Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 21
Filtrar
1.
Eye (Lond) ; 38(3): 537-544, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37670143

RESUMEN

PURPOSE: To validate a deep learning algorithm for automated intraretinal fluid (IRF), subretinal fluid (SRF) and neovascular pigment epithelium detachment (nPED) segmentations in neovascular age-related macular degeneration (nAMD). METHODS: In this IRB-approved study, optical coherence tomography (OCT) data from 50 patients (50 eyes) with exudative nAMD were retrospectively analysed. Two models, A1 and A2, were created based on gradings from two masked readers, R1 and R2. Area under the curve (AUC) values gauged detection performance, and quantification between readers and models was evaluated using Dice and correlation (R2) coefficients. RESULTS: The deep learning-based algorithms had high accuracies for all fluid types between all models and readers: per B-scan IRF AUCs were 0.953, 0.932, 0.990, 0.942 for comparisons A1-R1, A1-R2, A2-R1 and A2-R2, respectively; SRF AUCs were 0.984, 0.974, 0.987, 0.979; and nPED AUCs were 0.963, 0.969, 0.961 and 0.966. Similarly, the R2 coefficients for IRF were 0.973, 0.974, 0.889 and 0.973; SRF were 0.928, 0.964, 0.965 and 0.998; and nPED were 0.908, 0.952, 0.839 and 0.905. The Dice coefficients for IRF averaged 0.702, 0.667, 0.649 and 0.631; for SRF were 0.699, 0.651, 0.692 and 0.701; and for nPED were 0.636, 0.703, 0.719 and 0.775. In an inter-observer comparison between manual readers R1 and R2, the R2 coefficient was 0.968 for IRF, 0.960 for SRF, and 0.906 for nPED, with Dice coefficients of 0.692, 0.660 and 0.784 for the same features. CONCLUSIONS: Our deep learning-based method applied on nAMD can segment critical OCT features with performance akin to manual grading.


Asunto(s)
Aprendizaje Profundo , Degeneración Macular , Desprendimiento de Retina , Degeneración Macular Húmeda , Humanos , Tomografía de Coherencia Óptica/métodos , Estudios Retrospectivos , Líquido Subretiniano , Degeneración Macular/tratamiento farmacológico , Degeneración Macular Húmeda/diagnóstico por imagen , Degeneración Macular Húmeda/tratamiento farmacológico , Inhibidores de la Angiogénesis/uso terapéutico , Ranibizumab/uso terapéutico , Inyecciones Intravítreas
2.
Retina ; 43(3): 433-443, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36705991

RESUMEN

PURPOSE: To evaluate a prototype home optical coherence tomography device and automated analysis software for detection and quantification of retinal fluid relative to manual human grading in a cohort of patients with neovascular age-related macular degeneration. METHODS: Patients undergoing anti-vascular endothelial growth factor therapy were enrolled in this prospective observational study. In 136 optical coherence tomography scans from 70 patients using the prototype home optical coherence tomography device, fluid segmentation was performed using automated analysis software and compared with manual gradings across all retinal fluid types using receiver-operating characteristic curves. The Dice similarity coefficient was used to assess the accuracy of segmentations, and correlation of fluid areas quantified end point agreement. RESULTS: Fluid detection per B-scan had area under the receiver-operating characteristic curves of 0.95, 0.97, and 0.98 for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid, respectively. On a per volume basis, the values for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid were 0.997, 0.998, and 0.998, respectively. The average Dice similarity coefficient values across all B-scans were 0.64, 0.73, and 0.74, and the coefficients of determination were 0.81, 0.93, and 0.97 for intraretinal fluid, subretinal fluid, and subretinal pigment epithelium fluid, respectively. CONCLUSION: Home optical coherence tomography device images assessed using the automated analysis software showed excellent agreement to manual human grading.


Asunto(s)
Degeneración Macular , Degeneración Macular Húmeda , Humanos , Tomografía de Coherencia Óptica/métodos , Retina , Líquido Subretiniano , Programas Informáticos , Degeneración Macular/diagnóstico , Inhibidores de la Angiogénesis
3.
J Clin Med ; 11(16)2022 Aug 16.
Artículo en Inglés | MEDLINE | ID: mdl-36013010

RESUMEN

An objective method of early identification of people at risk of chemotherapy-induced peripheral neuropathy is needed to minimize long-term toxicity and maximize dose intensity. The aims of the study were to observe corneal nerve microstructure and corneal sensitivity changes and peripheral neuropathy in patients receiving oxaliplatin, and to determine its association with corneal parameters at different stages of treatment and assess utility as non-invasive markers to detect and monitor peripheral neuropathy. Twenty-three patients scheduled to receive oxaliplatin chemotherapy with intravenous 5-FU for gastro-intestinal cancer were recruited and followed up with for 12 months. Ocular examinations including corneal and retinal evaluations, alongside peripheral neuropathy assessment, were performed. The corneal nerve density did not show significant change after chemotherapy when measured with a widely used semi-automated program or an automated analysis technique. Macula and optic nerve function did not change during or after oxaliplatin chemotherapy. However, the corneal nerve density modestly correlated with clinical peripheral neuropathy after 20 weeks of chemotherapy (r = 0.61, p = 0.01) when peripheral neuropathy is typical most profound, and corneal nerve sensitivity correlated with neuropathy at 12 (r = 0.55, p = 0.01) and 20 weeks (r = 0.64, p = 0.006). In conclusion, corneal changes detected on confocal microscopy show moderate association with peripheral neuropathy, indicating their potential to identify the development of oxaliplatin-induced peripheral neuropathy. However, further studies are required to confirm these findings.

4.
Ophthalmic Surg Lasers Imaging Retina ; 53(4): 208-214, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-35417293

RESUMEN

BACKGROUND AND OBJECTIVE: To determine whether an automated artificial intelligence (AI) model could assess macular hole (MH) volume on swept-source optical coherence tomography (OCT) images. PATIENTS AND METHODS: This was a proof-of-concept consecutive case series. Patients with an idiopathic full-thickness MH undergoing pars plana vitrectomy surgery with 1 year of follow-up were considered for inclusion. MHs were manually graded by a vitreoretinal surgeon from preoperative OCT images to delineate MH volume. This information was used to train a fully three-dimensional convolutional neural network for automatic segmentation. The main outcome was the correlation of manual MH volume to automated volume segmentation. RESULTS: The correlation between manual and automated MH volume was R2 = 0.94 (n = 24). Automated MH volume demonstrated a higher correlation to change in visual acuity from preoperative to the postoperative 1-year time point compared with the minimum linear diameter (volume: R2 = 0.53; minimum linear diameter: R2 = 0.39). CONCLUSION: MH automated volume segmentation on OCT imaging demonstrated high correlation to manual MH volume measurements. [Ophthalmic Surg Lasers Imaging Retina. 2022;53(4):208-214.].


Asunto(s)
Aprendizaje Profundo , Perforaciones de la Retina , Inteligencia Artificial , Humanos , Perforaciones de la Retina/diagnóstico por imagen , Perforaciones de la Retina/cirugía , Estudios Retrospectivos , Tomografía de Coherencia Óptica/métodos , Vitrectomía/métodos
5.
PLoS One ; 17(2): e0262111, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35157713

RESUMEN

PURPOSE: To evaluate the predictive ability of a deep learning-based algorithm to determine long-term best-corrected distance visual acuity (BCVA) outcomes in neovascular age-related macular degeneration (nARMD) patients using baseline swept-source optical coherence tomography (SS-OCT) and OCT-angiography (OCT-A) data. METHODS: In this phase IV, retrospective, proof of concept, single center study, SS-OCT data from 17 previously treated nARMD eyes was used to assess retinal layer thicknesses, as well as quantify intraretinal fluid (IRF), subretinal fluid (SRF), and serous pigment epithelium detachments (PEDs) using a novel deep learning-based, macular fluid segmentation algorithm. Baseline OCT and OCT-A morphological features and fluid measurements were correlated using the Pearson correlation coefficient (PCC) to changes in BCVA from baseline to week 52. RESULTS: Total retinal fluid (IRF, SRF and PED) volume at baseline had the strongest correlation to improvement in BCVA at month 12 (PCC = 0.652, p = 0.005). Fluid was subsequently sub-categorized into IRF, SRF and PED, with PED volume having the next highest correlation (PCC = 0.648, p = 0.005) to BCVA improvement. Average total retinal thickness in isolation demonstrated poor correlation (PCC = 0.334, p = 0.189). When two features, mean choroidal neovascular membranes (CNVM) size and total fluid volume, were combined and correlated with visual outcomes, the highest correlation increased to PCC = 0.695 (p = 0.002). CONCLUSIONS: In isolation, total fluid volume most closely correlates with change in BCVA values between baseline and week 52. In combination with complimentary information from OCT-A, an improvement in the linear correlation score was observed. Average total retinal thickness provided a lower correlation, and thus provides a lower predictive outcome than alternative metrics assessed. Clinically, a machine-learning approach to analyzing fluid metrics in combination with lesion size may provide an advantage in personalizing therapy and predicting BCVA outcomes at week 52.


Asunto(s)
Aprendizaje Profundo , Líquido Subretiniano/fisiología , Tomografía de Coherencia Óptica , Adulto , Humanos , Inyecciones Intravítreas , Degeneración Macular/diagnóstico , Degeneración Macular/diagnóstico por imagen , Degeneración Macular/tratamiento farmacológico , Prueba de Estudio Conceptual , Receptores de Factores de Crecimiento Endotelial Vascular/uso terapéutico , Proteínas Recombinantes de Fusión/uso terapéutico , Retina/diagnóstico por imagen , Retina/fisiología , Desprendimiento de Retina/patología , Estudios Retrospectivos , Agudeza Visual
6.
Cornea ; 40(5): 635-642, 2021 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-33528225

RESUMEN

PURPOSE: To characterize corneal subbasal nerve plexus features of normal and simian immunodeficiency virus (SIV)-infected macaques by combining in vivo corneal confocal microscopy (IVCM) with automated assessments using deep learning-based methods customized for macaques. METHODS: IVCM images were collected from both male and female age-matched rhesus and pigtailed macaques housed at the Johns Hopkins University breeding colony using the Heidelberg HRTIII with Rostock Corneal Module. We also obtained repeat IVCM images of 12 SIV-infected animals including preinfection and 10-day post-SIV infection time points. All IVCM images were analyzed using a deep convolutional neural network architecture developed specifically for macaque studies. RESULTS: Deep learning-based segmentation of subbasal nerves in IVCM images from macaques demonstrated that corneal nerve fiber length and fractal dimension measurements did not differ between species, but pigtailed macaques had significantly higher baseline corneal nerve fiber tortuosity than rhesus macaques (P = 0.005). Neither sex nor age of macaques was associated with differences in any of the assessed corneal subbasal nerve parameters. In the SIV/macaque model of human immunodeficiency virus, acute SIV infection induced significant decreases in both corneal nerve fiber length and fractal dimension (P = 0.01 and P = 0.008, respectively). CONCLUSIONS: The combination of IVCM and robust objective deep learning analysis is a powerful tool to track sensory nerve damage, enabling early detection of neuropathy. Adapting deep learning analyses to clinical corneal nerve assessments will improve monitoring of small sensory nerve fiber damage in numerous clinical settings including human immunodeficiency virus.


Asunto(s)
Córnea/inervación , Aprendizaje Profundo , Infecciones Virales del Ojo/diagnóstico , Microscopía Confocal , Fibras Nerviosas/patología , Síndrome de Inmunodeficiencia Adquirida del Simio/diagnóstico , Virus de la Inmunodeficiencia de los Simios/patogenicidad , Enfermedades del Nervio Trigémino/diagnóstico , Enfermedad Aguda , Animales , Córnea/diagnóstico por imagen , Modelos Animales de Enfermedad , Infecciones Virales del Ojo/virología , Femenino , Humanos , Macaca mulatta , Macaca nemestrina , Masculino , Persona de Mediana Edad , Fibras Nerviosas/virología , Redes Neurales de la Computación , ARN Viral/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Síndrome de Inmunodeficiencia Adquirida del Simio/virología , Virus de la Inmunodeficiencia de los Simios/genética , Enfermedades del Nervio Trigémino/virología
7.
Transl Vis Sci Technol ; 9(2): 12, 2020 02 18.
Artículo en Inglés | MEDLINE | ID: mdl-32704418

RESUMEN

Purpose: The purpose of this study was to develop a 3D deep learning system from spectral domain optical coherence tomography (SD-OCT) macular cubes to differentiate between referable and nonreferable cases for glaucoma applied to real-world datasets to understand how this would affect the performance. Methods: There were 2805 Cirrus optical coherence tomography (OCT) macula volumes (Macula protocol 512 × 128) of 1095 eyes from 586 patients at a single site that were used to train a fully 3D convolutional neural network (CNN). Referable glaucoma included true glaucoma, pre-perimetric glaucoma, and high-risk suspects, based on qualitative fundus photographs, visual fields, OCT reports, and clinical examinations, including intraocular pressure (IOP) and treatment history as the binary (two class) ground truth. The curated real-world dataset did not include eyes with retinal disease or nonglaucomatous optic neuropathies. The cubes were first homogenized using layer segmentation with the Orion Software (Voxeleron) to achieve standardization. The algorithm was tested on two separate external validation sets from different glaucoma studies, comprised of Cirrus macular cube scans of 505 and 336 eyes, respectively. Results: The area under the receiver operating characteristic (AUROC) curve for the development dataset for distinguishing referable glaucoma was 0.88 for our CNN using homogenization, 0.82 without homogenization, and 0.81 for a CNN architecture from the existing literature. For the external validation datasets, which had different glaucoma definitions, the AUCs were 0.78 and 0.95, respectively. The performance of the model across myopia severity distribution has been assessed in the dataset from the United States and was found to have an AUC of 0.85, 0.92, and 0.95 in the severe, moderate, and mild myopia, respectively. Conclusions: A 3D deep learning algorithm trained on macular OCT volumes without retinal disease to detect referable glaucoma performs better with retinal segmentation preprocessing and performs reasonably well across all levels of myopia. Translational Relevance: Interpretation of OCT macula volumes based on normative data color distributions is highly influenced by population demographics and characteristics, such as refractive error, as well as the size of the normative database. Referable glaucoma, in this study, was chosen to include cases that should be seen by a specialist. This study is unique because it uses multimodal patient data for the glaucoma definition, and includes all severities of myopia as well as validates the algorithm with international data to understand generalizability potential.


Asunto(s)
Aprendizaje Profundo , Glaucoma , Mácula Lútea , Enfermedades del Nervio Óptico , Glaucoma/diagnóstico , Humanos , Mácula Lútea/diagnóstico por imagen , Tomografía de Coherencia Óptica
8.
Eye Vis (Lond) ; 7: 27, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32420401

RESUMEN

BACKGROUND: To develop and validate a deep learning-based approach to the fully-automated analysis of macaque corneal sub-basal nerves using in vivo confocal microscopy (IVCM). METHODS: IVCM was used to collect 108 images from 35 macaques. 58 of the images from 22 macaques were used to evaluate different deep convolutional neural network (CNN) architectures for the automatic analysis of sub-basal nerves relative to manual tracings. The remaining images were used to independently assess correlations and inter-observer performance relative to three readers. RESULTS: Correlation scores using the coefficient of determination between readers and the best CNN averaged 0.80. For inter-observer comparison, inter-correlation coefficients (ICCs) between the three expert readers and the automated approach were 0.75, 0.85 and 0.92. The ICC between all four observers was 0.84, the same as the average between the CNN and individual readers. CONCLUSIONS: Deep learning-based segmentation of sub-basal nerves in IVCM images shows high to very high correlation to manual segmentations in macaque data and is indistinguishable across readers. As quantitative measurements of corneal sub-basal nerves are important biomarkers for disease screening and management, the reported work offers utility to a variety of research and clinical studies using IVCM.

9.
Invest Ophthalmol Vis Sci ; 60(2): 712-722, 2019 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-30786275

RESUMEN

Purpose: To develop and assess a method for predicting the likelihood of converting from early/intermediate to advanced wet age-related macular degeneration (AMD) using optical coherence tomography (OCT) imaging and methods of deep learning. Methods: Seventy-one eyes of 71 patients with confirmed early/intermediate AMD with contralateral wet AMD were imaged with OCT three times over 2 years (baseline, year 1, year 2). These eyes were divided into two groups: eyes that had not converted to wet AMD (n = 40) at year 2 and those that had (n = 31). Two deep convolutional neural networks (CNN) were evaluated using 5-fold cross validation on the OCT data at baseline to attempt to predict which eyes would convert to advanced AMD at year 2: (1) VGG16, a popular CNN for image recognition was fine-tuned, and (2) a novel, simplified CNN architecture was trained from scratch. Preprocessing was added in the form of a segmentation-based normalization to reduce variance in the data and improve performance. Results: Our new architecture, AMDnet, with preprocessing, achieved an area under the receiver operating characteristic (ROC) curve (AUC) of 0.89 at the B-scan level and 0.91 for volumes. Results for VGG16, an established CNN architecture, with preprocessing were 0.82 for B-scans/0.87 for volumes versus 0.66 for B-scans/0.69 for volumes without preprocessing. Conclusions: A CNN with layer segmentation-based preprocessing shows strong predictive power for the progression of early/intermediate AMD to advanced AMD. Use of the preprocessing was shown to improve performance regardless of the network architecture.


Asunto(s)
Aprendizaje Profundo , Diagnóstico por Computador/métodos , Degeneración Macular Húmeda/diagnóstico , Anciano , Anciano de 80 o más Años , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Aprendizaje Automático , Masculino , Persona de Mediana Edad , Redes Neurales de la Computación , Proyectos Piloto , Curva ROC , Tomografía de Coherencia Óptica/métodos
10.
Eye (Lond) ; 33(3): 428-434, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30310161

RESUMEN

PURPOSE: To evaluate longitudinally volume changes in inner and outer retinal layers in early and intermediate age-related macular degeneration (AMD) compared to healthy control eyes using optical coherence tomography (OCT). METHODS: 71 eyes with AMD and 31 control eyes were imaged at two time points: baseline and after 2 years. Automated OCT layer segmentation was performed using OrionTM. This software is able to measure volumes of retinal layers with distinct boundaries including Retinal Nerve Fibre Layer (RNFL), Ganglion Cell-Inner Plexiform Layer (GCIPL), Inner Nuclear Layer (INL), Outer Plexiform Layer (OPL), Outer Nuclear Layer (ONL), Photoreceptors (PR) and Retinal Pigment Epithelium-Bruch's Membrane complex (RPE-BM). The mean retinal layer volumes and volume changes at 2 years were compared between groups. RESULTS: Mean GCIPL and INL volumes were lower, while PR and RPE-BM volumes were higher in AMD eyes than controls at baseline (all P < 0.05) and year 2 (all P < 0.05). In AMD eyes, RNFL and ONL volumes decreased by 0.0232 (P = 0.033) and 0.0851 (P = 0.001), respectively. In contrast, OPL and RPE-BM volumes increased in AMD eyes by 0.0391 (P = 0.000) and 0.0209 (P = 0.000) respectively. Moreover, there were significant differences in longitudinal volume change of OPL (P = 0.02), ONL (P = 0.008) and RPE-BM (P = 0.02) between AMD eyes and controls. CONCLUSIONS: There were abnormal retinal layer volumes and volume changes in eyes with early and intermediate AMD.


Asunto(s)
Lámina Basal de la Coroides/patología , Degeneración Macular/patología , Retina/patología , Células Ganglionares de la Retina/patología , Epitelio Pigmentado de la Retina/patología , Anciano , Lámina Basal de la Coroides/diagnóstico por imagen , Progresión de la Enfermedad , Femenino , Humanos , Degeneración Macular/diagnóstico por imagen , Degeneración Macular/fisiopatología , Masculino , Persona de Mediana Edad , Retina/diagnóstico por imagen , Estudios Retrospectivos , Tomografía de Coherencia Óptica , Agudeza Visual
11.
Graefes Arch Clin Exp Ophthalmol ; 254(3): 561-7, 2016 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-26016810

RESUMEN

PURPOSE: To characterise the changes of the retinal layers in patients with acute anterior ischaemic optic neuropathy (AION), aiming to identify imaging markers for predicting the residual visual function. METHODS: This was a retrospective review of consecutive patients with unilateral AION from January 2010 to December 2013. We analysed affected eyes at baseline and 1 month later, compared to fellow healthy eyes. Utilising novel image analysis software, we conducted algorithmic segmentation in layers and division in early treatment of diabetic retinopathy study (ETDRS) quadrants of optical coherence tomography images of the macula. Pearson product moment regression analysis of retinal layer thickness and best corrected visual acuity (BCVA) in logMAR units and mean deviation of the SITA 24-2 visual field (VF) were carried out at the 1-month time point. RESULTS: Twenty eyes from 20 patients were included and compared to 20 healthy fellow eyes. At baseline, we found a significantly increased mean thickness of the retinal nerve fibre layer (RNFL) of 42.2 µm (±6.7SD) in AION eyes compared to 37.9 µm (±4.2 SD) in healthy eyes (p = 0.002). The outer nuclear layer (ONL) was also significantly thickened at 96.6 µm (±7.2 SD) compared to 90.8 µm (±5.7 SD) in the fellow eye (p < 0.001). After 1 month, the RNFL and the ganglion cell layer (GCL) were thinned 17.7 % [to 31.2 µm (±6.4 SD), p < 0.001] and 19.3 % [to 66.5 µm (±7.0 SD), p < 0.001] compared to the contralateral eye. Additionally, the ONL remained thickened at 96.7 µm (±7.0 SD, p < 0.001). At baseline, we found a significant correlation between the ONL thickness and the VF (r = -0.482, p = 0.005) and the BCVA at discharge (r = 0.552, p < 0.001), indicating that a thicker ONL correlates with poorer visual function. The GCL thickness also correlates with the BCVA at discharge (r = 0.411, p = 0.02), where a thinner GCL predicts worse BCVA. At the 1-month time point, the GCL thinning was correlated with both the VF (r = 0.471, p = 0.005) and the BCVA (r = -0.456, p = 0.007), indicating worse visual function. CONCLUSIONS: Changes in the thickness of different layers of the retina occur early in the course of AION and evolve over time, resulting in the atrophy of the GCL and RNFL. ONL thickening at baseline is associated with visual dysfunction. Thinning of the GCL after 1 month correlates with poorer VF and BCVA at 1 month after acute AION.


Asunto(s)
Fibras Nerviosas/patología , Neuropatía Óptica Isquémica/fisiopatología , Células Ganglionares de la Retina/patología , Agudeza Visual/fisiología , Campos Visuales/fisiología , Enfermedad Aguda , Anciano , Arteritis/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos , Tomografía de Coherencia Óptica
12.
Am J Pathol ; 184(6): 1652-9, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24828391

RESUMEN

Peripheral neuropathy is the most frequent neurological complication of HIV infection, affecting more than one-third of infected patients, including patients treated with antiretroviral therapy. Although emerging noninvasive techniques for corneal nerve assessments are increasingly being used to diagnose and monitor peripheral neuropathies, corneal nerve alterations have not been characterized in HIV. Here, to determine whether SIV infection leads to corneal nerve fiber loss, we immunostained corneas for the nerve fiber marker ßIII tubulin. We developed and applied both manual and automated methods to measure nerves in the corneal subbasal plexus. These counting methods independently indicated significantly lower subbasal corneal nerve fiber density among SIV-infected animals that rapidly progressed to AIDS compared with slow progressors. Concomitant with decreased corneal nerve fiber density, rapid progressors had increased levels of SIV RNA and CD68-positive macrophages and expression of glial fibrillary acidic protein by glial satellite cells in the trigeminal ganglia, the location of the neuronal cell bodies of corneal sensory nerve fibers. In addition, corneal nerve fiber density was directly correlated with epidermal nerve fiber length. These findings indicate that corneal nerve assessment has great potential to diagnose and monitor HIV-induced peripheral neuropathy and to set the stage for introducing noninvasive techniques to measure corneal nerve fiber density in HIV clinical settings.


Asunto(s)
Infecciones por VIH , VIH-1 , Enfermedades del Sistema Nervioso Periférico , Síndrome de Inmunodeficiencia Adquirida del Simio , Virus de la Inmunodeficiencia de los Simios , Animales , Córnea/inervación , Córnea/metabolismo , Córnea/patología , Epidermis/inervación , Epidermis/metabolismo , Epidermis/patología , Proteína Ácida Fibrilar de la Glía/metabolismo , Infecciones por VIH/metabolismo , Infecciones por VIH/prevención & control , Macaca nemestrina , Fibras Nerviosas/metabolismo , Fibras Nerviosas/patología , Enfermedades del Sistema Nervioso Periférico/metabolismo , Enfermedades del Sistema Nervioso Periférico/patología , Síndrome de Inmunodeficiencia Adquirida del Simio/metabolismo , Síndrome de Inmunodeficiencia Adquirida del Simio/patología
13.
JAMA Neurol ; 70(1): 34-43, 2013 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-23318513

RESUMEN

OBJECTIVE: To determine the relationships between conventional and segmentation-derived optical coherence tomography (OCT) retinal layer thickness measures with intracranial volume (a surrogate of head size) and brain substructure volumes in multiple sclerosis (MS). DESIGN: Cross-sectional study. SETTING: Johns Hopkins University, Baltimore, Maryland. PARTICIPANTS: A total of 84 patients with MS and 24 healthy control subjects. MAIN OUTCOME MEASURES: High-definition spectral-domain OCT conventional and automated segmentation-derived discrete retinal layer thicknesses and 3-T magnetic resonance imaging brain substructure volumes. RESULTS: Peripapillary retinal nerve fiber layer as well as composite ganglion cell layer+inner plexiform layer thicknesses in the eyes of patients with MS without a history of optic neuritis were associated with cortical gray matter (P=.01 and P=.04, respectively) and caudate (P=.04 and P=.03, respectively) volumes. Inner nuclear layer thickness, also in eyes without a history of optic neuritis, was associated with fluid-attenuated inversion recovery lesion volume (P=.007) and inversely associated with normal-appearing white matter volume (P=.005) in relapsing-remitting MS. As intracranial volume was found to be related with several of the OCT measures in patients with MS and healthy control subjects and is already known to be associated with brain substructure volumes, all OCT-brain substructure relationships were adjusted for intracranial volume. CONCLUSIONS Retinal measures reflect global central nervous system pathology in multiple sclerosis, with thicknesses of discrete retinal layers each appearing to be associated with distinct central nervous system processes. Moreover, OCT measures appear to correlate with intracranial volume in patients with MS and healthy control subjects, an important unexpected factor unaccounted for in prior studies examining the relationships between peripapillary retinal nerve fiber layer thickness and brain substructure volumes.


Asunto(s)
Axones/patología , Sistema Nervioso Central/patología , Esclerosis Múltiple/patología , Retina , Neuronas Retinianas/patología , Adulto , Núcleo Caudado/patología , Corteza Cerebral/patología , Estudios Transversales , Femenino , Humanos , Imagen por Resonancia Magnética/instrumentación , Imagen por Resonancia Magnética/métodos , Masculino , Persona de Mediana Edad , Retina/patología , Tomografía de Coherencia Óptica/instrumentación , Tomografía de Coherencia Óptica/métodos
14.
Neurology ; 80(1): 47-54, 2013 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-23267030

RESUMEN

OBJECTIVE: To determine the effect of clinical and radiologic disease activity on the rate of thinning of the ganglion cell/inner plexiform (GCIP) layer and the retinal nerve fiber layer in patients with multiple sclerosis (MS) using optical coherence tomography (OCT). METHODS: One hundred sixty-four patients with MS and 59 healthy controls underwent spectral-domain OCT scans every 6 months for a mean follow-up period of 21.1 months. Baseline and annual contrast-enhanced brain MRIs were performed. Patients who developed optic neuritis during follow-up were excluded from analysis. RESULTS: Patients with the following features of disease activity during follow-up had faster rates of annualized GCIP thinning: relapses (42% faster, p = 0.007), new gadolinium-enhancing lesions (54% faster, p < 0.001), and new T2 lesions (36% faster, p = 0.02). Annual GCIP thinning was 37% faster in those with disability progression during follow-up, and 43% faster in those with disease duration <5 years vs >5 years (p = 0.003). Annual rates of GCIP thinning were highest in patients exhibiting combinations of new gadolinium-enhancing lesions, new T2 lesions, and disease duration <5 years (70% faster in patients with vs without all 3 characteristics, p < 0.001). CONCLUSIONS: MS patients with clinical and/or radiologic nonocular disease activity, particularly early in the disease course, exhibit accelerated GCIP thinning. Our findings suggest that retinal changes in MS reflect global CNS processes, and that OCT-derived GCIP thickness measures may have utility as an outcome measure for assessing neuroprotective agents, particularly in early, active MS.


Asunto(s)
Esclerosis Múltiple/patología , Degeneración Nerviosa/patología , Células Ganglionares de la Retina/patología , Neuronas Retinianas/patología , Tomografía de Coherencia Óptica/métodos , Adulto , Estudios de Casos y Controles , Progresión de la Enfermedad , Femenino , Estudios de Seguimiento , Humanos , Masculino , Persona de Mediana Edad , Fibras Nerviosas/patología , Neuroimagen/métodos , Neuroimagen/estadística & datos numéricos , Tomografía de Coherencia Óptica/estadística & datos numéricos
15.
J Neurol ; 259(10): 2119-30, 2012 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-22418995

RESUMEN

Macular optical coherence tomography (OCT) segmentation, enabling quantification of retinal axonal and neuronal subpopulations, may help elucidate the neuroretinal pathobiology of multiple sclerosis (MS). This study aimed to determine the agreement, reproducibility, and visual correlations of retinal layer thicknesses measured by different OCT segmentation techniques, on two spectral-domain OCT devices. Macular scans of 52 MS patients and 30 healthy controls from Spectralis OCT and Cirrus HD-OCT were segmented using fully manual (Spectralis), computer-aided manual (Spectralis and Cirrus), and fully automated (Cirrus) segmentation techniques. Letter acuity was recorded. Bland-Altman analyses revealed low mean differences across OCT segmentation techniques on both devices for ganglion cell + inner plexiform layers (GCIP; 0.76-2.43 µm), inner nuclear + outer plexiform layers (INL + OPL; 0.36-1.04 µm), and outer nuclear layers including photoreceptor segment (ONL + PR; 1.29-3.52 µm) thicknesses. Limits of agreement for GCIP and ONL + PR thicknesses were narrow. Results of fully manual and computer-aided manual segmentation were comparable to those of fully automated segmentation. MS patients demonstrated macular RNFL, GCIP, and ONL + PR thinning compared to healthy controls across OCT segmentation techniques, irrespective of device (p < 0.03 for all). Low-contrast letter acuity in MS correlated significantly and more strongly with GCIP than peripapillary RNFL thicknesses, regardless of the segmentation method or device. GCIP and ONL + PR thicknesses, measured by different OCT devices and segmentation techniques, are reproducible and agree at the individual and cohort levels. GCIP thinning in MS correlates with visual dysfunction. Significant ONL + PR thinning, detectable across OCT segmentation techniques and devices, strongly supports ONL pathology in MS. Fully automated, fully manual and computer-assisted manual OCT segmentation techniques compare closely, highlighting the utility of accurate and time-efficient automated segmentation outcomes in MS clinical trials.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Esclerosis Múltiple/patología , Neuronas Retinianas/patología , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven
16.
Brain ; 135(Pt 2): 521-33, 2012 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-22006982

RESUMEN

Post-mortem ganglion cell dropout has been observed in multiple sclerosis; however, longitudinal in vivo assessment of retinal neuronal layers following acute optic neuritis remains largely unexplored. Peripapillary retinal nerve fibre layer thickness, measured by optical coherence tomography, has been proposed as an outcome measure in studies of neuroprotective agents in multiple sclerosis, yet potential swelling during the acute stages of optic neuritis may confound baseline measurements. The objective of this study was to ascertain whether patients with multiple sclerosis or neuromyelitis optica develop retinal neuronal layer pathology following acute optic neuritis, and to systematically characterize such changes in vivo over time. Spectral domain optical coherence tomography imaging, including automated retinal layer segmentation, was performed serially in 20 participants during the acute phase of optic neuritis, and again 3 and 6 months later. Imaging was performed cross-sectionally in 98 multiple sclerosis participants, 22 neuromyelitis optica participants and 72 healthy controls. Neuronal thinning was observed in the ganglion cell layer of eyes affected by acute optic neuritis 3 and 6 months after onset (P < 0.001). Baseline ganglion cell layer thicknesses did not demonstrate swelling when compared with contralateral unaffected eyes, whereas peripapillary retinal nerve fibre layer oedema was observed in affected eyes (P = 0.008) and subsequently thinned over the course of this study. Ganglion cell layer thickness was lower in both participants with multiple sclerosis and participants with neuromyelitis optica, with and without a history of optic neuritis, when compared with healthy controls (P < 0.001) and correlated with visual function. Of all patient groups investigated, those with neuromyelitis optica and a history of optic neuritis exhibited the greatest reduction in ganglion cell layer thickness. Results from our in vivo longitudinal study demonstrate retinal neuronal layer thinning following acute optic neuritis, corroborating the hypothesis that axonal injury may cause neuronal pathology in multiple sclerosis. Further, these data provide evidence of subclinical disease activity, in both participants with multiple sclerosis and with neuromyelitis optica without a history of optic neuritis, a disease in which subclinical disease activity has not been widely appreciated. No pathology was seen in the inner or outer nuclear layers of eyes with optic neuritis, suggesting that retrograde degeneration after optic neuritis may not extend into the deeper retinal layers. The subsequent thinning of the ganglion cell layer following acute optic neuritis, in the absence of evidence of baseline swelling, suggests the potential utility of quantitative optical coherence tomography retinal layer segmentation to monitor neuroprotective effects of novel agents in therapeutic trials.


Asunto(s)
Esclerosis Múltiple/patología , Nervio Óptico/patología , Neuritis Óptica/patología , Células Ganglionares de la Retina/patología , Adulto , Axones/patología , Estudios Transversales , Femenino , Humanos , Masculino , Persona de Mediana Edad , Retina/patología , Tomografía de Coherencia Óptica
17.
Invest Ophthalmol Vis Sci ; 52(11): 8323-9, 2011 Oct 21.
Artículo en Inglés | MEDLINE | ID: mdl-21917932

RESUMEN

PURPOSE: To demonstrate the capability of SD-OCT to measure macular retinal ganglion cell-inner plexiform layer (GCIPL) thickness and to assess its reproducibility in glaucomatous eyes. METHODS: Fifty-one glaucomatous eyes (26 mild, 11 moderate, 14 severe) of 51 patients underwent macular scanning using the Cirrus HD-OCT (Carl Zeiss Meditec, Dublin, CA) macula 200×200 acquisition protocol. Five scans were obtained on 5 days within 2 months. The ganglion cell analysis (GCA) algorithm was used to detect the macular GCIPL and to measure the thickness of the overall average, minimum, superotemporal, superior, superonasal, inferonasal, inferior, and inferotemporal GCIPL. The reproducibility of the measurements was evaluated with intraclass correlation coefficients (ICCs), coefficients of variation (COVs), and test-retest standard deviations (TRTSDs). RESULTS: Segmentation and measurement of GCIPL thickness were successful in 50 of 51 subjects. All ICCs ranged between 0.94 and 0.98, but ICCs for average and superior GCIPL parameters (0.97-0.98) were slightly higher than for inferior GCIPL parameters (0.94-0.97). All COVs were <5%, with 1.8% for average GCIPL and COVs for superior GCIPL parameters (2.2%-3.0%) slightly lower than those for inferior GCIPL parameters (2.5%-3.6%). The TRTSD was lowest for average GCIPL (1.16 µm) and varied from 1.43 to 2.15 µm for sectoral GCIPL CONCLUSIONS: The Cirrus HD-OCT GCA algorithm can successfully segment macular GCIPL and measure GCIPL thickness with excellent intervisit reproducibility. Longitudinal monitoring of GCIPL thickness may be possible with Cirrus HD-OCT for assessing glaucoma progression.


Asunto(s)
Glaucoma/patología , Mácula Lútea/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Tomografía de Coherencia Óptica/normas , Anciano , Anciano de 80 o más Años , Algoritmos , Progresión de la Enfermedad , Humanos , Modelos Lineales , Persona de Mediana Edad , Reproducibilidad de los Resultados , Índice de Severidad de la Enfermedad , Programas Informáticos
18.
Mult Scler ; 17(12): 1449-63, 2011 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-21865411

RESUMEN

BACKGROUND: Post-mortem analyses of multiple sclerosis (MS) eyes demonstrate prominent retinal neuronal ganglion cell layer (GCL) loss, in addition to related axonal retinal nerve fiber layer (RNFL) loss. Despite this, clinical correlations of retinal neuronal layers remain largely unexplored in MS. OBJECTIVES: To determine if MS patients exhibit in vivo retinal neuronal GCL loss, deeper retinal neuronal loss, and investigate correlations between retinal layer thicknesses, MS clinical subtype and validated clinical measures. METHODS: Cirrus HD-optical coherence tomography (OCT), utilizing automated intra-retinal layer segmentation, was performed in 132 MS patients and 78 healthy controls. MS classification, Expanded Disability Status Scale (EDSS) and visual function were recorded in study subjects. RESULTS: GCL+inner plexiform layer (GCIP) was thinner in relapsing-remitting MS (RRMS; n = 96, 71.6 µm), secondary progressive MS (SPMS; n = 20, 66.4 µm) and primary progressive MS (PPMS; n = 16, 74.1 µm) than in healthy controls (81.8 µm; p < 0.001 for all). GCIP thickness was most decreased in SPMS, and although GCIP thickness correlated significantly with disease duration, after adjusting for this, GCIP thickness remained significantly lower in SPMS than RRMS. GCIP thickness correlated significantly, and better than RNFL thickness, with EDSS, high-contrast, 2.5% low-contrast and 1.25% low-contrast letter acuity in MS. 13.6% of patients also demonstrated inner or outer nuclear layer thinning. CONCLUSIONS: OCT segmentation demonstrates in vivo GCIP thinning in all MS subtypes. GCIP thickness demonstrates better structure-function correlations (with vision and disability) in MS than RNFL thickness. In addition to commonly observed RNFL/GCIP thinning, retinal inner and outer nuclear layer thinning occur in MS.


Asunto(s)
Esclerosis Múltiple/patología , Retina/patología , Células Ganglionares de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Adulto , Femenino , Humanos , Masculino , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple Crónica Progresiva/patología , Esclerosis Múltiple Recurrente-Remitente/patología , Fibras Nerviosas/patología , Pruebas de Visión
19.
Ophthalmology ; 118(7): 1348-57, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21397334

RESUMEN

OBJECTIVE: To evaluate a new automated analysis of optic disc images obtained by spectral-domain optical coherence tomography (SD OCT). Areas of the optic disc, cup, and neural rim in SD OCT images were compared with these areas from stereoscopic photographs to represent the current traditional optic nerve evaluation. The repeatability of measurements by each method was determined and compared. DESIGN: Evaluation of diagnostic technology. PARTICIPANTS: One hundred nineteen healthy eyes, 23 eyes with glaucoma, and 7 glaucoma suspect eyes. METHODS: Optic disc and cup margins were traced from stereoscopic photographs by 3 individuals independently. Optic disc margins and rim widths were determined automatically in SD OCT. A subset of photographs was examined and traced a second time, and duplicate SD OCT images also were analyzed. MAIN OUTCOME MEASURES: Agreement among photograph readers, between duplicate readings, and between SD OCT and photographs were quantified by the intraclass correlation coefficient (ICC), by the root mean square, and by the standard deviation of the differences. RESULTS: Optic disc areas tended to be slightly larger when judged in photographs than by SD OCT, whereas cup areas were similar. Cup and optic disc areas showed good correlation (0.8) between the average photographic reading and SD OCT, but only fair correlation of rim areas (0.4). The SD OCT was highly reproducible (ICC, 0.96-0.99). Each reader also was consistent with himself on duplicate readings of 21 photographs (ICC, 0.80-0.88 for rim area and 0.95-0.98 for all other measurements), but reproducibility was not as good as SD OCT. Measurements derived from SD OCT did not differ from photographic readings more than the readings of photographs by different readers differed from each other. CONCLUSIONS: Designation of the cup and optic disc boundaries by an automated analysis of SD OCT was within the range of variable designations by different readers from color stereoscopic photographs, but use of different landmarks typically made the designation of the optic disc size somewhat smaller in the automated analysis. There was better repeatability among measurements from SD OCT than from among readers of photographs. The repeatability of automated measurement of SD OCT images is promising for use both in diagnosis and in monitoring of progression.


Asunto(s)
Glaucoma/diagnóstico , Disco Óptico/patología , Fotograbar/métodos , Tomografía de Coherencia Óptica/métodos , Automatización , Estudios de Cohortes , Humanos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Programas Informáticos
20.
Brain ; 134(Pt 2): 518-33, 2011 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-21252110

RESUMEN

Optical coherence tomography studies in multiple sclerosis have primarily focused on evaluation of the retinal nerve fibre layer. The aetiology of retinal changes in multiple sclerosis is thought to be secondary to optic nerve demyelination. The objective of this study was to use optical coherence tomography to determine if a subset of patients with multiple sclerosis exhibit primary retinal neuronopathy, in the absence of retrograde degeneration of the retinal nerve fibre layer and to ascertain if such patients may have any distinguishing clinical characteristics. We identified 50 patients with multiple sclerosis with predominantly macular thinning (normal retinal nerve fibre-layer thickness with average macular thickness < 5th percentile), a previously undescribed optical coherence tomography defined phenotype in multiple sclerosis, and compared them with 48 patients with multiple sclerosis with normal optical coherence tomography findings, 48 patients with multiple sclerosis with abnormal optical coherence tomography findings (typical for multiple sclerosis) and 86 healthy controls. Utilizing a novel retinal segmentation protocol, we found that those with predominant macular thinning had significant thinning of both the inner and outer nuclear layers, when compared with other patients with multiple sclerosis (P < 0.001 for both), with relative sparing of the ganglion cell layer. Inner and outer nuclear layer thicknesses in patients with non-macular thinning predominant multiple sclerosis were not different from healthy controls. Segmentation analyses thereby demonstrated extensive deeper disruption of retinal architecture in this subtype than may be expected due to retrograde degeneration from either typical clinical or sub-clinical optic neuropathy. Functional corroboration of retinal dysfunction was provided through multi-focal electroretinography in a subset of such patients. These findings support the possibility of primary retinal pathology in a subset of patients with multiple sclerosis. Multiple sclerosis-severity scores were also significantly increased in patients with the macular thinning predominant phenotype, compared with those without this phenotype (n = 96, P=0.006). We have identified a unique subset of patients with multiple sclerosis in whom there appears to be disproportionate thinning of the inner and outer nuclear layers, which may be occurring as a primary process independent of optic nerve pathology. In vivo analyses of retinal layers in multiple sclerosis have not been previously performed, and structural demonstration of pathology in the deeper retinal layers, such as the outer nuclear layer, has not been previously described in multiple sclerosis. Patients with inner and outer nuclear layer pathology have more rapid disability progression and thus retinal neuronal pathology may be a harbinger of a more aggressive form of multiple sclerosis.


Asunto(s)
Esclerosis Múltiple/patología , Retina/patología , Enfermedades de la Retina/patología , Tomografía de Coherencia Óptica/métodos , Adulto , Anciano , Electrorretinografía/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Biológicos , Esclerosis Múltiple/complicaciones , Esclerosis Múltiple/diagnóstico , Esclerosis Múltiple/fisiopatología , Nervio Óptico/patología , Nervio Óptico/fisiopatología , Retina/fisiopatología , Enfermedades de la Retina/complicaciones , Degeneración Retrógrada/patología , Degeneración Retrógrada/fisiopatología , Índice de Severidad de la Enfermedad , Visión Ocular/fisiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...