Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Medicina (Kaunas) ; 59(2)2023 Feb 02.
Artículo en Inglés | MEDLINE | ID: mdl-36837491

RESUMEN

Background and Objectives: Increased revision rate of dual-modular (DM) femoral stems in primary total hip arthroplasty (THA) because of modular-neck breakage and adverse local tissue reactions (ALTRs) to additional junction damage products is well established and some designs have been recalled from the market. However, some long-term studies of specific DM stems did not confirm the inferiority of these stems compared to standard single-modular (SM) stems, and a head-to-head comparison THA is missing. The objectives of this multicentre study were to determine the survivorship and complication rates of a common DM stem design compared to a similar SM stem. Materials and Methods: In a time frame from January 2012 to November 2015, a cohort of 807 patients (882 hips) consecutively underwent primary cementless THAs at two orthopaedic centres. 377 hips were treated with a Zweimüller-type DM stem THA system and 505 hips with a similar SM stem THA system, both including a modern press-fit acetabulum. Kaplan-Meier survivorship and complication rates were compared between both groups in a median follow-up of 9.0 years (maximum, 9.9 years). Results: The 9-year survivorship of the DM stem THA system (92.6%, 95% CI 89.9-95.3) was significantly lower than that of the SM stem THA system (97.0%, 95% CI 95.2-98.8). There were no differences in revision rates for septic loosening, dislocation, and periprosthetic fractures between the two groups. One ceramic inlay and one Ti-alloy modular neck breakage occurred in the DM stem THA system group, but the main reason for revision in this group was aseptic loosening of components. Conclusions: The survivorship of the DM stem THA system was lower than the similar SM stem THA system in a comparable clinical environment with long-term follow-up. Our results confirmed that no rationale for stem modularity exists in primary THAs.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Prótesis de Cadera , Humanos , Artroplastia de Reemplazo de Cadera/efectos adversos , Prótesis de Cadera/efectos adversos , Falla de Prótesis , Diseño de Prótesis , Reoperación , Estimación de Kaplan-Meier , Estudios Retrospectivos , Estudios de Seguimiento , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...