Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Radiother Oncol ; 191: 110061, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38122850

RESUMEN

PURPOSE: Accurate and comprehensive segmentation of cardiac substructures is crucial for minimizing the risk of radiation-induced heart disease in lung cancer radiotherapy. We sought to develop and validate deep learning-based auto-segmentation models for cardiac substructures. MATERIALS AND METHODS: Nineteen cardiac substructures (whole heart, 4 heart chambers, 6 great vessels, 4 valves, and 4 coronary arteries) in 100 patients treated for non-small cell lung cancer were manually delineated by two radiation oncologists. The valves and coronary arteries were delineated as planning risk volumes. An nnU-Net auto-segmentation model was trained, validated, and tested on this dataset with a split ratio of 75:5:20. The auto-segmented contours were evaluated by comparing them with manually drawn contours in terms of Dice similarity coefficient (DSC) and dose metrics extracted from clinical plans. An independent dataset of 42 patients was used for subjective evaluation of the auto-segmentation model by 4 physicians. RESULTS: The average DSCs were 0.95 (+/- 0.01) for the whole heart, 0.91 (+/- 0.02) for 4 chambers, 0.86 (+/- 0.09) for 6 great vessels, 0.81 (+/- 0.09) for 4 valves, and 0.60 (+/- 0.14) for 4 coronary arteries. The average absolute errors in mean/max doses to all substructures were 1.04 (+/- 1.99) Gy and 2.20 (+/- 4.37) Gy. The subjective evaluation revealed that 94% of the auto-segmented contours were clinically acceptable. CONCLUSION: We demonstrated the effectiveness of our nnU-Net model for delineating cardiac substructures, including coronary arteries. Our results indicate that this model has promise for studies regarding radiation dose to cardiac substructures.


Asunto(s)
Carcinoma de Pulmón de Células no Pequeñas , Aprendizaje Profundo , Neoplasias Pulmonares , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/radioterapia , Carcinoma de Pulmón de Células no Pequeñas/diagnóstico por imagen , Carcinoma de Pulmón de Células no Pequeñas/radioterapia , Planificación de la Radioterapia Asistida por Computador/métodos , Corazón/diagnóstico por imagen , Órganos en Riesgo
2.
Diagnostics (Basel) ; 13(4)2023 Feb 10.
Artículo en Inglés | MEDLINE | ID: mdl-36832155

RESUMEN

Developers and users of artificial-intelligence-based tools for automatic contouring and treatment planning in radiotherapy are expected to assess clinical acceptability of these tools. However, what is 'clinical acceptability'? Quantitative and qualitative approaches have been used to assess this ill-defined concept, all of which have advantages and disadvantages or limitations. The approach chosen may depend on the goal of the study as well as on available resources. In this paper, we discuss various aspects of 'clinical acceptability' and how they can move us toward a standard for defining clinical acceptability of new autocontouring and planning tools.

3.
Sci Rep ; 12(1): 19093, 2022 11 09.
Artículo en Inglés | MEDLINE | ID: mdl-36351987

RESUMEN

Manually delineating upper abdominal organs at risk (OARs) is a time-consuming task. To develop a deep-learning-based tool for accurate and robust auto-segmentation of these OARs, forty pancreatic cancer patients with contrast-enhanced breath-hold computed tomographic (CT) images were selected. We trained a three-dimensional (3D) U-Net ensemble that automatically segments all organ contours concurrently with the self-configuring nnU-Net framework. Our tool's performance was assessed on a held-out test set of 30 patients quantitatively. Five radiation oncologists from three different institutions assessed the performance of the tool using a 5-point Likert scale on an additional 75 randomly selected test patients. The mean (± std. dev.) Dice similarity coefficient values between the automatic segmentation and the ground truth on contrast-enhanced CT images were 0.80 ± 0.08, 0.89 ± 0.05, 0.90 ± 0.06, 0.92 ± 0.03, 0.96 ± 0.01, 0.97 ± 0.01, 0.96 ± 0.01, and 0.96 ± 0.01 for the duodenum, small bowel, large bowel, stomach, liver, spleen, right kidney, and left kidney, respectively. 89.3% (contrast-enhanced) and 85.3% (non-contrast-enhanced) of duodenum contours were scored as a 3 or above, which required only minor edits. More than 90% of the other organs' contours were scored as a 3 or above. Our tool achieved a high level of clinical acceptability with a small training dataset and provides accurate contours for treatment planning.


Asunto(s)
Órganos en Riesgo , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/métodos , Abdomen/diagnóstico por imagen , Hígado , Planificación de Atención al Paciente , Procesamiento de Imagen Asistido por Computador/métodos
4.
PLoS One ; 14(9): e0222509, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31536526

RESUMEN

Radiomics studies require many patients in order to power them, thus patients are often combined from different institutions and using different imaging protocols. Various studies have shown that imaging protocols affect radiomics feature values. We examined whether using data from cohorts with controlled imaging protocols improved patient outcome models. We retrospectively reviewed 726 CT and 686 PET images from head and neck cancer patients, who were divided into training or independent testing cohorts. For each patient, radiomics features with different preprocessing were calculated and two clinical variables-HPV status and tumor volume-were also included. A Cox proportional hazards model was built on the training data by using bootstrapped Lasso regression to predict overall survival. The effect of controlled imaging protocols on model performance was evaluated by subsetting the original training and independent testing cohorts to include only patients whose images were obtained using the same imaging protocol and vendor. Tumor volume, HPV status, and two radiomics covariates were selected for the CT model, resulting in an AUC of 0.72. However, volume alone produced a higher AUC, whereas adding radiomics features reduced the AUC. HPV status and one radiomics feature were selected as covariates for the PET model, resulting in an AUC of 0.59, but neither covariate was significantly associated with survival. Limiting the training and independent testing to patients with the same imaging protocol reduced the AUC for CT patients to 0.55, and no covariates were selected for PET patients. Radiomics features were not consistently associated with survival in CT or PET images of head and neck patients, even within patients with the same imaging protocol.


Asunto(s)
Neoplasias de Cabeza y Cuello/mortalidad , Neoplasias de Cabeza y Cuello/patología , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tomografía de Emisión de Positrones/métodos , Modelos de Riesgos Proporcionales , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven
5.
Radiat Res ; 191(6): 497-506, 2019 06.
Artículo en Inglés | MEDLINE | ID: mdl-30925135

RESUMEN

Reduced weight bearing, and to a lesser extent radiation, during spaceflight have been shown as potential hazards to astronaut joint health. These hazards combined effect to the knee and hip joints are not well defined, particularly with low-dose exposure to radiation. In this study, we examined the individual and combined effects of varying low-dose radiation (≤1 Gy) and reduced weight bearing on the cartilage of the knee and hip joints. C57BL/6J mice (n = 80) were either tail suspended via hindlimb unloading (HLU) or remained full-weight bearing (ground). On day 6, each group was divided and irradiated with 0 Gy (sham), 0.1 Gy, 0.5 Gy or 1.0 Gy (n = 10/group), yielding eight groups: ground-sham; ground-0.1 Gy; ground-0.5 Gy; ground-1.0 Gy; HLU-sham; HLU-0.1 Gy; HLU-0.5 Gy; and HLU-1.0 Gy. On day 30, the hindlimbs, hip cartilage and serum were collected from the mice. Significant differences were identified statistically between treatment groups and the ground-sham control group, but no significant differences were observed between HLU and/or radiation groups. Contrast-enhanced micro-computed tomography (microCECT) demonstrated decrease in volume and thickness at the weight-bearing femoral-tibial cartilage-cartilage contact point in all treatment groups compared to ground-sham. Lower collagen was observed in all groups compared to ground-sham. Circulating serum cartilage oligomeric matrix protein (sCOMP), a biomarker for ongoing cartilage degradation, was increased in all of the irradiated groups compared to ground-sham, regardless of unloading. Mass spectrometry of the cartilage lining the femoral head and subsequent Ingenuity Pathway Analysis (IPA) identified a decrease in cartilage compositional proteins indicative of osteoarthritis. Our findings demonstrate that both individually and combined, HLU and exposure to spaceflight relevant radiation doses lead to cartilage degradation of the knee and hip with expression of an arthritic phenotype. Moreover, early administration of low-dose irradiation (0.1, 0.5 or 1.0 Gy) causes an active catabolic response in cartilage 24 days postirradiation. Further research is warranted with a focus on the prevention of cartilage degradation from long-term periods of reduced weight bearing and spaceflight-relevant low doses and qualities of radiation.


Asunto(s)
Cartílago Articular/patología , Cartílago Articular/efectos de la radiación , Suspensión Trasera/efectos adversos , Articulación de la Cadera/efectos de la radiación , Articulación de la Rodilla/efectos de la radiación , Vuelo Espacial , Animales , Cartílago Articular/diagnóstico por imagen , Relación Dosis-Respuesta en la Radiación , Femenino , Ratones , Ratones Endogámicos C57BL , Factores de Tiempo , Microtomografía por Rayos X
6.
Artículo en Inglés | MEDLINE | ID: mdl-32095575

RESUMEN

The purpose of this study was to determine if medical linear accelerators (linac) produced by the same manufacturer exhibit operational consistency within their subsystems and components. Two linacs that were commissioned together and installed at the same facility were monitored. Each machine delivered a daily robust quality assurance (QA) irradiation. Linacs and their components operate consistently, but have different operational parameter levels even when produced by the same manufacturer and commissioned in series. These findings have implications on the feasibility of true clinical beam matching.

7.
Comput Biol Med ; 67: 41-8, 2015 Dec 01.
Artículo en Inglés | MEDLINE | ID: mdl-26496701

RESUMEN

Thoracic anthropometry variations with age and sex have been reported and likely relate to thoracic injury risk and outcome. The objective of this study was to collect a large volume of homologous semilandmark data from the thoracic skeleton for the purpose of quantifying thoracic morphology variations for males and females of ages 0-100 years. A semi-automated image segmentation and registration algorithm was applied to collect homologous thoracic skeleton semilandmarks from 343 normal computed tomography (CT) scans. Rigid, affine, and symmetric diffeomorphic transformations were used to register semilandmarks from an atlas to homologous locations in the subject-specific coordinate system. Homologous semilandmarks were successfully collected from 92% (7077) of the ribs and 100% (187) of the sternums included in the study. Between 2700 and 11,000 semilandmarks were collected from each rib and sternum and over 55 million total semilandmarks were collected from all subjects. The extensive landmark data collected more fully characterizes thoracic skeleton morphology across ages and sexes. Characterization of thoracic morphology with age and sex may help explain variations in thoracic injury risk and has important implications for vulnerable populations such as pediatrics and the elderly.


Asunto(s)
Determinación de la Edad por el Esqueleto/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Costillas/diagnóstico por imagen , Determinación del Sexo por el Esqueleto/métodos , Esternón/diagnóstico por imagen , Técnica de Sustracción , Adolescente , Adulto , Anciano , Anciano de 80 o más Años , Puntos Anatómicos de Referencia , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Radiografía Torácica/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Caracteres Sexuales , Adulto Joven
8.
J Morphol ; 275(11): 1284-99, 2014 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-24935890

RESUMEN

Age and sex-related variations in sternum morphology may affect the thoracic injury tolerance. Male and female sternum size and shape variation was characterized for ages 0-100 from landmarks collected from 330 computed tomography scans. Homologous landmarks were analyzed using Procrustes superimposition to produce age and sex-specific functions of 3D-sternum morphology representing the combined size and shape variation and the isolated shape variation. Significant changes in the combined size and shape variation and isolated shape variation of the sternum were found to occur with age in both sexes. Sternal size increased from birth through age 30 and retained a similar size for ages 30-100. The manubrium expanded laterally from birth through age 30, becoming wider in relation to the sternal body. In infancy, the manubrium was 1.1-1.2 times the width of the sternal body and this width ratio increased to 1.6-1.8 for adults. The manubrium transformed from a circular shape in infancy to an oval shape in early childhood. The distal sternal body became wider in relation to the proximal sternal body from birth through age 30 and retained this characteristic throughout adulthood. The most dramatic changes in sternum morphology occur in childhood and young adulthood when the sternum is undergoing ossification. The lesser degree of ossification in the pediatric sternum may be partly responsible for the prevalence of thoracic organ injuries as opposed to thoracic skeletal injuries in pediatrics. Sternum fractures make up a larger portion of thoracic injury patterns in adults with fully ossified sternums. The lack of substantial size or shape changes in the sternum from age 30-100 suggests that the increased incidence of sternal fracture seen in the elderly may be due to cortical thickness or bone mineral density changes in the sternum as opposed to morphological changes.


Asunto(s)
Esternón/anatomía & histología , Esternón/crecimiento & desarrollo , Adolescente , Adulto , Factores de Edad , Anciano , Anciano de 80 o más Años , Antropometría , Densidad Ósea , Niño , Preescolar , Diseño Asistido por Computadora , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Persona de Mediana Edad , Osteogénesis , Intensificación de Imagen Radiográfica , Valores de Referencia , Análisis de Regresión , Reproducibilidad de los Resultados , Factores Sexuales , Esternón/diagnóstico por imagen , Tomografía Computarizada por Rayos X , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...