Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Appl Microbiol ; 109(6): 2200-5, 2010 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21040269

RESUMEN

AIMS: Studies to date have shown rapid killing of bacterial cells when exposed to copper surfaces. The mechanistic action of copper on bacterial cells is so far unknown. METHODS AND RESULTS: To investigate potential mechanisms involved, meticillin-resistant Staphylococcus aureus (MRSA) cells (10(7) CFU) were inoculated onto coupons of copper or stainless steel and stained with either the viability fluorophore 5-cyano-2,3-ditolyl tetrazolium (CTC), to detect respiration, or BacLight™ (SYTO9/propidium iodide), to determine cell wall integrity. Coupons were then observed in-situ using epifluorescence microscopy. In addition, DNA from cells inoculated onto either copper or stainless steel surfaces was isolated and analysed by agarose gel electrophoresis. An effect on cellular respiration with CTC reduction was evident but no effect on cell membrane integrity (BacLight™) was observed. Results from the DNA isolation indicated a copper-induced detrimental effect on MRSA genomic material as no bands were observed after exposure to copper surface. CONCLUSIONS: The results indicate that exposure to copper surfaces rapidly kills MRSA by compromising cellular respiration and damaging DNA, with little effect on cell membrane integrity. SIGNIFICANCE AND IMPACT OF THE STUDY: This research provides a mechanistic explanation in support of previous suggestions that although copper surfaces do not affect membrane integrity of cells, there is still a rapid antimicrobial effect.


Asunto(s)
Cobre/farmacología , Staphylococcus aureus Resistente a Meticilina/efectos de los fármacos , Antibacterianos/farmacología , Membrana Celular/efectos de los fármacos , Recuento de Colonia Microbiana , Daño del ADN , ADN Bacteriano/efectos de los fármacos , Electroforesis en Gel de Agar , Microscopía Fluorescente , Acero Inoxidable/farmacología
2.
Lett Appl Microbiol ; 49(2): 191-5, 2009 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-19413757

RESUMEN

AIMS: To compare silver and copper, metals with known antimicrobial properties, by evaluating the effects of temperature and humidity on efficacy by challenging with methicillin resistant Staphylococcus aureus (MRSA). METHODS AND RESULTS: Using standard methodology described in a globally used Japanese Industrial Standard, JIS Z 2801, a silver ion-containing material exhibited >5 log reduction in MRSA viability after 24 h at >90% relative humidity (RH) at 20 degrees C and 35 degrees C but only a <0.3 log at approximately 22% RH and 20 degrees C and no reduction at approximately 22% RH and 35 degrees C. Copper alloys demonstrated >5 log reductions under all test conditions. CONCLUSIONS: While the high humidity (>90% RH) and high temperature (35 degrees C) utilized in JIS Z 2801 produce measurable efficacy in a silver ion-containing material, it showed no significant response at lower temperature and humidity levels typical of indoor environments. SIGNIFICANCE AND IMPACT OF THE STUDY: The high efficacy levels displayed by the copper alloys, at temperature and humidity levels typical of indoor environments, compared to the low efficacy of the silver ion-containing material under the same conditions, favours the use of copper alloys as antimicrobial materials in indoor environments such as hospitals.


Asunto(s)
Antibacterianos/farmacología , Cobre/farmacología , Humedad , Staphylococcus aureus Resistente a Meticilina/crecimiento & desarrollo , Plata/farmacología , Temperatura , Recuento de Colonia Microbiana , Viabilidad Microbiana/efectos de los fármacos
3.
Appl Environ Microbiol ; 73(8): 2748-50, 2007 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-17259354

RESUMEN

Influenza A virus particles (2 x 10(6)) were inoculated onto copper or stainless steel and incubated at 22 degrees C at 50 to 60% relative humidity. Infectivity of survivors was determined by utilizing a defined monolayer with fluorescent microscopy analysis. After incubation for 24 h on stainless steel, 500,000 virus particles were still infectious. After incubation for 6 h on copper, only 500 particles were active.


Asunto(s)
Cobre , Subtipo H1N1 del Virus de la Influenza A/fisiología , Viabilidad Microbiana , Acero Inoxidable , Inactivación de Virus , Microscopía Fluorescente
4.
Appl Environ Microbiol ; 72(6): 4239-44, 2006 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-16751537

RESUMEN

The most notable method of infection from Escherichia coli O157 (E. coli O157) is through contaminated food products, usually ground beef. The objective of this study was to evaluate seven cast copper alloys (61 to 95% Cu) for their ability to reduce the viability of E. coli O157, mixed with or without ground beef juice, and to compare these results to those for stainless steel. E. coli O157 (NCTC 12900) (2 x 10(7) CFU) mixed with extracted beef juice (25%) was inoculated onto coupons of each copper cast alloy or stainless steel and incubated at either 22 degrees C or 4 degrees C for up to 6 h. E. coli O157 viability was determined by plate counts in addition to staining in situ with the respiratory indicator fluorochrome 5-cyano-2,3-ditolyl tetrazolium. Without beef extract, three alloys completely killed the inoculum during the 6-h exposure at 22 degrees C. At 4 degrees C, only the high-copper alloys (>85%) significantly reduced the numbers of O157. With beef juice, only one alloy (95% Cu) completely killed the inoculum at 22 degrees C. For stainless steel, no significant reduction in cell numbers occurred. At 4 degrees C, only alloys C83300 (93% Cu) and C87300 (95% Cu) significantly reduced the numbers of E. coli O157, with 1.5- and 5-log kills, respectively. Reducing the inoculum to 10(3) CFU resulted in a complete kill for all seven cast copper alloys in 20 min or less at 22 degrees C. These results clearly demonstrate the antimicrobial properties of cast copper alloys with regard to E. coli O157, and consequently these alloys have the potential to aid in food safety.


Asunto(s)
Aleaciones/farmacología , Cobre/farmacología , Escherichia coli O157/crecimiento & desarrollo , Contaminación de Alimentos/prevención & control , Manipulación de Alimentos , Animales , Escherichia coli O157/efectos de los fármacos , Cinética , Carne/microbiología , Metales/farmacología
5.
J Hosp Infect ; 63(3): 289-97, 2006 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-16650507

RESUMEN

Epidemic meticillin-resistant Staphylococcus aureus (EMRSA) emerged in the early 1980s with EMRSA-15 and -16 being the most prevalent strains within the UK. MRSA transmission between patients is largely via the hands of healthcare workers, and contamination of the hospital environment may occur. The objective of this study was to evaluate the effectiveness of copper and brass to reduce the viability of air-dried deposits of three MRSA strains [MRSA (NCTC 10442), EMRSA-1 (NCTC 11939) and EMRSA-16 (NCTC 13143)] compared with stainless steel. MRSA and EMRSA [10(7)colony-forming units (CFU)] were inoculated on to coupons (1 cm x 1 cm) of copper, brass or stainless steel and incubated at either 22 degrees C or 4 degrees C for various time periods. Viability was determined by resuspending removed CFUs and plating out on tryptone soy agar plates in addition to staining with the respiratory indicator fluorochrome 5-cyano-2,3-ditolyl tetrazolium. On pure copper surfaces, 10(7) MRSA, EMRSA-1 and EMRSA-16 were completely killed after 45, 60 and 90 min, respectively, at 22 degrees C. In contrast, viable organisms for all three strains were detected on stainless steel (grade 304) after 72 h at 22 degrees C. At 4 degrees C, complete kill was achieved on copper for all three strains within 6 h. The results demonstrate an antimicrobial effect of copper on MRSA, EMRSA-1 and -16 in contrast to stainless steel. Consequently, the contemporary application of stainless steel in hospital environments for work surfaces and door furniture is not recommended.


Asunto(s)
Cobre/farmacología , Resistencia a la Meticilina/efectos de los fármacos , Acero Inoxidable/farmacología , Staphylococcus aureus/crecimiento & desarrollo , Zinc/farmacología , Recuento de Colonia Microbiana , Contaminación de Equipos , Humanos , Epidemiología Molecular , Infecciones Estafilocócicas
6.
Aust Clin Rev ; 12(1): 15-21, 1992.
Artículo en Inglés | MEDLINE | ID: mdl-1586291

RESUMEN

In this paper the authors look at the proactive role performance indicators can and should play in managing for quality in health care facilities. In particular, they highlight the use of clinical indicators as a means of providing evidence of value-for-money and best quality delivery of care. The argument is presented that management can no longer ignore indicators as a quality assurance tool and an important component of managing for quality over time. The authors demonstrate where indicators fit into the traditional quality assurance cycle and describe strategies for analysing problems and setting priorities. They also argue that managers need to invest in management information systems in order to provide the data needed for performance monitoring. Accurate and complete indicator data are needed if the goals of quality management and optimal quality of care are to be achieved.


Asunto(s)
Evaluación de Procesos y Resultados en Atención de Salud , Garantía de la Calidad de Atención de Salud/normas , Evaluación del Rendimiento de Empleados , Instituciones de Salud/normas , Administración de Instituciones de Salud , Objetivos Organizacionales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA