Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Nat Commun ; 14(1): 6396, 2023 Oct 12.
Artículo en Inglés | MEDLINE | ID: mdl-37828042

RESUMEN

Quantum noise reduction and entanglement-enhanced sensing in the acoustic frequency range is an outstanding challenge relevant for a number of applications including magnetometry and broadband noise reduction in gravitational wave detectors. Here we experimentally demonstrate quantum behavior of a macroscopic atomic spin oscillator in the acoustic frequency range. Quantum back-action of the spin measurement, ponderomotive squeezing of light, and virtual spring softening are observed at oscillation frequencies down to the sub-kHz range. Quantum noise sources characteristic of spin oscillators operating in the near-DC frequency range are identified and means for their mitigation are presented.

2.
Nat Commun ; 13(1): 4815, 2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-35974049

RESUMEN

We report a high-purity Einstein-Podolsky-Rosen (EPR) state between light modes with the wavelengths separated by more than 200 nm. We demonstrate highly efficient EPR-steering between the modes with the product of conditional variances [Formula: see text]. The modes display - 7.7 ± 0.5 dB of two-mode squeezing and an overall state purity of 0.63 ± 0.16. EPR-steering is observed over five octaves of sideband frequencies from RF down to audio-band. The demonstrated combination of high state purity, strong quantum correlations, and extended frequency range enables new matter-light quantum protocols.

3.
Opt Express ; 28(3): 3975-3984, 2020 Feb 03.
Artículo en Inglés | MEDLINE | ID: mdl-32122057

RESUMEN

We report on double-resonant highly efficient sum-frequency generation in the blue range. The system consists of a 10-mm-long periodically poled KTP crystal placed in a double-resonant bow-tie cavity and pumped by a fiber laser at 1064.5 nm and a Ti:sapphire laser at 849.2 nm. An optical power of 375 mW at 472.4 nm in a TEM00 mode was generated with pump powers of 250 mW at 849.2 nm and 200 mW at 1064.5 nm coupled into the double-resonant ring resonator with 88% mode-matching. The resulting internal conversion efficiency of 95(±3)% of the photons mode-matched to the cavity constitutes, to the best of our knowledge, the highest overall achieved quantum conversion efficiency using continuous-wave pumping. Very high conversion efficiency is rendered possible due to very low intracavity loss on the level of 0.3% and high nonlinear conversion coefficient up to 0.045(0.015) W-1. Power stability measurements performed over one hour show a stability of 0.8%. The generated blue light can be tuned within 5 nm around the center wavelength of 472.4 nm, limited by the phase-matching of our nonlinear crystal. This can however be expanded to cover the entire blue spectrum (420 nm to 510 nm) by proper choice of nonlinear crystals and pump lasers. Our experimental results agree very well with analytical and numerical simulations taking into account cavity impedance matching and depletion of the pump fields.

4.
J Funct Biomater ; 10(3)2019 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-31252637

RESUMEN

Repairs of orbital post-traumatic and extensive malignant defects remain a major surgical challenge, in view of follow-up outcomes. Incorrect surgical management of injured facial structures results in cosmetic, ophthalmic, and social aftereffects. A custom-made knitted TiNi-based mesh (KTNM) endograft was employed to overcome post-surgical complications and post-resected lesions of the orbital area. Preoperative high-resolution computed tomography (CT) imaging and CAD modelling were used to design the customized KTNM in each case. Twenty-five patients underwent surgery utilizing the suggested technique, from 2014 to 2019. In all documented cases, resolution of the ophthalmic malfunction was noted in the early period. Follow-up observation evidenced no relapsed enophthalmos, hypoglobus, or diplopia as late complications. The findings emanating from our clinical observations allow us to claim that the KTNM indicated a high level of biocompatibility. It is simply modified intraoperatively to attach any desired shape/size for implantation and can also be screw-fixed, providing a good supporting ability. The KTNM precisely renders orbitozygomatic outlines and orbital floor, thus recovering the anatomical structure, and is regarded as an attractive alternative to Ti-based meshes and plates. Additionally, we report one of the studied cases, where good functional and cosmetic outcomes have been achieved.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...