1.
J Appl Physiol (1985) ; 136(2): 440-449, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38205548

RESUMEN

The health consequences associated with using electronic cigarettes (ECs) are of great public interest because of their potential role in smoking cessation. In 110 participants, including 41 nonusers, 34 people who exclusively use ECs (EC group), and 35 people who smoke tobacco cigarettes (TCs) including 12 dual users (collectively called the TC-D group), the heart rate (HR), blood pressure (BP), and heart rate variability (HRV) were compared at baseline. People in the EC or the TC-D groups were also compared after using a 4th generation EC with or without nicotine, a TC with or without nicotine (TC-D group only), and a straw-control. Baseline HR, BP, and HRV parameters were not different among the EC, the TC-D, and nonuser groups. In people who exclusively use ECs, acute nicotine-EC use increased HR and BP, and produced changes in HRV patterns suggestive of increased cardiac sympathetic influence. In people in the TC-D group, BP increased similarly after acutely smoking a nicotine-TC or a nicotine-EC. However, the increase in HR was significantly greater after smoking a TC compared with the nicotine-EC despite similar acute increases in plasma nicotine. Overall, all exposures containing nicotine significantly increased HR and BP in both cohorts when compared with non-nicotine exposures. Since acute EC use 1) produces an abnormal HRV pattern associated with increased cardiac sympathetic tone in people who chronically use ECs, and 2) similar hemodynamic increases compared with acute TC smoking in people who chronically smoke TCs including dual users, the role of ECs as part of a harm reduction strategy is questioned.NEW & NOTEWORTHY We found that nicotine, not the non-nicotine constituents in tobacco cigarette (TC) or electronic cigarette (EC) emissions, may be the instigator of the acute, potentially adverse, changes in hemodynamics and heart rate variability (HRV) that were recorded several minutes after tobacco product use. Furthermore, acute EC use produced an abnormal HRV pattern associated with increased cardiac risk in people who chronically smoke ECs and produced similar hemodynamic increases compared with acute TC use in people who chronically smoke TCs, including people who are dual users.


Asunto(s)
Sistema Cardiovascular , Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Humanos , Nicotina/efectos adversos , Reducción del Daño
2.
Am J Physiol Heart Circ Physiol ; 324(6): H821-H832, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37057991

RESUMEN

Electronic cigarettes are often used for smoking cessation as a harm reduction strategy, but studies comparing risks of electronic cigarettes (ECs) and tobacco cigarettes (TCs) are scarce. Ventricular repolarization in people who smoke TCs is abnormal. Baseline repolarization was compared among nonusers (people who do not use TCs or ECs) and people who use ECs or TCs. The acute effects of ECs and TCs on metrics of ventricular repolarization were then compared in people who chronically smoke. A total of 110 participants (59 female), including 35 people (21 females) in the TC cohort, 34 people (17 females) in the EC cohort, and 41 people (21 females) in the nonuser cohort, were included. None of the primary outcomes, Tpeak-end (Tp-e), Tp-e/QT, and Tp-e/QTc, were different among the three cohorts at supine baseline, even when adjusted for sex. When compared with the control exposure standing after acutely using the EC but not the TC, significantly prolonged all three primary indices of ventricular repolarization in people who smoke TCs. The major new finding in this study is that in people who smoke TCs, using an EC compared with a TC significantly prolongs ventricular repolarization. Furthermore, in our subgroup analysis by sex, this adverse effect on repolarization is found only in male, not female, smokers. In summary, chronic TC smoking is the most prevalent, modifiable risk factor for cardiovascular death, including sudden cardiac death. If used for smoking cessation, ECs should only be used in the short term since they too carry their own risks; this risk appears to be greatest in males compared with females who smoke.NEW & NOTEWORTHY The major new finding in this study is that in people who smoke tobacco cigarettes, using an electronic cigarette but not a tobacco cigarette acutely and significantly prolongs several metrics of ventricular repolarization, including Tpeak-Tend, Tpeak-Tend/QT, and Tpeak-Tend/QTc. Furthermore, in our subgroup analysis by sex, this adverse effect on repolarization is found only in male, not female, smokers.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Femenino , Humanos , Masculino , Nicotina/efectos adversos , Reducción del Daño , Fumar/efectos adversos
3.
Front Rehabil Sci ; 3: 887740, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36189005

RESUMEN

Background: Virtual exercise has become more common as emerging and converging technologies make active virtual reality games (AVRGs) a viable mode of exercise for health and fitness. Our lab has previously shown that AVRGs can elicit moderate to vigorous exercise intensities that meet recommended health benefit guidelines. Dissociative attentional focuses during AVRG gameplay have the potential to widen the gap between participants' perception of exertion and actual exertion. Objective: The aim of this study was to determine actual exertion (AEx) vs. perceived exertion (PEx) levels during AVRGs by measuring heart rate (HR) and ratings of perceived exertion (RPE) in two different settings. Materials and methods: HR and RPE were collected on participants (N = 32; age 22.6 ± 2.6) during 10 min of gameplay in LabS and GymS using the HTC VIVE with the following games played: Fruit Ninja VR (FNVR), Beat Saber (BS), and Holopoint (HP). Results: Participants exhibited significantly higher levels of AEx compared to reported PEx for all three AVRGs (Intensity): FNVR [AEx = 11.6 ± 1.8 (Light), PEx = 9.0 ± 2.0 (Very Light)], BS [AEx = 11.3 ± 1.7 (Light), PEx = 10.3 ± 2.1 (Very Light)], HP [AEx = 13.1 ± 2.3 (Somewhat Hard), PEx = 12.3 ± 2.4 (Light-Somewhat Hard)]. Additionally, participants playing in the GymS experienced significantly higher levels of AEx [12.4 ± 2.3 (Light-Somewhat Hard)] and PEx [10.8 ± 2.5 (Very Light-Light)] compared to the LabS [AEx = 11.6 ± 1.8 (Light), PEx = 10.3 ± 2.6 (Very Light-Light)]. Conclusion: Perceptions of exertion may be lower than actual exertion during AVRG gameplay, and exertion levels can be influenced by the setting in which AVRGs are played. This may inform VR developers and health clinicians who aim to incorporate exercise/fitness regimens into upcoming 'virtual worlds' currently being developed at large scales (i.e., the "metaverse").

4.
Ann Noninvasive Electrocardiol ; 27(4): e12958, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35712805

RESUMEN

BACKGROUND: The Tpeak-end(Tp-e) has not been compared in all 12 ECG leads in healthy adults to determine if the Tp-e varies across leads. If there is variation, it remains uncertain, which lead(s) are preferred for recording in order to capture the maximal Tp-e value. OBJECTIVE: The purpose of the current study was to determine the optimal leads, if any, to capture the maximal Tp-e interval in healthy young adults. METHODS: In 88 healthy adults (ages 21-38 years), including derivation (n = 21), validation (n = 20), and smoker/vaper (n = 47) cohorts, the Tp-e was measured using commercial computer software (LabChart Pro 8 with ECG module, ADInstruments) in all 12 leads at rest and following a provocative maneuver, abrupt standing. Tp-e was compared to determine which lead(s) most frequently captured the maximal Tp-e interval. RESULTS: In the rest and abrupt standing positions, the Tp-e was not uniform among the 12 leads; the maximal Tp-e was most frequently captured in the precordial leads. At rest, grouping leads V2-V4 resulted in detection of the maximum Tp-e in 85.7% of participants (CI 70.7, 99.9%) versus all other leads (p < .001). Upon abrupt standing, grouping leads V2-V6 together, resulted in detection of the maximum Tp-e 85.0% of participants (CI 69.4, 99.9% versus all other leads; p < .001). These findings were confirmed in the validation cohort, and extended to the smoking/vaping cohort. CONCLUSION: If only a subset of ECG leads will be recorded or analyzed for the Tp-e interval, selection of the precordial leads is preferred since these leads are most likely to capture the maximal Tp-e value.


Asunto(s)
Electrocardiografía , Adulto , Estudios de Cohortes , Electrocardiografía/métodos , Humanos , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA