Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-34281105

RESUMEN

To cope with the shortage of filtering facepiece respirators (FFRs) caused by the coronavirus disease (COVID-19), healthcare institutions have been forced to reuse FFRs using different decontamination methods, including vapor hydrogen peroxide (VHP). However, most healthcare institutions still struggle with evaluating the effect of VHP on filtration efficiency (FE) of the decontaminated FFRs. We developed a low-cost in-house FE assessment using a novel 3D-printed air duct. Furthermore, we assessed the FE of seven types of FFRs. Following 10 VHP cycles, we evaluated the FE of KN95 and 3M-N95 masks. The 3M-N95 and Benehal-N95 masks showed significant lower FE (80.4-91.8%) at fine particle sizes (0.3-1 µm) compared to other FFRs (FE ≥ 98.1%, p < 0.05). Following 10 VHP cycles, the FE of KN95 masks was almost stable (FE stability > 99.1%) for all particle sizes, while 3M-N95 masks were stable only at 2 and 5 µm (FE stability > 98.0%). Statistically, FE stability of 3M-N95 masks at 0.3, 0.5, and 0.7 µm was significantly lower (p ≤ 0.006) than 2 and 5 µm. The in-house FE assessment may be used as an emergency procedure to validate the decontaminated FFRs, as well as a screening option for production control of FFRs. Following VHP cycles, both masks showed high stability at 5 µm, the size of the most suspected droplets implicated in COVID-19 transmission.


Asunto(s)
COVID-19 , Dispositivos de Protección Respiratoria , Descontaminación , Equipo Reutilizado , Filtración , Humanos , Peróxido de Hidrógeno , SARS-CoV-2 , Ventiladores Mecánicos
2.
Med Dosim ; 46(1): 3-12, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-32807612

RESUMEN

Linac based radiosurgery to multiple metastases is commonly planned with volumetric modulated arc therapy (VMAT) as it effectively achieves high conformality to complex target arrangements. However, as the number of targets increases, VMAT can struggle to block between targets, which can lead to highly modulated and/or nonconformal multi-leaf collimator (MLC) trajectories that unnecessarily irradiation of healthy tissue. In this study we introduce, describe, and evaluate a treatment planning technique called Conformal Arc Informed VMAT (CAVMAT), which aims to reduce the dose to healthy tissue while generating highly conformal treatment plans. CAVMAT is a hybrid technique which combines the conformal MLC trajectories of dynamic conformal arcs with the MLC modulation and versatility of inverse optimization. CAVMAT has 3 main steps. First, targets are assigned to subgroups to maximize MLC blocking between targets. Second, arc weights are optimized to achieve the desired target dose, while minimizing MU variation between arcs. Third, the optimized conformal arc plan serves as the starting point for limited inverse optimization to improve dose conformity to each target. Twenty multifocal VMAT cases were replanned with CAVMAT with 20Gy applied to each target. The total volume receiving 2.5Gy[cm3], 6Gy[cm3], 12Gy[cm3], and 16Gy[cm3], conformity index, treatment delivery time, and the total MU were used to compare the VMAT and CAVMAT plans. In addition, CAVMAT was compared to a broad range of planning strategies from various institutions (108 linear accelerator based plans, 14 plans using other modalities) for a 5-target case utilized in a recent plan challenge. For the linear accelerator-based plans, a plan complexity metric based on aperture opening area and perimeter, total monitor units (MU), and MU for a given aperture opening was utilized in the plan challenge scoring algorithm to compare the submitted plans to CAVMAT. After re-planning the 20 VMAT cases, CAVMAT reduced the average V2.5Gy[cm3] by 25.25 ± 19.23%, V6Gy[cm3] by 13.68 ± 18.97%, V12Gy[cm3] by 11.40 ± 19.44%, and V16Gy[cm3] by 6.38 ± 19.11%. CAVMAT improved conformity by 3.81 ± 7.57%, while maintaining comparable target dose. MU for the CAVMAT plans increased by 24.35 ± 24.66%, leading to an increased treatment time of 2 minutes. For the plan challenge case, CAVMAT was 1 of 12 linac based plans that met all plan challenge scoring criteria. Compared to the average submitted VMAT plan, CAVMAT increased the V10%Gy[%] of healthy tissue (Brain-PTV) by roughly 3.42%, but in doing so was able to reduce the V25%Gy[%] by roughly 3.73%, while also reducing V50%Gy[%], V75%Gy[%], and V100%Gy[%]. The CAVMAT technique successfully eliminated insufficient MLC blocking between targets prior to the inverse optimization, leading to less complex treatment plans and improved tissue sparing. Tissue sparing, improved conformity, and decreased plan complexity at the cost of slight increase in treatment delivery time indicates CAVMAT to be a promising method to treat brain metastases.


Asunto(s)
Neoplasias Encefálicas , Radiocirugia , Radioterapia de Intensidad Modulada , Humanos , Dosificación Radioterapéutica , Planificación de la Radioterapia Asistida por Computador
3.
Front Oncol ; 10: 571644, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33344231

RESUMEN

PURPOSE: The aim of this work is to introduce the 2019 International Planning Competition and to analyze its results. METHODS AND MATERIALS: A locally advanced non-small cell lung cancer (LA-NSCLC) case using the simultaneous integrated boost approach was selected. The plan quality was evaluated by using a ranking system in accordance with practice guidelines. Planners used their clinical Treatment Planning System (TPS) to generate the best possible plan along with a survey, designed to obtain medical physics aspects information. We investigated the quality of the large population of plans designed by worldwide planners using different planning and delivery systems. The correlations of plan quality with relevant planner characteristics (work experience, department scale, and competition experience) and with technological parameters (TPS and modality) were examined. RESULTS: The number of the qualified plans was 287 with a wide range of scores (38.61-97.99). The scores showed statistically significant differences by the following factors: 1) department scale: the mean score (89.76 ± 8.36) for planners from the departments treating >2,000 patients annually was the highest of all; 2) competition experience: the mean score for the 107 planners with previous competition experience was 88.92 ± 9.59, statistically significantly from first-time participants (p = .001); 3) techniques: the mean scores for planners using VMAT (89.18 ± 6.43) and TOMO (90.62 ± 7.60) were higher than those using IMRT (82.28 ± 12.47), with statistical differences (p <.001). The plan scores were negligibly correlated with the planner's years of work experience or the type of TPS used. Regression analysis demonstrated that plan score was associated with dosimetric objectives that were difficult to achieve, which is generally consistent with a clinical practice evaluation. However, 51.2% of the planners abandoned the difficult component of total lung receiving a dose of 5 Gy in their plan design to achieve the optimal plan. CONCLUSION: The 2019 international planning competition was carried out successfully, and its results were analyzed. Plan quality was not correlated with work experiences or the TPS used, but it was correlated with department scale, modality, and competition experience. These findings differed from those reported in previous studies.

4.
Brachytherapy ; 16(4): 893-902, 2017.
Artículo en Inglés | MEDLINE | ID: mdl-28457741

RESUMEN

PURPOSE: To describe an EBT3 GAFCHROMIC film-based dosimetry method to be used in commissioning of a combined HDR brachytherapy (HDRB) and stereotactic body radiation therapy (SBRT) boost for treatment of advanced cervical cancer involving extensive residual disease after external beam treatment. METHODS AND MATERIALS: A cube phantom was designed to firmly fit an intrauterine tandem applicator and EBT3 radiochromic film pieces. A high-risk clinical target volume (CTVHR, Total) was contoured with an extended arm at one side. The HDRB treatment was planned to cover the proximal CTVHR, Total with 7 Gy and the distal volume, referred to as CTVHR, Distal, was planned by SBRT for dose augmentation. After HDRB treatment delivery, SBRT treatment was delivered within 1 hour by image guidance using the applicator geometry. Intentional 1D and 2D misalignments were introduced to evaluate the effect on target volumes. In addition, effect of film reirradiation at different time gaps and dose levels was evaluated. RESULTS: Film dosimetric accuracy, with up to 2 hours gap between irradiations, was shown to be unaffected. A 2%/2 mm gamma analysis between measured and planned doses showed agreement of >99%. Misalignments of more than 2 mm between applicator and SBRT isocenter resulted in suboptimal dose-volume histogram affecting mostly D98% and D90% of CTVHR, Distal. CONCLUSIONS: Visualizing how target dose-volume metrics are affected by minor misalignments between SBRT and HDRB dose gradients, in light of achievable phantom-based experimental quality assurance level, encourages the clinical applicability of this technique. Radiochromic film was shown to be a valuable tool to commission procedures combining two different treatment planning systems and modalities with varying dose rates and energy ranges.

5.
Med Dosim ; 40(4): 304-13, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25934344

RESUMEN

The effect of a treatment couch on dose perturbation is not always fully considered in intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). In the course of inverse planning radiotherapy techniques, beam parameter optimization may change in the absence of the couch, causing errors in the calculated dose distributions. Although modern treatment planning systems (TPS) include data for the treatment couch components, they are not manufactured identically. Thus, variations in their Hounsfield unit (HU) values may exist. Moreover, a radiotherapy facility may wish to have a third-party custom tabletop installed that is not included by the TPS vendor. This study demonstrates a practical and simple method of acquiring reliable computed tomography (CT) data for the treatment couch and shows how the absorbed dose calculated with the modeled treatment couch can differ from that with the default treatment couch found in the TPS. We also experimentally verified that neglecting to incorporate the treatment couch completely in the treatment planning process might result in dose differences of up to 9.5% and 7.3% for 4-MV and 10-MV photon beams, respectively. Furthermore, 20 RapidArc and IMRT cases were used to quantify the change in calculated dose distributions caused by using either the default or modeled couch. From 2-dimensional (2D) ionization chamber array measurements, we observed large dose distribution differences between the measurements and calculations when the couch was omitted that varied according to the planning technique and anatomic site. Thus, incorporating the treatment couch in the dose calculation phase of treatment planning significantly decreases dose calculation errors.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Modelos Teóricos , Planificación de la Radioterapia Asistida por Computador/métodos , Radioterapia de Intensidad Modulada/instrumentación , Humanos
6.
J Appl Clin Med Phys ; 15(6): 5006, 2014 Nov 08.
Artículo en Inglés | MEDLINE | ID: mdl-25493527

RESUMEN

In this work we compare doses from imaging procedures performed on today's state-of-the-art integrated imaging systems using a reference radiochromic film dosimetry system. Skin dose and dose profile measurements from different imaging systems were performed using radiochromic films at different anatomical sites on a humanoid RANDO phantom. EBT3 film was used to measure imaging doses from a TomoTherapy MVCT system, while XRQA2 film was used for dose measurements from kilovoltage imaging systems (CBCT on 21eX and TrueBeam Varian linear accelerators and CyberKnife stereoscopic orthogonal imagers). Maximum measured imaging doses in cGy at head, thorax, and pelvis regions were respectively 0.50, 1.01, and 4.91 for CBCT on 21eX, 0.38, 0.84, and 3.15 for CBCT on TrueBeam, 4.33, 3.86, and 6.50 for CyberKnife imagers, and 3.84, 1.90, and 2.09 for TomoTherapy MVCT. In addition, we have shown how an improved calibration system of XRQA2 film can achieve dose uncertainty level of better than 2% for doses above 0.25 cGy. In addition to simulation-based studies in literature, this study provides the radiation oncology team with data necessary to aid in their decision about imaging frequency for image-guided radiation therapy protocols.


Asunto(s)
Dosimetría por Película , Dosificación Radioterapéutica , Radioterapia Guiada por Imagen/métodos , Humanos , Radioterapia Guiada por Imagen/normas
7.
J Appl Clin Med Phys ; 12(3): 3432, 2011 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-21844854

RESUMEN

Impact of the various kVp settings used during computed tomography (CT) simulation that provides data for heterogeneity corrected dose distribution calculations in patients undergoing external beam radiotherapy with either high-energy photon or electron beams have been investigated. The change of the Hounsfield Unit (HU) values due to the influence of kVp settings and geometrical distribution of various tissue substitute materials has also been studied. The impact of various kVp settings and electron density (ED) distribution on the accuracy of dose calculation in high-energy photon beams was found to be well within 2%. In the case of dose distributions obtained with a commercially available Monte Carlo dose calculation algorithm for electron beams, differences of more than 10% were observed for different geometrical setups and kVp settings. Dose differences for the electron beams are relatively small at shallow depths but increase with depth around lower isodose values.


Asunto(s)
Algoritmos , Electrones , Dosis de Radiación , Tomografía Computarizada por Rayos X/métodos , Simulación por Computador , Humanos , Método de Montecarlo , Fotones/uso terapéutico , Sensibilidad y Especificidad , Rayos X
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...