Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
1.
J Cardiol Cases ; 29(3): 128-131, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38481639

RESUMEN

Although debulking devices are very useful in modifying calcified plaques, their effectiveness is highly dependent on wire bias. In particular, in eccentric calcified bifurcation lesions, wire bias tends to be poor and needs to be corrected for adequate lesion preparation. A 67-year-old man was diagnosed with exertional angina pectoris. Coronary angiography showed a highly calcified eccentric lesion from the left main trunk to the left anterior descending artery. The patient refused coronary artery bypass surgery, therefore we decided to treat this complex bifurcation lesion with percutaneous coronary intervention. Initially, we performed reverse orbital atherectomy (OA) and sifted the guide wire position into the calcified plaque successfully. We continued with rotational atherectomy (RA) using a 2.0 mm burr and were able to obtain sufficient lumen without complications. Finally, the lesion was dilated with a cutting balloon and a drug-coated balloon to obtain a stent-like result. This case demonstrates that wire bias modification with reverse OA enables us to perform more aggressive and effective RA safely in eccentric calcified bifurcation lesions. This combination atherectomy can become an attractive approach in eccentric calcified bifurcation lesions. Learning objective: Atherectomy devices are helpful for lesion modification in calcified lesions but their effectiveness is highly dependent on wire bias. If the wire bias can be intentionally moved to an optimal position, it can be a very effective procedure in the treatment of calcified lesions. Wire bias modification by reverse ablation with orbital atherectomy that we have demonstrated enables subsequent aggressive rotational atherectomy and this combination atherectomy can be an attractive approach in eccentric calcified lesions.

2.
Catheter Cardiovasc Interv ; 102(4): 594-607, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37545171

RESUMEN

BACKGROUND: New-generation drug-eluting stents (DES) achieved technological innovations and reported clinical advantages as compared with first-generation DES in clinical trials with 3-5 years follow-up. However, detailed clinical outcome data in very long-term follow-up is still scarce. OBJECTIVES: To evaluate 10-year clinical outcomes after first- and new-generation DES implantation. METHODS: In this extende follow-up study of the RESET, which is a largest randomized trial comparing everolimus-eluting stent (EES) with Sirolimus-eluting stent (SES), the study population consisted of 2892 patients from 84 centers. The primary efficacy and safety endpoints were target lesion revascularization (TLR) and a composite of death or myocardial infarction (MI), respectively. Complete 10-year follow-up was achieved in 87.9% of patients. RESULTS: Cumulative 10-year incidences of TLR and non-TLR were not significantly different between EES and SES (13.9% vs. 15.7%, Log-rank p = 0.20, and 33.4% vs. 31.3%, Log-rank p = 0.30). The cumulative 10-year incidence of death/MI was also not significantly different between the groups (32.5% vs. 34.4%, Log-rank p = 0.18). Cumulative 10-year incidence of definite stent thrombosis was numerically lower in EES than in SES (1.0% vs. 1.7%, Log-rank p = 0.16). The lower risk of EES relative to SES was significant for a composite endpoint of target lesion failure (TLF: 19.6% vs. 24.9%, Log-rank p = 0.001) and target vessel failure (TVF: 26.7% vs. 31.4%, Log-rank p = 0.006). CONCLUSION: During 10-year of follow-up, the risks for primary efficacy and safety endpoints were not significantly different between new-generation EES and first-generation SES, although EES compared with SES was associated with a lower risk for composite endpoints such as TLF and TVF.

3.
EuroIntervention ; 19(5): e402-e413, 2023 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-37395475

RESUMEN

BACKGROUND: There are no randomised trials reporting clinical outcomes of biodegradable polymer biolimus-eluting stents (BP-BES) and durable polymer everolimus-eluting stents (DP-EES) at 10 years. AIMS: We aimed to compare the 10-year clinical outcomes between BP-BES and DP-EES. METHODS: The randomised NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-eluting Stent Trial (NEXT) was originally designed to evaluate the non-inferiority of BP-BES relative to DP-EES with the primary efficacy endpoint of target lesion revascularisation (TLR) at 1 year and the primary safety endpoint of death or myocardial infarction (MI) at 3 years. In this extended follow-up study, clinical outcomes were compared from 1 year after stent implantation up to 10 years between patients with BP-BES and DP-EES. RESULTS: From May to October 2011, NEXT enrolled a total of 3,241 patients from 98 centres in Japan. The current study population consisted of 2,417 patients (1,204 patients with BP-BES and 1,213 with DP-EES) from 66 centres that agreed to participate in the extended study. Complete 10-year follow-up was achieved in 87.5% of patients. The cumulative 10-year incidence of death or MI was 34.0% in the BP-BES group and 33.1% in the DP-EES group (hazard ratio [HR] 1.04, 95% confidence interval [CI]: 0.90-1.20; p=0.58). TLR occurred in 15.9% of patients in the BP-BES group and in 14.1% of the DP-EES group (HR 1.12, 95% CI: 0.90-1.40; p=0.32). In a landmark analysis at 1 year, the cumulative incidences of death or MI and TLR were not significantly different between the 2 groups. CONCLUSIONS: The safety and efficacy outcomes for BP-BES were not significantly different from those for DP-EES at 1 year and up to 10 years after stent implantation.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Infarto del Miocardio , Intervención Coronaria Percutánea , Humanos , Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/complicaciones , Stents Liberadores de Fármacos/efectos adversos , Everolimus/uso terapéutico , Estudios de Seguimiento , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea/efectos adversos , Polímeros , Sirolimus/uso terapéutico , Resultado del Tratamiento
4.
J Atheroscler Thromb ; 27(1): 13-24, 2020 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-31092743

RESUMEN

AIM: Although high on-treatment platelet reactivity (HTPR) with dual antiplatelet therapy (DAPT) correlates with long-term adverse outcomes in patients undergoing percutaneous coronary intervention, the correlation in Japanese patients remains unclear. Therefore, we examined the relationship between platelet reactivity during DAPT with aspirin and clopidogrel and 1-year clinical outcomes following successful coronary stent implantation. METHODS: A prospective, multicenter registry study (j-CHIPS) was conducted in patients undergoing coronary stenting and receiving aspirin and clopidogrel at 16 hospitals in Japan. A VerifyNow point-of-care assay was used to assess platelet reactivity, and a cutoff value to define HTPR was established. RESULTS: Between February 2011 and May 2013, 1047 patients were prospectively enrolled, of which 854 patients with platelet function evaluation at 12-24 h after PCI were included in the final analysis. After 1 year of follow-up, the incidence of the primary endpoint (a composite of all-cause mortality, myocardial infarction, stent thrombosis, and ischemic stroke) was significantly higher in patients with HTPR than in those without (5.9% vs. 1.5%, p=0.008), and HTPR showed a modest ability to discriminate between patients who did and did not experience major adverse cardiac and cerebrovascular events (area under the curve, 0.60; 95% confidence interval, 0.511-0.688, p=0.039). HTPR status did not identify patients at risk for major or minor bleeding events. CONCLUSION: HTPR was significantly associated with adverse ischemic outcomes at 1 year after PCI in Japanese patients receiving maintenance DAPT, indicating its potential as a prognostic indicator of clinical outcomes in this high-risk patient population.


Asunto(s)
Aspirina/administración & dosificación , Clopidogrel/administración & dosificación , Enfermedad de la Arteria Coronaria/cirugía , Intervención Coronaria Percutánea/efectos adversos , Inhibidores de Agregación Plaquetaria/efectos adversos , Stents/efectos adversos , Anciano , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Infarto del Miocardio , Pruebas de Función Plaquetaria , Accidente Cerebrovascular
5.
JACC Cardiovasc Interv ; 12(7): 637-647, 2019 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-30947938

RESUMEN

OBJECTIVES: The aim of this study was to compare 7-year outcomes between the first-generation sirolimus-eluting stent (SES) and the new-generation everolimus-eluting stent (EES) in a randomized clinical trial. BACKGROUND: There is a scarcity of very long-term (beyond 5 years) data from clinical trials investigating whether new-generation drug-eluting stents have clear clinical advantages over first-generation drug-eluting stents. METHODS: RESET (Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial) is the largest randomized trial comparing EES with SES (NCT01035450). Among a total of 3,197 patients in the original RESET population from 100 centers, the present extended 7-year follow-up study was conducted in 2,667 patients from 75 centers after excluding those patients enrolled from centers that denied participation. Complete 7-year follow-up was achieved in 91.5% of patients. RESULTS: The cumulative 7-year incidence of the primary efficacy endpoint of target lesion revascularization was not significantly different between EES and SES (10.2% vs. 11.7%; hazard ratio: 0.87; 95% confidence interval: 0.68 to 1.10; p = 0.24). The risk for the primary safety endpoint of death or myocardial infarction trended lower with EES than with SES (20.6% vs. 23.6%; hazard ratio: 0.85; 95% confidence interval: 0.72 to 1.005; p = 0.06). The cumulative 7-year incidence of definite stent thrombosis was very low and similar between EES and SES (0.9% vs. 1.0%; p = 0.82). The lower risk of EES relative to SES was significant for the composite secondary endpoint of target lesion failure (13.3% vs. 18.1%; hazard ratio: 0.72; 95% confidence interval: 0.59 to 0.88; p = 0.001). CONCLUSIONS: During 7 years of follow-up, the risk for target lesion revascularization was not significantly different between the new-generation EES and the first-generation SES.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Everolimus/administración & dosificación , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Fármacos Cardiovasculares/efectos adversos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Everolimus/efectos adversos , Femenino , Humanos , Japón , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Diseño de Prótesis , Sirolimus/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
6.
Cardiovasc Interv Ther ; 34(1): 47-58, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29508236

RESUMEN

It is unknown whether there is a threshold of creatine kinase (CK) or CK-MB affecting the subsequent mortality for post-discharge myocardial infarction (PDMI) after percutaneous coronary intervention. Current study sought to evaluate the impact of PDMI. The study population included 30,051 patients with successful coronary stenting and discharged alive in the pooled patient-level database of 4 Japanese studies (j-Cypher registry, CREDO-Kyoto PCI/CABG registry cohort-2, RESET, and NEXT). During 4.4 ± 1.4 year follow-up, 915 patients experienced PDMI (cumulative 5-year incidence of 3.6%). Among 466 patients with available peak CK ratio (peak CK/upper limit of normal), peak CK ratio (< 3) was present in 21% of patients, while peak CK ratios (≥ 3 and < 5), (≥ 5 and < 10), (≥ 10 and < 30), and (≥ 30) were present in 17, 25, 30, and 7.3% of patients, respectively. The excess mortality risk of patients with relative to those without PDMI for subsequent mortality was significant (adjusted HR 5.12, 95% CI 4.52-5.80, P < 0.001) by the Cox model with PDMI incorporated as the time-updated covariate. However, the mortality risk of patients in the smallest peak CK ratio category (< 3) was insignificant (HR 0.85, 95% CI 0.43-1.71, P = 0.65). In conclusion, despite significant overall mortality risk of PDMI, the mortality risk of small PDMI was similar to that of no PDMI, suggesting the presence of some threshold about infarct size influencing mortality.Trial registrations The Randomized Evaluation of Sirolimus-Eluting Versus Everolimus-Eluting Stent Trial (RESET); NCT01035450 and NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial (NEXT); NCT01303640. J-Cypher and CREDO-Kyoto PCI/CABG registry cohort 2 were not registered into clinical trial database.


Asunto(s)
Stents Liberadores de Fármacos/efectos adversos , Infarto del Miocardio/mortalidad , Intervención Coronaria Percutánea/efectos adversos , Anciano , Creatina Quinasa/análisis , Femenino , Humanos , Incidencia , Japón , Masculino , Persona de Mediana Edad , Infarto del Miocardio/cirugía , Alta del Paciente/estadística & datos numéricos , Sistema de Registros , Medición de Riesgo/métodos , Factores de Riesgo , Análisis de Supervivencia , Resultado del Tratamiento
9.
Int J Cardiol ; 227: 94-99, 2017 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-27855293

RESUMEN

BACKGROUND: Although several new techniques have been introduced for CTO such as the retrograde approach, the fundamental question of what type of guidewire is the most appropriate as a primary guidewire in the antegrade approach has not been answered. METHODS: The G-FORCE study was designed as a prospective multicenter randomized controlled trial to determine the efficient primary guidewire in antegrade approach for chronic total occlusion (CTO). The first guidewire was randomly assigned to a regular size distal tip group (0.014in. size) or tapered tip group (0.010in. or less). The primary endpoint was defined as successful lesion penetration by the first guidewire into distal true lumen. This study was registered at ClinicalTrials.gov with identifier NCT00987610. RESULTS: A total of 260 patients were enrolled, with an average age of 66±11years and 16% were female. The average J-CTO score was 1.8±1.1. The primary endpoint was achieved in 38% and 32% of patients using tapered and regular distal tip guidewires, respectively (P=0.80). The final PCI success rate was 81% vs. 85%, respectively (P=0.57). Easy CTO lesions with a J-CTO score=0 exhibited a primary endpoint significantly different between tapered and regular distal tip primary guidewires (79% vs. 40%; P=0.046). Guidewire distal coating or distal tip load did not relate with primary guidewire success rate. CONCLUSION: Tapered and regular distal tip guidewires are equivalent as a first choice for CTO. Tapered guidewires are superior for CTO lesions with a J-CTO score=0.


Asunto(s)
Oclusión Coronaria/diagnóstico , Oclusión Coronaria/cirugía , Diseño de Equipo/instrumentación , Intervención Coronaria Percutánea/instrumentación , Anciano , Enfermedad Crónica , Oclusión Coronaria/mortalidad , Diseño de Equipo/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Mortalidad/tendencias , Intervención Coronaria Percutánea/métodos , Intervención Coronaria Percutánea/mortalidad , Estudios Prospectivos , Resultado del Tratamiento
10.
Circ Cardiovasc Interv ; 8(10)2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26446596

RESUMEN

BACKGROUND: There is a paucity of data reporting the clinical outcomes of biodegradable polymer biolimus-eluting stent (BP-BES) compared with durable polymer everolimus-eluting stent (DP-EES) beyond 1 year after stent implantation when the polymer is fully degraded. METHODS AND RESULTS: The NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial (NEXT) is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BP-BES with DP-EES in patients scheduled for percutaneous coronary intervention using drug-eluting stent (DES) without any exclusion criteria among 98 participating centers in Japan. The trial was designed to evaluate noninferiority of BP-BES relative to DP-EES in terms of any target-lesion revascularization at 1 year and death or myocardial infarction at 3 years. Between May and October 2011, 3235 patients were randomly assigned to receive either BP-BES (1617 patients) or DP-EES (1618 patients). Complete 3-year follow-up was achieved in 97.6% of patients. At 3 years, the primary safety end point of death or myocardial infarction occurred in 159 patients (9.9%) in the BP-BES group and in 166 patients (10.3%) in the DP-EES group, demonstrating noninferiority of BP-BES relative to DP-EES (P noninferiority<0.0001 and P superiority=0.7). Cumulative incidence of target-lesion revascularization was not significantly different between the 2 groups (7.4% versus 7.1%; P=0.8). By a landmark analysis at 1 year, the cumulative incidences of death or myocardial infarction and target-lesion revascularization were also not significantly different between the 2 groups (4.6% versus 5.2%; P=0.46 and 3.3% versus 2.7%; P=0.39, respectively). CONCLUSIONS: Safety and efficacy outcomes of BP-BES were non inferior to those of DP-EES 3 years after stent implantation. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01303640.


Asunto(s)
Implantación de Prótesis Vascular , Stents Liberadores de Fármacos/estadística & datos numéricos , Everolimus/administración & dosificación , Infarto del Miocardio/etiología , Intervención Coronaria Percutánea , Complicaciones Posoperatorias , Sirolimus/análogos & derivados , Implantes Absorbibles/estadística & datos numéricos , Anciano , Femenino , Estudios de Seguimiento , Humanos , Japón , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Complicaciones Posoperatorias/mortalidad , Estudios Prospectivos , Sirolimus/administración & dosificación , Análisis de Supervivencia , Resultado del Tratamiento
11.
Int J Cardiol ; 199: 296-301, 2015 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-26226333

RESUMEN

BACKGROUND: The influence of antiplatelet therapy discontinuation on the incidence of stent thrombosis, especially very late stent thrombosis, after drug-eluting stent implantation has not been yet fully addressed. METHODS: Relationship between antiplatelet therapy discontinuation and stent thrombosis up to 5years was evaluated in 12,812 consecutive patients undergoing sirolimus-eluting stents (SES) implantation in the j-Cypher registry. Data on status of antiplatelet therapy during follow-up were collected prospectively. RESULTS: Median follow-up interval was 1699days (interquartile range, 1184-1928days). Incidences of definite stent thrombosis were 0.34% at 30days, 0.55% at 1year, and 1.6% at 5years. Dual antiplatelet therapy was maintained in 97.4%, 63%, and 43.9% of patients at 30days, 1year, and 5years, respectively. The rates of stent thrombosis in patients who discontinued both thienopyridine and aspirin were significantly higher in the time intervals of 31-365days, 2-3years and 3-4years, and tended to be higher in the time intervals of 1-2years and 4-5years than those in patients who continued both (31-365days: 1.26% versus 0.2%, P<0.001; 1-2years: 0.59% versus 0.15%, P=0.06; 2-3years: 1.35% versus 0.2%, P=0.004; 3-4years: 1.09% versus 0.25%, P=0.0496; 4-5years: 1.35% versus 0.43%, P=0.17). Patients who discontinued either thienopyridine or aspirin only did not have an excess of stent thrombosis in any time intervals. CONCLUSIONS: In conclusion, discontinuation of both thienopyridine and aspirin, but not discontinuation of thienopyridine or aspirin only, was associated with an increased incidence of late and very late stent thrombosis up to 5years after SES implantation.


Asunto(s)
Trombosis Coronaria/etiología , Stents Liberadores de Fármacos , Oclusión de Injerto Vascular/etiología , Inhibidores de Agregación Plaquetaria/uso terapéutico , Sistema de Registros , Sirolimus/farmacología , Privación de Tratamiento , Anciano , Trombosis Coronaria/epidemiología , Femenino , Estudios de Seguimiento , Oclusión de Injerto Vascular/epidemiología , Humanos , Inmunosupresores/farmacología , Incidencia , Japón/epidemiología , Masculino , Estudios Prospectivos , Factores de Riesgo , Factores de Tiempo
12.
Cardiovasc Interv Ther ; 30(1): 72-7, 2015 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-24566833

RESUMEN

Although percutaneous transluminal septal myocardial ablation (PTSMA) has been the established treatment of symptomatic patients with hypertrophic obstructive cardiomyopathy (HOCM), the efficacy for specific HOCM is not elucidated. We report a successful case of PTSMA for heart failure with severe left ventricular outflow tract (LVOT) obstruction due to sigmoid-shaped interventricular septum and diffuse left ventricular hypertrophy with Mönckeberg's arteriosclerosis and aortic valvular stenosis. While the PTSMA relieved LVOT obstruction and symptoms in the acute phase, the modest recurrence was confirmed 6 months later, which is rare in the case of idiopathic HOCM. The possible mechanisms of LVOT obstruction and recurrence are discussed.


Asunto(s)
Técnicas de Ablación/métodos , Estenosis de la Válvula Aórtica/cirugía , Cardiomiopatía Hipertrófica/complicaciones , Insuficiencia Cardíaca/cirugía , Esclerosis Calcificante de la Media de Monckeberg/complicaciones , Obstrucción del Flujo Ventricular Externo/complicaciones , Cardiomiopatía Hipertrófica/cirugía , Angiografía Coronaria , Ecocardiografía , Femenino , Insuficiencia Cardíaca/etiología , Humanos , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Obstrucción del Flujo Ventricular Externo/cirugía
13.
JACC Cardiovasc Interv ; 6(7): 654-63, 2013 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-23866178

RESUMEN

OBJECTIVES: This study assessed 5-year outcomes after implantation of sirolimus-eluting stents (SES) for unprotected left main coronary artery (ULMCA) disease in comparison with that for non-left main disease. BACKGROUND: More information on long-term outcomes after ULMCA stenting is needed. METHODS: The j-Cypher is a multicenter prospective registry of consecutive patients undergoing SES implantation in Japan. RESULTS: Among 12,812 patients enrolled in the j-Cypher registry, the unadjusted mortality rate at 5 years was significantly higher in patients with ULMCA stenting than in patients without ULMCA stenting (22.8% vs. 14.1%; p < 0.0001); however, the risk for death with ULMCA stenting was no longer significant after adjusting for confounders (hazard ratio: 1.18, 95% confidence interval: 0.95 to 1.46; p = 0.14). In the lesion-level comparison, the nonbifurcation ULMCA lesions treated exclusively with SES had a significantly lower rate of target lesion revascularization (TLR) than those in non-ULMCA nonbifurcation lesions (2.4% vs. 12.7%; p = 0.04). Among bifurcation lesions, those treated with a provisional 2-stent approach had similar rates of TLR (12.1% vs. 11.4%; p = 0.79) between the ULMCA and non-ULMCA groups. Lesions treated with an elective 2-stent approach had higher TLR rates in the ULMCA group as compared with the non-ULMCA group (33.5% vs. 19.7%; p = 0.002). CONCLUSIONS: The safety of ULMCA stenting relative to non-LMCA stenting was maintained through 5 years follow-up. In terms of efficacy, SES implantation in nonbifurcation ULMCA lesions was associated with an extremely low cumulative incidence of TLR, whereas the elective 2-stent approach for ULMCA bifurcation lesions was associated with a markedly higher cumulative incidence of TLR as compared with that for non-ULMCA bifurcation lesions.


Asunto(s)
Fármacos Cardiovasculares/administración & dosificación , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Intervención Coronaria Percutánea/instrumentación , Sirolimus/administración & dosificación , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/mortalidad , Trombosis Coronaria/etiología , Femenino , Humanos , Japón , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Análisis Multivariante , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/mortalidad , Modelos de Riesgos Proporcionales , Estudios Prospectivos , Diseño de Prótesis , Sistema de Registros , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
14.
J Am Coll Cardiol ; 62(3): 181-190, 2013 Jul 16.
Artículo en Inglés | MEDLINE | ID: mdl-23684673

RESUMEN

OBJECTIVES: NEXT (NOBORI Biolimus-Eluting Versus XIENCE/PROMUS Everolimus-Eluting Stent Trial) was designed for evaluating the noninferiority of a biolimus-eluting stent (BES) relative to an everolimus-eluting stent (EES) in terms of target lesion revascularization (TLR) at 1 year. BACKGROUND: Efficacy and safety data comparing biodegradable polymer BES with durable polymer cobalt-chromium EES are currently limited. METHODS: The NEXT trial is a prospective, multicenter, randomized, open-label, noninferiority trial comparing BES with EES. Between May and October 2011, 3,235 patients were randomly assigned to receive either BES (n = 1,617) or EES (n = 1,618). RESULTS: At 1 year, the primary efficacy endpoint of TLR occurred in 67 patients (4.2%) in the BES group, and in 66 patients (4.2%) in the EES group, demonstrating noninferiority of BES relative to EES (p for noninferiority <0.0001, and p for superiority = 0.93). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.25% vs. 0.06%, p = 0.18). An angiographic substudy enrolling 528 patients (BES: n = 263, and EES: n = 265) demonstrated noninferiority of BES relative to EES regarding the primary angiographic endpoint of in-segment late loss (0.03 ± 0.39 mm vs. 0.06 ± 0.45 mm, p for noninferiority <0.0001, and p for superiority = 0.52) at 266 ± 43 days after stent implantation. CONCLUSIONS: One-year clinical and angiographic outcome after BES implantation was noninferior to and not different from that after EES implantation in a mostly stable coronary artery disease population. One-year clinical outcome after both BES and EES use was excellent, with a low rate of TLR and extremely low rate of stent thrombosis.


Asunto(s)
Implantes Absorbibles , Enfermedad de la Arteria Coronaria/cirugía , Stents Liberadores de Fármacos , Polímeros/administración & dosificación , Sirolimus/análogos & derivados , Implantes Absorbibles/normas , Anciano , Anciano de 80 o más Años , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Stents Liberadores de Fármacos/normas , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Radiografía , Método Simple Ciego , Sirolimus/administración & dosificación , Resultado del Tratamiento
15.
Am J Cardiol ; 110(9): 1282-9, 2012 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-22835413

RESUMEN

The aim of this study was to evaluate the 5-year clinical outcomes of patients who underwent sirolimus-eluting stent implantation for chronic total occlusion (CTO). Among 10,759 patients treated exclusively with sirolimus-eluting stent in the j-Cypher registry, clinical outcomes were compared between 1,210 patients with revascularization for CTO and 9,549 patients with revascularization for non-CTO only. The cumulative 5-year incidence of all-cause death (13.2% vs 14.3%, p = 0.56) and definite stent thrombosis (1.9% vs 1.6%, p = 0.76) was similar between the 2 groups. The adjusted risk for CTO relative to non-CTO for all-cause death and definite stent thrombosis was insignificant (hazard ratio [HR] 0.97, 95% confidence interval [CI] 0.81 to 1.16, and HR 0.99, 95% CI 0.6 to 1.65, respectively). The cumulative incidence of target lesion revascularization was significantly higher in the CTO group (20.7% vs 14.8%, p <0.001). The adjusted risk for target lesion revascularization was significant (HR 1.31, 95% CI 1.13 to 1.52, p <0.001). In the subgroup analysis, the risk for CTO for all-cause death tended to be lower in the subgroup of patients with left ventricular ejection fractions ≤40% (HR 0.68, 95% CI 0.45 to 1.01, p = 0.053), while the risk was significantly higher in the subgroup of patients with end-stage renal disease without hemodialysis (HR 1.66, 95% CI 1.02 to 2.70, p = 0.04). In conclusion, sirolimus-eluting stent implantation for CTO appears to be as safe as that for non-CTO for up to 5 years, except for the modestly elevated risk for target lesion revascularization and the higher risk for all-cause death in patients with end-stage renal disease without hemodialysis.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Oclusión Coronaria/mortalidad , Oclusión Coronaria/terapia , Reestenosis Coronaria/terapia , Stents Liberadores de Fármacos/estadística & datos numéricos , Sirolimus/administración & dosificación , Anciano , Angioplastia Coronaria con Balón/métodos , Angioplastia Coronaria con Balón/mortalidad , Causas de Muerte , Enfermedad Crónica , Estudios de Cohortes , Intervalos de Confianza , Angiografía Coronaria/métodos , Oclusión Coronaria/diagnóstico por imagen , Reestenosis Coronaria/diagnóstico por imagen , Reestenosis Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Femenino , Mortalidad Hospitalaria/tendencias , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Seguridad del Paciente , Pronóstico , Sistema de Registros , Retratamiento/estadística & datos numéricos , Medición de Riesgo , Índice de Severidad de la Enfermedad , Análisis de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
16.
Circulation ; 126(10): 1225-36, 2012 Sep 04.
Artículo en Inglés | MEDLINE | ID: mdl-22824435

RESUMEN

BACKGROUND: Several recent randomized trials comparing everolimus-eluting stent (EES) and sirolimus-eluting stent (SES) reported similar outcomes. However, only 1 trial was powered for a clinical end point, and no trial was powered for evaluating target-lesion revascularization. METHODS AND RESULTS: Randomized Evaluation of Sirolimus-eluting versus Everolimus-eluting stent Trial is a prospective multicenter randomized open-label trial comparing EES with SES in Japan. The trial was powered for evaluating noninferiority of EES relative to SES in terms of target-lesion revascularization. From February and July 2010, 3197 patients were randomly assigned to receive either EES (1597 patients) or SES (1600 patients). At 1 year, the primary efficacy end point of target-lesion revascularization occurred in 65 patients (4.3%) in the EES group and in 76 patients (5.0%) in the SES group, demonstrating noninferiority of EES to SES (P(noninferiority)<0.0001, and P(superiority)=0.34). Cumulative incidence of definite stent thrombosis was low and similar between the 2 groups (0.32% versus 0.38%, P=0.77). An angiographic substudy enrolling 571 patients (EES, 285 patients and SES, 286 patients) demonstrated noninferiority of EES relative to SES regarding the primary angiographic end point of in-segment late loss (0.06±0.37 mm versus 0.02±0.46 mm, P(noninferiority)<0.0001, and P(superiority)=0.24) at 278±63 days after index stent implantation. CONCLUSIONS: One-year clinical and angiographic outcome after EES implantation was noninferior to and not different from that after SES implantation in a stable coronary artery disease population with relatively less complex coronary anatomy. One-year clinical outcome after both EES and SES use was excellent with a low rate of target-lesion revascularization and a very low rate of stent thrombosis. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01035450.


Asunto(s)
Angioplastia Coronaria con Balón/métodos , Enfermedad de la Arteria Coronaria/terapia , Stents Liberadores de Fármacos , Sirolimus/análogos & derivados , Sirolimus/administración & dosificación , Anciano , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Reestenosis Coronaria/prevención & control , Everolimus , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/administración & dosificación , Japón , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Resultado del Tratamiento
17.
Circulation ; 125(4): 584-91, 2012 Jan 31.
Artículo en Inglés | MEDLINE | ID: mdl-22203694

RESUMEN

BACKGROUND: There is a scarcity of long-term data from large-scale drug-eluting stent registries with a large enough sample to evaluate low-frequency events such as stent thrombosis (ST). METHODS AND RESULTS: Five-year outcomes were evaluated in 12 812 consecutive patients undergoing sirolimus-eluting stent (SES) implantation in the j-Cypher registry. Cumulative incidence of definite ST was low (30 day, 0.3%; 1 year, 0.6%; and 5 years, 1.6%). However, late and very late ST continued to occur without attenuation up to 5 years after sirolimus-eluting stent implantation (0.26%/y). Cumulative incidence of target lesion revascularization within the first year was low (7.3%). However, late target lesion revascularization beyond 1 year also continued to occur without attenuation up to 5 years (2.2%/y). Independent risk factors of ST were completely different according to the timing of ST onset, suggesting the presence of different pathophysiological mechanisms of ST according to the timing of ST onset: acute coronary syndrome and target of proximal left anterior descending coronary artery for early ST; side-branch stenting, diabetes mellitus, and end-stage renal disease with or without hemodialysis for late ST; and current smoking and total stent length >28 mm for very late ST. Independent risk factors of late target lesion revascularization beyond 1 year were generally similar to those risk factors identified for early target lesion revascularization. CONCLUSION: Late adverse events such as very late ST and late target lesion revascularization are continuous hazards, lasting at least up to 5 years after implantation of the first-generation drug-eluting stents (sirolimus-eluting stents), which should be the targets for developing improved coronary stents.


Asunto(s)
Angioplastia de Balón/mortalidad , Reestenosis Coronaria/mortalidad , Trombosis Coronaria/mortalidad , Stents Liberadores de Fármacos/efectos adversos , Sistema de Registros/estadística & datos numéricos , Sirolimus/administración & dosificación , Anciano , Anciano de 80 o más Años , Angioplastia de Balón/métodos , Muerte Súbita Cardíaca/epidemiología , Stents Liberadores de Fármacos/estadística & datos numéricos , Femenino , Estudios de Seguimiento , Humanos , Inmunosupresores/administración & dosificación , Incidencia , Japón/epidemiología , Masculino , Persona de Mediana Edad , Factores de Riesgo , Factores de Tiempo
18.
Circ Cardiovasc Interv ; 4(4): 362-70, 2011 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-21712527

RESUMEN

BACKGROUND: Ostial left anterior descending coronary artery (LAD) lesion has been regarded as a lesion subset unsuitable for coronary stenting. Long-term outcomes of sirolimus-eluting stent (SES) implantation for ostial LAD lesions have not been adequately evaluated. METHODS AND RESULTS: Among 12 824 patients enrolled in the j-Cypher Registry, 3-year outcomes were compared between 481 patients with SES-treated ostial LAD lesions and 5369 patients with SES-treated nonostial proximal LAD lesions. Patients with ostial LAD lesions had similar incidences of target lesion revascularization (TLR) as those with nonostial proximal LAD lesions (9.4% versus 9.7%; P=0.98; adjusted hazard ratio [HR], 0.99; 95% CI, 0.7 to 1.36; P=0.94) and death/myocardial infarction (MI) (10.7% versus 11.4%; P=0.82; adjusted HR, 1.05; 95% CI, 0.76 to 1.4; P=0.77). Among the patients with ostial LAD lesions, those undergoing both main and side branch stenting (n=62) compared to main branch stenting alone (n=419) had a higher risk for TLR (adjusted HR, 4.65; 95% CI, 2.32 to 9.25; P<0.0001) but similar risk for death/MI (adjusted HR, 1.15; 95% CI, 0.49 to 2.41; P=0.73). In patients with main branch stenting alone, outcomes after crossover stenting across the circumflex coronary artery (n=225) were not different from those after ostial stenting (n=194) for TLR (adjusted HR, 0.77; 95% CI, 0.33 to 1.82; P=0.55) and for death/MI (adjusted HR, 1.54; 95% CI, 0.78 to 3.2; P=0.22). CONCLUSIONS: In terms of both safety and efficacy, 3-year outcomes of percutaneous coronary intervention using SES for ostial LAD lesions were comparable to those for nonostial proximal LAD lesions. Crossover stenting with a 1-stent approach might be a reasonable option in treating ostial LAD lesions.


Asunto(s)
Implantación de Prótesis Vascular , Vasos Coronarios/cirugía , Stents Liberadores de Fármacos/estadística & datos numéricos , Infarto del Miocardio/terapia , Sirolimus/administración & dosificación , Anciano , Anciano de 80 o más Años , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/mortalidad , Infarto del Miocardio/patología , Infarto del Miocardio/fisiopatología , Recurrencia , Sistema de Registros , Riesgo , Análisis de Supervivencia , Resultado del Tratamiento
19.
Am J Cardiol ; 107(8): 1155-62, 2011 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-21296326

RESUMEN

The purpose of the present study was to evaluate the 3-year clinical outcomes after percutaneous coronary intervention with sirolimus-eluting stents in patients with insulin-treated diabetes mellitus (DM-insulin) and those with non-insulin-treated DM (DM-non-insulin) compared to patients without DM. Of 10,778 consecutive patients treated exclusively with sirolimus-eluting stents in the j-Cypher registry, we identified 996 patients with DM-insulin, 3,404 with DM-non-insulin, and 6,378 without DM. Compared to the non-DM group, the adjusted risk of a serious cardiovascular event (composite of all-cause death, myocardial infarction, and stroke) was significantly greater in the DM-insulin group (hazard ratio 1.12, 95% confidence interval [CI] 1.03 to 1.23; p = 0.01), but not in the DM-non-insulin group (hazard ratio 1.02, 95% CI 0.96 to 1.09; p = 0.47). The adjusted risk of target lesion revascularization was significantly greater in both the DM-insulin group (odds ratio 1.52, 95% CI 1.19 to 1.92; p = 0.0006) and the DM-non-insulin group (odds ratio 1.24, 95% CI 1.05 to 1.45; p = 0.009). In conclusion, a diabetes-associated excess risk of target lesion revascularization was found, regardless of insulin use in this large, real-world study of Japanese patients with sirolimus-eluting stent implantation. However, regarding serious cardiovascular events, an excess risk was seen only in the DM-insulin group. The risk of serious cardiovascular events was similar between the DM-non-insulin and non-DM groups.


Asunto(s)
Angioplastia Coronaria con Balón/instrumentación , Diabetes Mellitus/tratamiento farmacológico , Stents Liberadores de Fármacos , Insulina/uso terapéutico , Isquemia Miocárdica/terapia , Sistema de Registros , Sirolimus/farmacología , Anciano , Femenino , Estudios de Seguimiento , Humanos , Hipoglucemiantes/uso terapéutico , Inmunosupresores/farmacología , Masculino , Isquemia Miocárdica/complicaciones , Estudios Prospectivos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...