Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Biomed Opt Express ; 14(7): 3446-3457, 2023 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-37497509

RESUMEN

All-optical ultrasound (OpUS) has emerged as an imaging paradigm well-suited to minimally invasive imaging due to its ability to provide high resolution imaging from miniaturised fibre optic devices. Here, we report a fibre optic device capable of concurrent laser interstitial thermal therapy (LITT) and real-time in situ all-optical ultrasound imaging for lesion monitoring. The device comprised three optical fibres: one each for ultrasound transmission, reception and thermal therapy light delivery. This device had a total lateral dimension of <1 mm and was integrated into a medical needle. Simultaneous LITT and monitoring were performed on ex vivo lamb kidney with lesion depth tracked using M-mode OpUS imaging. Using one set of laser energy parameters for LITT (5 W, 60 s), the lesion depth varied from 3.3 mm to 8.3 mm. In all cases, the full lesion depth could be visualised and measured with the OpUS images and there was a good statistical agreement with stereomicroscope images acquired after ablation (t=1.36, p=0.18). This work demonstrates the feasibility and potential of OpUS to guide LITT in tumour resection.

2.
Int J Comput Assist Radiol Surg ; 18(2): 395-399, 2023 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36057759

RESUMEN

PURPOSE: Instrumented ultrasonic tracking provides needle localisation during ultrasound-guided minimally invasive percutaneous procedures. Here, a post-processing framework based on a convolutional neural network (CNN) is proposed to improve the spatial resolution of ultrasonic tracking images. METHODS: The custom ultrasonic tracking system comprised a needle with an integrated fibre-optic ultrasound (US) transmitter and a clinical US probe for receiving those transmissions and for acquiring B-mode US images. For post-processing of tracking images reconstructed from the received fibre-optic US transmissions, a recently-developed framework based on ResNet architecture, trained with a purely synthetic dataset, was employed. A preliminary evaluation of this framework was performed with data acquired from needle insertions in the heart of a fetal sheep in vivo. The axial and lateral spatial resolution of the tracking images were used as performance metrics of the trained network. RESULTS: Application of the CNN yielded improvements in the spatial resolution of the tracking images. In three needle insertions, in which the tip depth ranged from 23.9 to 38.4 mm, the lateral resolution improved from 2.11 to 1.58 mm, and the axial resolution improved from 1.29 to 0.46 mm. CONCLUSION: The results provide strong indications of the potential of CNNs to improve the spatial resolution of ultrasonic tracking images and thereby to increase the accuracy of needle tip localisation. These improvements could have broad applicability and impact across multiple clinical fields, which could lead to improvements in procedural efficiency and reductions in risk of complications.


Asunto(s)
Aprendizaje Profundo , Ovinos , Animales , Ultrasonido , Ultrasonografía/métodos , Agujas , Redes Neurales de la Computación
3.
Adv Funct Mater ; 33(50): 2301857, 2023 Dec 08.
Artículo en Inglés | MEDLINE | ID: mdl-38495320

RESUMEN

Smart robotic devices remotely powered by magnetic field have emerged as versatile tools for wide biomedical applications. Soft magnetic elastomer (ME) composite membranes with high flexibility and responsiveness are frequently incorporated to enable local actuation for wireless sensing or cargo delivery. However, the fabrication of thin ME membranes with good control in geometry and uniformity remains challenging, as well as the optimization of their actuating performances under low fields (milli-Tesla). In this work, the development of ME membranes comprising of low-cost magnetic powder and highly soft elastomer through a simple template-assisted doctor blading approach, is reported. The fabricated ME membranes are controllable in size (up to centimetre-scale), thickness (tens of microns) and high particle loading (up to 70 wt.%). Conflicting trade-off effects of particle concentration upon magnetic responsiveness and mechanical stiffness are investigated and found to be balanced off as it exceeds 60 wt.%. A highly sensitive fibre-optic interferometric sensing system and a customized fibre-ferrule-membrane probe are first proposed to enable dynamic actuation and real-time displacement characterization. Free-standing ME membranes are magnetically excited under low field down to 2 mT, and optically monitored with nanometer accuracy. The fast and consistent responses of ME membranes showcase their promising biomedical applications in nanoscale actuation and sensing.

4.
Sensors (Basel) ; 22(17)2022 Aug 25.
Artículo en Inglés | MEDLINE | ID: mdl-36080876

RESUMEN

Ultrasound (US) image guidance is widely used for minimally invasive procedures, but the invasive medical devices (such as metallic needles), especially their tips, can be poorly visualised in US images, leading to significant complications. Photoacoustic (PA) imaging is promising for visualising invasive devices and peripheral tissue targets. Light-emitting diodes (LEDs) acting as PA excitation sources facilitate the clinical translation of PA imaging, but the image quality is degraded due to the low pulse energy leading to insufficient contrast with needles at deep locations. In this paper, photoacoustic visualisation of clinical needles was enhanced by elastomeric nanocomposite coatings with superficial and interstitial illumination. Candle soot nanoparticle-polydimethylsiloxane (CSNP-PDMS) composites with high optical absorption and large thermal expansion coefficients were applied onto the needle exterior and the end-face of an optical fibre placed in the needle lumen. The excitation light was delivered at the surface by LED arrays and through the embedded optical fibre by a pulsed diode laser to improve the visibility of the needle tip. The performance was validated using an ex-vivo tissue model. An LED-based PA/US imaging system was used for imaging the needle out-of-plane and in-plane insertions over approach angles of 20 deg to 55 deg. The CSNP-PDMS composite conferred substantial visual enhancements on both the needle shaft and the tip, with an average of 1.7- and 1.6-fold improvements in signal-to-noise ratios (SNRs), respectively. With the extended light field involving extracorporeal and interstitial illumination and the highly absorbing coatings, enhanced visualisation of the needle shaft and needle tip was achieved with PA imaging, which could be helpful in current US-guided minimally invasive surgeries.


Asunto(s)
Nanocompuestos , Agujas , Iluminación , Análisis Espectral , Ultrasonografía
5.
MRS Adv ; 7(23-24): 499-503, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35694205

RESUMEN

Abstract: All-optical ultrasound (OpUS) imaging has emerged as an imaging paradigm well-suited for minimally invasive surgical procedures. With this modality, ultrasound is generated when pulsed or modulated light is absorbed within a coating material. By engineering wavelength-selective coatings, complementary imaging and therapeutic modalities can be integrated with OpUS. Here, we present a wavelength-selective composite material comprising a near-infrared absorbing dye and polydimethylsiloxane. The optical absorption for this material peaked in the vicinity of 1064 nm, with up to 91% of incident light being absorbed, whilst maintaining lower optical absorption at other wavelengths. This material was used to generate ultrasound, demonstrating ultrasound pressures > 1  MPa, consistent with those used for imaging applications. Crucially, long exposure photostability and device performance were found to be stable over a one hour period (peak pressure variation < 10 %), longer than required for standard clinical imaging applications.

6.
Adv Mater Interfaces ; 8(20): 2100518, 2021 Oct 22.
Artículo en Inglés | MEDLINE | ID: mdl-34777946

RESUMEN

Dual-modality imaging employing complementary modalities, such as all-optical ultrasound and photoacoustic imaging, is emerging as a well-suited technique for guiding minimally invasive surgical procedures. Quantum dots are a promising material for use in these dual-modality imaging devices as they can provide wavelength-selective optical absorption. The first quantum dot nanocomposite engineered for co-registered laser-generated ultrasound and photoacoustic imaging is presented. The nanocomposites developed, comprising CuInS2 quantum dots and medical-grade polydimethylsiloxane (CIS-PDMS), are applied onto the distal ends of miniature optical fibers. The films exhibit wavelength-selective optical properties, with high optical absorption (> 90%) at 532 nm for ultrasound generation, and low optical absorption (< 5%) at near-infrared wavelengths greater than 700 nm. Under pulsed laser irradiation, the CIS-PDMS films generate ultrasound with pressures exceeding 3.5 MPa, with a corresponding bandwidth of 18 MHz. An ultrasound transducer is fabricated by pairing the coated optical fiber with a Fabry-Pérot (FP) fiber optic sensor. The wavelength-selective nature of the film is exploited to enable co-registered all-optical ultrasound and photoacoustic imaging of an ink-filled tube phantom. This work demonstrates the potential for quantum dots as wavelength-selective absorbers for all-optical ultrasound generation.

7.
Ultrasonics ; 116: 106514, 2021 Jul 12.
Artículo en Inglés | MEDLINE | ID: mdl-34280811

RESUMEN

All-optical ultrasound (AOUS) imaging, which uses light to both generate and detect ultrasound, is an emerging alternative to conventional electronic ultrasound imaging. To date, AOUS imaging has been performed using paradigms that either resulted in long acquisition times or employed bench-top imaging systems that were impractical for clinical use. In this work, we present a novel AOUS imaging paradigm where scanning optics are used to rapidly synthesise an imaging aperture. This paradigm enabled the first AOUS system with a flexible, handheld imaging probe, which represents a critical step towards clinical translation. This probe, which provides video-rate imaging and a real-time display, is demonstrated with phantoms and in vivo human tissue.

8.
J Acoust Soc Am ; 149(4): 2732, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33940866

RESUMEN

Laser-generated focused ultrasound (LGFU) transducers used for ultrasound therapy commonly have large diameters (6-15 mm), but smaller lateral dimensions (<4 mm) are required for interventional applications. To address the question of whether miniaturized LGFU transducers could generate sufficient pressure at the focus to enable therapeutic effects, a modelling and measurement study is performed. Measurements are carried out for both linear and nonlinear propagation for various illumination schemes and compared with the model. The model comprises several innovations. First, the model allows for radially varying acoustic input distributions on the surface of the LGFU transducer, which arise from the excitation light impinging on the curved transducer surfaces. This realistic representation of the source prevents the overestimation of the achievable pressures (shown here to be as high as 1.8 times). Second, an alternative inverse Gaussian illumination paradigm is proposed to achieve higher pressures; a 35% increase is observed in the measurements. Simulations show that LGFU transducers as small as 3.5 mm could generate sufficient peak negative pressures at the focus to exceed the cavitation threshold in water and blood. Transducers of this scale could be integrated with interventional devices, thereby opening new opportunities for therapeutic applications from inside the body.


Asunto(s)
Transductores , Terapia por Ultrasonido , Acústica , Rayos Láser
9.
Artículo en Inglés | MEDLINE | ID: mdl-33035154

RESUMEN

A broadband all-optical plane-wave ultrasound imaging system for high-resolution 3-D imaging of biological tissues is presented. The system is based on a planar Fabry-Perot (FP) scanner for ultrasound detection and the photoacoustic generation of ultrasound in a carbon-nanotube-polydimethylsiloxane (CNT-PDMS) composite film. The FP sensor head was coated with the CNT-PDMS film which acts as an ultrasound transmitting layer for pulse-echo imaging. Exciting the CNT-PDMS coating with nanosecond laser pulses generated monopolar plane-wave ultrasound pulses with MPa-range peak pressures and a -6-dB bandwidth of 22 MHz, which were transmitted into the target. The resulting scattered acoustic field was detected across a 15 mm ×15 mm scan area with a step size of 100 [Formula: see text] and an optically defined element size of [Formula: see text]. The -3-dB bandwidth of the sensor was 30 MHz. A 3-D image of the scatterer distribution was then recovered using a k -space reconstruction algorithm. To obtain a measure of spatial resolution, the instrument line-spread function (LSF) was measured as a function of position. At the center of the scan area, the depth-dependent lateral LSF ranged from 46 to 65 [Formula: see text] for depths between 1 and 12 mm. The vertical LSF was independent of position and measured to be [Formula: see text] over the entire field of view. To demonstrate the ability of the system to provide high-resolution 3-D images, phantoms with well-defined scattering structures of arbitrary geometry were imaged. To demonstrate its suitability for imaging biological tissues, phantoms with similar impedance mismatches, sound speed and scattering properties to those present in the tissue, and ex vivo tissue samples were imaged. Compared with conventional piezoelectric-based ultrasound scanners, this approach offers the potential for improved image quality and higher resolution for superficial tissue imaging. Since the FP scanner is capable of high-resolution 3-D photoacoustic imaging of in vivo biological tissues, the system could ultimately be developed into an instrument for dual-mode all-optical ultrasound and photoacoustic imaging.


Asunto(s)
Algoritmos , Imagenología Tridimensional , Acústica , Fantasmas de Imagen , Ultrasonografía
10.
Front Cardiovasc Med ; 7: 525530, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33173786

RESUMEN

Conventional intravascular ultrasound (IVUS) devices use piezoelectric transducers to electrically generate and receive US. With this paradigm, there are numerous challenges that restrict improvements in image quality. First, with miniaturization of the transducers to reduce device size, it can be challenging to achieve the sensitivities and bandwidths required for large tissue penetration depths and high spatial resolution. Second, complexities associated with manufacturing miniaturized electronic transducers can have significant cost implications. Third, with increasing interest in molecular characterization of tissue in-vivo, it has been challenging to incorporate optical elements for multimodality imaging with photoacoustics (PA) or near-infrared spectroscopy (NIRS) whilst maintaining the lateral dimensions suitable for intracoronary imaging. Optical Ultrasound (OpUS) is a new paradigm for intracoronary imaging. US is generated at the surface of a fiber optic transducer via the photoacoustic effect. Pulsed or modulated light is absorbed in an engineered coating on the fiber surface and converted to thermal energy. The subsequent temperature rise leads to a pressure rise within the coating, which results in a propagating ultrasound wave. US reflections from imaged structures are received with optical interferometry. With OpUS, high bandwidths (31.5 MHz) and pressures (21.5 MPa) have enabled imaging with axial resolutions better than 50 µm and at depths >20 mm. These values challenge those of conventional 40 MHz IVUS technology and show great potential for future clinical application. Recently developed nanocomposite coating materials, that are highly transmissive at light wavelengths used for PA and NIRS light, can facilitate multimodality imaging, thereby enabling molecular characterization.

11.
ACS Infect Dis ; 6(5): 939-946, 2020 05 08.
Artículo en Inglés | MEDLINE | ID: mdl-32126763

RESUMEN

Hospital-acquired bacterial infections are a significant burden on healthcare systems worldwide causing an increased duration of hospital stays and prolonged patient suffering. We show that polyurethane containing crystal violet (CV) and 3-4 nm zinc oxide nanoparticles (ZnO NPs) possesses excellent bactericidal activity against hospital-acquired pathogens including multidrug resistant Escherichia coli (E. coli), Pseudomonas aeruginosa, methicillin-resistant Staphylococcus aureus (MRSA), and even highly resistant endospores of Clostridioides (Clostridium) difficile. Importantly, we used clinical isolates of bacterial strains, a protocol to mimic the environmental conditions of a real exposure in the healthcare setting, and low light intensity equivalent to that encountered in UK hospitals (∼500 lux). Our data shows that ZnO NPs enhance the photobactericidal activity of CV under low intensity light even with short exposure times, and we show that this involves both Type I and Type II photochemical pathways. Interestingly, polyurethane containing ZnO NPs alone showed significant bactericidal activity in the dark against one strain of E. coli, indicating that the NPs possess both light-activated synergistic activity with CV and inherent bactericidal activity that is independent of light. These new antibacterial polymers are potentially useful in healthcare facilties to reduce the transmission of pathogens between people and the environment.


Asunto(s)
Antiinfecciosos/farmacología , Clostridioides difficile/efectos de los fármacos , Escherichia coli/efectos de los fármacos , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Pseudomonas aeruginosa/efectos de los fármacos , Antibacterianos/farmacología , Infección Hospitalaria/prevención & control , Farmacorresistencia Bacteriana Múltiple , Violeta de Genciana/farmacología , Humanos , Luz , Pruebas de Sensibilidad Microbiana , Nanopartículas , Poliuretanos , Óxido de Zinc/farmacología
12.
Sci Rep ; 9(1): 5576, 2019 04 03.
Artículo en Inglés | MEDLINE | ID: mdl-30944379

RESUMEN

Miniaturised high-resolution imaging devices are valuable for guiding minimally invasive procedures such as vascular stent placements. Here, we present all-optical rotational B-mode pulse-echo ultrasound imaging. With this device, ultrasound transmission and reception are performed with light. The all-optical transducer in the probe comprised an optical fibre that delivered pulsed excitation light to an optical head at the distal end with a multi-walled carbon nanotube and polydimethylsiloxane composite coating. This coating was photoacoustically excited to generate a highly directional ultrasound beam perpendicular to the optical fibre axis. A concave Fabry-Pérot cavity at the distal end of an optical fibre, which was interrogated with a tuneable continuous-wave laser, served as an omnidirectional ultrasound receiver. The transmitted ultrasound had a -6 dB bandwidth of 31.3 MHz and a peak-to-peak pressure of 1.87 MPa, as measured at 1.5 mm from the probe. The receiver had a noise equivalent pressure <100 Pa over a 20 MHz bandwidth. With a maximum outer probe diameter of 1.25 mm, the probe provided imaging with an axial resolution better than 50 µm, and a real-time imaging rate of 5 frames per second. To investigate the capabilities of the probe, intraluminal imaging was performed in healthy swine carotid arteries. The results demonstrate that the all-optical probe is viable for clinical rotational ultrasound imaging.

13.
J Biomed Opt ; 24(2): 1-4, 2019 02.
Artículo en Inglés | MEDLINE | ID: mdl-30770678

RESUMEN

Microscopic and mesoscale optical imaging techniques allow for three-dimensional (3-D) imaging of biological tissue across millimeter-scale regions, and imaging phantom models are invaluable for system characterization and clinical training. Phantom models that replicate complex 3-D geometries with both structural and molecular contrast, with resolution and lateral dimensions equivalent to those of imaging techniques (<20 µm), have proven elusive. We present a method for fabricating phantom models using a combination of two-photon polymerization (2PP) to print scaffolds, and microinjection of tailored tissue-mimicking materials to simulate healthy and diseased tissue. We provide a first demonstration of the capabilities of this method with intravascular optical coherence tomography, an imaging technique widely used in clinical practice. We describe the design, fabrication, and validation of three types of phantom models: a first with subresolution wires (5- to 34-µm diameter) arranged circumferentially, a second with a vessel side-branch, and a third containing a lipid inclusion within a vessel. Silicone hybrid materials and lipids, microinjected within a resin framework created with 2PP, served as tissue-mimicking materials that provided realistic optical scattering and absorption. We demonstrate that optical phantom models made with 2PP and microinjected tissue-mimicking materials can simulate complex anatomy and pathology with exquisite detail.


Asunto(s)
Diagnóstico por Imagen/métodos , Imagenología Tridimensional/métodos , Imagen Óptica/métodos , Fantasmas de Imagen , Biomimética , Diseño Asistido por Computadora , Percepción de Profundidad , Humanos , Lípidos/química , Modelos Teóricos , Fotones , Impresión Tridimensional , Refractometría , Siliconas/química , Tomografía de Coherencia Óptica/métodos
14.
Biomed Opt Express ; 9(8): 3481-3494, 2018 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-30338133

RESUMEN

All-optical ultrasound imaging, where ultrasound is generated and detected using light, has recently been demonstrated as a viable modality that is inherently insensitive to electromagnetic interference and exhibits wide bandwidths. High-quality 2D and 3D all-optical ultrasound images of tissues have previously been presented; however, to date, long acquisition times (ranging from minutes to hours) have hindered clinical application. Here, we present the first all-optical ultrasound imaging system capable of video-rate, real-time two-dimensional imaging of biological tissue. This was achieved using a spatially extended nano-composite optical ultrasound generator, a highly sensitive fibre-optic acoustic receiver, and eccentric illumination resulting in an acoustic source exhibiting optimal directivity. This source was scanned across a one-dimensional source aperture using a fast galvo mirror, thus enabling the dynamic synthesis of source arrays comprising spatially overlapping sources at non-uniform source separation distances. The resulting system achieved a sustained frame rate of 15 Hz, a dynamic range of 30 dB, a penetration depth of at least 6 mm, a resolution of 75 µm (axial) by 100 µm (lateral), and enabled the dynamics of a pulsating ex vivo carotid artery to be captured.

15.
ACS Appl Mater Interfaces ; 10(1): 98-104, 2018 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-29210273

RESUMEN

The development of photoactivated antimicrobial surfaces that kill pathogens through the production of singlet oxygen has proved very effective in recent years, with applications in medical devices and hospital touch surfaces, to improve patient safety and well being. However, many of these surfaces require a swell-encapsulation-shrink strategy to incorporate the photoactive agents in a polymer matrix, and this is resource intensive, given that only the surface fraction of the agent is active against bacteria. Furthermore, there is a risk that the agent will leach from the polymer and thus raises issues of biocompatibility and patient safety. Here, we describe a more efficient method of fabricating a silicone material with a covalently attached monolayer of photoactivating agent that uses heavy-atom triplet sensitization for improved singlet oxygen generation and corresponding antimicrobial activity. We use boron-dipyrromethane with a reactive end group and incorporated Br atoms, covalently attached to poly(dimethylsiloxane). We demonstrate the efficacy of this material in producing singlet oxygen and killing Staphylococcus aureus and suggest how it might be easily modifiable for future antimicrobial surface development.


Asunto(s)
Compuestos de Boro/química , Antibacterianos , Oxígeno Singlete
16.
J Med Robot Res ; 32018 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-30820482

RESUMEN

By intervening during the early stage of gestation, fetal surgeons aim to correct or minimize the effects of congenital disorders. As compared to postnatal treatment of these disorders, such early interventions can often actually save the life of the fetus and also improve the quality of life of the newborn. However, fetal surgery is considered one of the most challenging disciplines within Minimally Invasive Surgery (MIS), owing to factors such as the fragility of the anatomic features, poor visibility, limited manoeuvrability, and extreme requirements in terms of instrument handling with precise positioning. This work is centered on a fetal laser surgery procedure treating placental disorders. It proposes the use of haptic guidance to enhance the overall safety of this procedure and to simplify instrument handling. A method is described that provides effective guidance by installing a forbidden region virtual fixture over the placenta, thereby safeguarding adequate clearance between the instrument tip and the placenta. With a novel application of all-optical ultrasound distance sensing in which transmission and reception are performed with fibre optics, this method can be used with a sole reliance on intraoperatively acquired data. The added value of the guidance approach, in terms of safety and performance, is demonstrated in a series of experiments with a robotic platform.

17.
Sci Rep ; 7(1): 15298, 2017 11 10.
Artículo en Inglés | MEDLINE | ID: mdl-29127333

RESUMEN

Evidence has shown that environmental surfaces play an important role in the transmission of nosocomial pathogens. Deploying antimicrobial surfaces in hospital wards could reduce the role environmental surfaces play as reservoirs for pathogens. Herein we show a significant reduction in viable counts of Staphylococcus epidermidis, Saccharomyces cerevisiae, and MS2 Bacteriophage after light treatment of a medical grade silicone incorporating crystal violet, methylene blue and 2 nm gold nanoparticles. Furthermore, a migration assay demonstrated that in the presence of light, growth of the fungus-like organism Pythium ultimum and the filamentous fungus Botrytis cinerea was inhibited. Atomic Force Microscopy showed significant alterations to the surface of S. epidermidis, and electron microscopy showed cellular aggregates connected by discrete surface linkages. We have therefore demonstrated that the embedded surface has a broad antimicrobial activity under white light and that the surface treatment causes bacterial envelope damage and cell aggregation.


Asunto(s)
Antiinfecciosos/química , Hongos/crecimiento & desarrollo , Levivirus/crecimiento & desarrollo , Luz , Staphylococcus epidermidis/crecimiento & desarrollo , Hongos/ultraestructura , Violeta de Genciana/química , Oro/química , Levivirus/ultraestructura , Nanopartículas del Metal/química , Azul de Metileno/química , Staphylococcus epidermidis/ultraestructura , Propiedades de Superficie
18.
Med Image Comput Comput Assist Interv ; 10434: 637-645, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-28948240

RESUMEN

Ultrasound imaging is widely used for guiding minimally invasive procedures, including fetal surgery. Visualisation of medical devices such as medical needles is critically important and it remains challenging in many clinical contexts. During in-plane insertions, a needle can have poor visibility at steep insertion angles and at large insertion depths. During out-of-plane insertions, the needle tip can have a similar ultrasonic appearance to the needle shaft when it intersects with the ultrasound imaging plane. When the needle tip is not accurately identified, it can damage critical structures, with potentially severe consequences, including loss of pregnancy. In this paper, we present a tracking system to directly visualise the needle tip with an ultrasonic beacon. The waves transmitted by the beacon were received by an external ultrasound imaging probe. Pairs of co-registered images were acquired in rapid succession with this probe: a photoacoustic image obtained with the system in receive-only mode, and a conventional B-mode ultrasound image. The beacon comprised a custom elastomeric nanocomposite coating at the distal end of an optical fibre, which was positioned within the lumen of a commercial 22 gauge needle. Delivery of pulsed light to the coating resulted in the photoacoustic generation of ultrasonic waves. The measured tracking accuracies in water in the axial and lateral dimensions were 0.39±0.19 mm and 1.85±0.29 mm, respectively. To obtain a preliminary indication of the clinical potential of this ultrasonic needle tracking system, needle insertions were performed in an in vivo fetal sheep model. The results demonstrate that ultrasonic needle tracking with a fibre-optic transmitter is feasible in a clinically realistic fetal surgery environment, and that it could be useful to guide minimally invasive procedures by providing accurate visualisation of the medical device tip.


Asunto(s)
Feto/cirugía , Agujas , Ultrasonografía Intervencional/métodos , Algoritmos , Animales , Femenino , Feto/diagnóstico por imagen , Embarazo , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Ovinos
19.
Appl Phys Lett ; 110(22): 223701, 2017 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-28652642

RESUMEN

All-optical ultrasound transducers are promising for imaging applications in minimally invasive surgery. In these devices, ultrasound is transmitted and received through laser modulation, and they can be readily miniaturized using optical fibers for light delivery. Here, we report optical ultrasound transmitters fabricated by electrospinning an absorbing polymer composite directly onto the end-face of optical fibers. The composite coating consisting of an aqueous dispersion of multi-walled carbon nanotubes (MWCNTs) in polyvinyl alcohol was directly electrospun onto the cleaved surface of a multimode optical fiber and subsequently dip-coated with polydimethylsiloxane (PDMS). This formed a uniform nanofibrous absorbing mesh over the optical fiber end-face wherein the constituent MWCNTs were aligned preferentially along individual nanofibers. Infiltration of the PDMS through this nanofibrous mesh onto the underlying substrate was observed and the resulting composites exhibited high optical absorption (>97%). Thickness control from 2.3 µm to 41.4 µm was obtained by varying the electrospinning time. Under laser excitation with 11 µJ pulse energy, ultrasound pressures of 1.59 MPa were achieved at 1.5 mm from the coatings. On comparing the electrospun ultrasound transmitters with a dip-coated reference fabricated using the same constituent materials and possessing identical optical absorption, a five-fold increase in the generated pressure and wider bandwidth was observed. The electrospun transmitters exhibited high optical absorption, good elastomer infiltration, and ultrasound generation capability in the range of pressures used for clinical pulse-echo imaging. All-optical ultrasound probes with such transmitters fabricated by electrospinning could be well-suited for incorporation into catheters and needles for diagnostics and therapeutic applications.

20.
Sci Rep ; 7(1): 1208, 2017 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-28446784

RESUMEN

A miniature all-optical ultrasound imaging system is presented that generates three-dimensional images using a stationary, real acoustic source aperture. Discrete acoustic sources were sequentially addressed by scanning a focussed optical beam across the proximal end of a coherent fibre bundle; high-frequency ultrasound (156% fractional bandwidth centred around 13.5 MHz) was generated photoacoustically in the corresponding regions of an optically absorbing coating deposited at the distal end. Paired with a single fibre-optic ultrasound detector, the imaging probe (3.5 mm outer diameter) achieved high on-axis resolutions of 97 µm, 179 µm and 110 µm in the x, y and z directions, respectively. Furthermore, the optical scan pattern, and thus the acoustic source array geometry, was readily reconfigured. Implementing four different array geometries revealed a strong dependency of the image quality on the source location pattern. Thus, by employing optical technology, a miniature ultrasound probe was fabricated that allows for arbitrary source array geometries, which is suitable for three-dimensional endoscopic and laparoscopic imaging, as was demonstrated on ex vivo porcine cardiac tissue.


Asunto(s)
Endosonografía/métodos , Imagenología Tridimensional/métodos , Imagen Óptica/métodos , Técnicas Fotoacústicas/métodos , Endosonografía/instrumentación , Imagenología Tridimensional/instrumentación , Imagen Óptica/instrumentación , Técnicas Fotoacústicas/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...