1.
Artículo en Inglés | MEDLINE | ID: mdl-38158216

RESUMEN

BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an increasingly important treatment option for patients with severe aortic stenosis. Its best implementation is debated, as few centres with high volumes are associated with better outcomes, while centralisation might lead to an inferior availability of treatment for patients living far away. The aim of this study was to investigate the implementation of TAVI in Sweden with a focus on regional differences in terms of availability, short-term mortality and waiting times. METHODS: All patients undergoing TAVI between 2008 and 2020 from the Swedish Transcatheter Cardiac Intervention Registry (SWENTRY) were included. SWENTRY was linked to the National Cause of Death Registry and to publicly available geospatial data from Statistics Sweden. RESULTS: A total of 7280 patients were included. Over time, TAVI interventions increased markedly, while surgical aortic valve replacement (SAVR) remained constant. There were no statistically significant regional differences in incidence between counties with or without a local TAVI centre (p = 0.7) and no clustering tendencies around regions with a local TAVI centre (p = 0.99). Thirty-day mortality improved over time without evidence of regional differences. No regional differences in waiting time from decision to intervention were found for TAVI centre regions and non-TAVI centre regions (p = 0.7). CONCLUSION: This nationwide study indicated no regional differences in terms of availability, short-term mortality or waiting times. An organisation with a few specialised centres was found to be sufficient to provide national coverage of TAVI interventions.

3.
Cardiovasc Revasc Med ; 56: 9-15, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37331886

RESUMEN

BACKGROUND: Early and late readmissions after Transcatheter Aortic Valve Replacement (TAVR) are common and associated with worse outcome. A risk prediction model (TAVR-30) was recently developed using readily available clinical variables to identify patients at risk for hospital readmission within 30 days after TAVR. We performed an independent external validation of the TAVR-30 model. METHODS: The Swedish TAVR-registry, linked together with other mandatory national registries was used to identify all TAVR procedures, variables from the original model, hospitalizations and deaths between the years 2008 to 2021. RESULTS: A total of 8459 patients underwent TAVR, 7693 patients had complete data and were included in the analysis. Out of these, 928 patients experienced a readmission within 30 days. Using the estimates from the original model, a concordance (c)-index of 0.51, a calibration slope of 0.07 and intercept of -0.62 were obtained respectively, overall implying poor model performance. CONCLUSIONS: This independent external validation indicates poor performance of the TAVR-30 model in a Swedish setting. Further research is needed to develop more reliable tools for predicting the risk of early hospital readmission after TAVR, as well as, for providing a deeper understanding of how to develop risk models that performs well in patients with multiple underlying comorbidities.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Readmisión del Paciente , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/etiología , Factores de Riesgo , Comorbilidad , Resultado del Tratamiento , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía
4.
Eur Heart J Qual Care Clin Outcomes ; 8(2): 150-160, 2022 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-33831187

RESUMEN

AIMS: The aim of this study was to investigate the pattern, causes, and predictors of all new hospitalizations in patients who underwent transcatheter aortic valve implantation (TAVI). METHODS AND RESULTS: The nationwide Swedish TAVI registry was merged with other mandatory healthcare registries, which enabled the analysis of all TAVI procedures, new hospital admissions, and death between the years 2008 and 2017. A total of 2821 patients underwent TAVI with a mean of 2.5 hospitalizations during a mean follow-up of 2.2 years. Hospitalizations were associated with worse prognosis. Heart failure (HF) was the most common cause of hospitalization with 19% having at least one hospitalization due to HF causing, 16% of all-cause admissions, and 50% of cardiovascular admissions. Male gender, age >90 years, high Charlson Comorbidity Index, atrial fibrillation, present neurologic disease, severe renal impairment, peripheral vascular disease, New York Heart Association class IV, mild or moderate mean aortic valve gradients, and pulmonary hypertension were associated with an increased risk for all-cause hospitalizations or death. For cardiovascular hospitalization or death, the pattern was similar, with the addition of impaired systolic left ventricular function as a predictor. CONCLUSION: Multiple hospitalizations after TAVI are common and are often caused by HF. Reducing the rate of HF hospitalizations is important to mitigate the burden on the healthcare system due to new hospitalizations after TAVI.


Asunto(s)
Estenosis de la Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Anciano de 80 o más Años , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Femenino , Hospitalización , Humanos , Masculino , Pronóstico , Factores de Riesgo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
5.
Lakartidningen ; 1182021 03 26.
Artículo en Sueco | MEDLINE | ID: mdl-33778936

RESUMEN

This case report covers a patient presenting unconscious to the emergency department with a serum glucose level of 125.6 mmol/L and an associated hyperglycemia-induced hyponatremia with a sodium level of 101 mmol/L. The glucose level is, to our knowledge, one of the most extreme values described in medical literature. Glucose and sodium levels were normalized following treatment with intravenous fluids, mainly Ringer's lactate solution and insulin infusion with an initial rate of 0,5 IU/kg/h. The patient needed ten days of hospital care, including five days at the intensive care unit. Shortly after discharge the patient had a complete recovery. However, the extreme values led to difficulties regarding correction rates, choice of treatment and monitoring, which is further discussed in the article.


Asunto(s)
Diabetes Mellitus Tipo 2 , Hiperglucemia , Coma Hiperglucémico Hiperosmolar no Cetósico , Hiponatremia , Diabetes Mellitus Tipo 2/complicaciones , Diabetes Mellitus Tipo 2/tratamiento farmacológico , Humanos , Hiperglucemia/complicaciones , Hiperglucemia/tratamiento farmacológico , Coma Hiperglucémico Hiperosmolar no Cetósico/complicaciones , Coma Hiperglucémico Hiperosmolar no Cetósico/diagnóstico , Coma Hiperglucémico Hiperosmolar no Cetósico/terapia , Hiponatremia/etiología , Hiponatremia/terapia , Insulina/uso terapéutico