Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 680
Filtrar
1.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599688

RESUMEN

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Tricúspide , Humanos , Cateterismo Cardíaco/métodos , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/terapia , Insuficiencia Cardíaca/etiología , Resultado del Tratamiento , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Insuficiencia de la Válvula Tricúspide/cirugía , Estudios Multicéntricos como Asunto , Sistema de Registros
2.
Circ Cardiovasc Interv ; : e013794, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.

3.
Circ Cardiovasc Interv ; : e013156, 2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38629314

RESUMEN

BACKGROUND: We assessed the safety profile of tricuspid transcatheter edge-to-edge repair (TEER) in patients with right ventricular (RV) dysfunction. METHODS: We identified patients undergoing TEER to treat tricuspid regurgitation from June 2015 to October 2021 and assessed tricuspid annular plane systolic excursion (TAPSE) and RV fractional area change (RVFAC). RV dysfunction was defined as TAPSE <17 mm and RVFAC <35%. The primary end point was 30-day mortality after TEER. We also investigated the change in the RV function in the early phase and clinical outcomes at 2 years. RESULTS: The study participants (n=262) were at high surgical risk (EuroSCORE II, 6.2% [interquartile range, 4.0%-10.3%]). Among them, 44 patients met the criteria of RV dysfunction. Thirty-day mortality was 3.2% in patients with normal RV function and 2.3% in patients with RV dysfunction (P=0.99). Tricuspid regurgitation reduction to ≤2+ was consistently achieved irrespective of RV dysfunction (76.5% versus 70.5%; P=0.44). TAPSE and RVFAC declined after TEER in patients with normal RV function (TAPSE, 19.0±4.7 to 17.9±4.5 mm; P=0.001; RVFAC, 46.2%±8.1% to 40.3%±9.7%; P<0.001). In contrast, those parameters were unchanged or tended to increase in patients with RV dysfunction (TAPSE, 13.2±2.3 to 15.3±4.7 mm; P=0.011; RVFAC, 29.6%±4.1% to 31.6%±8.3%; P=0.14). Two years after TEER, compared with patients with normal RV function, patients with RV dysfunction had significantly higher mortality (27.0% versus 56.3%; P<0.001). CONCLUSIONS: TEER was safe and feasible to treat tricuspid regurgitation in patients with RV dysfunction. The decline in the RV function was observed in patients with normal RV function but not in patients with RV dysfunction.

5.
JACC Cardiovasc Interv ; 17(7): 890-903, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38599692

RESUMEN

BACKGROUND: Mitral transcatheter edge-to-edge repair (M-TEER) is a guideline-recommended treatment option for patients with severe symptomatic mitral regurgitation (MR). Outcomes with the PASCAL system in a post-market setting have not been established. OBJECTIVES: The authors report 30-day and 1-year outcomes from the MiCLASP (Transcatheter Repair of Mitral Regurgitation with Edwards PASCAL Transcatheter Valve Repair System) European post-market clinical follow-up study. METHODS: Patients with symptomatic, clinically significant MR were prospectively enrolled. The primary safety endpoint was clinical events committee-adjudicated 30-day composite major adverse event rate and the primary effectiveness endpoint was echocardiographic core laboratory-assessed MR severity at discharge compared with baseline. Clinical, echocardiographic, functional, and quality-of-life outcomes were assessed at 1 year. RESULTS: A total of 544 patients were enrolled (59% functional MR, 30% degenerative MR). The 30-day composite major adverse event rate was 6.8%. MR reduction was significant from baseline to discharge and sustained at 1 year with 98% of patients achieving MR ≤2+ and 82.6% MR ≤1+ (all P < 0.001 vs baseline). One-year Kaplan-Meier estimate for survival was 87.3%, and freedom from heart failure hospitalization was 84.3%. Significant functional and quality-of-life improvements were observed at 1 year, including 71.6% in NYHA functional class I/II, 14.4-point increase in Kansas City Cardiomyopathy Questionnaire score, and 24.2-m improvement in 6-minute walk distance (all P < 0.001 vs baseline). CONCLUSIONS: One-year outcomes of this large cohort from the MiCLASP study demonstrate continued safety and effectiveness of M-TEER with the PASCAL system in a post-market setting. Results demonstrate high survival and freedom from heart failure hospitalization, significant and sustained MR reduction, and improvements in symptoms, functional capacity, and quality of life.


Asunto(s)
Insuficiencia Cardíaca , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Estudios de Seguimiento , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Calidad de Vida , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Cardíaco/efectos adversos
7.
J Clin Med ; 13(5)2024 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-38592259

RESUMEN

Background: Minimally invasive mitral valve surgery (MIC-MVS) has been established as preferred treatment of mitral regurgitation (MR), but mitral transcatheter edge-to-edge valve repair (M-TEER) is routinely performed in patients at high surgical risk and is increasingly performed in intermediate risk patients. Methods: From 2010 to 2021, we performed 723 M-TEER and 123 isolated MIC-MVS procedures. We applied a sensitivity analysis by matching age, left ventricular ejection fraction (LVEF), EuroSCORE II and etiology of MR. Results: Baseline characteristics showed significant differences in the overall cohort (p < 0.01): age 78.3 years vs. 61.5 years, EuroSCORE II 5.5% vs. 1.3% and LVEF 48.4% vs. 60.4% in M-TEER vs. MIC-MVS patients. Grade of MR at discharge was moderate/severe in 24.5% (171/697) in M-TEER vs. 6.5% (8/123) in MIC-MVS (p < 0.01). One-year survival was 91.5% (552/723) in M-TEER vs. 97.6% (95/123) in MIC-MVS (p = 0.04). A matching with 49 pairs (n = 98) showed comparable survival during follow-up, but a numerically higher mean mitral valve gradient of 4.1 mmHg (95% CI: 3.6-4.6) vs. 3.4 mmHg (95% CI: 3.0-3.8) in M-TEER (p = 0.04). Conclusions: Patients undergoing M-TEER had lower one-year survival than MIC-MVS, but differences disappeared after matching. Reduction in MR was less effective in M-TEER patients and postprocedural mitral valve gradients were higher.

8.
Acta Physiol (Oxf) ; 240(5): e14140, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38546351

RESUMEN

AIM: Inflammation and calcification are hallmarks in the development of aortic valve stenosis (AVS). Ceramides mediate inflammation and calcification in the vascular tissue. The highly abundant d18:1,16:0 ceramide (C16) has been linked to increased cardiovascular mortality and obesity. In this study, we investigate the role of ceramide synthase 5 (CerS5), a critical enzyme for C16 ceramide synthesis, in the development of AVS, particularly in conjunction with a high-fat/high-cholesterol diet (Western diet, WD). METHODS: We used wild-type (WT) and CerS5-/- mice on WD or normal chow in a wire injury model. We measured the peak velocity to determine AVS development and performed histological analysis of the aortic valve area, immune cell infiltration (CD68 staining), and calcification (von Kossa). In vitro experiments involved measuring the calcification of human aortic valvular interstitial cells (VICs) and evaluating cytokine release from THP-1 cells, a human leukemia monocytic-like cell line, following CerS5 knockdown. RESULTS: CerS5-/- mice showed a reduced peak velocity compared to WT only in the experiment with WD. Likewise, we observed reduced immune cell infiltration and calcification in the aortic valve of CerS5-/- mice, but only on WD. In vitro, calcification was reduced after knockdown of CerS5 in VICs, while THP-1 cells exhibited a decreased inflammatory response following CerS5 knockdown. CONCLUSION: We conclude that CerS5 is an important mediator for the development of AVS in mice on WD and regulates critical pathophysiological hallmarks of AVS formation. CerS5 is therefore an interesting target for pharmacological therapy and merits further investigation.

9.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38437953

RESUMEN

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Asunto(s)
Cateterismo Cardíaco , Sistema de Registros , Insuficiencia de la Válvula Tricúspide , Válvula Tricúspide , Humanos , Masculino , Femenino , Válvula Tricúspide/diagnóstico por imagen , Válvula Tricúspide/cirugía , Anciano , Insuficiencia de la Válvula Tricúspide/cirugía , Insuficiencia de la Válvula Tricúspide/diagnóstico por imagen , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Resultado del Tratamiento , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Ecocardiografía/métodos
10.
Int J Cardiol ; 405: 131939, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38458388

RESUMEN

BACKGROUND: Advances in imaging have led to procedural optimization of left atrial appendage closure (LAAC). Contrast-free approaches, guided merely by echocardiography, have been established, however data on this topic remains scarce. In this analysis, we assessed contrast-free procedural results with the LAMBRE LAAC device. METHODS: The multicenter retrospective BoBoMa (Bonn/Bordeaux/Mainz)-Registry included a total of 118 patients that underwent LAAC with LAMBRE devices omitting contrast-dye. Baseline and echocardiographic characteristics as well as intra- and postprocedural complications and outcomes were assessed. RESULTS: Patients were at a mean age of 77.5 ± 7.5 years with high thromboembolic and bleeding risk (CHADS-VASc-score 4.6 ± 1.4, HAS-BLED-score 3.7 ± 1.0, respectively). Renal function was impaired with a mean glomerular filtration rate (GFR) of 50 ± 22 ml/min. Mean procedural time was 47.2 ± 37.5  minutes with a mean radiation dose of 4.75 ± 5.25 Gy*cm2. Device success, defined as proper deployment in a correct position, was achieved in 97.5% (115/118) of cases with repositioning of the occluder in 7.6% (9/118) and resizing in 3.4% (4/118) of cases. No relevant peri-device leakage (>3 mm) was observed with 42% of occluders being implanted in an ostial position. Periprocedural complications occurred in 6.8% (8/118) of cases, including two cases of device embolization and one case of clinically-relevant pericardial effusion requiring surgical intervention. Other complications included pericardial effusion (2.5%, 3/118) and vascular access site complications (1.7%, 2/118). CONCLUSION: Echocardiography-guided contrast-free LAAC using the LAMBRE device is safe and feasible. Further prospective studies including the direct comparison of devices as well as imaging techniques are warranted in contrast-free LAAC.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Dispositivo Oclusor Septal , Humanos , Apéndice Atrial/cirugía , Apéndice Atrial/diagnóstico por imagen , Masculino , Femenino , Anciano , Estudios Retrospectivos , Fibrilación Atrial/cirugía , Fibrilación Atrial/diagnóstico por imagen , Anciano de 80 o más Años , Sistema de Registros , Resultado del Tratamiento , Ecocardiografía Transesofágica/métodos , Medios de Contraste/administración & dosificación , Estudios de Seguimiento
11.
Eur J Heart Fail ; 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454641

RESUMEN

AIMS: Prognostic impact of post-procedural changes in right ventricular (RV) function after tricuspid transcatheter edge-to-edge repair (T-TEER) is still unclear. We investigated association of RV function and its post-procedural changes with clinical outcomes in patients undergoing T-TEER. METHODS AND RESULTS: We retrospectively analysed 204 patients who underwent T-TEER and echocardiographic follow-up at 3 months after T-TEER. RV function was assessed by RV fractional area change (RVFAC), and RV dysfunction was defined as RVFAC <35%. Patients with an increase in RVFAC from baseline to the follow-up were considered as RV responders. Patients were divided into four groups according to baseline RVFAC and the RV responder. The primary outcome was a composite of mortality and hospitalization due to heart failure within 1 year. Forty-five of 204 patients (22.1%) had RVFAC <35% at baseline, and 71 (34.8%) were RV responders. The association between the RV responder and the composite outcome had a significant interaction with RVFAC at baseline. Among patients with baseline RVFAC <35%, RV responders had a lower risk of the composite outcome than RV non-responders, while this association was not significant in those with baseline RVFAC ≥35%. Among patients with baseline RVFAC <35%, a smaller RV diameter and a greater reduction of tricuspid regurgitation were predictors for the RV responder. CONCLUSION: Post-procedural increase in RVFAC after T-TEER is associated with improved outcomes in patients with RV dysfunction. The factors related to the increase in RVFAC may support patient selection for T-TEER in patients with RV dysfunction.

12.
Angiology ; : 33197241239687, 2024 Mar 13.
Artículo en Inglés | MEDLINE | ID: mdl-38479438

RESUMEN

Stroke remains a clinical risk in the long-term follow-up of patients after transcatheter aortic valve implantation (TAVI). We aimed to investigate the association between existing carotid artery stenosis (CS) and the risk of stroke after TAVI. The study participants were consecutive patients who underwent TAVI between 2008 and 2020 and were screened for CS at baseline and at the 30-day follow-up. Hemodynamically relevant CS was defined as a reduction of the carotid artery caliber by >50% in relation to the distal segment. The primary endpoint of this study was ischemic stroke or transient ischemic attack (TIA) within 30 days of TAVI. Stroke-related death was also assessed. Of the 1,537 patients included, 220 (14.3%) patients had CS ≥50%. Within 30 days following TAVI, 41 patients (2.7%) experienced an ischemic stroke or TIA, and seven had stroke-related death. The median time from TAVI to stroke/TIA was 3.0 days. Patients with CS ≥50% had a 2.56-fold increased risk of stroke/TIA after TAVI (95%CI: 1.29-5.10, P = .006). The association was consistent in the multivariable model after adjusting for sex, atrial fibrillation, and estimated glomerular filtration rate. Investigations are needed to mitigate the risk of stroke in patients with CS ≥50%.

14.
EuroIntervention ; 20(4): e250-e260, 2024 Feb 19.
Artículo en Inglés | MEDLINE | ID: mdl-38389471

RESUMEN

BACKGROUND: The prognostic benefits of transcatheter edge-to-edge repair (TEER) remain unclear in patients with atrial functional mitral regurgitation (AFMR). AIMS: We aimed to investigate the clinical outcomes of TEER for patients with AFMR. METHODS: We retrospectively classified functional mitral regurgitation (FMR) patients undergoing TEER into those with AFMR or ventricular FMR (VFMR). A residual MR ≤1+ at discharge was considered optimal mitral regurgitation (MR) reduction, and an elevated mean mitral valve pressure gradient (MPG) was defined as an MPG ≥5 mmHg at discharge. The primary outcome was a composite of all-cause mortality and hospitalisation due to heart failure within one year. RESULTS: Of 441 FMR patients, 125 patients were considered as having AFMR. Residual MR ≤1+ was associated with a lower risk of the composite outcome in both AFMR and VFMR patients, while an MPG ≥5 mmHg was associated with a higher risk of the composite outcome in patients with AFMR but not with VFMR. AFMR patients with residual MR ≤1+ and an MPG ≥5 mmHg, as well as those with residual MR >1+, had a higher incidence of the composite outcome than those with residual MR ≤1+ and an MPG <5 mmHg (50.7%, 41.8%, and 14.3%, respectively; p<0.001). This association was consistent after adjustment for clinical and echocardiographic characteristics. CONCLUSIONS: An MR reduction to ≤1+ following TEER was associated with a lower risk of clinical outcomes in patients with AFMR, while an MPG ≥5 mmHg was related to a higher risk of clinical outcomes. Optimal MR reduction by TEER may have potential benefits on the prognosis of patients with AFMR, although the prognostic benefit may be attenuated by an elevated MPG.


Asunto(s)
Insuficiencia de la Válvula Mitral , Humanos , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Estudios Retrospectivos , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Atrios Cardíacos , Ventrículos Cardíacos
15.
PLoS One ; 19(2): e0286423, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38319942

RESUMEN

BACKGROUND: Interstitial lung disease (ILD) comprises a wide variety of pulmonary parenchymal disorders within which progressive fibrosing ILD (PF-ILD) constitutes a phenotypic subset. By use of speckle tracking-based strain analysis we aimed to evaluate the degree of left ventricular (LV) dysfunction in progressive vs. non-progressive fibrosing ILD (non-PF-ILD). METHODS: A total of 99 ILD patients (mean age 63.7 ± 13.5 years, 37.4% female), composed of 50 PF-ILD and 49 non-PF-ILD patients, and 33 controls were prospectively enrolled and underwent conventional and speckle tracking echocardiography. Additional laboratory and pulmonary function testing, as well as six-minute walk test were performed. RESULTS: As compared to the non-PF-ILD cohort, PF-ILD patients exhibited a significantly impaired forced vital capacity (2.4 ± 1.0l vs. 3.1 ± 0.9l, p = 0.002), diffusion capacity for carbon monoxide (DLCO, 25.6 ± 16.3% predicted vs. 43.6 ± 16.67% predicted, p <0.001) and exercise capacity response as measured by the six-minute walk test distance (268.1 ± 178.2m vs. 432.6 ± 94.2m, p <0.001). Contrary to conventional echocardiographic LV parameters, both regional and global longitudinal LV strain measurements were significantly altered in ILD patients as compared to controls. No differences in LV strain were found between both patient groups. Significant correlations were observed between global longitudinal strain, on the one hand, and systemic inflammation markers, total lung capacity (TLC) and DLCO, on the other hand (high-sensitivity C-reactive protein: Pearson´s r = -0.30, p< 0.001; interleukin-6: Pearson´s r = -0.26, p = 0.007; TLC % predicted: Pearson´s r = 0.22, p = 0.02; DLCO % predicted: Pearson´s r = 0.21, p = 0.02). CONCLUSIONS: ILD is accompanied by LV dysfunction. LV functionality inversely correlates with the severity of the restrictive ventilatory defect and inflammation marker levels. These observations support the assumption of persistent low-grade systemic inflammation that may link systemic cardiovascular function to ILD status.


Asunto(s)
Enfermedades Pulmonares Intersticiales , Disfunción Ventricular Izquierda , Humanos , Femenino , Persona de Mediana Edad , Anciano , Masculino , Enfermedades Pulmonares Intersticiales/complicaciones , Capacidad Vital , Función Ventricular Izquierda , Pruebas de Función Respiratoria , Inflamación/complicaciones , Pulmón , Estudios Retrospectivos
16.
JACC Cardiovasc Interv ; 17(5): 648-661, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38385922

RESUMEN

BACKGROUND: Early studies of the Tendyne transcatheter mitral valve replacement (TMVR) showed promising results in a small selective cohort. OBJECTIVES: The authors present 1-year data from the currently largest commercial, real-world cohort originating from the investigator-initiated TENDER (Tendyne European Experience) registry. METHODS: All patients from the TENDER registry eligible for 1-year follow-up were included. The primary safety endpoint was 1-year cardiovascular mortality. Primary performance endpoint was reduction of mitral regurgitation (MR) up to 1 year. RESULTS: Among 195 eligible patients undergoing TMVR (median age 77 years [Q1-Q3: 71-81 years], 60% men, median Society of Thoracic Surgeons Predicted Risk of Mortality 5.6% [Q1-Q3: 3.6%-8.9%], 81% in NYHA functional class III or IV, 94% with MR 3+/4+), 31% had "real-world" indications for TMVR (severe mitral annular calcification, prior mitral valve treatment, or others) outside of the instructions for use. The technical success rate was 95%. The cardiovascular mortality rate was 7% at 30 day and 17% at 1 year (all-cause mortality rates were 9% and 29%, respectively). Reintervention or surgery following discharge was 4%, while rates of heart failure hospitalization reduced from 68% in the preceding year to 25% during 1-year follow-up. Durable MR reduction to ≤1+ was achieved in 98% of patients, and at 1 year, 83% were in NYHA functional class I or II. There was no difference in survival and major adverse events between on-label use and "real-world" indications up to 1 year. CONCLUSIONS: This large, real-world, observational registry reports high technical success, durable and complete MR elimination, significant clinical benefits, and a 1-year cardiovascular mortality rate of 17% after Tendyne TMVR. Outcomes were comparable between on-label use and "real-world" indications, offering a safe and efficacious treatment option for patients without alternative treatments. (Tendyne European Experience Registry [TENDER]; NCT04898335).


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Mitral , Masculino , Humanos , Anciano , Femenino , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Cateterismo Cardíaco/métodos , Sistema de Registros
17.
J Thorac Imaging ; 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38389116

RESUMEN

PURPOSE: Inflammatory changes in epicardial (EAT) and pericardial adipose tissue (PAT) are associated with increased overall cardiovascular risk. Using routine, preinterventional cardiac CT data, we examined the predictive value of quantity and quality of EAT and PAT for outcome after transcatheter aortic valve replacement (TAVR). MATERIALS AND METHODS: Cardiac CT data of 1197 patients who underwent TAVR at the in-house heart center between 2011 and 2020 were retrospectively analyzed. The amount and density of EAT and PAT were quantified from single-slice CT images at the level of the aortic valve. Using established risk scores and known independent risk factors, a clinical benchmark model (BMI, Chronic kidney disease stage, EuroSCORE 2, STS Prom, year of intervention) for outcome prediction (2-year mortality) after TAVR was established. Subsequently, we tested whether the additional inclusion of area and density values of EAT and PAT in the clinical benchmark model improved prediction. For this purpose, the cohort was divided into a training (n=798) and a test cohort (n=399). RESULTS: Within the 2-year follow-up, 264 patients died. In the training cohort, particularly the addition of EAT density to the clinical benchmark model showed a significant association with outcome (hazard ratio 1.04, 95% CI: 1.01-1.07; P =0.013). In the test cohort, the outcome prediction of the clinical benchmark model was also significantly improved with the inclusion of EAT density (c-statistic: 0.589 vs. 0.628; P =0.026). CONCLUSIONS: EAT density as a surrogate marker of EAT inflammation was associated with 2-year mortality after TAVR and may improve outcome prediction independent of established risk parameters.

18.
Clin Res Cardiol ; 2024 Feb 15.
Artículo en Inglés | MEDLINE | ID: mdl-38358420

RESUMEN

INTRODUCTION: Cryoballoon (CB) ablation has become a popular method for pulmonary vein isolation (PVI) in atrial fibrillation (AF) treatment. This study aimed to compare the intraprocedural ablation characteristics of two cryoballoons, Arctic Front Advance Pro™ (AFA-Pro, Medtronic) and POLARx™ (Boston Scientific). METHODS AND RESULTS: In this retrospective single-center study, 230 symptomatic paroxysmal or persistent AF patients underwent CB ablation with either AFA-Pro or POLARx. Propensity-score matching resulted in two cohorts of 114 patients each. Baseline and procedural characteristics were comparable between both CBs. POLARx achieved lower minimal temperatures (e.g., left superior pulmonary vein, LSPV: AFA-Pro - 49.0 °C vs. POLARx - 59.5 °C) and lower temperatures at time-to-isolation (TTI). Additionally, POLARx reached lower temperatures faster, as evidenced by lower temperatures after 40 and 60 s, and a larger mean temperature change between 20 and 40 s. POLARx also had a greater area under the curve below 0 °C and a longer thawing phase. Both CBs achieved comparable high rates of final PV-isolation. TTI, minimal esophagus temperature, and first-pass isolation rates were similar between groups. Periprocedural complications, including phrenic nerve injuries, were comparable. Troponin levels in the left atrium were elevated with both systems. Values and change in troponin were numerically higher in the POLARx group (delta troponin: AFA-Pro 36.3 (26.4, 125.4) ng/L vs. POLARx 104.9 (49.5, 122.2) ng/L), p = 0.077). CONCLUSION: AFA-Pro and POLARx are both highly effective and safe CB systems for PVI. POLARx exhibited significant faster and lower freezing characteristics, and numerically higher troponin levels might indicate greater myocardial injury. However, these differences did not translate into improved performance, procedural efficiency, or safety.

19.
J Am Heart Assoc ; 13(3): e031997, 2024 Feb 06.
Artículo en Inglés | MEDLINE | ID: mdl-38240198

RESUMEN

BACKGROUND: Aortic stenosis has pathophysiological similarities with atherosclerosis, including the deposition of cholesterol-containing lipoproteins. The resulting cholesterol crystals activate the NLRP3 (NOD-like receptor protein 3) inflammasome, leading to inflammation and cardiovascular diseases. We aimed to investigate the cholesterol crystal dissolution rate (CCDR) of serum in patients with aortic stenosis and to assess the prognostic value of this biomarker. METHODS AND RESULTS: The study included 348 patients with aortic stenosis undergoing transcatheter aortic valve replacement. The CCDR was measured using flow cytometry to enumerate cholesterol crystals that were added to a serum solution, at baseline and after 2 hours of incubation. Based on the median CCDR, the cohort was stratified into high and low cholesterol crystal dissolvers. The incidence of the primary end point, a composite of 1-year all-cause mortality and major vascular complication, was significantly lower in the high CCDR group (7.3 per 100 person-years) compared with the low CCDR group (17.0 per 100 person-years, P=0.01). This was mainly driven by a lower 1-year mortality rate in patients with a high CCDR (7.3 versus 15.1 per 100 person-years, P=0.04). Unplanned endovascular interventions were significantly less frequent in high cholesterol crystal dissolvers (12.8 versus 22.6 per 100 person-years, P=0.04). Although low-density lipoprotein cholesterol levels were comparable in both groups (101.8±37.3 mg/dL versus 97.9±37.6 mg/dL, P=0.35), only patients with a low CCDR showed a benefit from statin treatment. In multivariate analysis, low CCDR (hazard ratio, 2.21 [95% CI, 0.99-4.92], P=0.04) was significantly associated with 1-year mortality. CONCLUSIONS: The CCDR is a novel biomarker associated with outcome in patients with aortic stenosis undergoing transcatheter aortic valve replacement. It may provide new insights into patients' anti-inflammatory capacity and additional prognostic information beyond classic risk assessment.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Resultado del Tratamiento , Medición de Riesgo , Biomarcadores , Válvula Aórtica/cirugía , Factores de Riesgo
20.
Clin Res Cardiol ; 113(1): 1-10, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36645506

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) has emerged as alternative to transcatheter edge-to-edge repair (TEER) for treatment of mitral regurgitation (MR); however, the role of TMVR with the Tendyne system among established treatments of MR is not well defined. We assessed characteristics and outcomes of patients treated with the Tendyne system in the current clinical practice. METHODS: We reviewed patients who underwent cardiac computed tomography and were judged eligible for the Tendyne system. RESULTS: A total of 63 patients were eligible for TMVR with the Tendyne system. Of these, 17 patients underwent TMVR, and 46 were treated by TEER. Patients treated with the Tendyne system were more likely to have a high transmitral pressure gradient and unsuitable mitral valve morphology for TEER than those treated with TEER. TMVR with the Tendyne system reduced the severity of MR to less than 1 + in 94.1% of the patients at discharge and achieved a greater reduction in left ventricular (LV) end-diastolic volume at the 30-day follow-up compared with TEER. In contrast, patients treated with the Tendyne system had a higher 30-day mortality than those treated with TEER, while the mortality between 30 days and one year was comparable between Tendyne and TEER. CONCLUSIONS: Among patients eligible for the Tendyne system, approximately a quarter of the patients underwent TMVR with the Tendyne system, which led substantial reduction of MR and LV reverse remodeling than TEER. In contrast, the 30-day mortality rate was higher after TMVR with the Tendyne compared to TEER.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Humanos , Válvula Mitral/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Cateterismo Cardíaco/métodos , Resultado del Tratamiento , Insuficiencia de la Válvula Mitral/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...