Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Brain Topogr ; 35(3): 322-336, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35262840

RESUMEN

Most of the motor mapping procedures using navigated transcranial magnetic stimulation (nTMS) follow the conventional somatotopic organization of the primary motor cortex (M1) by assessing the representation of a particular target muscle, disregarding the possible coactivation of synergistic muscles. In turn, multiple reports describe a functional organization of the M1 with an overlapping among motor representations acting together to execute movements. In this context, the overlap degree among cortical representations of synergistic hand and forearm muscles remains an open question. This study aimed to evaluate the muscle coactivation and representation overlapping common to the grasping movement and its dependence on the stimulation parameters. The nTMS motor maps were obtained from one carpal muscle and two intrinsic hand muscles during rest. We quantified the overlapping motor maps in size (area and volume overlap degree) and topography (similarity and centroid Euclidean distance) parameters. We demonstrated that these muscle representations are highly overlapped and similar in shape. The overlap degrees involving the forearm muscle were significantly higher than only among the intrinsic hand muscles. Moreover, the stimulation intensity had a stronger effect on the size compared to the topography parameters. Our study contributes to a more detailed cortical motor representation towards a synergistic, functional arrangement of M1. Understanding the muscle group coactivation may provide more accurate motor maps when delineating the eloquent brain tissue during pre-surgical planning.


Asunto(s)
Corteza Motora , Mapeo Encefálico/métodos , Potenciales Evocados Motores/fisiología , Antebrazo/fisiología , Mano , Humanos , Corteza Motora/fisiología , Músculo Esquelético/fisiología , Estimulación Magnética Transcraneal/métodos
2.
Materials (Basel) ; 14(22)2021 Nov 19.
Artículo en Inglés | MEDLINE | ID: mdl-34832426

RESUMEN

The active development of the power electronics market and a constant increase in the prices of components require new materials and approaches, including a power module packaging technology. The use of aluminum instead of copper in the power module baseplate is an interesting and promising solution. The insulated metal baseplate is one of the most extensively developed technologies nowadays. The object of this study is an insulated metal substrate based on anodized aluminum. The main goal of the article is the comparison of copper topology adhesion to an anodized aluminum oxide layer formed on different aluminum alloys with aluminum content of at least 99.3 wt %. Peel test and pull-off adhesions showed a twofold difference for both aluminum alloys. The high ordered defect-free anodized alumina formed on alloys with copper content of 0.06 wt % had a mean pull-off adhesion of 27 N/mm2 and hardness of 489 HV. In the case of the alloy with copper content of around 0.15 wt %, it had hardness of 295 HV and a mean pull-off adhesion of 12 N/mm2. The results of our microstructure investigation showed that anodized alumina based on alloys with copper content of around 0.15 wt % is fragile due to spherical holes. Summing up the results, it can be concluded that not all initial impurities are critical for anodized alumina, but some, specifically copper, dramatically decreased the mechanical properties of anodized alumina.

3.
PLoS One ; 16(9): e0257554, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34550997

RESUMEN

Besides stimulus intensities and interstimulus intervals (ISI), the electric field (E-field) orientation is known to affect both short-interval intracortical inhibition (SICI) and facilitation (SICF) in paired-pulse transcranial magnetic stimulation (TMS). However, it has yet to be established how distinct orientations of the conditioning (CS) and test stimuli (TS) affect the SICI and SICF generation. With the use of a multi-channel TMS transducer that provides electronic control of the stimulus orientation and intensity, we aimed to investigate how changes in the CS and TS orientation affect the strength of SICI and SICF. We hypothesized that the CS orientation would play a major role for SICF than for SICI, whereas the CS intensity would be more critical for SICI than for SICF. In eight healthy subjects, we tested two ISIs (1.5 and 2.7 ms), two CS and TS orientations (anteromedial (AM) and posteromedial (PM)), and four CS intensities (50, 70, 90, and 110% of the resting motor threshold (RMT)). The TS intensity was fixed at 110% RMT. The intensities were adjusted to the corresponding RMT in the AM and PM orientations. SICI and SICF were observed in all tested CS and TS orientations. SICI depended on the CS intensity in a U-shaped manner in any combination of the CS and TS orientations. With 70% and 90% RMT CS intensities, stronger PM-oriented CS induced stronger inhibition than weaker AM-oriented CS. Similar SICF was observed for any CS orientation. Neither SICI nor SICF depended on the TS orientation. We demonstrated that SICI and SICF could be elicited by the CS perpendicular to the TS, which indicates that these stimuli affected either overlapping or strongly connected neuronal populations. We concluded that SICI is primarily sensitive to the CS intensity and that CS intensity adjustment resulted in similar SICF for different CS orientations.


Asunto(s)
Potenciales Evocados Motores/fisiología , Inhibición Neural/fisiología , Estimulación Magnética Transcraneal/métodos , Adulto , Electromiografía , Voluntarios Sanos , Humanos , Masculino , Corteza Motora/fisiología , Adulto Joven
4.
Stroke ; 52(1): 241-249, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33317414

RESUMEN

BACKGROUND AND PURPOSE: Despite continuing efforts in the multimodal assessment of the motor system after stroke, conclusive findings on the complementarity of functional and structural metrics of the ipsilesional corticospinal tract integrity and the role of the contralesional hemisphere are still lacking. This research aimed to find the best combination of motor system metrics, allowing the classification of patients into 3 predefined groups of upper limb motor recovery. METHODS: We enrolled 35 chronic ischemic stroke patients (mean 47 [26-66] years old, 29 [6-58] months poststroke) with a single supratentorial lesion and unilateral upper extremity weakness. Patients were divided into 3 groups, depending on upper limb motor recovery: good, moderate, and bad. Nonparametric statistical tests and regression analysis were used to investigate the relationships among microstructural (fractional anisotropy (FA) ratio of the corticospinal tracts at the internal capsule (IC) level (classic method) and along the length of the tracts (Fréchet distance), and of the corpus callosum) and functional (motor evoked potentials [MEPs] for 2 hand muscles) motor system metrics. Stratification rules were also tested using a decision tree classifier. RESULTS: IC FA ratio in the IC and MEP absence were both equally discriminative of the bad motor outcome (96% accuracy). For the 3 recovery groups' classification, the best parameter combination was IC FA ratio and the Fréchet distance between the contralesional and ipsilesional corticospinal tract FA profiles (91% accuracy). No other metrics had any additional value for patients' classification. MEP presence differed for 2 investigated muscles. CONCLUSIONS: This study demonstrates that better separation between 3 motor recovery groups may be achieved when considering the similarity between corticospinal tract FA profiles along its length in addition to region of interest-based assessment and lesion load calculation. Additionally, IC FA ratio and MEP absence are equally important markers for poor recovery, while for MEP probing it may be important to investigate more than one hand muscle.


Asunto(s)
Accidente Cerebrovascular Isquémico/fisiopatología , Trastornos del Movimiento/fisiopatología , Adulto , Anciano , Anisotropía , Enfermedad Crónica , Imagen de Difusión Tensora , Potenciales Evocados Motores , Femenino , Lateralidad Funcional , Humanos , Accidente Cerebrovascular Isquémico/complicaciones , Accidente Cerebrovascular Isquémico/diagnóstico por imagen , Imagen por Resonancia Magnética , Masculino , Persona de Mediana Edad , Trastornos del Movimiento/diagnóstico por imagen , Trastornos del Movimiento/etiología , Debilidad Muscular/etiología , Debilidad Muscular/fisiopatología , Desempeño Psicomotor , Tractos Piramidales/diagnóstico por imagen , Tractos Piramidales/fisiopatología , Recuperación de la Función , Extremidad Superior/fisiopatología
5.
Front Hum Neurosci ; 12: 239, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-30038562

RESUMEN

The use of the MRI-navigation system ensures accurate targeting of TMS. This, in turn, results in TMS motor mapping becoming a routinely used procedure in neuroscience and neurosurgery. However, currently, there is no standardized methodology for assessment of TMS motor-mapping results. Therefore, we developed TMSmap-free standalone graphical interface software for the quantitative analysis of the TMS motor mapping results (http://tmsmap.ru/). In addition to the estimation of standard parameters (such as the size of cortical muscle representation and the center of gravity location), it allows estimation of the volume of cortical representations, excitability profile of the cortical surface map, and the overlap between cortical representations. The input data for the software includes the coordinates of the coil position (or electric field maximum) and the corresponding response in each stimulation point. TMSmap has been developed for versatile assessment and comparison of TMS maps relating to different experimental interventions including, but not limited to longitudinal, pharmacological and clinical studies (e.g., stroke recovery). To illustrate the use of TMSmap we provide examples of the actual TMS motor-mapping analysis of two healthy subjects and one chronic stroke patient.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...