Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Rev Sci Instrum ; 82(4): 043501, 2011 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-21529003

RESUMEN

An electric-field sensor consisting of thin copper plates is designed to measure an oscillating electric field produced by charge separations on a plasma column. The sensor installed in a vacuum region around plasma detects charges induced by the electric field on the copper plates. The value of the induced charges depends not only on the strength of the electric field, but also on the design of the sensor. To obtain the correct strength of the electric field, a correction factor arising from the design of the sensor must be known. The factor is calculated numerically using Laplace's equation and compared with a value measured using a uniform electric field in the frequency range of 10-500 kHz. When an external circuit is connected to the sensor to measure the induced charges, the electric field around the sensor is disturbed. Therefore, a double-sensor method for excluding a disturbed component in the measured electric field is proposed. The reliability of the double-sensor method is confirmed by measuring dipole-like and quadrupole-like electric fields.

2.
Rev Sci Instrum ; 79(6): 063501, 2008 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-18601402

RESUMEN

A confinement field is disturbed by magnetohydrodynamic (MHD) motions of a field-reversed configuration (FRC) plasma in a cylindrical conductor. The effect of the conductor should be included to obtain a spatial structure of the disturbed field with a good precision. For this purpose, a toroidal current in the plasma and an eddy current on a conducting wall are replaced by magnetic dipole and image magnetic dipole moments, respectively. Typical spatial structures of the disturbed field are calculated by using the dipole moments for such MHD motions as radial shift, internal tilt, external tilt, and n=2 mode deformation. Then, analytic formulas for estimating the shift distance, tilt angle, and deformation rate of the MHD motions from magnetic probe signals are derived. It is estimated from the calculations by using the dipole moments that the analytic formulas include an approximately 40% error. Two kinds of experiment are carried out to investigate the reliability of the calculations. First, a magnetic field produced by a circular current is measured in an aluminum pipe to confirm the replacement of the eddy current with the image magnetic dipole moments. The measured fields coincide well with the calculated values including the image magnetic dipole moments. Second, magnetic probe signals measured from the FRC plasma are substituted into the analytic formulas to obtain shift distance and deformation rate. The experimental results are compared to the MHD motions measured by using a radiation from the plasma. If the error included in the analytic formulas and the difference between the magnetic and optical structures in the plasma are considered, the results of the radiation measurement support well those of the magnetic analysis.

3.
Rev Sci Instrum ; 78(3): 036105, 2007 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-17411230

RESUMEN

A magnetic probe array is constructed to measure precisely the spatial structure of a small fluctuating field included in a strong confinement field that varies with time. To exclude the effect of the confinement field, the magnetic probes consisting of figure-eight-wound coils are prepared. The spatial structure of the fluctuating field is obtained from a Fourier analysis of the probe signal. It is found that the probe array is more sensitive to the fluctuating field with a high mode number than that with a low mode number. An experimental demonstration of the present method is attempted using a field-reversed configuration plasma, where the fluctuating field with 0.1% of the confinement field is successfully detected.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...