1.
J Ultrasound Med ; 37(4): 1025-1031, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29027696

RESUMEN

A method for computer-aided assessment of blood vessel geometries based on shape-fitting algorithms from metric vision was evaluated. Acoustic images of cross sections of the radial artery and cephalic vein were acquired, and medical practitioners used a computer application to measure the wall thickness and nominal diameter of these blood vessels with a caliper method and the shape-fitting method. The methods performed equally well for wall thickness measurements. The shape-fitting method was preferable for measuring the diameter, since it reduced systematic errors by up to 63% in the case of the cephalic vein because of its eccentricity.


Asunto(s)
Brazo/irrigación sanguínea , Procesamiento de Imagen Asistido por Computador/métodos , Arteria Radial/diagnóstico por imagen , Ultrasonografía/métodos , Adulto , Algoritmos , Brazo/diagnóstico por imagen , Pesos y Medidas Corporales/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Reproducibilidad de los Resultados , Venas/diagnóstico por imagen