bioRxiv ; 2023 Nov 28.
Artículo en Inglés | MEDLINE | ID: mdl-38076994

RESUMEN

Prostate cancer (PCa) is known as one of the most prevalent and fatal cancer types. This report describes an MRI-compatible photoacoustic/ultrasound (PA/US) imaging platform to improve the diagnosis of PCa. In the proposed solution, PA imaging, which offers real-time, non-ionizing imaging with high sensitivity and specificity, is combined with MRI, aiming to overcome PA's limited field of view (FOV) and make PA scalable for translation to clinical settings. Central to the design of the system is a reflector-based transrectal probing mechanism composed of MRI-compatible materials. The linear transducer with a center hole for optical fiber delivery can be mechanically actuated to form a multi-angled scan, allowing PA/US imaging from varied cross-sectional views. Performance assessment was carried out in phantom and ex-vivo settings. We confirmed the MRI compatibility of the system and demonstrated the feasibility of its tri-modal imaging capability by visualizing a tubing phantom containing contrast agents. The ex-vivo evaluation of targeted tumor imaging capability was performed with a mouse liver sample expressing PSMA-positive tumors, affirming the system's compatibility in spectroscopic PA (sPA) imaging with biological tissue. These results support the feasibility of the in-bore MRI-compatible transrectal PA and US and the potential clinical adaptability.

2.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 2864-2869, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36085874

RESUMEN

Neurological trauma, such as stroke, traumatic brain injury (TBI), spinal cord injury, and cerebral palsy can cause mild to severe upper limb impairments. Hand impairment makes it difficult for individuals to complete activities of daily living, especially bimanual tasks. A robotic hand orthosis or hand exoskeleton can be used to restore partial function of an intact but impaired hand. It is common for upper extremity prostheses and orthoses to use electromyography (EMG) sensing as a method for the user to control their device. However some individuals with an intact but impaired hand may struggle to use a myoelectrically controlled device due to potentially confounding muscle activity. This study was conducted to evaluate the application of conventional EMG control techniques as a robotic orthosis/exoskeleton user input method for individuals with mild to severe hand impairments. Nine impaired subjects and ten healthy subjects were asked to perform repeated contractions of muscles in their forearm and then onset analysis and feature classification were used to determine the accuracy of the employed EMG techniques. The average accuracy for contraction identification across employed EMG techniques was 95.4% ± 4.9 for the healthy subjects and 73.9% ± 13.1 for the impaired subjects with a range of 47.0% ± 19.1 - 91.6% ± 8.5. These preliminary results suggest that the conventional EMG control technologies employed in this paper may be difficult for some impaired individuals to use due to their unreliable muscle control.


Asunto(s)
Actividades Cotidianas , Dispositivos de Autoayuda , Electromiografía , Mano , Humanos , Extremidad Superior
3.
Int J Hyperthermia ; 39(1): 1283-1293, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36162814

RESUMEN

BACKGROUND: In stereotactic radiosurgery, isodose lines must be considered to determine how surrounding tissue is affected. In thermal ablative therapy, such as laser interstitial thermal therapy (LITT), transcranial MR-guided focused ultrasound (tcMRgFUS), and needle-based therapeutic ultrasound (NBTU), how the surrounding area is affected has not been well studied. OBJECTIVE: We aimed to quantify the transition zone surrounding the ablation core created by magnetic resonance-guided robotically-assisted (MRgRA) delivery of NBTU using multi-slice volumetric 2-D magnetic resonance thermal imaging (MRTI) and subsequent characterization of the resultant tissue damage using histopathologic analysis. METHODS: Four swine underwent MRgRA NBTU using varying duration and wattage for treatment delivery. Serial MRI images were obtained, and the most representative were overlaid with isodose lines and compared to brain tissue acquired postmortem which underwent histopathologic analysis. These results were also compared to predicted volumes using a finite element analysis model. Contralateral brain tissue was used for control data. RESULTS: Intraoperative MRTI thermal isodose contours were characterized and comprehensively mapped to post-operative MRI images and qualitatively compared with histological tissue sections postmortem. NBTU 360° ablations induced smaller lesion volumes (33.19 mm3; 120 s, 3 W; 30.05 mm3, 180 s, 4 W) versus 180° ablations (77.20 mm3, 120 s, 3 W; 109.29 mm3; 180 s; 4 W). MRTI/MRI overlay demonstrated the lesion within the proximal isodose lines. The ablation-zone was characterized by dense macrophage infiltration and glial/neuronal loss as demonstrated by glial fibrillary acidic protein (GFAP) and neurofilament (NF) absence and avid CD163 staining. The transition-zone between lesion and normal brain demonstrated decreased macrophage infiltration and measured ∼345 microns (n - 3). We did not detect overt hemorrhages or signs of edema in the adjacent spared tissue. CONCLUSION: We successfully performed MRgRA NBTU ablation in swine and demonstrated minimal histologic changes extended past the ablation-zone. The lesion was characterized by macrophage infiltration and glial/neuronal loss which decreased through the transition-zone.


Asunto(s)
Encéfalo , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Proteína Ácida Fibrilar de la Glía , Hígado , Imagen por Resonancia Magnética/métodos , Porcinos
4.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 4843-4848, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-36086516

RESUMEN

There is a large community of people with hand disabilities, and these disabilities can be a barrier to those looking to retain or pursue surgical careers. With the development of surgical robotics technologies, it may be possible to develop user interfaces to accommodate these individuals. This paper proposes a hand-free control method for the gripper of a patient side manipulator (PSM) in the da Vinci surgical system. Using electromyography (EMG) signals, a proportional control method was tested on its ability to grasp a pressure sensor. These preliminary results demonstrate that the user can reliably control the grasping motion of the da Vinci PSM using this system. There is a strong correlation between grasping force and normalized EMG signal (r= 0.874). Moreover, the gripper can generate a step grasping force output when feeding in a generated step signal. The results in this paper demonstrate the system integration of a research EMG system with the da Vinci surgical system and are a step towards developing accessible teleoperation systems for surgeons with disabilities. Hand-free control for remaining degrees of freedom in the PSM is under development using additional input from the motion capture system.


Asunto(s)
Fuerza de la Mano , Robótica , Electromiografía/métodos , Mano , Humanos , Extremidad Superior
5.
Int J Hyperthermia ; 38(1): 907-915, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34148489

RESUMEN

BACKGROUND: High-intensity focused ultrasound (HIFU) serves as a noninvasive stereotactic system for the ablation of brain metastases; however, treatments are limited to simple geometries and energy delivery is limited by the high acoustic attenuation of the calvarium. Minimally-invasive magnetic resonance-guided robotically-assisted (MRgRA) needle-based therapeutic ultrasound (NBTU) using multislice volumetric 2-D magnetic resonance thermal imaging (MRTI) overcomes these limitations and has potential to produce less collateral tissue damage than current methods. OBJECTIVE: To correlate multislice volumetric 2-D MRTI volumes with histologically confirmed regions of tissue damage in MRgRA NBTU. METHODS: Seven swine underwent a total of 8 frontal MRgRA NBTU lesions. MRTI ablation volumes were compared to histologic tissue damage on brain sections stained with 2,3,5-triphenyltetrazolium chloride (TTC). Bland-Altman analyses and correlation trends were used to compare MRTI and TTC ablation volumes. RESULTS: Data from the initial and third swine's ablations were excluded due to sub-optimal tissue staining. For the remaining ablations (n = 6), the limits of agreement between the MRTI and histologic volumes ranged from -0.149 cm3 to 0.252 cm3 with a mean difference of 0.052 ± 0.042 cm3 (11.1%). There was a high correlation between the MRTI and histology volumes (r2 = 0.831) with a strong linear relationship (r = 0.868). CONCLUSION: We used a volumetric MRTI technique to accurately track thermal changes during MRgRA NBTU in preparation for human trials. Improved volumetric coverage with MRTI enhanced our delivery of therapy and has far-reaching implications for focused ultrasound in the broader clinical setting.


Asunto(s)
Neoplasias Encefálicas , Ultrasonido Enfocado de Alta Intensidad de Ablación , Terapia por Ultrasonido , Animales , Encéfalo/diagnóstico por imagen , Encéfalo/cirugía , Neoplasias Encefálicas/diagnóstico por imagen , Neoplasias Encefálicas/cirugía , Imagen por Resonancia Magnética , Espectroscopía de Resonancia Magnética , Porcinos
6.
Int Symp Med Robot ; 20212021 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-35789074

RESUMEN

The adoption of robotic image-guided surgeries has enabled physicians to perform therapeutic and diagnostic procedures with less invasiveness and higher accuracy. One example is the MRI-guided stereotactic robotic-assisted surgery for conformal brain tumor ablation, where the robot is used to position and orient a thin probe to target a desired region within the brain. Requirements such as the remote center of motion and precise manipulation, impose the use of complex kinematic structures, which result in non-trivial workspaces in these robots. The lack of workspace visualization poses a challenge in selecting valid entry and target points during the surgical planning and navigation stage. In this paper, we present a surgical planning toolkit called the "NeuroPlan" for our MRI-compatible stereotactic neurosurgery robot developed as a module for 3D Slicer software. This toolkit streamlines the current surgical workflow by rendering and overlaying the robot's reachable workspace on the MRI image. It also assists with identifying the optimal entry point by segmenting the cranial burr hole volume and locating its center. We demonstrate the accuracy of the workspace rendering and burr hole parameter detection through both phantom and MR-images acquired from previously conducted animal studies.

7.
IEEE Trans Biomed Eng ; 68(6): 1838-1846, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-32924937

RESUMEN

The primary objective of cancer intervention is the selective removal of malignant cells while conserving surrounding healthy tissues. However, the accessibility, size and shape of the cancer can make achieving appropriate margins a challenge. One minimally invasive treatment option for these clinical cases is interstitial needle based therapeutic ultrasound (NBTU). In this work, we develop a finite element model (FEM) capable of simulating continuous rotation of a directional NBTU applicator. The developed model was used to simulate the thermal deposition for different rotation trajectories. The actual thermal deposition patterns for the simulated trajectories were then evaluated using magnetic resonance thermal imaging (MRTI) in a porcine skin gelatin phantom. An MRI-compatible robot was used to control the rotation motion profile of the physical NBTU applicator to match the simulated trajectory. The model showed agreement when compared to experimental measurements with Pearson correlation coefficients greater than 0.839 when comparing temperature fields within an area of 12.6 mm radius from the ultrasound applicator. The average temperature error along a 6.3 mm radius profile from the applicator was 1.27 °C. The model was able to compute 1 s of thermal deposition by the applicator in 0.2 s on average with a 0.1 mm spatial resolution and 0.5 s time steps. The developed simulation demonstrates performance suitable for real-time control which may enable robotically-actuated closed-loop conformal tumor ablation.


Asunto(s)
Imagen por Resonancia Magnética , Terapia por Ultrasonido , Animales , Fantasmas de Imagen , Rotación , Porcinos , Ultrasonografía
9.
Artículo en Inglés | MEDLINE | ID: mdl-32704623

RESUMEN

Intra-operative medical imaging based on magnetic resonance imaging (MRI) coupled with robotic manipulation of surgical instruments enables precise feedback-driven procedures. Electrically powered nonferromagnetic motors based on piezoelectric elements have shown to be well suited for MRI robots. However, even avoiding ferrous materials, the high metal content on commercially available motors still cause distortions to the magnetic fields. We construct semicustom piezoelectric actuators wherein the quantity of conductive material is minimized and demonstrate that the distortion issues can be partly addressed through substituting several of these components for plastic equivalents, while maintaining motor functionality. Distortion was measured by assessing the root-mean-squared (RMS) change in position of 49 centroid points in a 12.5 mm square grid of a gelatin-filled phantom. The metal motor caused a distortion of up to 4.91 mm versus 0.55 mm for the plastic motor. An additional signal-to-noise-ratio (SNR) drop between motor off and motor spinning of approximately 20% was not statistically different for metal versus plastic (p = 0.36).

10.
IEEE Trans Biomed Eng ; 67(10): 2990-2999, 2020 10.
Artículo en Inglés | MEDLINE | ID: mdl-32078530

RESUMEN

OBJECTIVE: Treatment of brain tumors requires high precision in order to ensure sufficient treatment while minimizing damage to surrounding healthy tissue. Ablation of such tumors using needle-based therapeutic ultrasound (NBTU) under real-time magnetic resonance imaging (MRI) can fulfill this need. However, the constrained space and strong magnetic field in the MRI bore restricts patient access limiting precise placement of the NBTU ablation tool. A surgical robot compatible with use inside the bore of an MRI scanner can alleviate these challenges. METHODS: We present preclinical trials of a robotic system for NBTU ablation of brain tumors under real-time MRI guidance. The system comprises of an updated robotic manipulator and corresponding control electronics, the NBTU ablation system and applications for planning, navigation and monitoring of the system. RESULTS: The robotic system had a mean translational and rotational accuracy of 1.39  ± 0.64 mm and 1.27 [Formula: see text] in gelatin phantoms and 3.13  ± 1.41 mm and 5.58 [Formula: see text] in 10 porcine trials while causing a maximum reduction in signal to noise ratio (SNR) of 10.3%. CONCLUSION: The integrated robotic system can place NBTU ablator at a desired target location in porcine brain and monitor the ablation in realtime via magnetic resonance thermal imaging (MRTI). SIGNIFICANCE: Further optimization of this system could result in a clinically viable system for use in human trials for various diagnostic or therapeutic neurosurgical interventions.


Asunto(s)
Procedimientos Quirúrgicos Robotizados , Robótica , Animales , Humanos , Imagen por Resonancia Magnética , Fantasmas de Imagen , Relación Señal-Ruido , Porcinos
11.
Tissue Eng Part A ; 25(17-18): 1251-1260, 2019 09.
Artículo en Inglés | MEDLINE | ID: mdl-30638142

RESUMEN

IMPACT STATEMENT: Self-assembled tissues have potential to serve both as implantable grafts and as tools for disease modeling and drug screening. For these applications, tissue production must ultimately be scaled-up and automated. Limited technologies exist for precisely manipulating self-assembled tissues, which are fragile early in culture. Here, we presented a method for automatically stacking self-assembled smooth muscle cell rings onto mandrels, using a custom-designed well plate and robotic punch system. Rings then fuse into tissue-engineered blood vessels (TEBVs). This is a critical step toward automating TEBV production that may be applied to other tubular tissues as well.


Asunto(s)
Ingeniería de Tejidos/métodos , Animales , Línea Celular , Células Cultivadas , Electroforesis en Gel de Agar , Músculo Liso Vascular/citología , Miocitos del Músculo Liso/citología , Polímeros/química , Ratas , Procedimientos Quirúrgicos Robotizados , Andamios del Tejido/química
12.
Artículo en Inglés | MEDLINE | ID: mdl-31363718

RESUMEN

Intra-operative medical imaging based on magnetic resonance imaging (MRI) coupled with robotic manipulation of surgical instruments enables precise feedback-driven procedures. Electrically powered non-ferromagnetic motors based on piezoelectric elements have shown to be well suited for MRI robots. However, even avoiding ferrous materials, the high metal content on commercially available motors still cause distortions to the magnetic fields. We construct semi-custom piezoelectric actuators wherein the quantity of conductive material is minimized and demonstrate that the distortion issues can be partly addressed through substituting several of these components for plastic equivalents, while maintaining motor functionality. Distortion was measured by assessing the RMS change in position of 49 centroid points in a 12.5mm square grid of a gelatin-filled phantom. The metal motor caused a distortion of up to 4.91mm versus 0.55mm for the plastic motor. An additional SNR drop between motor off and motor spinning of approximately 20% was not statistically different for metal versus plastic (p=0.36).

13.
Rep U S ; 2017: 1677-1684, 2017 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29696097

RESUMEN

The use of magnetic resonance imaging (MRI) for guiding robotic surgical devices has shown great potential for performing precisely targeted and controlled interventions. To fully realize these benefits, devices must work safely within the tight confines of the MRI bore without negatively impacting image quality. Here we expand on previous work exploring MRI guided robots for neural interventions by presenting the mechanical design and assessment of a device for positioning, orienting, and inserting an interstitial ultrasound-based ablation probe. From our previous work we have added a 2 degree of freedom (DOF) needle driver for use with the aforementioned probe, revised the mechanical design to improve strength and function, and performed an evaluation of the mechanism's accuracy and effect on MR image quality. The result of this work is a 7-DOF MRI robot capable of positioning a needle tip and orienting it's axis with accuracy of 1.37 ± 0.06mm and 0.79° ± 0.41°, inserting it along it's axis with an accuracy of 0.06 ± 0.07mm, and rotating it about it's axis to an accuracy of 0.77° ± 1.31°. This was accomplished with no significant reduction in SNR caused by the robot's presence in the MRI bore, ≤ 10.3% reduction in SNR from running the robot's motors during a scan, and no visible paramagnetic artifacts.

14.
Artículo en Inglés | MEDLINE | ID: mdl-26737143

RESUMEN

Robotic technology has recently been explored as a means to rehabilitate and assist individuals suffering from hemiparesis of their upper limbs. Robotic approaches allow for targeted rehabilitation routines which are more personalized and adaptable while providing quantitative measurements of patient outcomes. Development of these technologies into inherently safe and portable devices has the potential to extend the therapy outside of the clinical setting and into the patient's home with benefits to the cost and accessibility of care. To this end, a soft, cable actuated robotic glove and sleeve was designed, modeled, and constructed to provide assistance of finger and elbow movements in a way that mimics the biological function of the tendons. The resulting design increases safety through greater compliance as well as greater tolerance for misalignment with the user's skeletal frame over traditional rigid exoskeletons. Overall this design provides a platform to expand and study the concepts around soft robotic rehabilitation.


Asunto(s)
Dispositivo Exoesqueleto , Modelos Teóricos , Paresia/rehabilitación , Robótica/instrumentación , Tendones/fisiopatología , Extremidad Superior/fisiopatología , Diseño de Equipo , Humanos , Movimiento , Paresia/fisiopatología