aislamiento & purificación , Humanos , Masculino , Filogenia , Reacción en Cadena de la Polimerasa , Recombinación Genética , Análisis de Secuencia de ADN , Serotipificación , Esposos , Productos del Gen env del Virus de la Inmunodeficiencia Humana/genética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...