1.
Sleep Med ; 119: 139-146, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38678757

RESUMEN

BACKGROUND: Intraoral devices, with or without negative oral pressure, can stabilize the oropharynx and reduce obstructive sleep apneas. We tested the hypothesis that treatment with the iNAP® Sleep Therapy System, which applies negative oral pressure through an intra-oral appliance, would reduce the severity of obstructive sleep apnea in a multi-center, prospective, first-night-randomized-order cross-over study. METHODS/PATIENTS: 130 patients fulfilled the entry criteria (age <75, AHI 15-55, BMI <33), and 63 entered the primary endpoint cohort (Total Sleep Time ≥4 h/night on the baseline polysomnogram and an oral negative vacuum time maintained by iNAP® ≥ 4 h/night and total sleep time ≥4 h/night during the first treatment study). 54 patients completed a second treatment sleep study at least 28 days after the first sleep study. RESULTS: Among the primary endpoint cohort (n = 63, age = 53.2 ± 11.3, BMI = 27.1 ± 2.8), 33 patients (52 %; 95 % confidence interval = 40%-64 %, p < 0.001) responded to iNAP treatment according to the Sher criteria (>50 % reduction in AHI and an AHI ≤20 events/hr). The average oxy-hemoglobin saturation increased by 1-2%, and the average percent oxygen desaturation decreased (was less severe) by 1 % while using the iNAP device. The incidence of adverse events, all self-limited, was low. The reduction in the apnea-hypopnea index was durable over the 28-day study. Patients used iNAP on average 5.6 h per night during the study period. CONCLUSION: The iNAP® Sleep Therapy System achieved a durable benefit in more than half the patients with moderate to severe obstructive sleep apnea and may be considered in patients who object to or failed continuous positive airway pressure. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02698059.


Asunto(s)
Estudios Cruzados , Polisomnografía , Apnea Obstructiva del Sueño , Humanos , Apnea Obstructiva del Sueño/terapia , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento , Anciano , Adulto
2.
Biomacromolecules ; 25(3): 1578-1591, 2024 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-38333985

RESUMEN

Muco-obstructive diseases change airway mucus properties, impairing mucociliary transport and increasing the likelihood of infections. To investigate the sorption properties and nanostructures of mucus in health and disease, we investigated mucus samples from patients and cell cultures (cc) from healthy, chronic obstructive pulmonary disease (COPD), and cystic fibrosis (CF) airways. Atomic force microscopy (AFM) revealed mucin monomers with typical barbell structures, where the globule to spacer volume ratio was the highest for CF mucin. Accordingly, synchrotron small-angle X-ray scattering (SAXS) revealed more pronounced scattering from CF mucin globules and suggested shorter carbohydrate side chains in CF mucin and longer side chains in COPD mucin. Quartz crystal microbalance with dissipation (QCM-D) analysis presented water sorption isotherms of the three types of human airway mucus, where, at high relative humidity, COPD mucus had the highest water content compared to cc-CF and healthy airway mucus (HAM). The higher hydration of the COPD mucus is consistent with the observation of longer side chains of the COPD mucins. At low humidity, no dehydration-induced glass transition was observed in healthy and diseased mucus, suggesting mucus remained in a rubbery state. However, in dialyzed cc-HAM, a sorption-desorption hysteresis (typically observed in the glassy state) appeared, suggesting that small molecules present in mucus suppress the glass transition.


Asunto(s)
Fibrosis Quística , Enfermedad Pulmonar Obstructiva Crónica , Humanos , Agua/química , Dispersión del Ángulo Pequeño , Difracción de Rayos X , Moco/metabolismo , Enfermedad Pulmonar Obstructiva Crónica/metabolismo , Mucinas/química
3.
Pneumologie ; 2024 Feb 21.
Artículo en Alemán | MEDLINE | ID: mdl-38382563

RESUMEN

Acute dyspnoea is one of the most common internal medicine symptoms in the emergency department. It arises from an acute illness or from the exacerbation of a chronic illness. Symptom-related emergency structures and corresponding structural guidelines already exist in the stroke and chest pain units for dealing with the leading symptoms of acute stroke and acute chest pain. These are lacking in Germany for the key symptom of dyspnoea, although the benefits of these structures have already been proven in other countries. The German Society for Pneumology and Respiratory Medicine (DGP) has now set up a task force together with the Association of Pneumology Clinics (VPK), in order to deal with the topic and develop appropriate structural guidelines for such "dyspnoea units" in Germany. At the end of the process, the certification of such units at German hospitals is optional.

4.
MMW Fortschr Med ; 166(1): 28, 2024 01.
Artículo en Alemán | MEDLINE | ID: mdl-38261195
5.
MMW Fortschr Med ; 165(21-22): 36, 2023 12.
Artículo en Alemán | MEDLINE | ID: mdl-38064073
6.
J Appl Physiol (1985) ; 134(2): 365-377, 2023 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-36633864

RESUMEN

Positive airway pressure that dynamically changes with breathing, and clearance of anatomical dead space are the key mechanisms of noninvasive respiratory support with nasal high flow (NHF). Pressure mainly depends on flow rate and nare occlusion. The hypothesis is that an increase in asymmetrical occlusion of the nares leads to an improvement in dead-space clearance resulting in a reduction in re-breathing. Clearance was investigated with volumetric capnography in an adult upper-airway model, which was ventilated by a lung simulator with entrained carbon dioxide (CO2) at respiratory rates (RR) of 15-45 min-1 and at 18 min-1 with chronic obstructive pulmonary disease (COPD) breathing patterns. Clearance was assessed at NHF of 20-60 L/min with a symmetrical interface (SI) and an asymmetrical interface (AI). CO2 kinetics visualized by infrared spectroscopy and mathematical modeling were used to study the mechanisms of clearance. At a higher RR (35 min-1) and NHF of 60 L/min, clearance in the upper airway was significantly higher with the AI when compared with the SI (29.64 ± 9.96%, P < 0.001), as opposed to at a lower RR (15 min-1) (1.40 ± 6.25%, P > 0.05), (means ± SD). With COPD breathing, clearance by NHF was reduced but significantly improved with the AI by 45.93% relative to the SI at NHF 20 L/min (P < 0.0001). The maximum pressure achieved with the AI was 6.6 cmH2O and NHF was 60 L/min at the end of expiration. Pressure differences between nasal cavities led to the reverse flow observed in the optical model. Asymmetrical NHF increases dead-space clearance by reverse flow through the choanae and accelerates purging of expired gas via the less occluded nare.NEW & NOTEWORTHY The asymmetrical interface generated reverse flow in the nasal cavities and across the choana, which led to unidirectional purging of expired gas from the upper airways. This accelerated the clearance of anatomical dead space and reduced re-breathing while increased resistance to flow resulted in higher positive end-expiratory pressure (PEEP). These findings are relevant to patients with elevated respiratory rates or with expiratory flow limitations where dead-space clearance by NHF can be substantially reduced.


Asunto(s)
Dióxido de Carbono , Enfermedad Pulmonar Obstructiva Crónica , Adulto , Humanos , Cinética , Pulmón , Respiración , Enfermedad Pulmonar Obstructiva Crónica/terapia
7.
Sleep Breath ; 27(4): 1639-1650, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-36394692

RESUMEN

PURPOSE: Monitored polysomnography (PSG) is considered the gold standard technique to diagnose obstructive sleep apnea (OSA) and titrate continuous positive airway pressure (CPAP), the accepted primary treatment method. Currently, the American Academy of Sleep Medicine (AASM) considers automatic PAP therapy initiation at home comparable to laboratory titration and recommends telemonitoring-guided interventions. Advanced CPAP devices evaluate and report the residual apnea-hypopnea index (AHI). However, in order to control the effectiveness of the prescribed therapy outside of a PSG setting, the automatic event detection must provide reliable data. METHODS: A CPAP titration was performed in the sleep laboratory by PSG in patients with OSA. The residual event indices detected by the tested device (prismaLine, Loewenstein Medical Technology) were compared to the manually scored PSG indices. Results of the device (AHIFLOW) were compared according to the AASM scoring criteria 1A (AHI1A, hypopneas with a flow signal reduction of ≥ 30% with ≥ 3% oxygen reduction and/or an arousal) and 1B (AHI1B, hypopneas with a flow signal decrease by ≥ 30% with a ≥ 4% oxygen desaturation). RESULTS: In 50 patients with OSA, the mean PSG AHI1A was 10.5 ± 13.8/h and the PSG AHI1B was 7.4 ± 12.6/h compared to a mean device AHIFlow of 8.4 ± 10.0/h. The correlation coefficient regarding PSG AHI1A and AHIFlow was 0.968. The correlation regarding central hypopneas on the other hand was 0.153. There were few central events to be compared in this patient group. CONCLUSION: The device-based analysis showed a high correlation in the determination of residual obstructive AHI under therapy. The recorded residual respiratory event indices in combination with the data about leakage and adherence of the studied device provide reliable information for the implementation and follow-up of CPAP therapy in a typical group of patients with OSA. TRIAL REGISTRATION NUMBER: ClinicalTrials.gov Identifier: NCT04407949, May 29, 2020, retrospectively registered.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua , Apnea Obstructiva del Sueño , Humanos , Oxígeno , Polisomnografía/métodos , Reproducibilidad de los Resultados , Apnea Obstructiva del Sueño/diagnóstico , Apnea Obstructiva del Sueño/terapia
8.
Lung ; 200(2): 251-260, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35246760

RESUMEN

INTRODUCTION: To increase CO2 elimination and to reduce work of breathing in hypercapnic patients, non-invasive ventilation (NIV) can be applied via mask either with non-vented CO2 exhalation systems or with vented systems with leak port. The effect of the exhalation system on CO2 rebreathing in the mask and total gas exchange remains widely unknown. Aim of this study was to compare the exhalation systems in terms of inspiratory O2 and CO2 concentrations, breathing patterns and gas exchange. METHODS: We prospectively examined 10 healthy subjects and 10 hypercapnic patients with both exhalation systems. O2 and CO2 were measured in the nose, in the mask, and in the ventilation circuit, and respiratory rate, tidal volume, and transcutaneous capnometry (PtcCO2) were recorded during the experiments. RESULTS: Using the non-vented system, CO2 concentrations in the mask were significantly higher in both subject groups, and PtcCO2 values in the patient group increased up to 3.6 mmHg compared to the vented system (p = 0.011). O2 concentrations increased with higher O2 flow rates, but were significantly lower in the vented settings in both groups. No effect in breathing pattern could be demonstrated during the measurement time. CONCLUSION: Using NIV, the chosen exhalation system influences CO2 and O2 concentrations under the mask, CO2 rebreathing from the mask and could influence the effectiveness of the ventilation support with regards to hypercapnia treatment. To compensate for relevant hypoxia, the O2 supplementation must be set up to a sufficient level under a vented system.


Asunto(s)
Ventilación no Invasiva , Dióxido de Carbono , Espiración , Humanos , Hipercapnia/terapia , Respiración con Presión Positiva , Respiración
9.
J Clin Sleep Med ; 18(6): 1531-1537, 2022 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-35088707

RESUMEN

STUDY OBJECTIVES: Previous estimated prevalence of narcolepsy in Europe was 47 patients per 100,000 persons, with a yearly incidence of 0.64-1.37 per 100,000. However, analyses of representative datasets from large cohorts are limited. This study aimed to estimate the population-based diagnostic prevalence and incidence of narcolepsy in Germany and to describe these patients and their health care resource utilization. METHODS: This study used the InGef research database, an anonymized representative dataset of 4 million persons covered by statutory health insurance in Germany. Patients with confirmed narcolepsy diagnoses in 2018 were included. Mid-p-exact tests were used to calculate 95% confidence intervals. Patients with narcolepsy diagnoses and narcolepsy-targeting therapy in 2014-2018 were included to describe health care resource utilization in the year prior to diagnosis. RESULTS: In 2018, diagnostic prevalence was estimated as 17.88 (95% confidence interval 16.45-19.40) and 12-month incidence as 0.79 (0.52-1.15) per 100,000 persons. Forty-six percent of patients were in psycho-behavioral therapeutic treatment and 61% of employees had sick leave days. One in three patients was hospitalized for any cause; 28% received antibiotics. CONCLUSIONS: Diagnostic prevalence was lower, but incidence was consistent with previous reports, although previous estimates may diverge in terms of age/sex distributions. Patients showed a substantial utilization of health care resources, including sick leave and hospitalization. Almost half the patients underwent psycho-behavioral treatment in the year prior to diagnosis, which might indicate a high burden of psychiatric symptoms. The increased use of antibiotics could indicate more frequent infections than in the general population. CITATION: Kallweit U, Nilius G, Trümper D, Vogelmann T, Schubert T. Prevalence, incidence, and health care utilization of patients with narcolepsy: a population-representative study. J Clin Sleep Med. 2022;18(6):1531-1537.


Asunto(s)
Narcolepsia , Antibacterianos/uso terapéutico , Atención a la Salud , Humanos , Incidencia , Narcolepsia/diagnóstico , Narcolepsia/epidemiología , Narcolepsia/terapia , Aceptación de la Atención de Salud , Prevalencia
11.
J Appl Physiol (1985) ; 132(2): 553-563, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-35085029

RESUMEN

Nasal high flow (NHF) is an efficient oxygenation tool for the treatment of respiratory failure. The study investigated the effect of breathing pattern on positive airway pressure and dead-space clearance by NHF. The breathing cycle during NHF was characterized in 26 patients with acute respiratory failure (ARF) and stable COPD and after mechanical ventilation (post-MV) via tracheostomy where also pressure was measured in the trachea. Dead-space clearance was measured in airway models during different breathing patterns. NHF reduced the respiratory rate (RR) and TI/TE through prolonging the TE; the TI/TE ranged between ≤0.5 observed in the COPD patients and ∼1.0 in the ARF patients. NHF via a standard medium-sized cannula interface generated a low-level expiratory pressure proportional to NHF rate and breathing flow; the median generated positive end-expiratory pressure was only 1.71 cmH2O at NHF 45 L/min. The dilution and purging of expired gas from a nasal cavity model were observed to occur at the end of expiration as expiratory flow slowed and the dynamic pressure decreased. The higher RR with shorter end-expiratory period resulted in reduced dead-space clearance by NHF; 20 L/min cleared 43 ± 2 mL at RR 15 min-1 vs. 9 ± 5 mL at RR 45 min-1, P < 0.001, which was increased at higher NHF rate. At lower RR, the clearance was similar between NHF rates 20 and 60 L/min. Higher NHF rates elevate positive airway pressure, and at the increased RR can improve the clearance. This may enhance gas exchange and lead to a reduction in the work of breathing.NEW & NOTEWORTHY During nasal high flow (NHF) an increased breathing frequency, which is commonly observed in acute respiratory failure, can lead to decreased dead-space clearance. Higher NHF rates increase the clearance and reduce the rebreathing which may eventually lower the respiratory rate and the work of breathing. Monitoring of the respiratory rate could be an important indicator of not only the respiratory function but also the NHF rate selection and the therapy efficacy.


Asunto(s)
Enfermedad Pulmonar Obstructiva Crónica , Insuficiencia Respiratoria , Cánula , Humanos , Respiración , Insuficiencia Respiratoria/terapia , Frecuencia Respiratoria
12.
Pneumo News ; 13(6): 10-11, 2021.
Artículo en Alemán | MEDLINE | ID: mdl-34925624
13.
14.
Curr Opin Pulm Med ; 27(6): 523-528, 2021 11 01.
Artículo en Inglés | MEDLINE | ID: mdl-34494980

RESUMEN

PURPOSE OF REVIEW: The COVID-19 pandemic has clearly demonstrated that the technological progress in digitization is also essential for the medical sector. In the field of sleep-disordered breathing, the novel eHealth methods already do offer smart solutions for currently insufficiently addressed problems. RECENT FINDINGS: In general, the potential of telemedicine tools can be focused on three basic aspects: interaction between clinicians, interaction between clinician and patient, and interaction between patient and the mobile health technology. The pandemic situation resulted in a rapid development of reimbursement for telehealth services. In recent years, evidence on the positive benefits of using telemedicine-based support as part of respiratory therapy follow-up is increasing. It is important to consider patient groups, telemedicine methodology, type of intervention, and targeting criteria in all studies conducted. SUMMARY: Given the scarcity of resources for leading common diseases, we must keep an eye on the new digitization concepts in respiratory medicine care. It must be implemented precisely, cost-effectively, and also more connecting between sectors and disciplines and at eye level with our patients. By means of patient engagement systems, an important part of modern precision medicine can be established. Digital support systems are valuable for supporting medical staff. They are not meant to replace medical staff but to facilitate their work and improve its quality.


Asunto(s)
COVID-19 , Neumología , Telemedicina , Humanos , Pandemias , SARS-CoV-2 , Sueño
15.
Pneumo News ; 13(3): 12-13, 2021.
Artículo en Alemán | MEDLINE | ID: mdl-34149942
17.
Nat Sci Sleep ; 13: 751-762, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34135650

RESUMEN

Sleep disorders and circadian dysrhythmias are extremely prevalent in critically ill patients. Impaired sleep has a variety of etiologies, exhibits a wide range of negative effects and, moreover, might deteriorate the patient's prognosis. Despite a number of scientific findings and increased awareness, the importance of sleep optimization is still lower on the list of priories in the intensive care unit (ICU). The techniques of measuring and the evaluation of sleep quantity and quality are a great challenge in the ICU setting. The subjective and objective tools of sleep validation continue to suffer from deficiencies. Treatment approaches to improve the critically ill patient's sleep have focused on non-pharmacologic and pharmacologic strategies with some promising results. But pharmacological interventions alone could not provide sufficient patient benefit. Being aware and knowing of sleep problems and the beneficial effect of the necessary therapies in ICU patients requires greater acceptance. The application of available methods and the development of new methods to prevent sleep disorders in the ICU offer the potential to improve the critically ill patient's outcome.

18.
Pneumo News ; 13(2): 14-16, 2021.
Artículo en Alemán | MEDLINE | ID: mdl-33968265
19.
Sleep Breath ; 25(2): 727-735, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-32845475

RESUMEN

PURPOSE: Treatment of advanced pulmonary emphysema with endobronchial coils can improve clinical outcomes like quality of life (QOL). Yet, patients with chronic obstructive pulmonary disease (COPD) are also known to suffer from reduced sleep quality. The effect of coil therapy on sleep has not yet been investigated. The primary aim of this study was to investigate sleep efficiency before and after coil treatment. Secondly, we investigated the effects on nocturnal breathing pattern, QOL, and physical activity. METHODS: Polysomnography (PSG) testing was performed before (T0), 6 month after (T3), and 12 months after (T4) treatment with endobronchial coils. Further examinations included QOL by St George's Respiratory Questionnaire (SGRQ) and COPD assessment test (CAT), and physical activity using an accelerometer for 1 week after each visit. RESULTS: Of 21 patients, 14 completed the study: 6 women; mean age 58.0 ± 4.9 years; BMI 22.6 ± 4.6 kg/m2; FEV1 28.6 ± 7.1% predicted; residual volume (RV) 278.2 ± 49.4% predicted. Sleep efficiency did not vary between baseline and follow-up examinations (T0 69.0 ± 15.8%; T3 70.9 ± 16.0%; T4 66.8 ± 18.9%). Non-REM respiratory rate decreased compared to baseline (T0 19.4 ± 3.9/min; T3 17.8 ± 3.5/min; T4 17.1 ± 3.1/min (p = 0.041; p = 0.030) and QOL improved meeting the minimal clinically important difference (MCID) (SGRQ, T3 -12.8 units; T4 -7.1 units; CAT: T3 -5.6 units; T4 -3.4 units). No increase in physical activity was recorded (light activity T0 31.9 ± 9.9; T3 30.8 ± 16.9; T4 26.3 ± 10.6 h/week). CONCLUSIONS: Treatment with endobronchial coils did not influence objectively measured sleep quality or physical activity, but reduced nocturnal breathing frequency and improved QOL in severe emphysema patients. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02399514, First Posted: March 26, 2015.


Asunto(s)
Neumonectomía/métodos , Enfermedad Pulmonar Obstructiva Crónica/fisiopatología , Enfisema Pulmonar/cirugía , Sueño/fisiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Enfisema Pulmonar/fisiopatología , Calidad de Vida , Calidad del Sueño , Encuestas y Cuestionarios , Resultado del Tratamiento
20.
Sleep Breath ; 24(3): 941-951, 2020 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31463779

RESUMEN

PURPOSE: A nocturnal non-dipping or rise in blood pressure (BP) is associated with poor cardiovascular outcome. This study aimed to test whether continuous positive airway pressure (CPAP) therapy can reduce nocturnal BP and normalize the 24-h BP profile in patients with severe obstructive sleep apnea (OSA) and erectile dysfunction as a surrogate for endothelial dysfunction (ED). PATIENTS AND METHODS: Eighteen consecutive patients with OSA and ED on stable antihypertensive medication (age 55.8 ± 9.5 years, body mass index 35.5 ± 3.8 kg/m2, apnea-hypopnoea index 66.1 ± 27.4/h) were treated with CPAP for 6 months (average daily use 5.8 ± 2.3 h). Twenty-four hour BP recordings were performed using a portable monitoring device. Rising was defined as an increase, whereas non-dipping was defined as a fall in nocturnal BP of less than 10% compared to daytime values. Serum noradrenaline levels as markers of sympathetic activity were measured at baseline and at 6 month follow up. RESULTS: Compared to baseline, nocturnal systolic and diastolic BP were significantly reduced after CPAP therapy (128.5 ± 14 to 122.9 ± 11 mmHg, p = 0.036; 76.2 ± 9 to 70.5 ± 5 mmHg, p = 0.007). The frequency of non-dipping and rising nocturnal systolic BP, as well as mean nocturnal heart rate, was reduced after CPAP treatment (73 to 27%, p = 0.039; 20 to 7%, p = 0.625; from 81.5 ± 10 to 74.8 ± 8 beats per minute p = 0.043). Serum levels of noradrenaline were significantly lower after CPAP therapy (398 ± 195 ng/l vs. 303 ± 135 ng/l, p = 0.032). CONCLUSION: In patients with severe OSA and clinically apparent ED, CPAP therapy was associated with a decrease in nocturnal BP and serum noradrenaline levels, as well as a normalization of the 24-h BP profile.


Asunto(s)
Presión de las Vías Aéreas Positiva Contínua/métodos , Endotelio Vascular/fisiopatología , Hipertensión/complicaciones , Apnea Obstructiva del Sueño/terapia , Adulto , Presión Arterial , Femenino , Humanos , Hipertensión/terapia , Masculino , Persona de Mediana Edad , Apnea Obstructiva del Sueño/complicaciones
SELECCIÓN DE REFERENCIAS