Physiol Meas ; 44(11)2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-37494945

RESUMEN

Photoplethysmography is a key sensing technology which is used in wearable devices such as smartwatches and fitness trackers. Currently, photoplethysmography sensors are used to monitor physiological parameters including heart rate and heart rhythm, and to track activities like sleep and exercise. Yet, wearable photoplethysmography has potential to provide much more information on health and wellbeing, which could inform clinical decision making. This Roadmap outlines directions for research and development to realise the full potential of wearable photoplethysmography. Experts discuss key topics within the areas of sensor design, signal processing, clinical applications, and research directions. Their perspectives provide valuable guidance to researchers developing wearable photoplethysmography technology.


Asunto(s)
Fotopletismografía , Dispositivos Electrónicos Vestibles , Monitores de Ejercicio , Procesamiento de Señales Asistido por Computador , Frecuencia Cardíaca/fisiología
2.
Sensors (Basel) ; 23(3)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-36772474

RESUMEN

On average, arterial oxygen saturation measured by pulse oximetry (SpO2) is higher in hypoxemia than the true oxygen saturation measured invasively (SaO2), thereby increasing the risk of occult hypoxemia. In the current article, measurements of SpO2 on 17 cyanotic newborns were performed by means of a Nellcor pulse oximeter (POx), based on light with two wavelengths in the red and infrared regions (660 and 900 nm), and by means of a novel POx, based on two wavelengths in the infrared region (761 and 820 nm). The SpO2 readings from the two POxs showed higher values than the invasive SaO2 readings, and the disparity increased with decreasing SaO2. SpO2 measured using the two infrared wavelengths showed better correlation with SaO2 than SpO2 measured using the red and infrared wavelengths. After appropriate calibration, the standard deviation of the individual SpO2-SaO2 differences for the two-infrared POx was smaller (3.6%) than that for the red and infrared POx (6.5%, p < 0.05). The overestimation of SpO2 readings in hypoxemia was explained by the increase in hypoxemia of the optical pathlengths-ratio between the two wavelengths. The two-infrared POx can reduce the overestimation of SpO2 measurement in hypoxemia and the consequent risk of occult hypoxemia, owing to its smaller increase in pathlengths-ratio in hypoxemia.


Asunto(s)
Oximetría , Saturación de Oxígeno , Recién Nacido , Humanos , Hipoxia , Oxígeno , Calibración
3.
J Pers Med ; 12(11)2022 Nov 07.
Artículo en Inglés | MEDLINE | ID: mdl-36573720

RESUMEN

Personalized management of diseases by considering relevant patient features enables optimal treatment, instead of management according to an average patient. Precision management of hypertension is important, because both susceptibility to complications and response to treatment vary between individuals. While the use of genomic and proteomic personal features for widespread precision hypertension management is not practical, other features, such as age, ethnicity, and cardiovascular diseases, have been utilized in guidelines for hypertension management. In precision medicine, more blood-pressure-related clinical and physiological characteristics in the patient's profile can be utilized for the determination of the threshold of hypertension and optimal treatment. Several non-invasive and simple-to-use techniques for the measurement of hypertension-related physiological features are suggested for use in precision management of hypertension. In order to provide precise management of hypertension, accurate measurement of blood pressure is required, but the available non-invasive blood pressure measurement techniques, auscultatory sphygmomanometry and oscillometry, have inherent significant inaccuracy-either functional or technological-limiting the precision of personalized management of hypertension. A novel photoplethysmography-based technique for the measurement of systolic blood pressure that was recently found to be more accurate than the two available techniques can be utilized for more precise and personalized hypertension management.

4.
Sensors (Basel) ; 20(17)2020 Aug 27.
Artículo en Inglés | MEDLINE | ID: mdl-32867184

RESUMEN

Adequate oxygen delivery to a tissue depends on sufficient oxygen content in arterial blood and blood flow to the tissue. Oximetry is a technique for the assessment of blood oxygenation by measurements of light transmission through the blood, which is based on the different absorption spectra of oxygenated and deoxygenated hemoglobin. Oxygen saturation in arterial blood provides information on the adequacy of respiration and is routinely measured in clinical settings, utilizing pulse oximetry. Oxygen saturation, in venous blood (SvO2) and in the entire blood in a tissue (StO2), is related to the blood supply to the tissue, and several oximetric techniques have been developed for their assessment. SvO2 can be measured non-invasively in the fingers, making use of modified pulse oximetry, and in the retina, using the modified Beer-Lambert Law. StO2 is measured in peripheral muscle and cerebral tissue by means of various modes of near infrared spectroscopy (NIRS), utilizing the relative transparency of infrared light in muscle and cerebral tissue. The primary problem of oximetry is the discrimination between absorption by hemoglobin and scattering by tissue elements in the attenuation measurement, and the various techniques developed for isolating the absorption effect are presented in the current review, with their limitations.


Asunto(s)
Monitoreo Fisiológico , Oximetría/métodos , Oxígeno/sangre , Humanos , Espectroscopía Infrarroja Corta
6.
Vet Anaesth Analg ; 47(2): 177-182, 2020 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-31982340

RESUMEN

OBJECTIVE: Factors described as contributors to the 'penumbra effect' in relation to pulse oximetry include optical shunting, circulatory anastomoses and probe parallelity. This study aimed to clarify the main underlying mechanism involved. STUDY DESIGN: Prospective clinical trial. ANIMALS: A total of 30 dogs and 15 cats (client-owned). METHODS: In anaesthetized dogs and cats, a pulse oximeter probe was placed on the tongue to measure haemoglobin oxygen saturation (SpO2) and perfusion index. In 15 dogs, the probe was positioned at the root (baseline) of the tongue, then at 0.5 and 1 cm rostral to it, to investigate the effect of circulatory anastomoses on SpO2 values. In cats (which do not have lingual arteriovenous anastomoses), the probe was positioned at the root and apex of the tongue. To assess the effect of probe parallelity on SpO2 values in dogs, two lines were drawn parallel to the planes of the light-emitting diode and the detector surfaces and the intersection angle calculated using ImageMeter Pro, Google Play. In a further 15 dogs, the probe was placed at the tongue edge (0% optical shunt), with 50% optical shunt, then with the 50% optical shunt shielded. Data were analysed using Friedman's test, Student t test and Pearson's correlation coefficient (p < 0.05). RESULTS: In dogs, SpO2 values were significantly higher at 1.0 cm than at baseline (p < 0.0001). In cats, there were no significant differences in SpO2 values at each location. There was no significant difference in SpO2 between 0% and 50% optical shunt in dogs. SpO2 had a moderate negative correlation with tongue thickness and negligible correlation with intersection angle. CONCLUSIONS AND CLINICAL RELEVANCE: Circulatory anastomoses are probably responsible for observed changes in SpO2 as the probe is placed towards an extremity, rather than optical shunting or probe parallelity.


Asunto(s)
Anestesia/veterinaria , Gatos/fisiología , Perros/fisiología , Monitoreo Intraoperatorio/veterinaria , Oximetría/veterinaria , Lengua/irrigación sanguínea , Animales , Monitoreo Intraoperatorio/instrumentación , Monitoreo Intraoperatorio/métodos , Oximetría/instrumentación , Oximetría/métodos
7.
Sensors (Basel) ; 18(10)2018 Oct 15.
Artículo en Inglés | MEDLINE | ID: mdl-30326552

RESUMEN

Oxygen saturation in arterial blood (SaO2) provides information about the performance of the respiratory system. Non-invasive measurement of SaO2 by commercial pulse oximeters (SpO2) make use of photoplethysmographic pulses in the red and infrared regions and utilizes the different spectra of light absorption by oxygenated and de-oxygenated hemoglobin. Because light scattering and optical path-lengths differ between the two wavelengths, commercial pulse oximeters require empirical calibration which is based on SaO2 measurement in extracted arterial blood. They are still prone to error, because the path-lengths difference between the two wavelengths varies among different subjects. We have developed modified pulse oximetry, which makes use of two nearby infrared wavelengths that have relatively similar scattering constants and path-lengths and does not require an invasive calibration step. In measurements performed on adults during breath holding, the two-infrared pulse oximeter and a commercial pulse oximeter showed similar changes in SpO2. The two pulse oximeters showed similar accuracy when compared to SaO2 measurement in extracted arterial blood (the gold standard) performed in intensive care units on newborns and children with an arterial line. Errors in SpO2 because of variability in path-lengths difference between the two wavelengths are expected to be smaller in the two-infrared pulse oximeter.


Asunto(s)
Oximetría/instrumentación , Oximetría/métodos , Adulto , Contencion de la Respiración , Calibración , Diseño de Equipo , Humanos , Recién Nacido , Unidades de Cuidado Intensivo Pediátrico , Masculino , Oxígeno/sangre
8.
J Perinatol ; 38(9): 1220-1226, 2018 09.
Artículo en Inglés | MEDLINE | ID: mdl-29961764

RESUMEN

OBJECTIVE: We aimed to correlate photoplethysmographic parameters with stroke volume in infants with PDA. Photoplethysmography constitutes the optical signal in pulse oximetry. STUDY DESIGN: Stroke volume was determined echocardiographically. Pulse transit time, right hand to foot arrival time difference, and relative amplitude were measured from pulse oximeter and ECG waveforms. Photoplethysmographic parameters before and after PDA closure were compared with stroke volume. RESULTS: After PDA closure, pulse transit time to the hand and to the foot were prolonged (54.7 ± 6.7 vs 65.5 ± 9.8 ms, p < 0.001, 82.5 ± 12.8 vs 88.6 ± 10.6 ms, p = 0.03), arrival time difference decreased (27.7 ± 7.6 vs 23.1 ± 5.6 ms, p = 0.021), and relative amplitude decreased (from 2.1 ± 0.7% to 1.5 ± 0.5%, p = 0.003). The time-based photoplethysmographic parameters correlated with stroke volume. CONCLUSIONS: Photoplethysmographic waveform parameters are significantly different before and after PDA closure and the time-based parameters correlate well with stroke volume. Monitoring pulse transit time may assist in evaluation for spontaneous PDA closure or response to therapy.


Asunto(s)
Conducto Arterioso Permeable/fisiopatología , Pie/fisiología , Mano/fisiología , Fotopletismografía , Ecocardiografía , Femenino , Humanos , Recien Nacido con Peso al Nacer Extremadamente Bajo , Recien Nacido Extremadamente Prematuro , Recién Nacido , Masculino , Estudios Prospectivos , Análisis de la Onda del Pulso , Volumen Sistólico
9.
Physiol Meas ; 39(7): 075006, 2018 07 20.
Artículo en Inglés | MEDLINE | ID: mdl-29943734

RESUMEN

OBJECTIVE: The ductus arteriosus is a blood vessel that connects the pulmonary artery to the descending aorta during fetal life and generally undergoes spontaneous closure shortly after birth. In premature neonates it often fails to close (patent ductus arteriosus-PDA), which can result in diversion of a significant part of the left-ventricular cardiac output to the pulmonary circulation. This left-to-right shunt may result in significant increase of pulmonary blood flow and decrease of systemic perfusion (hemodynamically significant PDA-hsPDA), which may lead to severe neonatal morbidity. The study objective was to find the relationship between hsPDA and perfusion index (PI), a photoplethysmographic parameter related to systemic perfusion. APPROACH: PI measures the relative systolic increase in tissue light absorption due to the systolic increase in the tissue blood volume. PI has been found to be directly related to tissue perfusion and is therefore expected to be affected by hsPDA. MAIN RESULTS: PI was found to be higher in preterm neonates with hsPDA after first week of life, in comparison to those with closed DA, despite the lower systemic perfusion, probably due to reverse flow during diastole. SIGNIFICANCE: In our study, perfusion index increased despite the lower systemic perfusion, indicating that in neonates with hsPDA, perfusion index is not necessarily a measure of perfusion. Nevertheless, PI can be used as a screening tool for suspicious PDA, in order to select a relatively small group of neonates for a more definitive examination by echocardiography, which is not suitable for universal screening.


Asunto(s)
Conducto Arterioso Permeable/fisiopatología , Recien Nacido Prematuro/fisiología , Flujo Sanguíneo Regional , Femenino , Hemodinámica , Humanos , Recién Nacido , Cuidado Intensivo Neonatal , Masculino , Embarazo
10.
Med Devices (Auckl) ; 10: 157-163, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28769596

RESUMEN

The commonly used techniques for systolic blood pressure (SBP) and diastolic blood pressure (DBP) measurement are the auscultatory Korotkoff-based sphygmomanometry and oscillometry. The former technique is relatively accurate but is limited to a physician's office because its automatic variant is subject to noise artifacts. Consequently, the Korotkoff-based measurement overestimates the blood pressure in some patients due to white coat effect, and because it is a single measurement, it cannot properly represent the variable blood pressure. Automatic oscillometry can be used at home by the patient and is preferred even in clinics. However, the technique's accuracy is low and errors of 10-15 mmHg are common. Recently, we have developed an automatic technique for SBP measurement, based on an arm pressure cuff and a finger photoplethysmographic probe. The technique was found to be significantly more accurate than oscillometry, and comparable to the Korotkoff-based technique, the reference-standard for non-invasive blood pressure measurements. The measurement of SBP is a mainstay for the diagnosis and follow-up of hypertension, which is a major risk factor for several adverse events, mainly cardiovascular. Lowering blood pressure evidently reduces the risk, but excessive lowering can result in hypotension and consequently hypoperfusion to vital organs, since blood pressure is the driving force for blood flow. Erroneous measurement by 10 mmHg can lead to a similar unintended reduction of SBP and may adversely affect patients treated to an SBP of 120-130 mmHg. In particular, in elderly patients, unintended excessive reduction of blood pressure due to inaccurate SBP measurement can result in cerebral hypoperfusion and consequent cognitive decline. By using a more accurate technique for automatic SBP measurement (such as the photoplethysmographic-based technique), the optimal blood pressure target can be achieved with lower risk for hypotension and its adverse events.

11.
Opt Lett ; 41(18): 4312-5, 2016 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-27628385

RESUMEN

The value of oxygen saturation in venous blood, SvO2, has important clinical significance since it is related to the tissue oxygen utilization, which is related to the blood flow to the tissue and to its metabolism rate. However, existing pulse oximetry techniques are not suitable for blood in veins. In the current study we examine the feasibility of difference oximetry to assess SvO2 by using two near-infrared wavelengths and collecting the backscattered light from two photodetectors located at different distances from the light source.


Asunto(s)
Oximetría/métodos , Espectroscopía Infrarroja Corta/métodos , Humanos , Luz , Oxígeno/sangre , Venas
13.
Med Devices (Auckl) ; 7: 231-9, 2014.
Artículo en Inglés | MEDLINE | ID: mdl-25031547

RESUMEN

Oxygen saturation in the arterial blood (SaO2) provides information on the adequacy of respiratory function. SaO2 can be assessed noninvasively by pulse oximetry, which is based on photoplethysmographic pulses in two wavelengths, generally in the red and infrared regions. The calibration of the measured photoplethysmographic signals is performed empirically for each type of commercial pulse-oximeter sensor, utilizing in vitro measurement of SaO2 in extracted arterial blood by means of co-oximetry. Due to the discrepancy between the measurement of SaO2 by pulse oximetry and the invasive technique, the former is denoted as SpO2. Manufacturers of pulse oximeters generally claim an accuracy of 2%, evaluated by the standard deviation (SD) of the differences between SpO2 and SaO2, measured simultaneously in healthy subjects. However, an SD of 2% reflects an expected error of 4% (two SDs) or more in 5% of the examinations, which is in accordance with an error of 3%-4%, reported in clinical studies. This level of accuracy is sufficient for the detection of a significant decline in respiratory function in patients, and pulse oximetry has been accepted as a reliable technique for that purpose. The accuracy of SpO2 measurement is insufficient in several situations, such as critically ill patients receiving supplemental oxygen, and can be hazardous if it leads to elevated values of oxygen partial pressure in blood. In particular, preterm newborns are vulnerable to retinopathy of prematurity induced by high oxygen concentration in the blood. The low accuracy of SpO2 measurement in critically ill patients and newborns can be attributed to the empirical calibration process, which is performed on healthy volunteers. Other limitations of pulse oximetry include the presence of dyshemoglobins, which has been addressed by multiwavelength pulse oximetry, as well as low perfusion and motion artifacts that are partially rectified by sophisticated algorithms and also by reflection pulse oximetry.

14.
Sensors (Basel) ; 14(4): 7420-34, 2014 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-24763216

RESUMEN

The assessment of oxygen saturation in arterial blood by pulse oximetry (SpO2) is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and the analysis of photoplethysmographic (PPG) signals acquired at two wavelengths. Commercial pulse oximeters use two wavelengths in the red and infrared regions which have different pathlengths and the relationship between the PPG-derived parameters and oxygen saturation in arterial blood is determined by means of an empirical calibration. This calibration results in an inherent error, and pulse oximetry thus has an error of about 4%, which is too high for some clinical problems. We present calibration-free pulse oximetry for measurement of SpO2, based on PPG pulses of two nearby wavelengths in the infrared. By neglecting the difference between the path-lengths of the two nearby wavelengths, SpO2 can be derived from the PPG parameters with no need for calibration. In the current study we used three laser diodes of wavelengths 780, 785 and 808 nm, with narrow spectral line-width. SaO2 was calculated by using each pair of PPG signals selected from the three wavelengths. In measurements on healthy subjects, SpO2 values, obtained by the 780-808 nm wavelength pair were found to be in the normal range. The measurement of SpO2 by two nearby wavelengths in the infrared with narrow line-width enables the assessment of SpO2 without calibration.


Asunto(s)
Rayos Infrarrojos , Oximetría/métodos , Adulto , Calibración , Hemoglobinas/metabolismo , Humanos , Rayos Láser , Masculino , Presión Parcial , Fotopletismografía , Adulto Joven
15.
Sensors (Basel) ; 13(11): 14797-812, 2013 Oct 31.
Artículo en Inglés | MEDLINE | ID: mdl-24184918

RESUMEN

In the current study, a non-invasive technique for systolic blood pressure (SBP) measurement based on the detection of photoplethysmographic (PPG) pulses during pressure-cuff deflation was compared to sphygmomanometry-the Korotkoff sounds technique. The PPG pulses disappear for cuff-pressures above the SBP value and reappear when the cuff-pressure decreases below the SBP value. One hundred and twenty examinations were performed on forty subjects. In 97 examinations the two methods differed by less than 3 mmHg. In nine examinations the SBP value measured by PPG was higher than that measured by sphygmomanometry by 5 mmHg or more. In only one examination the former was lower by 5 mmHg or more than the latter. The appearance of either the PPG pulses or the Korotkoff sounds assures that the artery under the cuff is open during systolic peak pressure. In the nine examinations mentioned above the PPG pulses were observed while Korotkoff sounds were not detected, despite the open artery during systole. In these examinations, the PPG-based technique was more reliable than sphygmomanometry. The high signal-to-noise ratio of measured PPG pulses indicates that automatic measurement of the SBP by means of automatic detection of the PPG signals is feasible.


Asunto(s)
Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos , Presión Sanguínea/fisiología , Fotopletismografía/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Esfigmomanometros
16.
Med Hypotheses ; 81(2): 293-6, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-23679994

RESUMEN

The oxygen saturation of the systemic arterial blood is associated with the adequacy of respiration, and can be measured non-invasively by pulse oximetry in the systemic tissue. The oxygen saturation of the blood in the pulmonary artery, the mixed venous blood, reflects the balance between oxygen supply to the systemic tissues and their oxygen demand. The mixed venous oxygen saturation has also clinical significance because it is used in Fick equation for the quantitative measurement of cardiac output. At present the measurement of the mixed venous oxygen saturation is invasive and requires insertion of a Swan-Ganz catheter into the pulmonary artery. We suggest a noninvasive method for the measurement of the mixed venous oxygen saturation in infants, pulmonary pulse oximetry. The method is similar to the systemic pulse oximetry, which is based on the different light absorption curves of oxygenated and deoxygenated hemoglobin and on the analysis of photoplethysmographic curves in two wavelengths. The proposed pulmonary pulse oximeter includes light-sources of two wavelengths in the infrared, which illuminate the pulmonary tissue through the thoracic wall. Part of the light which is scattered back from the pulmonary tissue and passes through the thoracic wall is detected, and for each wavelength a pulmonary photoplethysmographic curve is obtained. The pulmonary photoplethysmographic curves reflect blood volume increase during systole in the pulmonary arteries in the lung tissue, which contain mixed venous blood. The ratio R of the amplitude-to-baseline ratio for the two wavelengths is related to the mixed venous oxygen saturation through equations derived for the systemic pulse oximetry. The method requires the use of extinction coefficients values for oxygenated and deoxygenated hemoglobin, which can be found in the literature.


Asunto(s)
Pulmón/metabolismo , Oximetría/métodos , Oxígeno/sangre , Venas/metabolismo , Humanos , Modelos Teóricos
17.
J Biophotonics ; 6(8): 631-6, 2013 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-22987841

RESUMEN

Changes in finger tissue blood volume (TBV) measured by light transmission and in laser Doppler flow (LDF) were obtained during long breathing (of 12 s period) and associated with the respiratory phases, inspiration and expiration. For fifteen out of sixteen subjects TBV and LDF started to decrease 0-2 s after the start of expiration and increased during inspiration but the start of increase occurred before the start of inspiration, showing that the respiratory-induced changes in TBV and LDF are mainly associated with the expiration. Decrease of TBV and LDF after expiration was also found during the inspiratory gasps


Asunto(s)
Espiración/fisiología , Inhalación/fisiología , Flujometría por Láser-Doppler , Luz , Vasoconstricción , Adulto , Anciano , Volumen Sanguíneo/fisiología , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
18.
Biomed Eng Online ; 8: 28, 2009 Oct 26.
Artículo en Inglés | MEDLINE | ID: mdl-19857254

RESUMEN

BACKGROUND: Automatic measurement of arterial blood pressure is important, but the available commercial automatic blood pressure meters, mostly based on oscillometry, are of low accuracy. METHODS: In this study, we present a cuff-based technique for automatic measurement of systolic blood pressure, based on photoplethysmographic signals measured simultaneously in fingers of both hands. After inflating the pressure cuff to a level above systolic blood pressure in a relatively slow rate, it is slowly deflated. The cuff pressure for which the photoplethysmographic signal reappeared during the deflation of the pressure-cuff was taken as the systolic blood pressure. The algorithm for the detection of the photoplethysmographic signal involves: (1) determination of the time-segments in which the photoplethysmographic signal distal to the cuff is expected to appear, utilizing the photoplethysmographic signal in the free hand, and (2) discrimination between random fluctuations and photoplethysmographic pattern. The detected pulses in the time-segments were identified as photoplethysmographic pulses if they met two criteria, based on the pulse waveform and on the correlation between the signal in each segment and the signal in the two neighboring segments. RESULTS: Comparison of the photoplethysmographic-based automatic technique to sphygmomanometry, the reference standard, shows that the standard deviation of their differences was 3.7 mmHg. For subjects with systolic blood pressure above 130 mmHg the standard deviation was even lower, 2.9 mmHg. These values are much lower than the 8 mmHg value imposed by AAMI standard for automatic blood pressure meters. CONCLUSION: The photoplethysmographic-based technique for automatic measurement of systolic blood pressure, and the algorithm which was presented in this study, seems to be accurate.


Asunto(s)
Fotopletismografía/métodos , Adulto , Anciano , Algoritmos , Automatización , Presión Sanguínea/fisiología , Diseño de Equipo , Humanos , Masculino , Persona de Mediana Edad , Oscilometría/métodos , Reproducibilidad de los Resultados , Esfigmomanometros , Sístole , Factores de Tiempo
19.
J Biomed Opt ; 14(2): 024046, 2009.
Artículo en Inglés | MEDLINE | ID: mdl-19405774

RESUMEN

Pulse oximetry is an optical technique for the assessment of oxygen saturation in arterial blood and is based on the different light absorption spectra for oxygenated and deoxygenated hemoglobin and on two-wavelength photoplethysmographic (PPG) measurement of arterial blood volume increase during systole. The technique requires experimental calibration for the determination of the relationship between PPG-derived parameters and arterial oxygen saturation, and this calibration is a source of error in the method. We suggest a three-wavelength PPG technique for the measurement of arterial oxygen saturation that has no need for calibration if the three wavelengths are properly selected in the near-infrared region. The suggested technique can also be implemented for the assessment of venous oxygen saturation by measuring the decrease in transmission of light through a tissue after increasing its blood volume by venous occlusion. The oxygen saturation in venous blood is a parameter that is related to oxygen consumption in tissue and to tissue blood flow. The three-wavelength method has the potential to provide accurate oxygen saturation measurements in arterial and venous blood, but experimental validation of the theory is still required to confirm this claim.


Asunto(s)
Vasos Sanguíneos/metabolismo , Modelos Cardiovasculares , Oximetría/métodos , Oxígeno/sangre , Refractometría/métodos , Animales , Simulación por Computador , Humanos
20.
Can J Anaesth ; 56(3): 213-21, 2009 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-19247742

RESUMEN

PURPOSE: We tested the hypothesis that the development of sympathectomy-mediated vasodilatation is dependent on the concentration rather than the dose of epidural local anesthetic administered. METHODS: Sixty subjects receiving lumbar epidural bupivacaine were randomised to one of three groups: A: 10 ml 0.5% (50 mg); B: 10 ml 0.25% (25 mg); and C: 40 ml 0.0625% (25 mg). Groups A and B had equal volume but a twofold difference in drug dose, while groups B and C had equal drug dose, but a fourfold difference in drug volume. At baseline and 5, 10, and 20 min following epidural bupivacaine administration, we assessed the following indices of sympathectomy: pulse oximeter perfusion index in the toe and finger, skin temperature in the toe and finger, and mean arterial pressure. We also assessed sensory level (pinprick, cold, and light touch) and motor block. RESULTS: There was an increase in the pulse oximeter perfusion index by 20 min of 280%, 303%, and 59% in groups A, B, and, C, respectively. There was a significant sympathectomy-mediated vasodilatation in the toe for both groups A (P = 0.002) and B (P < 0.001) but not C (P = 0.22). Vasoconstriction in the finger was observed in group A only (P = 0.015) but not in group B (P = 0.09) or group C (P = 0.20). There were similar blood pressure changes and similar sensory changes in all groups. The intensity of motor block increased with increasing drug concentration. CONCLUSIONS: Our observations suggest that drug concentration is more important than drug dose in determining the degree of sympathectomy following lumbar epidural local anesthesia.


Asunto(s)
Anestesia Epidural , Anestésicos Locales/uso terapéutico , Bupivacaína/uso terapéutico , Simpatectomía , Vasodilatación/fisiología , Adulto , Anciano , Anestésicos Locales/administración & dosificación , Anestésicos Locales/efectos adversos , Presión Sanguínea/efectos de los fármacos , Presión Sanguínea/fisiología , Bupivacaína/administración & dosificación , Bupivacaína/efectos adversos , Relación Dosis-Respuesta a Droga , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Bloqueo Nervioso , Dimensión del Dolor/efectos de los fármacos , Fotopletismografía , Estudios Prospectivos , Flujo Sanguíneo Regional/efectos de los fármacos , Flujo Sanguíneo Regional/fisiología , Dedos del Pie/irrigación sanguínea