Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
J Korean Soc Radiol ; 85(2): 345-362, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38617869

RESUMEN

MRI plays an important role in abdominal imaging because of its ability to detect and characterize focal lesions. However, MRI examinations have several challenges, such as comparatively long scan times and motion management through breath-holding maneuvers. Techniques for reducing scan time with acceptable image quality, such as parallel imaging, compressed sensing, and cutting-edge deep learning techniques, have been developed to enable problem-solving strategies. Additionally, free-breathing techniques for dynamic contrast-enhanced imaging, such as extra-dimensional-volumetric interpolated breath-hold examination, golden-angle radial sparse parallel, and liver acceleration volume acquisition Star, can help patients with severe dyspnea or those under sedation to undergo abdominal MRI. We aimed to present various advanced abdominal MRI techniques for reducing the scan time while maintaining image quality and free-breathing techniques for dynamic imaging and illustrate cases using the techniques mentioned above. A review of these advanced techniques can assist in the appropriate interpretation of sequences.

2.
Eur Radiol ; 2024 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-38492004

RESUMEN

OBJECTIVE: To investigate whether a deep learning (DL) controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA)-volumetric interpolated breath-hold examination (VIBE) technique can improve image quality, lesion conspicuity, and lesion detection compared to a standard CAIPIRINHA-VIBE technique in gadoxetic acid-enhanced liver MRI. METHODS: This retrospective single-center study included 168 patients who underwent gadoxetic acid-enhanced liver MRI at 3 T using both standard CAIPIRINHA-VIBE and DL CAIPIRINHA-VIBE techniques on pre-contrast and hepatobiliary phase (HBP) images. Additionally, high-resolution (HR) DL CAIPIRINHA-VIBE was obtained with 1-mm slice thickness on the HBP. Three abdominal radiologists independently assessed the image quality and lesion conspicuity of pre-contrast and HBP images. Statistical analyses involved the Wilcoxon signed-rank test for image quality assessment and the generalized estimation equation for lesion conspicuity and detection evaluation. RESULTS: DL and HR-DL CAIPIRINHA-VIBE demonstrated significantly improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE (p < 0.001), with a shorter acquisition time (DL vs standard, 11 s vs 17 s). However, the former presented a more synthetic appearance (both p < 0.05). HR-DL CAIPIRINHA-VIBE showed superior lesion conspicuity to standard and DL CAIPIRINHA-VIBE on HBP images (p < 0.001). Moreover, HR-DL CAIPIRINHA-VIBE exhibited a significantly higher detection rate of small (< 2 cm) solid focal liver lesions (FLLs) on HBP images compared to standard CAIPIRINHA-VIBE (92.5% vs 87.4%; odds ratio = 1.83; p = 0.036). CONCLUSION: DL and HR-DL CAIPIRINHA-VIBE achieved superior image quality compared to standard CAIPIRINHA-VIBE. Additionally, HR-DL CAIPIRINHA-VIBE improved the lesion conspicuity and detection of small solid FLLs. DL and HR-DL CAIPIRINHA-VIBE hold the potential clinical utility for gadoxetic acid-enhanced liver MRI. CLINICAL RELEVANCE STATEMENT: DL and HR-DL CAIPIRINHA-VIBE hold promise as potential alternatives to standard CAIPIRINHA-VIBE in routine clinical liver MRI, improving the image quality and lesion conspicuity, enhancing the detection of small (< 2 cm) solid focal liver lesions, and reducing the acquisition time. KEY POINTS: • DL and HR-DL CAIPIRINHA-VIBE demonstrated improved overall image quality and reduced artifacts on pre-contrast and HBP images compared to standard CAIPIRINHA-VIBE, in addition to a shorter acquisition time. • DL and HR-DL CAIPIRINHA-VIBE yielded a more synthetic appearance than standard CAIPIRINHA-VIBE. • HR-DL CAIPIRINHA-VIBE showed improved lesion conspicuity than standard CAIPIRINHA-VIBE on HBP images, with a higher detection of small (< 2 cm) solid focal liver lesions.

3.
Abdom Radiol (NY) ; 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38512517

RESUMEN

PURPOSE: To evaluated the impact of a deep learning (DL)-based image reconstruction on multi-arterial-phase magnetic resonance imaging (MA-MRI) for small hypervascular hepatic masses in patients who underwent gadoxetic acid-enhanced liver MRI. METHODS: We retrospectively enrolled 55 adult patients (aged ≥ 18 years) with small hepatic hypervascular mass (≤ 3 cm) between December 2022 and February 2023. All patients underwent MA-MRI, subsequently reconstructed with a DL-based application. Qualitative assessment with Linkert scale including motion artifact (MA), liver edge (LE), hepatic vessel clarity (HVC) and image quality (IQ) was performed. Quantitative image analysis including signal to noise ratio (SNR), contrast to noise ratio (CNR) and noise was performed. RESULTS: On both arterial phases (APs), all qualitative parameters were significantly improved after DL-based image reconstruction. (LE on 1st AP, 1.22 vs 1.61; LE on 2nd AP, 1.21 vs 1.65; HVC on 1st AP, 1.24 vs 1.39; HVC on 2nd AP, 1.24 vs 1.44; IQ on 1st AP, 1.17 vs 1.45; IQ on 2nd AP, 1.17 vs 1.47, all p values < 0.05). The SNR, CNR and noise were significantly improved after DL-based image reconstruction. (SNR on AP1, 279.08 vs 176.14; SNR on AP2, 334.34 vs 199.24; CNR on AP1, 106.09 vs 64.14; CNR on AP2, 129.66 vs 73.73; noise on AP1, 1.51 vs 2.33; noise on AP2, 1.45 vs 2.28, all p values < 0.05). CONCLUSIONS: Gadoxetic acid-enhanced MA-MRI with DL-based image reconstruction improved the qualitative and quantitative parameters. Despite the short acquisition time, high-quality MA-MRI is now achievable.

4.
Magn Reson Med Sci ; 23(2): 146-152, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-36740257

RESUMEN

PURPOSE: To evaluate the feasibility of breath-hold (BH) high-resolution (HR) T1-weighted gradient echo hepatobiliary phase (HBP) imaging using compressed sensing (CS) in gadoxetic acid-enhanced liver MRI in comparison with standard HBP imaging using parallel imaging (PI). METHODS: The study included 122 patients with liver tumors with hypointensity in the HBP who underwent both HR HBP imaging with CS and standard HBP imaging with PI. Two radiologists evaluated the liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, image noise, and overall image quality, as well as the lesion conspicuity on HR and standard HBP imaging and the contrast-enhanced (CE) MR cholangiography (MRC) image quality reconstructed from HBP images. As a quantitative analysis, the SNR of the liver and the liver to lesion signal intensity ratio (LLSIR) were also determined. RESULTS: The liver edge sharpness, hepatic vessel conspicuity, bile duct conspicuity, and overall image quality as well as the lesion conspicuity and the LLSIR on HR HBP imaging with CS were significantly higher than those on standard HBP imaging (all of P < 0.001). The image quality of CE-MRC reconstructed from HR HBP imaging with CS was also significantly higher than that from standard HBP imaging (P < 0.001). Conversely, the SNR of liver in standard HBP was significantly higher than that in HR HBP with CS (P < 0.001). CONCLUSION: BH HR HBP imaging with CS provided an improved overall image quality, lesion conspicuity, and CE-MRC visualization when compared with standard HBP imaging without extending the acquisition time.


Asunto(s)
Medios de Contraste , Imagenología Tridimensional , Humanos , Imagenología Tridimensional/métodos , Hígado/diagnóstico por imagen , Hígado/patología , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Aumento de la Imagen/métodos , Estudios Retrospectivos
5.
J Magn Reson Imaging ; 59(3): 1074-1082, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37209387

RESUMEN

BACKGROUND: Pancreatic stiffness and extracellular volume fraction (ECV) are potential imaging biomarkers for pancreatic fibrosis. Clinically relevant postoperative fistula (CR-POPF) is one of the most severe complications after pancreaticoduodenectomy. Which imaging biomarker performs better for predicting the risk of CR-POPF remains unknown. PURPOSE: To evaluate the diagnostic performance of ECV and tomoelastography-derived pancreatic stiffness for predicting the risk of CR-POPF in patients undergoing pancreaticoduodenectomy. STUDY TYPE: Prospective. POPULATION: Eighty patients who underwent multiparametric pancreatic MRI before pancreaticoduodenectomy, among whom 16 developed CR-POPF and 64 did not. FIELD STRENGTH/SEQUENCE: 3 T/tomoelastography and precontrast and postcontrast T1 mapping of the pancreas. ASSESSMENT: Pancreatic stiffness was measured on the tomographic c-map, and pancreatic ECV was calculated from precontrast and postcontrast T1 maps. Pancreatic stiffness and ECV were compared with histological fibrosis grading (F0-F3). The optimal cutoff values for predicting CR-POPF were determined, and the correlation between CR-POPF and imaging parameters was evaluated. STATISTICAL TESTS: The Spearman's rank correlation and multivariate linear regression analysis was conducted. The receiver operating characteristic curve analysis and logistic regression analysis was performed. A double-sided P < 0.05 indicated a statistically significant difference. RESULTS: Pancreatic stiffness and ECV both showed a significantly positive correlation with histological pancreatic fibrosis (r = 0.73 and 0.56, respectively). Patients with advanced pancreatic fibrosis had significantly higher pancreatic stiffness and ECV compared to those with no/mild fibrosis. Pancreatic stiffness and ECV were also correlated with each other (r = 0.58). Lower pancreatic stiffness (<1.38 m/sec), lower ECV (<0.28), nondilated main pancreatic duct (<3 mm) and pathological diagnosis other than pancreatic ductal adenocarcinoma were associated with higher risk of CR-POPF at univariate analysis, and pancreatic stiffness was independently associated with CR-POPF at multivariate analysis (odds ratio: 18.59, 95% confidence interval: 4.45, 77.69). DATA CONCLUSION: Pancreatic stiffness and ECV were associated with histological fibrosis grading, and pancreatic stiffness was an independent predictor for CR-POPF. LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 5.


Asunto(s)
Páncreas , Fístula Pancreática , Humanos , Fístula Pancreática/complicaciones , Fístula Pancreática/diagnóstico , Estudios Prospectivos , Factores de Riesgo , Páncreas/patología , Fibrosis , Complicaciones Posoperatorias/patología , Imagen por Resonancia Magnética/efectos adversos , Estudios Retrospectivos
6.
Eur Radiol ; 34(4): 2457-2467, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37776361

RESUMEN

OBJECTIVES: Diffusion-weighted imaging (DWI) with simultaneous multi-slice (SMS) acquisition and advanced processing can accelerate acquisition time and improve MR image quality. This study evaluated the image quality and apparent diffusion coefficient (ADC) measurements of free-breathing DWI acquired from patients with liver metastases using a prototype SMS-DWI acquisition (with/without an advanced processing option) and conventional DWI. METHODS: Four DWI schemes were compared in a pilot 5-patient cohort; three DWI schemes were further assessed in a 24-patient cohort. Two readers scored image quality of all b-value images and ADC maps across the three methods. ADC measurements were performed, for all three methods, in left and right liver parenchyma, spleen, and liver metastases. The Friedman non-parametric test (post-hoc Wilcoxon test with Bonferroni correction) was used to compare image quality scoring; t-test was used for ADC comparisons. RESULTS: SMS-DWI was faster (by 24%) than conventional DWI. Both readers scored the SMS-DWI with advanced processing as having the best image quality for highest b-value images (b750) and ADC maps; Cohen's kappa inter-reader agreement was 0.6 for b750 image and 0.56 for ADC maps. The prototype SMS-DWI sequence with advanced processing allowed a better visualization of the left lobe of the liver. ADC measured in liver parenchyma, spleen, and liver metastases using the SMS-DWI with advanced processing option showed lower values than those derived from the SMS-DWI method alone (t-test, p < 0.0001; p < 0.0001; p = 0.002). CONCLUSIONS: Free-breathing SMS-DWI with advanced processing was faster and demonstrated better image quality versus a conventional DWI protocol in liver patients. CLINICAL RELEVANCE STATEMENT: Free-breathing simultaneous multi-slice- diffusion-weighted imaging (DWI) with advanced processing was faster and demonstrated better image quality versus a conventional DWI protocol in liver patients. KEY POINTS: • Diffusion-weighted imaging (DWI) with simultaneous multi-slice (SMS) can accelerate acquisition time and improve image quality. • Apparent diffusion coefficients (ADC) measured in liver parenchyma, spleen, and liver metastases using the simultaneous multi-slice DWI with advanced processing were significantly lower than those derived from the simultaneous multi-slice DWI method alone. • Simultaneous multi-slice DWI sequence with inline advanced processing was faster and demonstrated better image quality in liver patients.


Asunto(s)
Neoplasias Hepáticas , Respiración , Humanos , Reproducibilidad de los Resultados , Neoplasias Hepáticas/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Imagen Eco-Planar/métodos
7.
Eur Radiol ; 34(4): 2233-2243, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37731096

RESUMEN

OBJECTIVE: We aimed to compare the image quality and focal lesion detection ability of hepatobiliary phase (HBP) images obtained using compressed sensing (CS) and controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) in patients with liver cirrhosis. MATERIALS AND METHODS: We retrospectively included 244 gadoxetic acid-enhanced liver MRI from 244 patients with cirrhosis obtained by two HBP images using CS and CAIPIRINHA from July 2020 to December 2020. The optimized resolution and scan time for CS-HBP and CAIPIRINHA-HBP were 0.9 × 0.9 × 1.5 mm3 and 15 s and 1.3 × 1.3 × 3 mm3 and 16 s, respectively. We compared the image quality between the two sets of images in 244 patients and focal lesion (n = 294) analyses for 112 patients. RESULTS: CS-HBP showed comparable overall image quality (3.7 ± 0.9 vs. 3.6 ± 0.8, p = 0.680), superior liver edge sharpness (3.9 ± 0.6 vs. 3.6 ± 0.5, p < 0.001), and fewer respiratory motion artifacts (4.0 ± 0.7 vs. 3.8 ± 0.5, p < 0.001), but higher non-respiratory artifacts (3.4 ± 0.7 vs. 3.6 ± 0.6, p < 0.001) and subjective image noise (3.5 ± 0.8 vs. 3.6 ± 0.7, p = 0.014) than CAIPIRINHA-HBP. CS-HBP showed a higher signal-to-noise ratio in the liver than CAIPIRINHA-HBP (20.9 ± 9.0 vs. 18.9 ± 7.1, p = 0.008). The pooled sensitivity, specificity, and AUC were 90.0%, 77.5%, and 0.84 for CS-HBP and 73.5%, 82.4%, and 0.78 for CAIPIRINHA-HBP, respectively. CONCLUSIONS: CS-HBP showed better focal lesion detection ability, comparable overall image quality, and fewer respiratory motion artifacts, but higher non-respiratory artifacts and noise compared to CAIPIRINHA-HBP. Thus, CS-HBP could be recommended for liver MRI in patients with cirrhosis to improve diagnostic performance. CLINICAL RELEVANCE STATEMENT: Thin-slice CS-HBP may be useful for detecting sub-centimeter hepatocellular carcinoma in cirrhotic patients with Child-Pugh classification A while maintaining comparable subjective image quality. KEY POINTS: • Compared with controlled aliasing in parallel imaging results in higher acceleration, compressed sensing hepatobiliary phase yielded thinner slices and shorter scan time at a higher accelerating factor. • Compressed sensing hepatobiliary phase showed comparable overall image quality, superior liver edge sharpness, and fewer respiratory motion artifacts, but higher non-respiratory artifacts and subjective image noise than controlled aliasing in parallel imaging results in higher acceleration-hepatobiliary phase. • Compressed sensing hepatobiliary phase can detect sub-centimeter hepatocellular carcinoma in cirrhotic patients with Child-Pugh classification A.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Medios de Contraste , Estudios Retrospectivos , Imagenología Tridimensional/métodos , Gadolinio DTPA , Imagen por Resonancia Magnética/métodos , Aceleración , Cirrosis Hepática/complicaciones , Cirrosis Hepática/diagnóstico por imagen , Neoplasias Hepáticas/complicaciones , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/patología , Artefactos , Aumento de la Imagen/métodos
9.
Eur Radiol ; 33(11): 8122-8131, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-37278853

RESUMEN

OBJECTIVE: To investigate the utility of ultrafast dynamic-contrast-enhanced (DCE) MRI in visualization and quantitative characterization of pregnancy-associated breast cancer (PABC) and its differentiation from background-parenchymal-enhancement (BPE) among lactating patients. MATERIALS AND METHODS: Twenty-nine lactating participants, including 10 PABC patients and 19 healthy controls, were scanned on 3-T MRI using a conventional DCE protocol interleaved with a golden-angle radial sparse parallel (GRASP) ultrafast sequence for the initial phase. The timing of the visualization of PABC lesions was compared to lactational BPE. Contrast-noise ratio (CNR) was compared between the ultrafast and conventional DCE sequences. The differences in each group's ultrafast-derived kinetic parameters including maximal slope (MS), time to enhancement (TTE), and area under the curve (AUC) were statistically examined using the Mann-Whitney test and receiver operator characteristic (ROC) curve analysis. RESULTS: On ultrafast MRI, breast cancer lesions enhanced earlier than BPE (p < 0.0001), enabling breast cancer visualization freed from lactation BPE. A higher CNR was found for ultrafast acquisitions vs. conventional DCE (p < 0.05). Significant differences in AUC, MS, and TTE values were found between the tumor and BPE (p < 0.05), with ROC-derived AUC of 0.86 ± 0.06, 0.82 ± 0.07, and 0.68 ± 0.08, respectively. The BPE grades of the lactating PABC patients were reduced as compared with the healthy lactating controls (p < 0.005). CONCLUSION: Ultrafast DCE MRI allows BPE-free visualization of lesions, improved tumor conspicuity, and kinetic quantification of breast cancer during lactation. Implementation of this method may assist in the utilization of breast MRI for lactating patients. CLINICAL RELEVANCE: The ultrafast sequence appears to be superior to conventional DCE MRI in the challenging evaluation of the lactating breast. Thus, supporting its possible utilization in the setting of high-risk screening during lactation and the diagnostic workup of PABC. KEY POINTS: • Differences in the enhancement slope of cancer relative to BPE allowed the optimal visualization of PABC lesions on mid-acquisitions of ultrafast DCE, in which the tumor enhanced prior to the background parenchyma. • The conspicuity of PABC lesions on top of the lactation-related BPE was increased using an ultrafast sequence as compared with conventional DCE MRI. • Ultrafast-derived maps provided further characterization and parametric contrast between PABC lesions and lactation-related BPE.


Asunto(s)
Neoplasias de la Mama , Lactancia , Femenino , Embarazo , Humanos , Neoplasias de la Mama/patología , Aumento de la Imagen/métodos , Medios de Contraste , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos
10.
Cancers (Basel) ; 15(12)2023 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-37370861

RESUMEN

We investigated the association of T1/T2 mapping values with programmed death-ligand 1 protein (PD-L1) expression in lung cancer and their potential in distinguishing between different histological subtypes of non-small cell lung cancers (NSCLCs). Thirty-five patients diagnosed with stage III NSCLC from April 2021 to December 2022 were included. Conventional MRI sequences were acquired with a 1.5 T system. Mean T1 and T2 mapping values were computed for six manually traced ROIs on different areas of the tumor. Data were analyzed through RStudio. Correlation between T1/T2 mapping values and PD-L1 expression was studied with a Wilcoxon-Mann-Whitney test. A Kruskal-Wallis test with a post-hoc Dunn test was used to study the correlation between T1/T2 mapping values and the histological subtypes: squamocellular carcinoma (SCC), adenocarcinoma (ADK), and poorly differentiated NSCLC (PD). There was no statistically significant correlation between T1/T2 mapping values and PD-L1 expression in NSCLC. We found statistically significant differences in T1 mapping values between ADK and SCC for the periphery ROI (p-value 0.004), the core ROI (p-value 0.01), and the whole tumor ROI (p-value 0.02). No differences were found concerning the PD NSCLCs.

11.
Ann Surg Oncol ; 30(9): 5577-5585, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37355522

RESUMEN

PURPOSE: This study investigated predictors of cervical cancer (CC) recurrence from native T1 mapping, conventional imaging, and clinicopathologic metrics. PATIENTS AND METHODS: In total, 144 patients with histopathologically confirmed CC (90 with and 54 without surgical treatment) were enrolled in this prospective study. Native T1 relaxation time, conventional imaging, and clinicopathologic characteristics were acquired. The association of quantitative and qualitative parameters with post-treatment tumor recurrence was assessed using univariate and multivariate Cox proportional hazard regression analyses. Independent risk factors were combined into a model and individual prognostic index equation for predicting recurrence risk. The receiver operating characteristic (ROC) curve determined the optimal cutoff point. RESULTS: In total, 12 of 90 (13.3%) surgically treated patients experienced tumor recurrence. Native T1 values (X1) [hazard ratio (HR) 1.008; 95% confidence interval (CI) 1.001-1.016], maximum tumor diameter (X2) (HR 1.065; 95% CI 1.020-1.113), and parametrial invasion (X3) (HR 3.930; 95% CI 1.013-15.251) were independent tumor recurrence risk factors. The individual prognostic index (PI) of the established recurrence risk model was PI = 0.008X1 + 0.063X2 + 1.369X3. The area under the ROC curve (AUC) of the Cox regression model was 0.923. A total of 20 of 54 (37.0%) non-surgical patients experienced tumor recurrence. Native T1 values (X1) (HR 1.012; 95% CI 1.007-1.016) and lymph node metastasis (X2) (HR 4.064; 95% CI 1.378-11.990) were independent tumor recurrence risk factors. The corresponding PI was calculated as follows: PI = 0.011X1 + 1.402X2; the Cox regression model AUC was 0.921. CONCLUSIONS: Native T1 values combined with conventional imaging and clinicopathologic variables could facilitate the pretreatment prediction of CC recurrence.


Asunto(s)
Recurrencia Local de Neoplasia , Neoplasias del Cuello Uterino , Femenino , Humanos , Recurrencia Local de Neoplasia/diagnóstico por imagen , Recurrencia Local de Neoplasia/cirugía , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/cirugía , Estudios de Seguimiento , Estudios Prospectivos , Imagen por Resonancia Magnética/métodos , Estudios Retrospectivos , Pronóstico
12.
Skeletal Radiol ; 52(12): 2451-2459, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37233758

RESUMEN

OBJECTIVES: To validate the subjective image quality and lesion detectability of deep learning-accelerated Dixon (DL-Dixon) imaging of the cervical spine compared with routine Dixon imaging. MATERIALS AND METHODS: A total of 50 patients underwent sagittal routine Dixon and DL-Dixon imaging of the cervical spine. Acquisition parameters were compared and non-uniformity (NU) values were calculated. Two radiologists independently assessed the two imaging methods for subjective image quality and lesion detectability. Interreader and intermethod agreements were estimated with weighted kappa values. RESULTS: Compared with the routine Dixon imaging, the DL-Dixon imaging reduced the acquisition time by 23.76%. The NU value is slightly higher in DL-Dixon imaging (p value: 0.015). DL-Dixon imaging showed superior visibility of all four anatomical structures (spinal cord, disc margin, dorsal root ganglion, and facet joint) for both readers (p value: < 0.001 ~ 0.002). The motion artifact scores were slightly higher in the DL-Dixon images than in routine Dixon images (p value = 0.785). Intermethod agreements were almost perfect for disc herniation, facet osteoarthritis, uncovertebral arthritis, central canal stenosis (κ range: 0.830 ~ 0.980, all p values < 0.001) and substantial to almost perfect for foraminal stenosis (κ = 0.955, 0.705 for each reader). There was an improvement in the interreader agreement of foraminal stenosis by DL-Dixon images, from moderate to substantial agreement. CONCLUSION: The DLR sequence can substantially decrease the acquisition time of the Dixon sequence with subjective image quality at least as good as the conventional sequence. And no significant differences in lesion detectability were observed between the two sequence types.


Asunto(s)
Aprendizaje Profundo , Imagen por Resonancia Magnética , Humanos , Imagen por Resonancia Magnética/métodos , Constricción Patológica/patología , Reproducibilidad de los Resultados , Vértebras Cervicales/diagnóstico por imagen , Vértebras Cervicales/patología
13.
Front Oncol ; 13: 1133709, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37007135

RESUMEN

Objectives: This study aimed to identify risk factors for recurrence in patients with cervical cancer (CC) through quantitative T1 mapping. Methods: A cohort of 107 patients histopathologically diagnosed with CC at our institution between May 2018 and April 2021 was categorized into surgical and non-surgical groups. Patients in each group were further divided into recurrence and non-recurrence subgroups depending on whether they showed recurrence or metastasis within 3 years of treatment. The longitudinal relaxation time (native T1) and apparent diffusion coefficient (ADC) value of the tumor were calculated. The differences between native T1 and ADC values of the recurrence and non-recurrence subgroups were analyzed, and receiver operating characteristic (ROC) curves were drawn for parameters with statistical differences. Logistic regression was performed for analysis of significant factors affecting CC recurrence. Recurrence-free survival rates were estimated by Kaplan-Meier analysis and compared using the log-rank test. Results: Thirteen and 10 patients in the surgical and non-surgical groups, respectively, showed recurrence after treatment. There were significant differences in native T1 values between the recurrence and non-recurrence subgroups in the surgical and non-surgical groups (P<0.05); however, there was no difference in ADC values (P>0.05). The areas under the ROC curve of native T1 values for discriminating recurrence of CC after surgical and non-surgical treatment were 0.742 and 0.780, respectively. Logistic regression analysis indicated that native T1 values were risk factors for tumor recurrence in the surgical and non-surgical groups (P=0.004 and 0.040, respectively). Compared with cut-offs, recurrence-free survival curves of patients with higher native T1 values of the two groups were significantly different from those with lower ones (P=0.000 and 0.016, respectively). Conclusion: Quantitative T1 mapping could help identify CC patients with a high risk of recurrence, supplementing information on tumor prognosis other than clinicopathological features and providing the basis for individualized treatment and follow-up schemes.

14.
NMR Biomed ; 36(8): e4918, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36914267

RESUMEN

PURPOSE: To evaluate the clinical feasibility of T1 mapping and extracellular volume fraction (ECV) measurement in assessing prognostic factors in patients with cervical squamous cell carcinoma (CSCC). MATERIALS AND METHODS: A total of 117 CSCC patients and 59 healthy volunteers underwent T1 mapping and diffusion-weighted imaging (DWI) on a 3 T system. Native T1 , contrast-enhanced T1 , ECV, and apparent diffusion coefficient (ADC) were calculated and compared based on surgico-pathologically verified deep stromal infiltration, parametrial invasion (PMI), lymphovascular space invasion (LVSI), lymph node metastasis, stage, histologic grade, and the Ki-67 labeling index (LI). RESULTS: Native T1 , contrast-enhanced T1 , ECV, and ADC values were significantly different between CSCC and the normal cervix (all p < 0.05). No significant differences were observed in any parameters of CSCC when the tumors were grouped by stromal infiltration or lymph node status, respectively (all p > 0.05). In subgroups of the tumor stage and PMI, native T1 was significantly higher for advanced-stage (p = 0.032) and PMI-positive CSCC (p = 0.001). In subgroups of the grade and Ki-67 LI, contrast-enhanced T1 was significantly higher for high-grade (p = 0.012) and Ki-67 LI ≥ 50% tumors (p = 0.027). ECV was significantly higher in LVSI-positive CSCC than in LVSI-negative CSCC (p < 0.001). ADC values showed a significant difference for the grade (p < 0.001) but none for the other subgroups. CONCLUSION: Both T1 mapping and DWI could stratify the CSCC histologic grade. In addition, T1 mapping and ECV measurement might provide more quantitative metrics for noninvasively predicting poor prognostic factors and aiding in preoperative risk assessment in CSCC patients.


Asunto(s)
Carcinoma de Células Escamosas , Neoplasias del Cuello Uterino , Femenino , Humanos , Antígeno Ki-67 , Imagen de Difusión por Resonancia Magnética , Carcinoma de Células Escamosas/diagnóstico por imagen , Carcinoma de Células Escamosas/patología , Neoplasias del Cuello Uterino/diagnóstico por imagen , Neoplasias del Cuello Uterino/patología , Pronóstico
15.
Diagnostics (Basel) ; 13(6)2023 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-36980314

RESUMEN

It is challenging to overcome motion artifacts in diffusion-weighted imaging (DWI) of the abdomen. This study aimed to evaluate the image quality of motion-corrected DWI of the liver using non-rigid registration in comparison with conventional DWI (c-DWI) in patients with liver diseases. Eighty-nine patients who underwent 3-T magnetic resonance imaging (MRI) of the liver were retrospectively included. DWI was performed using c-DWI and non-rigid motion-corrected (moco) DWI was performed in addition to c-DWI. The image quality and conspicuity of hepatic focal lesions were scored using a five-point scale by two radiologists and compared between the two DWI image sets. The apparent diffusion coefficient (ADC) was measured in three regions of the liver parenchyma and in hepatic focal lesions, and compared between the two DWI image sets. Moco-DWI achieved higher scores in image quality compared to c-DWI in terms of liver edge sharpness and hepatic vessel margin delineation. The conspicuity scores of hepatic focal lesions were higher in moco-DWI. The standard deviation values of ADC of the liver parenchyma were lower in the moco-DWI than in the c-DWI. Moco-DWI using non-rigid registration showed improved overall image quality and provided more reliable ADC measurement, with an equivalent scan time, compared with c-DWI.

16.
Diagnostics (Basel) ; 13(6)2023 Mar 15.
Artículo en Inglés | MEDLINE | ID: mdl-36980417

RESUMEN

Ultrafast (UF) dynamic contrast-enhanced (DCE)-MRI offers the potential for a faster and, therefore, less expensive examination of breast lesions; however, there are no reports that have evaluated whether UF DCE-MRI can be used the same as conventional DCE-MRI in the reading of morphological information. This study evaluated the agreement in morphological information obtained from malignant breast mass lesions between UF DCE-MRI and conventional DCE-MRI. UF DCE-MRI data were obtained over the first 60 s post-contrast injection, followed by the conventional DCE images. Two readers evaluated the size and morphology of the lesions in the final phase of the UF DCE-MRI and the early phase of the conventional DCE-MRI. Inter-method agreement in morphological information was evaluated for the two readers using the intraclass correlation coefficient for size, and the kappa statistics for the morphological descriptors. Differences in the proportion of each descriptor were examined using Fisher's test of independence. Most inter-method agreements were higher than substantial. UF DCE-MRI showed a circumscribed margin and homogeneous enhancement more often than conventional imaging. However, the percentages of readings showing the same morphology assessment between the UF DCE-MRI and conventional DCE-MRI were 71.2% (136/191) for Reader 1 and 69.1% (132/191) for Reader 2. We conclude that UF DCE-MRI may replace conventional DCE-MRI to evaluate the morphological information of malignant breast mass lesions.

17.
Invest Radiol ; 58(6): 373-379, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36728880

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the usefulness of breath-hold turbo spin echo with deep learning-based reconstruction (BH-DL-TSE) in acquiring fat-suppressed T2-weighted images (FS-T2WI) of the liver by comparing this method with conventional free-breathing turbo spin echo (FB-TSE) and breath-hold half Fourier single-shot turbo spin echo with deep learning-based reconstruction (BH-DL-HASTE). MATERIALS AND METHODS: The study cohort comprised 111 patients with suspected liver disease who underwent 3 T magnetic resonance imaging. Fifty-eight focal solid liver lesions ≥10 mm were also evaluated. Three sets of FS-T2WI were acquired using FB-TSE, prototypical BH-DL-TSE, and prototypical BH-DL-HASTE, respectively. In the qualitative analysis, 2 radiologists evaluated the image quality using a 5-point scale. In the quantitative analysis, we calculated the lesion-to-liver signal intensity ratio (LEL-SIR). Friedman test and Dunn multiple comparison test were performed to assess differences among 3 types of FS-T2WI with respect to image quality and LEL-SIR. RESULTS: The mean acquisition time was 4 minutes and 43 seconds ± 1 minute and 21 seconds (95% confidence interval, 4 minutes and 28 seconds to 4 minutes and 58 seconds) for FB-TSE, 40 seconds for BH-DL-TSE, and 20 seconds for BH-DL-HASTE. In the qualitative analysis, BH-DL-HASTE resulted in the fewest respiratory motion artifacts ( P < 0.0001). BH-DL-TSE and FB-TSE exhibited significantly less motion-related signal loss and clearer intrahepatic vessels than BH-DL-HASTE ( P < 0.0001). Regarding the edge sharpness of the left lobe, BH-DL-HASTE scored the highest ( P < 0.0001), and BH-DL-TSE scored higher than FB-TSE ( P = 0.0290). There were no significant differences among 3 types of FS-T2WI with respect to the edge sharpness of the right lobe ( P = 0.1290), lesion conspicuity ( P = 0.5292), and LEL-SIR ( P = 0.6026). CONCLUSIONS: BH-DL-TSE provides a shorter acquisition time and comparable or better image quality than FB-TSE, and could replace FB-TSE in acquiring FS-T2WI of the liver. BH-DL-TSE and BH-DL-HASTE have their own advantages and may be used complementarily.


Asunto(s)
Aprendizaje Profundo , Enfermedades del Sistema Digestivo , Hepatopatías , Humanos , Hepatopatías/diagnóstico por imagen , Abdomen , Respiración , Imagen por Resonancia Magnética/métodos , Artefactos
18.
Diagnostics (Basel) ; 13(2)2023 Jan 05.
Artículo en Inglés | MEDLINE | ID: mdl-36673011

RESUMEN

(1) Background: T1 mapping in magnetic resonance imaging (MRI) of the liver has been proposed to estimate liver function or to detect the stage of liver disease, among others. Thus far, the impact of intrahepatic fat on T1 quantification has only been sparsely discussed. Therefore, the aim of this study was to evaluate the potential of water-fat separated T1 mapping of the liver. (2) Methods: A total of 386 patients underwent MRI of the liver at 3 T. In addition to routine imaging techniques, a 3D variable flip angle (VFA) gradient echo technique combined with a two-point Dixon method was acquired to calculate T1 maps from an in-phase (T1_in) and water-only (T1_W) signal. The results were correlated with proton density fat fraction using multi-echo 3D gradient echo imaging (PDFF) and multi-echo single voxel spectroscopy (PDFF_MRS). Using T1_in and T1_W, a novel parameter FF_T1 was defined and compared with PDFF and PDFF_MRS. Furthermore, the value of retrospectively calculated T1_W (T1_W_calc) based on T1_in and PDFF was assessed. Wilcoxon test, Pearson correlation coefficient and Bland-Altman analysis were applied as statistical tools. (3) Results: T1_in was significantly shorter than T1_W and the difference of both T1 values was correlated with PDFF (R = 0.890). FF_T1 was significantly correlated with PDFF (R = 0.930) and PDFF_MRS (R = 0.922) and yielded only minor bias compared to both established PDFF methods (0.78 and 0.21). T1_W and T1_W_calc were also significantly correlated (R = 0.986). (4) Conclusion: T1_W acquired with a water-fat separated VFA technique allows to minimize the influence of fat on liver T1. Alternatively, T1_W can be estimated retrospectively from T1_in and PDFF, if a Dixon technique is not available for T1 mapping.

19.
J Magn Reson Imaging ; 58(4): 1055-1064, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-36651358

RESUMEN

BACKGROUND: Demand for prostate MRI is increasing, but scan times remain long even in abbreviated biparametric MRIs (bpMRI). Deep learning can be leveraged to accelerate T2-weighted imaging (T2WI). PURPOSE: To compare conventional bpMRIs (CL-bpMRI) with bpMRIs including a deep learning-accelerated T2WI (DL-bpMRI) in diagnosing prostate cancer. STUDY TYPE: Retrospective. POPULATION: Eighty consecutive men, mean age 66 years (47-84) with suspected prostate cancer or prostate cancer on active surveillance who had a prostate MRI from December 28, 2020 to April 28, 2021 were included. Follow-up included prostate biopsy or stability of prostate-specific antigen (PSA) for 1 year. FIELD STRENGTH AND SEQUENCES: A 3 T MRI. Conventional axial and coronal T2 turbo spin echo (CL-T2), 3-fold deep learning-accelerated axial and coronal T2-weighted sequence (DL-T2), diffusion weighted imaging (DWI) with b = 50 sec/mm2 , 1000 sec/mm2 , calculated b = 1500 sec/mm2 . ASSESSMENT: CL-bpMRI and DL-bpMRI including the same conventional diffusion-weighted imaging (DWI) were presented to three radiologists (blinded to acquisition method) and to a deep learning computer-assisted detection algorithm (DL-CAD). The readers evaluated image quality using a 4-point Likert scale (1 = nondiagnostic, 4 = excellent) and graded lesions using Prostate Imaging Reporting and Data System (PI-RADS) v2.1. DL-CAD identified and assigned lesions of PI-RADS 3 or greater. STATISTICAL TESTS: Quality metrics were compared using Wilcoxon signed rank test, and area under the receiver operating characteristic curve (AUC) were compared using Delong's test. SIGNIFICANCE: P = 0.05. RESULTS: Eighty men were included (age: 66 ± 9 years; 17/80 clinically significant prostate cancer). Overall image quality results by the three readers (CL-T2, DL-T2) are reader 1: 3.72 ± 0.53, 3.89 ± 0.39 (P = 0.99); reader 2: 3.33 ± 0.82, 3.31 ± 0.74 (P = 0.49); reader 3: 3.67 ± 0.63, 3.51 ± 0.62. In the patient-based analysis, the reader results of AUC are (CL-bpMRI, DL-bpMRI): reader 1: 0.77, 0.78 (P = 0.98), reader 2: 0.65, 0.66 (P = 0.99), reader 3: 0.57, 0.60 (P = 0.52). Diagnostic statistics from DL-CAD (CL-bpMRI, DL-bpMRI) are sensitivity (0.71, 0.71, P = 1.00), specificity (0.59, 0.44, P = 0.05), positive predictive value (0.23, 0.24, P = 0.25), negative predictive value (0.88, 0.88, P = 0.48). CONCLUSION: Deep learning-accelerated T2-weighted imaging may potentially be used to decrease acquisition time for bpMRI. EVIDENCE LEVEL: 3. TECHNICAL EFFICACY: Stage 2.


Asunto(s)
Aprendizaje Profundo , Neoplasias de la Próstata , Masculino , Humanos , Anciano , Persona de Mediana Edad , Imagen por Resonancia Magnética/métodos , Próstata/diagnóstico por imagen , Próstata/patología , Neoplasias de la Próstata/diagnóstico por imagen , Neoplasias de la Próstata/patología , Estudios Retrospectivos
20.
Eur Radiol ; 33(6): 4378-4388, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-36512042

RESUMEN

OBJECTIVES: To evaluate the recall rate and performance of free-breathing T1W dynamic imaging in patients who underwent gadoxetic acid-enhanced liver MRI. METHODS: We retrospectively reviewed patients who underwent free-breathing dynamic T1WI liver MRI using Cartesian (XD-VIBE) or self-gated radial (SG-GRASP) sequences at two institutions. Four radiologists independently reviewed the overall image quality, streak, and motion artifacts for precontrast, arterial, and portal venous phases on a 4-point scale. Hepatic observations were annotated and assessed according to LI-RADS v2018. RESULTS: In total, 360 patients were included (XD-VIBE [n = 253], SG-GRASP [n = 107]). The overall image quality of free-breathing T1WI was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. The actual recall rate was 0.6% (2/360). The SG-GRASP group showed fewer motion artifacts and more streak artifacts than the XD-VIBE group in all phases (p < 0.001 for all). The overall image quality was not significantly different between the two sequences in arterial (3.2 ± 0.4 in both, p = 0.607) and portal venous phases (3.5 ± 0.4 in XD-VIBE, 3.4 ± 0.4 in SG-GRASP, p = 0.214). Two sequences did not show significant differences in the lesion detection rate (figure of merit, FOM: 0.67 vs. 0.68, p = 0.876) or diagnostic performance for hepatocellular carcinoma (FOM: 0.55 vs. 0.62, p = 0.105). CONCLUSIONS: Both XD-VIBE and SG-GRASP provided sufficient image quality for patients at risk of developing motion artifacts, without significant differences in image quality or the lesion detection rate between sequences. KEY POINTS: • The overall image quality of free-breathing T1-weighted images using Cartesian or radial sequences was 3.4 ± 0.4, 3.2 ± 0.4, and 3.5 ± 0.4 for precontrast, arterial, and portal venous phases, respectively. • Only 0.3% (1/360) had undiagnostic exams and the actual recall rate was 0.6% (2/360) in patients who underwent free-breathing dynamic T1WI. • The overall lesion detection rate was 0.67 without a significant difference between Cartesian and radial sequences (figure of merit: 0.67 vs. 0.68, respectively, p = 0.876).


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Artefactos , Estudios Retrospectivos , Neoplasias Hepáticas/diagnóstico por imagen , Medios de Contraste/farmacología , Imagen por Resonancia Magnética/métodos , Aumento de la Imagen/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...