Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
iScience ; 26(5): 106694, 2023 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-37124417

RESUMEN

Evaluating the serum cross-neutralization responses after breakthrough infection with various SARS-CoV-2 variants provides valuable insight for developing variant-proof COVID-19 booster vaccines. However, fairly comparing the impact of breakthrough infections with distinct epidemic timing on cross-neutralization responses, influenced by the exposure interval between vaccination and infection, is challenging. To compare the impact of pre-Omicron to Omicron breakthrough infection, we estimated the effects on cross-neutralizing responses by the exposure interval using Bayesian hierarchical modeling. The saturation time required to generate saturated cross-neutralization responses differed by variant, with variants more antigenically distant from the ancestral strain requiring longer intervals of 2-4 months. The breadths of saturated cross-neutralization responses to Omicron lineages were comparable in pre-Omicron and Omicron breakthrough infections. Our results highlight the importance of vaccine dosage intervals of 4 months or longer, regardless of the antigenicity of the exposed antigen, to maximize the breadth of serum cross-neutralization covering SARS-CoV-2 Omicron lineages.

2.
Glob Health Med ; 5(1): 5-14, 2023 Feb 28.
Artículo en Inglés | MEDLINE | ID: mdl-36865900

RESUMEN

As coronavirus disease 2019 (COVID-19) outbreaks in healthcare facilities are a serious public health concern, we performed a case-control study to investigate the risk of COVID-19 infection in healthcare workers. We collected data on participants' sociodemographic characteristics, contact behaviors, installation status of personal protective equipment, and polymerase chain reaction testing results. We also collected whole blood and assessed seropositivity using the electrochemiluminescence immunoassay and microneutralization assay. In total, 161 (8.5%) of 1,899 participants were seropositive between August 3 and November 13, 2020. Physical contact (adjusted odds ratio 2.4, 95% confidence interval 1.1-5.6) and aerosol-generating procedures (1.9, 1.1-3.2) were associated with seropositivity. Using goggles (0.2, 0.1-0.5) and N95 masks (0.3, 0.1-0.8) had a preventive effect. Seroprevalence was higher in the outbreak ward (18.6%) than in the COVID-19 dedicated ward (1.4%). Results showed certain specific risk behaviors of COVID-19; proper infection prevention practices reduced these risks.

3.
Med ; 3(6): 406-421.e4, 2022 06 10.
Artículo en Inglés | MEDLINE | ID: mdl-35815933

RESUMEN

BACKGROUND: The Omicron variant of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) was identified in Japan in November 2021. This variant contains up to 36 mutations in the spike protein, the target of neutralizing antibodies, and can escape vaccine-induced immunity. A booster vaccination campaign began with healthcare workers and high-risk groups. The safety and immunogenicity of the three-dose vaccination against Omicron remain unknown. METHODS: A total of 272 healthcare workers were initially evaluated for long-term vaccine safety and immunogenicity. We further established a vaccinee panel to evaluate the safety and immunogenicity against variants of concern (VOCs), including the Omicron variants, using a live virus microneutralization assay. FINDINGS: Two-dose vaccination induced robust anti-spike antibodies and neutralization titers (NTs) against the ancestral strain WK-521, whereas NTs against VOCs were significantly lower. Within 93-247 days of the second vaccine dose, NTs against Omicron were completely abolished in up to 80% of individuals in the vaccinee panel. Booster dose induced a robust increase in anti-spike antibodies and NTs against the WK-521, Delta, and Omicron variants. There were no significant differences in the neutralization ability of sera from boosted individuals among the Omicron subvariants BA.1, BA.1.1, and BA.2. Boosting increased the breadth of humoral immunity and cross-reactivity with Omicron without changes in cytokine signatures and adverse event rate. CONCLUSIONS: The third vaccination dose is safe and increases neutralization against Omicron variants. FUNDING: This study was supported by grants from AMED (grants JP21fk0108104 and JP21mk0102146).


Asunto(s)
Anticuerpos Antivirales , Vacuna BNT162 , COVID-19 , Inmunización Secundaria , Inmunogenicidad Vacunal , Anticuerpos Neutralizantes , Vacuna BNT162/inmunología , COVID-19/prevención & control , Reacciones Cruzadas , Humanos , Inmunidad Humoral , Pruebas de Neutralización , ARN Mensajero , SARS-CoV-2/genética
4.
Med ; 3(4): 249-261.e4, 2022 04 08.
Artículo en Inglés | MEDLINE | ID: mdl-35261995

RESUMEN

Background: The immune profile against severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has dramatically diversified due to a complex combination of exposure to vaccines and infection by various lineages/variants, likely generating a heterogeneity in protective immunity in a given population. To further complicate this, the Omicron variant, with numerous spike mutations, has emerged. These circumstances have created the need to assess the potential of immune evasion by Omicron in individuals with various immune histories. Methods: The neutralization susceptibility of the variants, including Omicron and their ancestors, was comparably assessed using a panel of plasma/serum derived from individuals with divergent immune histories. Blood samples were collected from either mRNA vaccinees or from those who suffered from breakthrough infections of Alpha/Delta with multiple time intervals following vaccination. Findings: Omicron was highly resistant to neutralization in fully vaccinated individuals without a history of breakthrough infections. In contrast, robust cross-neutralization against Omicron was induced in vaccinees that experienced breakthrough infections. The time interval between vaccination and infection, rather than the variant types of infection, was significantly correlated with the magnitude and potency of Omicron-neutralizing antibodies. Conclusions: Immune histories with breakthrough infections can overcome the resistance to infection by Omicron, with the vaccination-infection interval being the key determinant of the magnitude and breadth of neutralization. The diverse exposure history in each individual warrants a tailored and cautious approach to understanding population immunity against Omicron and future variants. Funding: This study was supported by grants from the Japan Agency for Medical Research and Development (AMED).


Asunto(s)
COVID-19 , SARS-CoV-2 , Anticuerpos Antivirales , Vacuna BNT162 , Vacunas contra la COVID-19 , Humanos , Complicaciones Posoperatorias , Vacunación
5.
Immunity ; 54(8): 1841-1852.e4, 2021 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-34246326

RESUMEN

Antibody titers against SARS-CoV-2 slowly wane over time. Here, we examined how time affects antibody potency. To assess the impact of antibody maturation on durable neutralizing activity against original SARS-CoV-2 and emerging variants of concern (VOCs), we analyzed receptor binding domain (RBD)-specific IgG antibodies in convalescent plasma taken 1-10 months after SARS-CoV-2 infection. Longitudinal evaluation of total RBD IgG and neutralizing antibody revealed declining total antibody titers but improved neutralization potency per antibody to original SARS-CoV-2, indicative of antibody response maturation. Neutralization assays with authentic viruses revealed that early antibodies capable of neutralizing original SARS-CoV-2 had limited reactivity toward B.1.351 (501Y.V2) and P.1 (501Y.V3) variants. Antibodies from late convalescents exhibited increased neutralization potency to VOCs, suggesting persistence of cross-neutralizing antibodies in plasma. Thus, maturation of the antibody response to SARS-CoV-2 potentiates cross-neutralizing ability to circulating variants, suggesting that declining antibody titers may not be indicative of declining protection.


Asunto(s)
Anticuerpos Neutralizantes/inmunología , Anticuerpos Antivirales/inmunología , COVID-19/inmunología , COVID-19/virología , SARS-CoV-2/inmunología , Anticuerpos Monoclonales/inmunología , Especificidad de Anticuerpos , COVID-19/epidemiología , Humanos , Inmunoglobulina G , Pruebas de Neutralización , SARS-CoV-2/genética , Carga Viral
6.
Biologicals ; 46: 68-73, 2017 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-28162840

RESUMEN

Aggregates of human plasma-derived intravenous immunoglobulins (IVIGs) carries a risk of severe adverse events after nonspecific complement activation induced in humans administrated. Therefore, the anti-complementary activity (ACA) test is legally required in every batch of IVIGs in Japan. However, due to the intrinsic nature of this bioassay, there might be large differences in the results of ACA tests from laboratories, even when the same batch of IVIGs was measured. Our six laboratories evaluated whether there were such differences and argued for establishment of a reference material (RM) for standardization of the ACA test. Our results revealed inter-laboratory differences in ACA values, indicating a need to establish an RM. Therefore, after ACA values in candidate RMs were measured collaboratively, one RM was selected from two candidates and unit value-assigned. The RM in fact normalized the ACA test values for samples measured in parallel at almost all the laboratories, when the values were calculated relative to the assigned unit value of the RM. Thus, we established a first RM to standardize the ACA test in Japan, which enabled each laboratory to normalize ACA values constantly for IVIGs. This indicates that the establishment of an RM can contribute to quality control of IVIGs.


Asunto(s)
Activación de Complemento/efectos de los fármacos , Inactivadores del Complemento/farmacología , Inmunoglobulinas Intravenosas/farmacología , Animales , Bioensayo/métodos , Bioensayo/normas , Calibración , Inactivadores del Complemento/normas , Conducta Cooperativa , Cobayas , Humanos , Inmunoglobulinas Intravenosas/normas , Japón , Laboratorios/normas , Control de Calidad , Estándares de Referencia , Reproducibilidad de los Resultados , Ovinos
7.
Transfusion ; 56(12): 3094-3100, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27774649

RESUMEN

BACKGROUND: Dengue fever is caused by four related RNA viruses of the genus Flavivirus, dengue virus (DENV)-1, -2, -3, and -4, which are transmitted to humans by mosquitoes. Although DENV is not endemic in Japan, an autochthonous dengue outbreak occurred in 2014. Several transfusion-transmitted cases have also been reported after the use of blood and plasma products in DENV-endemic countries. The aim of this study was to develop a novel multiplex reverse transcription-polymerase chain reaction (RT-PCR) assay for DENV blood screening. STUDY DESIGN AND METHODS: Large-scale oligonucleotide screening was performed to obtain DENV-specific primers and probes using a variety of DENV clinical isolates. A multiplex RT-PCR assay was then developed using the identified oligonucleotides and the ability of this assay to detect DENV RNA was evaluated. RESULTS: A number of oligonucleotides suitable for DENV RNA detection were identified and a novel DENV serotype-specific multiplex RT-PCR assay was successfully established. Comparative analysis revealed that the multiplex assay could detect levels of viral contamination as low as 100 viral copies/mL. CONCLUSION: This established serotype-specific multiplex RT-PCR assay provides a simple, sensitive, and quantitative detection method for DENV, which could be applied in the screening of blood samples to prevent transfusion-transmitted DENV infection.


Asunto(s)
Virus del Dengue/genética , Dengue/diagnóstico , Reacción en Cadena de la Polimerasa/métodos , Serogrupo , Reacción a la Transfusión , Seguridad de la Sangre , Dengue/prevención & control , Dengue/transmisión , Humanos , Reacción en Cadena de la Polimerasa Multiplex , ARN Viral/análisis , ARN Viral/sangre , Reacción en Cadena en Tiempo Real de la Polimerasa
8.
J Biosci Bioeng ; 115(1): 104-10, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-22925901

RESUMEN

In the pharmaceutical industry, analysis of soluble aggregates in pharmaceutical formulations is most commonly performed using size-exclusion chromatography (SEC). However, owing to concerns that aggregates can be overlooked by SEC analysis, it has been suggested that its results should be confirmed with orthogonal methods. One of the main alternative methods for SEC is analytical ultracentrifugation sedimentation velocity (AUC-SV), which has been indicated as an important tool for the measurement of protein aggregation. The present study aimed to show that AUC-SV can be effectively applied for the characterization of marketed immunoglobulin pharmaceutical preparations to support the results obtained by SEC. In addition, the present research aimed to assess the appropriateness of two integration approaches for the quantitative analysis of the SEC results. Thus, the aggregates were measured in seven different preparations of human immunoglobulins by AUC-SV and SEC, and the acquired chromatographic data were processed by using either the vertical drop method or the Gaussian skim approach, implemented in the Empower II chromatography data software (Waters, Tokyo, Japan). The results of aggregation measurements performed using AUC-SV were in good agreement with those obtained using SEC. As expected, the Gaussian skim integration approach inherently provided lower estimates of aggregation content than the results of the vertical drop method. The finding of this study confirmed the complementary nature of AUC-SV to SEC for aggregate composition analysis and underscored the important role that the different integration methods can play in the quantitative interpretation of chromatographic results.


Asunto(s)
Cromatografía en Gel , Inmunoglobulinas/análisis , Inmunoglobulinas/química , Liofilización , Humanos , Inmunoglobulinas/aislamiento & purificación , Reproducibilidad de los Resultados , Programas Informáticos , Ultracentrifugación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...